You are on page 1of 2

MA4304, description and measuring

Show All Profiles

Valid for serial numbers


Model Production site Serial number start Serial number stop
A60H Volvo

Op nbr 302-0035

Tools:
88890074 Multimeter
9998699 Adapter
9990062 Cable
88890167 Break out harness
88830139 Break out harness

Description

Function The valve controls gearshifting in the dropbox, neutral


position
References Wiring diagram WD402
Component location 6
Tech Tool
tests
Miscellaneo
us
VB75, signal neutral position

Control measurement

Measuring point Correct value Condition Test method


≈0Ω
3–
On adapter: 49 –

1–3 ≈ 320 KΩ
On adapter: 47 – 49

≈∞Ω
1–
On adapter: 47 –

3–
On adapter: 49 –

Verification measurement

Measuring point Correct value Condition Test method


≈ U bat
1– (active)
On adapter: 47 – ≈ 0V
(inactive)