TMC BALD EAGLE 29/01/2023

SERVICE REPORT
INCIDENT / DEFECT MACHINERY MAKE

CRANE DOESN’T BOOM IN DECK CRANE. PALFINGER

CAUSE:

BLOCKAGE OF OIL RETURN PASSAGE INSIDE THE BOOM CYLINDER BLOCK

INSPECTION/ ACTIONS TAKE


• After proper reconditioning of the block and the embedded valves inside the block.
• The block and the valves were assembled and mounted back to the crane.
• The oil line plug adapter was replaced with a new one.
• The crane was started, tested, and confirmed okay.

REMARKS:
After reconditioning the boom cylinder block, and installation.
The crane was Started and tested, and all the number of movement and degrees of freedom were
confirmed okay.

PICTORIAL VIEWS

THE BOOM BLOCK PLUG ADAPTER


SOME OF THE EMBEDED VALVES
PART OF THE HYDRAULIC CIRCUIT

BOOM IN POSITION
CRANE IN DEAD POSITION

BOOM OUT POSITION


COMPILLED BY: AMADI WISDOM (ASST. PORT ENGR.)
WORKDONE BY: AMADI WISDOM (ASST. PORT ENGR.) APPROVED BY: