Professional Documents
Culture Documents
Data :
Grade of Concrete = M 30
Grade of Steel = Fe 500
Clear cover to Reinforcement = 25.00 mm
References :
1. IS : 456 – 2000 Indian Standard Code of Practice for Plan & Reinforced Concrete
2. IS SP : 16 Design Aids to IS: 456
3. IS SP : 24 Explanatory Handbook on IS: 456
DESIGN OF TWO WAY FLOOR SLAB S1 AND S2:
DATA:-
Grade of Concrete = M 30
Grade of Steel = Fe 500
Clear Cover = 25 mm
Assume thickness of slab = 150.00 mm
Effective depth available = 121.00 mm
Loads Calculations:
Dead Load :
Floor finish load = 1.000 kN/m2
Self weight = 3.750 kN/m2
wDL = 4.750 kN/m2
Imposed Load :
Occupancy classification as per IS: 875(Part 2) - 1987 :
Live load = 5.000 kN/m2
wLL = 5.000 kN/m2
Factord Load w = 1.5(wDL + wLL )= 14.625 kN/m2
DESIGN:-
Ast
Bundary conditions Location BM BM Astreq Spacing
prov.
coeff
Slab S1 Negative moment at
continuous edge along short 8 mm dia.bars
0.035 6.17 119.18 279.25
span @ 180 mm c/c
Ly = 3350
Lx = 3350 Positive moment at midspan
8 mm dia.bars
along short span 0.047 8.28 160.98 279.25
@ 180 mm c/c
Ly/Lx= 1.00
Effective Ly = 3471.00 Negative moment at
continuous edge along long 8 mm dia.bars
0.035 6.17 119.18 279.25
span @ 180 mm c/c
Effective Lx = 3471.00
Two adjacent edges Positive moment at midspan
8 mm dia.bars
discontinuous along Long span 0.047 8.28 160.98 279.25
@ 180 mm c/c
For M30 grade concrete & Fe500 grade steel , Mu, lim / bd2 = 3.990
kNm
kNm
DESIGN OF SLAB : S1
Panel Name : Four edges discontinuous Code : 18
Clear Longer span, ly = 2345 mm
Clear Shorter span, lx = 1380 mm
ly / lx = 1.70 < 2, Hence, Twoway slab.
Effective Longer span = 2441.00 mm
Effective Shorter span = 1476.00 mm
Assume thickness of slab = 125.00 mm
Effective depth available = 96.00 mm
Loads :
Dead Load and Imposed Load (fixed) :
Floor finish = 7.700 kN/m2
Self weight = 3.125 kN/m2
wDL = 10.825 kN/m2
Imposed Load (Not fixed) :
Occupancy classification as per IS: 875(Part 2) - 1987 : Residential
Live load = 2.000 kN/m2
wLL = 2.000 kN/m2
Total load, w = wDL + wLL = 12.825 kN/m2
Span Moments:
Along Shorter span: BM = a x w lx2 = 0.097 x 12.83 x 1.476^2 2.72 kNm Mux1 = 4.08
Along Longer span: BM = a y w lx2 = 0.056 x 12.83 x 1.476^2 1.56 kNm Muy1 = 2.35
Support Moments:
Along Shorter span: BM = a x w lx2 = 0.000 x 12.83 x 1.476^2 0.00 kNm Mux2 = 0.00
Along Longer span: BM = a y w lx2 = 0 x 12.83 x 1.476^2 0.00 kNm Muy2 = 0.00
kNm
kNm
DESIGN OF SLAB : S1
Panel Name : One longer edge discontinuous Code : 6
Clear Longer span, ly = 1380 mm
Clear Shorter span, lx = 900 mm
ly / lx = 1.53 < 2, Hence, Twoway slab.
