You are on page 1of 3

14 March 2022

Document ID: 599209


Customer - BM WINDOWS
Address: 60 Nguyen Dinh Chieu Street, Dakao Ward, District 1 Ho Chi Minh Viet Nam
THUAN THANH GLASS CORPORATION
18 - 20 LE QUY DON St., 6 WARD, 3 Dist., HO CHI MINH City
HOCHIMINH City,
Viet Nam
Ho Chi Minh
70000

Project Name: 21-009832 - TIEN GIANG GENERAL HOSPITAL


Project Address:Phuoc Thanh Commune – My Tho City – Tien Giang Province Tien Giang Viet Nam
Sample Test Name: Sample test request

Ref.: COMPATIBILITY Test Report for TIEN GIANG GENERAL HOSPITAL - Sample test request

Dear NGUYEN Hong Thai,

The DOW construction laboratory has completed the compatibility testing in support of your above referenced
project.
The compatibility tests are performed in accordance to the adapted ASTM C1087. A summary of this laboratory
testing / evaluation and application recommendations is given below.

1. Sample Nr 234870 Substrate Details


Substrate Type Membrane - Flashing or Roofing
Substrate Description 0.38mm clear PVB film layer - 250x250mm
Surface to test Uniform Surface
Sealant Application Recommendation
DOWSILᵀᴹ 688 Glazing & Cladding Silicone Sealant Approved for Contact in Weatherseal Applications
DOWSILᵀᴹ 791 Silicone Weatherproofing Sealant Approved for Contact in Weatherseal Applications
DOWSILᵀᴹ 795 Structural Glazing Sealant Approved for Contact in Structural Applications
DOWSILᵀᴹ 983 Structural Glazing Sealant Approved for Contact in Structural Applications

2. Sample Nr 234871 Substrate Details


Substrate Type Membrane - Flashing or Roofing

Page 1 of 3

DOW HIGH PERFORMANCE BUILDING AMERICAS ASIA EMEAI


Imagine the Possibilities Sealant Test Lab, DC-4, Lab 3A4 Shanghai Dow Center Parc Industriel – Zone C
consumer.dow.com/Construction 2200 W.Salzburg Road 936 Zhangheng Road B-7180 Seneffe
Auburn, MI 48611 Pudong District, Shanghai Belgium
USA 201203 P. R. China Phone: + 32 (0) 64 511 156
Phone : + 1-800-346-9882 Phone: +86 21 38511100 Fax: +32 (0) 270 62 319
americas.cool@dow.com asia.cool@dow.com emeai.cool@dow.com

General Business
14 March 2022
Document ID: 599209
Substrate Description 0.38mm B104 Grey PVB film layer - 250x250mm
Surface to test Uniform Surface
Sealant Application Recommendation
DOWSILᵀᴹ 688 Glazing & Cladding Silicone Sealant Approved for Contact in Weatherseal Applications
DOWSILᵀᴹ 791 Silicone Weatherproofing Sealant Approved for Contact in Weatherseal Applications
DOWSILᵀᴹ 795 Structural Glazing Sealant Approved for Contact in Structural Applications
DOWSILᵀᴹ 983 Structural Glazing Sealant Approved for Contact in Structural Applications

Based on the ASTM C-1087 test method, compatible or approved results indicate that the Dow silicone sealants
tested adhered to the test material. ASTM C-1087 is a qualitative adhesion test but a good indication for non-
moving applications. Compatible or approved results from the above test indicate that Dow sealant tested is not
adversely affected by contact with the test material sampled. Dow will not comment on whether the Dow sealant
will affect the test material sampled. You must consult with the supplier of the test material sampled to receive
their statement on compatibility.

Based on the results of the above test, we have determined that the Dow sealant tested is not adversely affected
by contact with the cured sealant product tested. Dow will not comment on whether the Dow sealant will affect the
sealant product tested. You must consult with the supplier of the sealant product for their statement on
compatibility. Dow cannot control any formulation changes by the sealant manufacturer which may affect
compatibility. To ensure full compatibility between sealants, we recommend that you consider the use of an
equivalent Dow product for this application.

For structural glazing application, the results of the compatibility testing are only valid when Dow has approved
glazing details, and has tested and approved all substrates and accessory materials that contact the structural
silicone sealant.

The results of the compatibility testing are only valid as long as the supplier certifies that neither the formulation
nor manufacturing process for these materials has been changed.

Application recommendations are based on Dow laboratory testing, evaluation and technical specifications.

Sincerely,

Page 2 of 3

DOW HIGH PERFORMANCE BUILDING AMERICAS ASIA EMEAI


Imagine the Possibilities Sealant Test Lab, DC-4, Lab 3A4 Shanghai Dow Center Parc Industriel – Zone C
consumer.dow.com/Construction 2200 W.Salzburg Road 936 Zhangheng Road B-7180 Seneffe
Auburn, MI 48611 Pudong District, Shanghai Belgium
USA 201203 P. R. China Phone: + 32 (0) 64 511 156
Phone : + 1-800-346-9882 Phone: +86 21 38511100 Fax: +32 (0) 270 62 319
americas.cool@dow.com asia.cool@dow.com emeai.cool@dow.com

General Business
14 March 2022
Document ID: 599209

Peeraphol Chirayucharoensuk
Technical Service & Development

Page 3 of 3

DOW HIGH PERFORMANCE BUILDING AMERICAS ASIA EMEAI


Imagine the Possibilities Sealant Test Lab, DC-4, Lab 3A4 Shanghai Dow Center Parc Industriel – Zone C
consumer.dow.com/Construction 2200 W.Salzburg Road 936 Zhangheng Road B-7180 Seneffe
Auburn, MI 48611 Pudong District, Shanghai Belgium
USA 201203 P. R. China Phone: + 32 (0) 64 511 156
Phone : + 1-800-346-9882 Phone: +86 21 38511100 Fax: +32 (0) 270 62 319
americas.cool@dow.com asia.cool@dow.com emeai.cool@dow.com

General Business

You might also like