MECHANICAL RUN TEST REPORT

TAG NUMBER 100PM-002A DESCRIPTION DESALTER WATER CIRCULATION PUMPS


LOCATION EPC-1 DATE & TIME 07-02-2023 08:30 HRS
AREA 100 ITW NO
UNIT NAME CDU EPC 1
Technical Data
SPEED* RPM 2969 RATED POWER KW 110 SHAFT HEIGHT 315
ROTATION* (Direction) CW SUCTION PRESSURE 0.8 SUCTION TEMP. 26
STARTING CURRENT 938 DISCHARGE PRESSURE 17 DISCHARGE TEMP. 27
RATED CURRENT* 179 DISCHARGE FLOW RATE 151 NPSH AVAILABLE 132.57
POWER CONSUMED 152.4 MINIMUM FLOW (data sheet) 56 DESIGN FLOW 124
Test Liquid/gas – HC or Water or Air WATER Design suction pressure 16.2 Design discharge Pre 30.9
MEASUREMENTS SUMMARY
Vibration amplitudes measured on the equipment during Mechanical run test are as under Location
DIRECTION & AMPLITUDE mm/sec rms MEASUREMENT TIME
DRIVER MOTOR 0 60 120 180 240
NDE-H 0.33 0.34
NDE-V 0.33 0.33
NDE-A 0.23 0.34
DE-H 0.41 0.48
DE-V 0.22 0.21
DE-A 0.21 0.19
NDE (TEMP.̊C) 27 C 28 C
DE (TEMP ̊C) 29 C 30 C
DRIVEN PUMP MEASUREMENT TIME
0 60 120 180 240

DE-H 0.81 0.87


DE-V 0.71 0.68
DE-A 0.57 0.58
NDE-H 0.71 0.67
NDE-V 0.57 0.56
NDE-A 0.52 0.51
DE (TEMP.̊C) 31 C 34 C
NDE (TEMP.̊C) 32 C 36 C
Observations: REJECTED DUE TO SEAL LEAK,

RECOMMENDATIONS:

TEST RESULT Not Acceptable

Report Prepared by HAFIZ FARHAN/ Ahmed

For OQ8 Maintenance Team