Effective Longer span = 1476.00 mm
Effective Shorter span = 996.00 mm
Assume thickness of slab = 125.00 mm
Effective depth available = 96.00 mm
Loads :
Dead Load and Imposed Load (fixed) :
Floor finish = 1.200 kN/m2
Self weight = 3.125 kN/m2
wDL = 4.325 kN/m2
Imposed Load (Not fixed) :
Occupancy classification as per IS: 875(Part 2) - 1987 : Residential
Live load = 2.000 kN/m2
wLL = 2.000 kN/m2
Total load, w = wDL + wLL = 6.325 kN/m2
Span Moments:
Along Shorter span: BM = a x w lx2 = 0.052 x 6.33 x 0.996^2 = 0.33 kNm Mux1 = 0.49
Along Longer span: BM = a y w lx2 = 0.028 x 6.33 x 0.996^2 = 0.18 kNm Muy1 = 0.26
Support Moments:
Along Shorter span: BM = a x w lx2 = 0.068 x 6.33 x 0.996^2 = 0.43 kNm Mux2 = 0.64
Along Longer span: BM = a y w lx2 = 0.037 x 6.33 x 0.996^2 = 0.23 kNm Muy2 = 0.35
kNm
kNm
DESIGN OF SLAB : S1
Panel Name : Two adjacent edges discontinuous Code : 8
Clear Longer span, ly = 3430 mm
Clear Shorter span, lx = 3366 mm
ly / lx = 1.02 < 2, Hence, Twoway slab.
Effective Longer span = 3526.00 mm
Effective Shorter span = 3462.00 mm
Assume thickness of slab = 125.00 mm
Effective depth available = 96.00 mm
Loads :
Dead Load and Imposed Load (fixed) :
Floor finish = 1.200 kN/m2
Self weight = 3.125 kN/m2
wDL = 4.325 kN/m2
Imposed Load (Not fixed) :
Occupancy classification as per IS: 875(Part 2) - 1987 : Residential
Live load = 2.000 kN/m2
wLL = 2.000 kN/m2
Total load, w = wDL + wLL = 6.325 kN/m2
Span Moments:
Along Shorter span: BM = a x w lx2 = 0.036 x 6.33 x 3.462^2 = 2.69 kNm Mux1 = 4.04
Along Longer span: BM = a y w lx2 = 0.035 x 6.33 x 3.462^2 = 2.65 kNm Muy1 = 3.98
Support Moments:
Along Shorter span: BM = a x w lx2 = 0.048 x 6.33 x 3.462^2 = 3.61 kNm Mux2 = 5.41
Along Longer span: BM = a y w lx2 = 0.047 x 6.33 x 3.462^2 = 3.56 kNm Muy2 = 5.34
kNm
kNm
DESIGN OF SLAB : S1
Panel Name : Interior Panel Code : 2
Clear Longer span, ly = 3366 mm
Clear Shorter span, lx = 3120 mm
ly / lx = 1.08 < 2, Hence, Twoway slab.
Effective Longer span = 3462.00 mm
Effective Shorter span = 3216.00 mm
Assume thickness of slab = 125.00 mm
Effective depth available = 96.00 mm
Loads :
Dead Load and Imposed Load (fixed) :
Floor finish = 1.200 kN/m2
Self weight = 3.125 kN/m2
wDL = 4.325 kN/m2
Imposed Load (Not fixed) :
Occupancy classification as per IS: 875(Part 2) - 1987 : Residential
Live load = 2.000 kN/m2
wLL = 2.000 kN/m2
Total load, w = wDL + wLL = 6.325 kN/m2
Span Moments:
Along Shorter span: BM = a x w lx2 = 0.027 x 6.33 x 3.216^2 = 1.75 kNm Mux1 = 2.63
Along Longer span: BM = a y w lx2 = 0.024 x 6.33 x 3.216^2 = 1.57 kNm Muy1 = 2.36
Support Moments:
Along Shorter span: BM = a x w lx2 = 0.036 x 6.33 x 3.216^2 = 2.32 kNm Mux2 = 3.48
Along Longer span: BM = a y w lx2 = 0.032 x 6.33 x 3.216^2 = 2.09 kNm Muy2 = 3.14
kNm
kNm
DESIGN OF SLAB : S1
Panel Name : One Short edge discontinuous Code : 4
Clear Longer span, ly = 4845 mm
Clear Shorter span, lx = 2965 mm
ly / lx = 1.63 < 2, Hence, Twoway slab.
