FINAL REPORT

5.12 MONITORING DATA

This section presents the results of the monitoring data that has been collected from the dam
instrumentations. The following instrumentation are being monitored on the Caliraya dam and
dykes, and Lumot dam and dyke (Table 5-1).

Table 5-1: Dam Instrumentation


Caliraya dam Lumot dam
▪ Piezometer ▪ Seepage monitoring weir
▪ Extensometer ▪ Movement survey monuments
▪ Seepage observation wells ▪ Seepage observation wells
▪ Seepage weir
▪ Movement survey monuments
Caliraya west dyke Lumot dyke
▪ Movement survey monuments ▪ Movement survey monuments
▪ Seepage observation wells
Caliraya east dyke
▪ Piezometers
▪ Movement survey monuments

Layout plan of the instrumentation (except the movement survey monuments) are shown in
Figure 5-34 to Figure 5-37.

Figure 5-34: Caliraya Dam Instrumentation Layout

Engineering and Development


Page | 5-24
Corporation of the Philippines
Consulting Services for the Independent Safety
Review of Caliraya and Lumot Dams
FINAL REPORT

Figure 5-35: Caliraya West Dyke Instrumentation Layout

Figure 5-36: Caliraya East Dyke Instrumentation Layout

Engineering and Development


Page | 5-25
Corporation of the Philippines
Consulting Services for the Independent Safety
Review of Caliraya and Lumot Dams
FINAL REPORT

Figure 5-37: Lumot Dam Instrumentation Layout

5.12.1 Seepage

The available seepage data are plotted in Figure 5-38 to Figure 5-42.

Figure 5-38: Plots of Caliraya Seepage 9 Flows Compared with the Reservoir Level
and Rainfall

Engineering and Development