TECHNICAL PARAMETERS

Working voltage 9 16V DC


Working current 28mA(12V DC)
OUTDOOR DUAL PASSIVE Detecting range wide-angle lens 12m, curtain lens 8m
Detecting angle wide-angle lens 110 , curtain lens 15
INFRARED DETECTOR
Sensor type dual element low-noise pyroelectric infrared sensor
Warm-up time 60 sec
Pulse count wide-angle 1P and 2P optional, curtain 1P only.
Installation wall hanging
Mount height optimal height 2.2m
Operating temperature -10 ~50 (14 122 )
Relay output N.C./N.O. optional, contact rating 28VDC, 80mA
Anti-tamper switch N.C. without voltage output, contact rating 28VDC,100mA
Size 150mm 73mm 48mm

WIDE-ANGLE DETECTING RANGE FIGURES

8 m
6

4
This product complies with standards of People's Republic of China:
GB10408.1-2000 and GB10408.5-2000. 2
0
Outdoor dual passive infrared detector works based on infrared
spectrum of human body. The product uses special filter lens and 2
adopts advanced signal analysis technology, and it is provided
with waterproof to be suitable for outdoor usage. This product 4
can be used for banks, housewares and homes etc. 6
8
GENERAL VIEW 0 2 4 6 8 10 12 m Top view

9
2.2m
1

2 1. LED
3 2. Dual element pyroelectric infrared sensor
4 3. Shield for sensor
8 4. RELAY jumper
5 1.5 2 4 6 8 10 12 m
5. P.COUNT jumper
2 6. Post head Side view
3 7. Wire outlet
6 6 8. Anti-tamper switch
7 9. PCB clamp
9
CURTAIN DETECTING RANGE FIGURES

1. LED
2. Lens
0m 8m
Top view

0m 4m 8m
MAIN FEATURES
Adopt microprocessor
Special filter lens, white light immunity 10000 Lux
Bug guard
Wide-angle lens and curtain lens optional for different locale 2.2m
Collect signals by dual sensor to false alarm prevention
LED ON/ OFF optional, pulse count optional
Temperature auto-compensation to adapt environment
change
Alarm output N.C./N.O. optional to adapt different alarm
system Side view
Pet (<20Kg) immunity
USAGE 2
1. Connect 12VDC power supply, warm up with indicator flashing,
indicator stops flashing after 60 sec and detector enters
normal monitoring state. fetch 6 waterproof pads,
2. Test by normal walk speed in detection range, indicator is on loose screws, open top
and detector shall alarm. After 5 sec, indicator is off and cover, and connect power
detector shall enter monitoring state again. line.
3. RELAY jumper is used to set alarm output state, user can
select different output state according to various alarm system,
select 1&2 for N.C.(Normal Closed) state and 2&3 for
N.O.(Normal Open) state. N.C. state is set in factory setting.
4. P.COUNT jumper is used to select pulse count. Select 1&2 for
first class pulse, which is suitable for general outdoor
environment; select 2&3 for second class pulse, which is 3
suitable for atrocious outdoor environment.
5. LED jumper is to control LED indicator, which will not influence
normal output of detector. LED is set to be able in factory close top cover, tighten
setting. screws and put in 6
waterproof pads.
INSTALLATION LOCATION AND NOTICES
1. Detector should not be mounted in the area as below:
Area where vehicle pass through.
Area which has objects easy to be blowed by wind, such as
swing sign, tree etc.
2. Avoid mounting detector in the area close to objects changing 4
temperature easily, such as air-condition.
3. No obstacle in front of the lens of detector, or it will influence
detecting effect.
4. Detector should be mounted where detector can induce
inbreak, the best bet is that intruder cross over the detecting plug waterproof pads in
area. We suggest the optimal mount height is 2.2m. wire outlet and fix them.
5. Indicator should be mounted on the top of lens when mounting
detector.
waterproof
6. Unwanted wires should not be put into detector.

INSTALLATION
1. Fetch slide carriage from detector. 5
2. If mounting detector on the wall, fix slide carriage on the wall
by screws; if mounting detector at the corner of wall, knock out
4 mount holes on slide carriage, then fix slide carriage by
screws.
3. Take out 6 waterproof pads from the bottom of detector and 6
screws. up up
4. Open the top cover of detector, connect wires according to
Terminal block figure, close top cover of detector, firmly
tighten screws, then mount 6 waterproof pads. down down
5. Plug waterproof pads in wire outlet and fix them.
6. Fix detector in slide carriage, unwanted wires should be put in
wire notch of slide carriage.

TERMINAL BLOCK FIGURE wall mounted corner mounted


encase detector in slide carriage according to the arrow
direction.

6
+12V: anode of DC power
GND: cathode of DC power
ALARM: relay output terminal
TAMPER: anti-tamper switch terminal
TAMPER +12V GND ALARM

INSTALLATION FIGURES

1
finish mounting.

NOTICES
1. Please mount and use according to this manual, do not touch
the surface of sensor, if detector need to be cleaned, use soft
cloth with alcohol to clean after turning off power.
2. Yearly testing is required to ensure proper operations of this
detector.
3. Though this product can reduce accident, but it do not ensure
wall mounted with Corner mounted with perfectly safe. You should enhance security consciousness in
slide carriage slide carriage daily life besides using this product for your security.