By IRS method

1 in 12 Turnout
Gauge= 1673 mm
Crossing number(N)= 12
Angle of crossing (α)= 4°45'49'' 4.763611 0.083141
Switch angle (β)= 0°20'00'' 0.333333 0.005818
Heel divergence(d)= 175 mm
Crossing leg (w) 1877 mm
thickness of switch at toe(t) 0 mm

Radius of lead curve= G-t-wsin(α) sin(α) 0.083045


Cos(β)-cos(α) cos(α) 0.996546
Cos(β) 0.999983
sin(β) 0.005818
1517.12463263714 cot(α+β/2) 22.46757
0.00343727429039098
441374.328745983 mm
say 441360 mm

L Rsin(β) 2567.714 mm
Y G-wsin(α)-R(1-cos(α)) -7.419946 mm

Switch length(SL) (sqrt(2R(d-Y)-(d-Y)*(d-Y))-L


10120.5664259315 mm
say 10125 mm 12692.713911

Lead (G-t-wsinα)cot(α+β/2)+wcosα-Switchlength
25831.6273712354
say 25831 mm
By Cole method BG
curve lead 2GN 1 in 12 40.224
1 in 8.5 28.492

Radius of curve 1.5*G+2*G*N*N 1 in 12 485.202


1 in 8.5 244.696

Switch lead sqrt(2Rd-d*d)


assume d=175 1 in 12 13.03035
assume d=135 1 in 8.5 8.127096
SG
25.83 1 in 9
20.09 1 in 7