BUILDING PLAN APPROVAL SYSTEM

SCRUTINY REPORT

PROPOSAL DETAILS

1 Application Number : -
2 Date of receipt of Application : -

3. ARCHITECT DETAILS

i) Name : Sanjay Nautiyal


Steet No.7 Kaulagarh road, Rajendra nagar
ii) Address :
dehradun
iii) Mobile Number : 9536756646
iv) Email :
v) LBD Number : E/36/2019
vi) Issue Date : 13/09/2020
vii) Valid Upto : 28/10/2020

4. PROJECT DETAILS

BUILDING 1

i) Building Category : Low Rise Buildings


ii) Project Type : New Construction
iii) Zone : Plain Areas Under Municipal Limits
iv) Classification : Main
v) Land Use Category : Residential Buildings
vi) Project Category : Single Residential Plot
vii) Proposed Start Date : 09/10/2020
viii) Proposed End Date : 09/10/2020
ix) Number of Dwelling Units : -
x) Total Area Covered in all floors : -

BUILDING DETAILS

Building Basement Ground Upper Building Height


Stilt
Name Floor(s) Floor Floor(s) (Metre)

Document generated by AutoPlan 6.7.0 1 Generated on : 26-10-20 10:00:25 PM


Kamal Devrari - 1 1 - 6.00

5. LAND DETAILS

TYPE OF LAND
LAND 1

i) Type of Land : -
ii) Taluk : Methi Beri
iii) Name of City / Town / Village : Methi Beri
iv) Khata Number : 136
v) Revenue Plot Number : kharsa No 171
vi) As per Plan : 375.09 (Square Metre)
vii) Area of Plot : 376.39 (Square Metre)
viii) Area Under Possession : -
ix) Survey Number : -
x) Property ID : -

6. CO-ORDINATES AND DISTANCE STATEMENT

A) SITE

Co-ordinates

Vertex X Y Z
1 200.834292983305 20.7794469330118 0
2 214.544292983305 20.7794469330118 0
3 214.544292983305 48.2184469330118 0
4 200.834292983305 48.2184469330118 0

Note :
Co-ordinates shown above are based on values provided by the applicant in False Easting/Northing.

Distance

Segment (Vertex to Vertex) Distance (Metre)


1-2 13.71
2-3 27.44
3-4 13.71
4-1 27.44

Document generated by AutoPlan 6.7.0 2 Generated on : 26-10-20 10:00:25 PM


7. FSI/FAR

A) Site Area Statement

i) Neighbouring Details

Side Type Neighbouring Details


Front Road(s) 29ft
Left Plot(s) 31 32
Right Plot(s) 48
Rear Plot(s) 35 36

ii) Site Details

1) Gross Site Area : 376.19 (Square Metre)


2) Net Site Area : 375.09 (Square Metre)
3) Gross Site Width : 13.71 (Metre)
4) Net Site Width : 13.71 (Metre)
5) Gross Site Depth : 27.44 (Metre)
6) Net Site Depth : 27.36 (Metre)

iii) Site Area as per Document

1) Site Area as per Document : 376.39 (Square Metre)

B) Plot Area

Minimum Required Provided


Result
(Square Metre) (Square Metre)

- 375.09 NOT APPLICABLE

Rule Clause(s)
1) MinimumPlot Area - Clause 4.2 of Uttarakhand Bye Laws and Regulations

2) Habitat Centre - Clause 7.13 of Uttarakhand Bye Laws and Regulations

3) FarmHouse -Chapter VII - Clause 7.17 of Uttarakhand Bye Laws and Regulations

4) Dairy Farm-Chapter VII - Clause 7.18 of Uttarakhand Bye Laws and Regulations

5) Ropeways Terminal Buildings -Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

6) Constructed Area - Clause 7.1 of Uttarakhand Bye Laws and Regulations

7) Filling Station / Filling CumService station -Chapter VII - Clause 7.14 of Uttarakhand Bye Laws and Regulations

C) FAR Area

Maximum Permissible Provided


Result
(Square Metre) (Square Metre)

562.64 273.22 ACCEPTED

D) FAR Ratio

Maximum Permissible Provided Result

Document generated by AutoPlan 6.7.0 3 Generated on : 26-10-20 10:00:25 PM


1.50 0.73 ACCEPTED

Rule Clause(s)
1) Ground Coverage and FAR - Clause 5.5 of Uttarakhand Bye Laws and Regulations

2) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

3) Old Cinema - Clause 7.10 of Uttarakhand Bye Laws and Regulations

4) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

5) Filling Station / Filling CumService station -Chapter VII - Clause 7.14 of Uttarakhand Bye Laws and Regulations

E) Plot Width

Minimum Required Provided


Result
(Metre) (Metre)

- 13.71 NOT APPLICABLE

Rule Clause(s)
1) Multiplex - Clause 7.9 of Uttarakhand Bye Laws and Regulations

2) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

3) Habitat Centre - Clause 7.13 of Uttarakhand Bye Laws and Regulations

4) Constructed Area - Clause 7.1 of Uttarakhand Bye Laws and Regulations

F) Plot Depth

Minimum Required Provided


Result
(Metre) (Metre)

- 27.36 NOT APPLICABLE

G) Frontage

Minimum Required Provided


Result
(Metre) (Metre)

- 13.71 NOT APPLICABLE

Rule Clause(s)
1) Dairy Farm-Chapter VII - Clause 7.18 of Uttarakhand Bye Laws and Regulations

H) Plot Area Ratio

Minimum Required Provided Result


1.00 : 3.50 1.00 : 2.00 ACCEPTED

Rule Clause(s)
1) Definitions - Chapter II of Uthrakhand Bye Laws and Regulations

I) Built-up Area Statement

Building Name - Kamal Devrari

Gross Built-up Net


Gross FAR Area
Area Area Deductions
Floor Name Floor Uses Deductions (Square
(Square (Square (Square
(Square Metre) Metre)
Metre) Metre) Metre)

GROUND
Residential 173.68 0.00 173.68 0.00 173.68
FLOOR
Document generated by AutoPlan 6.7.0 4 Generated on : 26-10-20 10:00:25 PM
FLOOR 1 Residential 112.77 0.00 112.77 13.23 99.54
Roof / Open
ROOF 112.77 112.77 0.00 0.00 0.00
Terrace Floor
Total 399.22 112.77 286.45 13.23 273.22

8. FLOORS

A) Number of Floors Above Ground

Building Name - Kamal Devrari

Maximum Permissible Provided Result


3 1 ACCEPTED

Rule Clause(s)
1) Height of Building - Chapter V - Clause 5.1of Uthrakhand Bye Laws and Regulations

2) Eco Resorts - Clause 7.6 of Uttarakhand Bye Laws and Regulations

3) FarmHouse -Chapter VII - Clause 7.17 of Uttarakhand Bye Laws and Regulations

4) Dairy Farm-Chapter VII - Clause 7.18 of Uttarakhand Bye Laws and Regulations

9. GROUND COVERAGE

A) Building Coverage Area

Maximum Permissible Provided


Result
(Square Metre) (Square Metre)

206.30 173.68 ACCEPTED

Rule Clause(s)
1) Ground Coverage and FAR - Clause 5.5 of Uttarakhand Bye Laws and Regulations

2) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

3) Old Cinema - Clause 7.10 of Uttarakhand Bye Laws and Regulations

4) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

B) Building Coverage Percentage

Maximum Permissible Provided Result


55.00 46.30 ACCEPTED

Rule Clause(s)
1) Ground Coverage and FAR - Clause 5.5 of Uttarakhand Bye Laws and Regulations

2) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

3) Old Cinema - Clause 7.10 of Uttarakhand Bye Laws and Regulations

4) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

C) Coverage Details

Gross Building Coverage Area Deduction Net Building Coverage Area


Building Name
Document generated by AutoPlan 6.7.0 5 Generated on : 26-10-20 10:00:25 PM
Building Name
(Square Metre) (Square Metre) (Square Metre)

Kamal Devrari 173.68 - 173.68

10. ROAD/STREET

A) Road Width

Minimum Required Provided


Type Name Result
(Metre) (Metre)

Proposed 29ft 9.00 9.00 ACCEPTED

Rule Clause(s)
1) Site development parameters for building projects other than township - Chapter IV of Uttarakhand Bye Laws and Regulations

2) FarmHouse -Chapter VII - Clause 7.17 of Uttarakhand Bye Laws and Regulations

3) Dairy Farm-Chapter VII - Clause 7.18 of Uttarakhand Bye Laws and Regulations

4) Farmer Service Centre -Chapter VII - Clause 7.15 of Uttarakhand Bye Laws and Regulations

5) Ropeways Terminal Buildings - -Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

6) Filling Station / Filling CumService station -Chapter VII - Clause 7.14 of Uttarakhand Bye Laws and Regulations

B) Road Details

Existing Width Proposed Width Building Line


Road Name
(Metre) (Metre) (Metre)

29ft 8.84 9.00 -

Note :
Building line value shown in the scrutiny report is as per the data provided / selected by the Technical person during the drawing preparation. Auto
Plan Verify do not performa validation check on the same. Manual verification / comparison for Building Line should be performed by the Site
Inspector during Site Inspection.

