Professional Documents
Culture Documents
Page 1 of 8
FIRE RISK ASSESSMENT
Reference No.: KAFD-RY-RIA1-PGEN-SAB-HSE-RAS-00000
Description: Risk Assessment - Workshop Date: 01/Jul/2020
Revision No.: 00
Risk Rating Final Residual Risk Rating
Responsible
Source Hazard Impact Hazards Controls
Person
S L RR Category S L RR Category
➢ Access pathways of equipment
must be cleared from any
obstruction.
➢ Lifting equipment will be properly
checked if it is safe to use.
➢ During unloading of materials,
ensure materials are properly
secured.
➢ Ensure workers were trained
about manual handling
technique.
➢ Time Delays,
➢ Material shall be stored in a
➢Hit by equipment ➢ Financial loss
covered / dry space at all the
➢Hit by material ➢ Product loss
(Unloading, time.
➢Poor storage area ➢ Fire, property Job Supervisor
shifting, material High ➢ Storage should be in a clean, dry,
➢Improper stacking damage 4 4 16 2 1 2 Low Risk
handling & Risk “NO SMOKING” area and should SHE Representative
of materials ➢ Slips, trips,
storage) be restricted to access by
➢ Poor manual abrasions,
authorized personnel only.
handling strains and
➢ Storage shall be in cool place and
sprains
in condition no humidity and
moisture.
➢ Thermal insulation shall be
transported to the site by the
contractor, in the appropriate
vehicle such that no damage is
done during transportation
➢ The storage area must be flat,
the ground must not be marshy
or unstable and it must not
contain any corrosive material.
➢ Use correct tools for the job. Do
➢ Not inspected or
not use a tool or attachment for
defective power
➢ Time Delays, something it was not designed to.
tools
➢ Financial loss ➢ Inspect tools for visible damage
➢ Improper
➢ Product loss prior to use. Job Supervisor
connectors or
3. POWER/HAND Hand, eye and foot High ➢ All power tools undergo a
damage cables 4 4 16 SHE Representative 2 1 2 Low Risk
TOOL USAGE injury Risk servicing program in line with
➢ Using improper
Back injury, fire, their manufacturer’s guidelines
tool for the
damage to and must be inspected monthly
job/work and
property due to by competent person and
improper using of
fire. suitable storage area shall be
tools
provided.
Page 2 of 8
FIRE RISK ASSESSMENT
Reference No.: KAFD-RY-RIA1-PGEN-SAB-HSE-RAS-00000
Description: Risk Assessment - Workshop Date: 01/Jul/2020
Revision No.: 00
Risk Rating Final Residual Risk Rating
Responsible
Source Hazard Impact Hazards Controls
Person
S L RR Category S L RR Category
➢ Injuries due to ➢ All power tools user must be
sharp object/edges trained and proof of training be
➢ Trailing cables kept for reference.
Untrained for the ➢ Only trained and competent
tools persons to use, test, repair and
maintain power tools.
➢ Keep all guards in place. Cover
exposed belts, pulley, gears, and
shafts that could cause injury.
➢ Never reach over equipment
while it is running.
➢ Keep bystanders away from
moving machinery.
➢ Use quality tools in accordance
with the type of work to carry out
(calibrated if required).
➢ When not in use, make sure that
hand or power tools are stored in
a manner unlikely to be
hazardous to others. Use boxes
or other suitable containers.
➢ All electrical power tools must be
double insulated. Power tools
must have handles and fit-for-
purpose working platform for the
operators shall be provided.
PTW/exclusion zones underneath
shall be effectively enforced
where needed.
➢ Only competent person shall be
assigned for the task.
➢ Wear steel-toe safety shoes, slip
➢ Inexperience
resistant footwear and keep
workers ➢ Time Delays,
areas dry, clean and
➢ Slip, trip wet ➢ Financial loss Job Supervisor
4. BENDING High unobstructed, as much as
surface ➢ Aggravate injury 4 4 16 2 1 2 Low Risk
ACTIVITY Risk possible SHE Representative
➢ Equipment failure ➢ Property
➢ All debris to be put in waste skips
➢ Pinch point Damage
on a continuous basis to avoid
debris blowing around project.
➢ Any obstructions from pathways
must be removed.
