* Data
Mass of roof plate and rafter m = 3610 kg *(from strength calc.)
Web sling 3 ton n1 = 5 pcs
Web sling 5 ton n2 = 3 pcs
Web sling 3 ton capacity mc_3 = 3000 kg
Web sling 5 ton capacity mc_5 = 5000 kg
Safety weight limit 120% SWL = 4332 kg
Total lifting lug = 8 pcs
Mass distribution per lifting lug ml = 541.5 kg
Force distribution per lifting lug Fl = 5306.7 N
Web sling 3 ton length r_3 = 6000 mm
Web sling 5 ton length r_5 = 6000 mm
Radius lifting lug x = 2016 mm
Safety factor sf = 75%
Specific gravity g = 9.8 N/kg
Sin Ɵ = x/r_5
Ɵ = Arc. Sin (X/r_5)
Ɵ = 19.63336
* Force on sling 3 ton
F_3 = mc_3*g*Cos Ɵ
= 27690.74 N
* Data
Tensile streght of welding consumable Y = 380 MPa
Allowable tensile stregth 2/3Y = 253.3333 MPa
Area of weld per pad A = 2904 mm^2
Total pad = 8
Total area of weld per pad At = 23232 mm^2
Force of roof and rafter F = 35378 N
* Pressure on Weld
P = F/At
= 1.522813 MPa
Detail
Lifting Radius = 12000 mm
Boom Length = 31015 mm
Weight Capacity on Chart = 8600 kg
Weight to be lifted = 3610 kg
SWL 120% = 4332 kg