Cautions for Servicing SCR Urea Water Pump No.: YEN-CM-23240-2
Subject Dated: May 12 , 2022
(for Quenching and Pump Operation)
Use Marine Main & Aux. SCR
Engine Model All SCR Models
Engine. Nos. -

1.Quenching of Urea Water Pump


The SCR pump unit and dosing unit use the following three types of urea water pump. (For details, please
refer to inspection item and interval of each urea water pump in Table 1.) The urea water pump having no
quenching piping as shown in Fig.1 does not employ quenching. The quenching pipe plug type urea water
pump in Fig.2 and the quenching pipe oiler type urea water pump in Fig.3 employ quenching.
In quenching, the atmospheric air side of mechanical seal is filled with freshwater. This prevent urea water in
mechanical seal from being crystallized and is instrumental in extending the service lie of the mechanical seal.
(For details, please refer to the sectional drawing of the urea water pump in Fig.4.)
The urea water pump quenching pipe and oiler need to be filled with freshwater constantly during both SCR
operation and stoppage. We recommend that the freshwater level be checked every month and re-supply
fresh water when necessary.

【Table 1 Inspection Items and Intervals of each Urea Water Pump】


SCR Inspection Interval
Part to be Item to be
Urea Water Pump Part No. Shipping Time When SCR When SCR
inspected inspected
operated stopped
Fig.1: No Quenching Pipe Type Before Mar. 2021
None None None None
109880-41501
Fig.2: Quenching Pipe Plug Type Mar. 2021~ Check
109811-41060 Apr. 2022 Quenching quenching
1 month 1 month
Fig.3: Quenching Pipe Oiler Type After Apr. 2022 pipe water level /
109811-41061 re-supply
*The urea water pump in Fig.1 has different seal structure. No quenching needs to be implemented.
Remove plug, fill with Remove oiler upper
Has no quenching pipe freshwater, and tighten Quenching pipe cover, fill with fresh
plug added with slit water, and tighten
the cover

Fig.1 Urea Water Pump Fig.2 Urea Water Pump Fig.3 Urea Water Pump
(No Quenching Pipe Type) (Quenching Pipe Plug Type) (Quenching Pipe Oiler Type)
Approved Checked Prepared

YANMAR ENGINEERING CO., LTD.


Market Service Division Takaoka
【Fig.4 Urea Water Pump Section】

*Orange area shows urea water and aqua area shows quenching water (freshwater).

2.Concerning Plug of Quenching Pipe Plug Type Urea Water Pump


When the quenching pipe is filled with freshwater, a small amount of urea water, which would leak from the
mechanical seal, would not crystalize. However, when freshwater in the quenching pipe was lost, a small
amount of urea water whick leaked from the mechanical seal, would crystalize. This will shorten the service
lif of the mechanical seal and untimately will cause urea water that leaked from the mechanical seal, to enter
inside the motor. Since the quenching pipe is fastened, the mechanical seal atomospheric side is airtight.
In this condition, urea water leaked from the mechanical seal of urea water pump, which cannot leak outside
the urea water pump, can enter inside the motor through the motor s oil seal. This can lower the insulation
performance of the motor. By providing a slit measuring 1~2mm in width and 3mm in depth in the
quenching pipe plug, since urea water leaked from the urea water pump, can leak outside the urea water
pump through the quenching pipe plug slit provided by machining, it is possible to prevent urea water from
entering inside the motor. For providing the slit, remove the quenching pipe plug, vice it and machine it
with coping saw, file, etc. For details, please refer to Fig.5 (Quenching Pipe Plug Slit Machining). The
quenching pipe plug having the slit machined is also available from us. When slit machining in the ship is
hard to be made, please contact us at Yanmar Power Technology Co., Ltd. or Yanmar Engineering Co., Ltd.
【Fig.5 Slit Machining to Quenching Pipe Plug】

SCR units having urea water pump (urea water pipe plug
Applicable units type) shipped during Mar. 2021~Apr. 2022
Part No. 109812-41970
(Quenching Pipe Plug having a slit machined)

3.Maintenance of Urea Water Pipe Type (Plug Type & Oiler Type) Urea Water Pump
Mechanical Seal
The mechanical seal and oil seal of urea water pipe type (plug type/oiler type) urea water pump, for
maintaining its performance, needs be replaced on a periodic basis. Although the service life of mechanical
seal and oil seal can vary depending on the installation condition, operation hours, etc. of the urea water
pump, we recommend that the mechanical seal be replaced every 16000 hours or every 2 years of urea
water pump operation, (as far as there will be no leakage from the mechanical seal.)

4.Priming for Quenching Pipe Type Urea Water Pump Operation


Urea water needs to be filled inside the ureawater pump ①when the quenching pipe type (together with
plug type/oiler type) urea water pump is started up for the first time, or ②whenever the pump was
disassembled for servicing.
In this case, remove the plug at the upper body of the urea water pump and resupply urea water inside
the urea water pump. For details, see the urea water pump body plug in Fig.6.
【Fig.6 Urea Water Pump Body Plug】
Plug
Plug