You are on page 1of 5

HX DESIGN TABLES

DESIGN OF HEAT EXCHANGERS

HX DESIGN WITH TABLES

DIN 28184
This standard applies to shell and tube heat exchangers with two fixed heads with inner
tubes and jackets made of unalloyed, alloyed and stainless steels.

DIN 28191
This standard applies to shell and tube heat exchangers with a flanged floating head
with inner tubes and jackets made of unalloyed, alloyed and stainless steels.
np : # of passes n : # of tubes
DESIGN OF HEAT EXCHANGERS Da : Outer diameter nw : # of tubes in baffle window
Di : Inner diameter nacr : # of tubes in cross stream
s : Shell wall thickness A : Surface area per m tube length

HX DESIGN WITH TABLES


SMU : Gap between baffle and shell f : Correction factor
DH : Bundle outer limit VR : Required volumetric flow for 1 m/s velocity on the tube side
B : Baffle spacing = 100 mm VM : Required volumetric flow for 1 m/s velocity on the shell side

Geometrical data :
Tube length : 2.5 m
Tube outer diameter : 25 mm
Tube thickness : 2 mm
Triangular pitch : 32 mm
np : # of passes n : # of tubes
DESIGN OF HEAT EXCHANGERS Da : Outer diameter nw : # of tubes in baffle window
Di : Inner diameter nacr : # of tubes in cross stream
s : Shell wall thickness A : Surface area per m tube length

HX DESIGN WITH TABLES


SMU : Gap between baffle and shell f : Correction factor
DH : Bundle outer limit VR : Required volumetric flow for 1 m/s velocity on the tube side
B : Baffle spacing = 100 mm VM : Required volumetric flow for 1 m/s velocity on the shell side

Geometrical data :
Tube length : 2.5 m
Tube outer diameter : 20 mm
Tube thickness : 2 mm
Triangular pitch : 25 mm

Geometrical data :
Tube length : 2.5 m
Tube outer diameter : 16 mm
Tube thickness : 2 mm
Triangular pitch : 20 mm
DESIGN OF HEAT EXCHANGERS

HX DESIGN WITH TABLES

Geometrical data :
Tube length : 2.5 m
Tube outer diameter : 25 mm
Tube thickness : 2 mm
Triangular pitch : 32 mm

np : # of passes n : # of tubes
Da : Outer diameter nw : # of tubes in baffle window
Di : Inner diameter nacr : # of tubes in cross stream
s : Shell wall thickness A : Surface area per m tube length
SMU : Gap between baffle and shell f : Correction factor
DH : Bundle outer limit VR : Required volumetric flow for 1 m/s velocity on the tube side
B : Baffle spacing = 100 mm VM : Required volumetric flow for 1 m/s velocity on the shell side