120ae-001-K2c (MRT) (Rejected)
120ae-001-K2c (MRT) (Rejected)
TAG NUMBER 120AE-001-K2C DESCRIPTION 2ND STAGE HHPS VAPOR AIR COOLER FAN
LOCATION EPC-1 DATE & TIME 22-02-2022 08:30 HRS
AREA 120 ITW NO
UNIT NAME HCU EPC 1
Technical Data
SPEED* RPM 1477 RATED POWER KW 45 SHAFT HEIGHT 250
ROTATION* (Direction) CCW SUCTION PRESSURE NA SUCTION TEMP. NA
STARTING CURRENT NA DISCHARGE PRESSURE NA DISCHARGE TEMP. NA
RATED CURRENT* 77.3 DISCHARGE FLOW RATE NA NPSH AVAILABLE NA
POWER CONSUMED 47.1 MINIMUM FLOW (data sheet) NA DESIGN FLOW NA
Test Liquid/gas – HC or Water or Air AIR Design suction pressure NA Design discharge Pre NA
MEASUREMENTS SUMMARY
Vibration amplitudes measured on the equipment during Mechanical run test are as under Location
DIRECTION & AMPLITUDE mm/sec rms MEASUREMENT TIME
DRIVER MOTOR 0 60 120 180 240
NDE-H 0.66 0.85
NDE-V 1.63 1.96
NDE-A 2.91 2.82
DE-H 1.53 1.62
DE-V 3.11 2.89
DE-A 1.79 2.26
NDE (TEMP.̊C) 26 C 30 C
DE (TEMP ̊C) 26 C 36 C
DRIVEN FAN MEASUREMENT TIME
0 60 120 180 240
DE-A
NDE-H
NDE-V
NDE-A
DE (TEMP.̊C) 25 C 29 C
NDE (TEMP.̊C)
Observations: High vibration 7.1 mm/sec observed on Fan bearing data collected from DCS. The fan vibration has been
fluctuated from 5.4 to 7.1 mm/sec and the fan was tripped due to high vibration. we observed there is slightly high vibration
from motor side . Bump test has been done and recorded natural frequency and excited with the 1x peak which is indicate the
pure resonance problem
RECOMMENDATIONS: . Recommended to be Check for any looseness in the system and tighten if any , Check the
healthiness of the fan vibration probes and Check the balancing condition of the fans.