The test certificate summarizes the results of a breaking load test conducted on a scaffolding ledger sample received from M/s EMD scaffolding India(P.)Limited. The sample with dimensions of 48.3 * 3.2mm W.T.* 260mm withstood an applied load of 60 KN without cracking or rupturing at the weld portion, meeting the test observation criteria. The test was conducted in reference to industry standards ASTM A 370 IS 3696 (Part-1 & part II), IS: 2750 ,IS: 4014(Part I & Part II).
The test certificate summarizes the results of a breaking load test conducted on a scaffolding ledger sample received from M/s EMD scaffolding India(P.)Limited. The sample with dimensions of 48.3 * 3.2mm W.T.* 260mm withstood an applied load of 60 KN without cracking or rupturing at the weld portion, meeting the test observation criteria. The test was conducted in reference to industry standards ASTM A 370 IS 3696 (Part-1 & part II), IS: 2750 ,IS: 4014(Part I & Part II).
The test certificate summarizes the results of a breaking load test conducted on a scaffolding ledger sample received from M/s EMD scaffolding India(P.)Limited. The sample with dimensions of 48.3 * 3.2mm W.T.* 260mm withstood an applied load of 60 KN without cracking or rupturing at the weld portion, meeting the test observation criteria. The test was conducted in reference to industry standards ASTM A 370 IS 3696 (Part-1 & part II), IS: 2750 ,IS: 4014(Part I & Part II).
Customer's Name M/s EMD scaffolding India(P.)Limited
E-120, Export Promotion Industrial Park, Site V, Customer's Address. Kasna, Gr. Noida Sample(s) Received on 8/12/2020 Sample(s) Tested on 9/12/2020 Description of Sample Ledger: 48.3 * 3.2mm W.T.* 260mm ReferenceStandard ASTM A 370 IS 3696 (Part-1 & part II), IS: 2750 ,IS: 4014(Part I & Part II) TEST RESULTS Breaking Load Test:- Test ID Applied Load In Test Observation Result Compression BLT1 60 KN The component broken at tube Satisfactory (Axially in material the weld portion Compression) withstood the observed load showing no sign of cracking/rapture Remark:- NA Inspection & Testing Engineers
*** END OF REPORT ***
Notes:- 1. Samples are not drawn by us. 2. Description of the samples is as provided by the party and total liability of work is limited to the invoiced amount. 3. Test samples will be disposed after 30 days of reporting. 4. This report cannot be used as evidence in the court of law without written approval of the lab