[2] Mechanical Inspection: As per EN ISO 898 (Part-1)
Stress at 0.2 % non- Tensile Strength Description No. of proportional elongation Hardness in HRC Depth of Decarburization (MPa) Pcs. (MPa) Specified Min Checked 800 Min. 640 Min. 22 to 32 0.015 Max. → Max Observation → 05 814-815 651-652 28.2-30.5 Nil
[3] Dimensional Inspection: As per DIN 912
Description No. of Across Head Head Across Major Thread Flat (S) Height (k) Dia. (k) Corner (e) Dia. Total Length Pitch Pcs. Specified Min. Checked 8.02 9.64 15.73 9.15 9.70 → Max 8.17 10.0 16.27 -- 9.95 30.0±0.40 M10x1.5p 8.04 9.85 15.79 9.17 9.85 29.80 Observation → 25 OK 8.08 9.92 15.92 9.20 9.90 29.92
[4] Finish: SELF WITH RPO (Rust Proof Oil)
[5] Visual Inspection as per ISO 6157-PART-1
No surface defect has been observed, Result – Satisfactory. For Capital Bolts & Hardwares