SHEAR TEST DATA FOR SIKASIL® SG-500 CN Zürich, February 10,


2021

Dear Mr. Chung,

below you can find the shear test results obtained on Sikasil® SG-500 CN joints 12 mm x 12 mm x 50 mm
(width x thickness x length) tested at the speed of 5 mm/min according to Sika CQP 555-1.

The data below show that a safety factor >> 6 is ensured, when a design shear strength of 0.105 MPa is
used.

IMPORTANT NOTE:
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein. In case of changes in the parameters
of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein is only
provided with the purpose of providing the user with additional information as to Sika's products. It does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users should always refer to the most recent issue of the local Product Data Sheet for the product concerned,
copies of which will be supplied on request.

SIKA SERVICES AG
Tueffenwies 16, P.O.Box ∙ 8048 Zurich ∙ Switzerland
Phone: +41 58 436 58 01 · Fax: +41 58 436 54 07 · www.sika.com
PAGES 2/4
DATE February 9, 202121

Shear Adhesion Test using H-Specimens CQP 555-1

Aluminum / Aluminum Max. Force Shear strength Elongation at


Failure
Sikasil® SG-500 CN [MPa] [MPa] break [%]

Specimen 1 510.36 0.85 - 100% Cohesive


Specimen 2 697.70 1.16 210.32 100% Cohesive
Specimen 3 593.82 0.99 194.76 100% Cohesive
Specimen 4 620.79 1.03 190.48 100% Cohesive
Specimen 5 630.01 1.05 176.44 100% Cohesive
Specimen 6 405.36 0.68 156.66 100% Cohesive
Specimen 7 847.17 1.41 244.49 100% Cohesive
Specimen 8 643.21 1.07 193.19 100% Cohesive
Specimen 9 680.65 1.13 198.65 100% Cohesive
Specimen 10 458.22 0.76 151.10 100% Cohesive
Average 608.73 1.01 190.68 100% Cohesive
Standard deviation 127.21 0.21 28.05

IMPORTANT NOTE:
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein. In case of changes in the parameters
of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein is only
provided with the purpose of providing the user with additional information as to Sika's products. It does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users should always refer to the most recent issue of the local Product Data Sheet for the product concerned,
copies of which will be supplied on request.

SIKA SERVICES AG
Tueffenwies 16, P.O.Box ∙ 8048 Zurich ∙ Switzerland
Phone: +41 58 436 58 01 · Fax: +41 58 436 54 07 · www.sika.com
PAGES 3/4
DATE February 9, 202121

Shear Adhesion Test using H-Specimens


Probe 1 Probe 2 Probe 3 Probe 4 Probe 5
Probe 6 Probe 7 Probe 8 Probe 9 Probe 10
1.6

1.4
Shear strength [MPa]

1.2

0.8

0.6

0.4

0.2

0
0 50 100 150 200 250
Elongation at break [%]

Data and diagrams shown in this document are indicative only and based on one single empirical
measurement on small scale laboratory samples. The values are approximated and subjected to
experimental variation. For specific advice, consult the Technical Department of Sika Industry.

IMPORTANT NOTE:
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein. In case of changes in the parameters
of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein is only
provided with the purpose of providing the user with additional information as to Sika's products. It does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users should always refer to the most recent issue of the local Product Data Sheet for the product concerned,
copies of which will be supplied on request.

SIKA SERVICES AG
Tueffenwies 16, P.O.Box ∙ 8048 Zurich ∙ Switzerland
Phone: +41 58 436 58 01 · Fax: +41 58 436 54 07 · www.sika.com
PAGES 4/4
DATE February 9, 202121

Please do not hesitate to contact us should you require any further assistance regarding this matter.

Best Regards
Sika Services AG
Corporate Technical Service

Pedro Galvez Viviana Nardini


Corporate Marketfield Engineer Marketfield Engineer Façade / Insulating Glass
Sika Services AG Sika Services AG

IMPORTANT NOTE:
The information contained herein and any other advice are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under
normal conditions in accordance with Sika's recommendations. The information only applies to the application(s) and product(s) expressly referred to herein. In case of changes in the parameters
of the application, such as changes in substrates etc., or in case of a different application, consult Sika's Technical Service prior to using Sika products. The information contained herein is only
provided with the purpose of providing the user with additional information as to Sika's products. It does not relieve the user of the products from testing them for the intended application and
purpose. All orders are accepted subject to our current terms of sale and delivery. Users should always refer to the most recent issue of the local Product Data Sheet for the product concerned,
copies of which will be supplied on request.

SIKA SERVICES AG
Tueffenwies 16, P.O.Box ∙ 8048 Zurich ∙ Switzerland
Phone: +41 58 436 58 01 · Fax: +41 58 436 54 07 · www.sika.com

You might also like