C) Distance from Site to Road

Road Width Distance


Road Type Road Name Direction wrt Site
(Metre) (Metre)

Proposed 29ft Front 9.00 0.00

11. SETBACK

A) Front

Building Name - Kamal Devrari

Minimum Required Provided


Floor Name Result
(Metre) (Metre)

GROUND FLOOR 4.50 6.45 ACCEPTED

Rule Clause(s)
1) Exterior open spaces/setbacks - Clause 5.2 of Uthrakhand Bye Laws and Regulations

2) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

3) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations
Document generated by AutoPlan 6.7.0 6 Generated on : 26-10-20 10:00:25 PM
4) Constructed Area - Clause 7.1 of Uttarakhand Bye Laws and Regulations

B) Side 01

Building Name - Kamal Devrari

Minimum Required Provided


Floor Name Result
(Metre) (Metre)

GROUND FLOOR 1.50 1.50 ACCEPTED

Rule Clause(s)
1) Exterior open spaces/setbacks - Clause 5.2 of Uthrakhand Bye Laws and Regulations

2) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

3) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

4) Filling Station / Filling CumService station -Chapter VII - Clause 7.14 of Uttarakhand Bye Laws and Regulations

C) Side 02

Building Name - Kamal Devrari

Minimum Required Provided


Floor Name Result
(Metre) (Metre)

GROUND FLOOR - 1.41 NOT APPLICABLE

Rule Clause(s)
1) Exterior open spaces/setbacks - Clause 5.2 of Uthrakhand Bye Laws and Regulations

2) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

3) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

D) Rear

Building Name - Kamal Devrari

Minimum Required Provided


Floor Name Result
(Metre) (Metre)

GROUND FLOOR 3.00 3.71 ACCEPTED

Rule Clause(s)
1) Exterior open spaces/setbacks - Clause 5.2 of Uthrakhand Bye Laws and Regulations

2) New Cinema Hall - Clause 7.11 of Uttarakhand Bye Laws and Regulations

3) Ropeways Terminal Buildings - Chapter VII - Clause 7.21 of Uttarakhand Bye Laws and Regulations

4) Filling Station / Filling CumService station -Chapter VII - Clause 7.14 of Uttarakhand Bye Laws and Regulations

12. BUILDING HEIGHT

A) Building Height

Building Name - Kamal Devrari

Maximum Permissible Provided


Result
(Metre) (Metre)

9.00 6.00 ACCEPTED


Document generated by AutoPlan 6.7.0 7 Generated on : 26-10-20 10:00:25 PM
Rule Clause(s)
1) Height of Building - Chapter V - Clause 5.1of Uthrakhand Bye Laws and Regulations

2) Eco Resorts - Clause 7.6 of Uttarakhand Bye Laws and Regulations

3) Old Cinema - Clause 7.10 of Uttarakhand Bye Laws and Regulations

4) FarmHouse -Chapter VII - Clause 7.17 of Uttarakhand Bye Laws and Regulations

5) Dairy Farm-Chapter VII - Clause 7.18 of Uttarakhand Bye Laws and Regulations

6) Constructed Area - Clause 7.1 of Uttarakhand Bye Laws and Regulations

13. PLINTH

A) Height of the Plinth

Building Name - Kamal Devrari

Provided
Floor Name Result
(Metre)

GROUND FLOOR 0.45 NOT APPLICABLE

14. RAIN WATER HARVESTING

A) Total Capacity of Rain Water Storage Tanks

Minimum Required Provided


Result
(Cubic Metre) (Cubic Metre)

2.00 6.75 ACCEPTED

Rule Clause(s)
1) Rain Water Collection Standard -Chapter VI - Clause 6.5 of Uttarakhand Bye Laws and Regulations

15. WATER TANK

A) Volume of Water Tank

Minimum
Building Provided
Type Name Location Required Result
Name (litres)
(litres)