Effective Longer span = 4941.00 mm
Effective Shorter span = 3061.00 mm
Assume thickness of slab = 125.00 mm
Effective depth available = 96.00 mm
Loads :
Dead Load and Imposed Load (fixed) :
Floor finish = 1.200 kN/m2
Self weight = 3.125 kN/m2
wDL = 4.325 kN/m2
Imposed Load (Not fixed) :
Occupancy classification as per IS: 875(Part 2) - 1987 : Residential
Live load = 2.000 kN/m2
wLL = 2.000 kN/m2
Total load, w = wDL + wLL = 6.325 kN/m2
Span Moments:
Along Shorter span: BM = a x w lx2 = 0.046 x 6.33 x 3.061^2 = 2.73 kNm Mux1 = 4.10
Along Longer span: BM = a y w lx2 = 0.028 x 6.33 x 3.061^2 = 1.66 kNm Muy1 = 2.49
Support Moments:
Along Shorter span: BM = a x w lx2 = 0.061 x 6.33 x 3.061^2 = 3.59 kNm Mux2 = 5.39
Along Longer span: BM = a y w lx2 = 0.037 x 6.33 x 3.061^2 = 2.19 kNm Muy2 = 3.29
kNm
kNm
DESIGN OF SLAB : S1
Panel Name : One longer edge discontinuous Code : 6
Clear Longer span, ly = 5510 mm
Clear Shorter span, lx = 3366 mm
ly / lx = 1.64 < 2, Hence, Twoway slab.
Effective Longer span = 5606.00 mm
Effective Shorter span = 3462.00 mm
Assume thickness of slab = 125.00 mm
Effective depth available = 96.00 mm
Loads :
Dead Load and Imposed Load (fixed) :
Floor finish = 1.200 kN/m2
Self weight = 3.125 kN/m2
wDL = 4.325 kN/m2
Imposed Load (Not fixed) :
Occupancy classification as per IS: 875(Part 2) - 1987 : Residential
Live load = 2.000 kN/m2
wLL = 2.000 kN/m2
Total load, w = wDL + wLL = 6.325 kN/m2
Span Moments:
Along Shorter span: BM = a x w lx2 = 0.055 x 6.33 x 3.462^2 = 4.18 kNm Mux1 = 6.27
Along Longer span: BM = a y w lx2 = 0.028 x 6.33 x 3.462^2 = 2.12 kNm Muy1 = 3.18
Support Moments:
Along Shorter span: BM = a x w lx2 = 0.072 x 6.33 x 3.462^2 = 5.47 kNm Mux2 = 8.21
Along Longer span: BM = a y w lx2 = 0.037 x 6.33 x 3.462^2 = 2.80 kNm Muy2 = 4.21
kNm
kNm
DESIGN OF TWO WAY FLOOR SLAB (S1) BETWEEN GRID A-B:
Panel Name : Two adjacent edges discontinuous Code : 8
DATA:-
Grade of Concrete M 30
Grade of Steel = Fe 500
Clear Longer span, ly = 3350 mm
Clear Shorter span, lx = 3350 mm
ly / lx = 1.00 < 2, Hence, Twoway slab.
Effective Longer span = 3471.00 mm
Effective Shorter span = 3471.00 mm
Assume thickness of slab = 150.00 mm
Effective depth available = 121.00 mm
Loads Calculations:
Dead Load :
Floor finish load = 1.000 kN/m2
Self weight = 3.750 kN/m2
wDL = 4.750 kN/m2
Imposed Load :
Occupancy classification as per IS: 875(Part 2) - 1987 :
Live load = 5.000 kN/m2
wLL = 5.000 kN/m2