Page 3 of 8
FIRE RISK ASSESSMENT
Reference No.: KAFD-RY-RIA1-PGEN-SAB-HSE-RAS-00000
Description: Risk Assessment - Workshop Date: 01/Jul/2020
Revision No.: 00
Risk Rating Final Residual Risk Rating
Responsible
Source Hazard Impact Hazards Controls
Person
S L RR Category S L RR Category
➢ Workers in or around the area will
wear dust masks.
➢ Verify all guarding is in place and
effective.
➢ Personal Protective Equipment:
Heavy-duty gloves, metacarpal
guards, forearm guards, etc.
➢ Pre-work inspection: Identify
potential pinch points before
starting work
Page 5 of 8
FIRE RISK ASSESSMENT
Reference No.: KAFD-RY-RIA1-PGEN-SAB-HSE-RAS-00000
Description: Risk Assessment - Workshop Date: 01/Jul/2020
Revision No.: 00
Risk Rating Final Residual Risk Rating
Responsible
Source Hazard Impact Hazards Controls
Person
S L RR Category S L RR Category
shall be used for the storage
and handling of flammable and
combustible liquids.
➢ Approved, properly labeled,
storage cabinets (or properly
labeled drums) shall be used to
store flammable liquids in
excess of 15 US Gallons (57
litres).
➢ Permanent fuel storage tanks
shall be maintained in a bunded
area, with provisions made for
the handling of spills and
groundwater protection.
➢ All fuel lines will be equipped
with valves capable of stopping
the flow of fuel at source, and
all piping valves and fittings
shall be capable of
withstanding working
pressures compatible with the
type of liquid being stored.
➢ All permanent fuel storage
tanks and dispensing units
shall be protected against
collision damage.
➢ Flammable chemicals shall be
stored & handled as per MSDS
recommendations.
Page 6 of 8
FIRE RISK ASSESSMENT
Reference No.: KAFD-RY-RIA1-PGEN-SAB-HSE-RAS-00000
Description: Risk Assessment - Workshop Date: 01/Jul/2020
Revision No.: 00
Risk Rating Final Residual Risk Rating
Responsible
Source Hazard Impact Hazards Controls
Person
S L RR Category S L RR Category
➢ Be familiar with emergency
response procedure.
➢ Any obstructions from pathways
➢ Obstructed must be removed.
accesses ➢ Emergency contact lists shall be
➢ Lack of illumination posted at site. PARCEL
and emergency exit ➢ Time Delays, ➢ Ensure lightings at the stairways Responsible
EMERGENCY
signs ➢ Financial loss High and emergency exits are working
RESPONSE/ACCESSE 4 4 16 Engineer 2 1 2 Low Risk
➢ Late response to ➢ Aggravate Risk properly. Emergency lights shall
S/ILLUMINATION HSE Representative
victim in case of injury be installed at stairs to evacuate
emergency in case of power supply failure or
➢ Lack of emergency.
communication ➢ Emergency evacuation routes
and procedure shall be reminded
regularly to the site staff by
construction and SHE team.
CLASSIFICATION CHART
Likelihood of Risk Description Rating Severity of Risk Description Rating
Unlikely Occurrence close to zero 1 Minor Injury First-Aid On Site 1
May Happen Capable of taking Place 2 Minor Injury Treatment Off Site 2
Likely Tend to or Inclined to Occur 3 Up-to-3 days Injury Limited or no work for three days 3
Very Likely High Inclination of Occurrence 4 Major Injury Reportable 4
Most Definitely Happen- Not “If but
Certain 5 Death 5
When”
Date:
Prepared by: Jimvil Villeza Signature:
01/07/2020 Consultant
Date: Approved by:
Reviewed by: Fahim Shaikh Signature:
01/07/2020
Page 7 of 8
FIRE RISK ASSESSMENT
Reference No.: KAFD-RY-RIA1-PGEN-SAB-HSE-RAS-00000
Description: Risk Assessment - Workshop Date: 01/Jul/2020
Revision No.: 00
Risk Rating Final Residual Risk Rating
Responsible
Source Hazard Impact Hazards Controls
Person
S L RR Category S L RR Category
Date:
Approved by: Ekrem Ucar Signature: HSE Manager Date
01/07/2020
Page 8 of 8