RWH Storage RWH Storage Ground NOT


- 3375.00
Water Tank Water Tank 1 Level APPLICABLE
RWH Storage RWH Storage Ground NOT
- 3375.00
Water Tank Water Tank 2 Level APPLICABLE

B) Height of Water Tank

Minimum
Building Provided
Type Name Location Required Result
Name (Metre)
(Metre)

RWH Storage RWH Storage Ground NOT


- 1.50
Document generated by AutoPlan 6.7.0 8 Generated on : 26-10-20 10:00:25 PM
- 1.50
Water Tank Water Tank 1 Level APPLICABLE
RWH Storage RWH Storage Ground NOT
- 1.50
Water Tank Water Tank 2 Level APPLICABLE

16. ECS PARKING

A) Number of ECS

Minimum Required Provided Result


3 3 ACCEPTED

Rule Clause(s)
1) Parking -Clause 5.6 of Uthrakhand Bye Laws and Regulations As per GO 5 Feb 2019

VERIFICATION ITEMS LISTED BELOW ARE NOT MARKED/SHOWN/LAYERED IN


THE DRAWING

17. MEANS OF ACCESS

Length of Means of Access


Width of Means of Access

18. SETBACK

Distance between Buildings

19. PARKING
Parking Area

20. BASEMENT
Height of Basement
Number of Basement
Projection of Basement
Front Setback of Basement
Left Setback of Basement
Right Setback of Basement
Rear Setback of Basement

21. STAIRCASE

Staircase Width
Riser Height
Tread Width
Number of Steps Per Flight
Handrail Height

22. PROJECTION IN OPEN SPACE


Document generated by AutoPlan 6.7.0 9 Generated on : 26-10-20 10:00:25 PM
Width of Projection

23. LIFT
Lift Width
Lift Depth
Lift Door Width
Number of Passengers

24. ROOM SIZE


Room Area
Room Width
Room Height

25. RAMP
Width of Ramp
Slope of Ramp

26. OPEN SPACE AND VENTILATION SHAFT

Width of Open Space and Ventilation Shaft


Area of Open Space and Ventilation Shaft

27. BOUNDARY WALL

Height of Boundary Wall

28. MEZZANINE FLOOR


Mezzanine Floor Allowed
Clear Height of Mezzanine Floor

29. PORCH
Porch Width
Porch Length

30. PLANTATION
Area of Plantation
Percentage of Plantation

31. PHYSICALLY CHALLENGED

Width of Access Path


Slope of Access Path
Tread Width in Steps
Riser Height in Steps
Width of Entry Gate / Exit Gate
Width of Passage Connecting Entry and Exit Gate
Slope of Passage Connecting Entry and Exit Gate
Document generated by AutoPlan 6.7.0 10 Generated on : 26-10-20 10:00:25 PM
Width of Toilet
Depth of Toilet
Width of Toilet Gate

32. TRAVEL DISTANCE

Travel Distance

33. STRUCTURES ABOVE TERRACE LEVEL

Structures Above Terrace Level

34. LOFT
Loft Clear Height

35. ACCESSORY BUILDINGS


Area of Accessory Building
Height of Accessory Building

36. DRIVEWAY
Width of Driveway
Inner Turning Radius
Outer Turning Radius

37. EWS / LIG / LMIG UNITS

Number of EWS Units


Percentage of EWS Units

38. DENSITY

Density of Dwelling Units

Rules and Regulations Referred

Uttarakhand Building Bye Laws and Regulations -2011 (Amendment 2016)


Disclaimer
This scrutiny report is only an indicative document. The status of Accepted/Not-Accepted against the parameters doesn’t mean an
approval or rejection of the application submitted whatsoever. There may be other parameters from DCR or administrative parameters not
covered under this scrutiny report or not marked or highlighted by applicant or Architect in their drawing which are at the same time,
essential to be evaluated by the Office for a formal and final approval or rejection by the competent authority.
This report is generated by the system and reflects only the result of scrutinized parameters based on the submitted drawing.
Drawing Name : NTD09102020MDDADEVRARIJI.dwg
File Date : 16-10-2020
The disclosure, marking and correctness of the drawing is sole responsibility of the applicant and the technical person. The system in no
way shall be liable for erroneous marking of boundaries, and other such objects in the drawing.

Document generated by AutoPlan 6.7.0 11 Generated on : 26-10-20 10:00:25 PM