Fault Sheet: Cause Vs Solution
Fault Sheet: Cause Vs Solution
Cause vs Solution
CAUSES SOLUTION
Security chain Ensure that the security chain has not been opened before finishing the
movement (for example, due to the limit switch).
PBCM
Distance CO for 1. Make sure that the Distance CO in the CTC 3.4.3 menu matches the real
speed change magnet position in the shaft.
Encoder 1. In CTC2.3.3 menu check the CurPos variable, and move the lift a known
counting signal distance in emergency mode.
© Copyright Orona 2021
• When going up, it starts from 2000mm and the value should increase
the same distance the lift moves.
• When going down, it starts from a very high value and it should
decrease the same distance the lift moves.
2. Check if Centi.mm/pulse value configured in CTC 3.4.6 menu corresponds
with the installed speed governor (114 L-80 Orona, 126 L-250 Orona).
3. If everything above is correct, change speed governor encoder.