13.8 SOCIO-CULTURAL FACILITIES


Table 13.16: Planning Norms and Standards for Socio-Cultural Facilities

Sl. Population / unit


Category Plot Area
No. (approx.)
1 a) Banquet Hall 10000 800-2000 sqm
b) Multipurpose Community Hall which may include 1.0 lakh 2000 sqm
provision for marriages, small public gathering,
function, eating joint, and library etc.
2 a) Community Recreational Club 1.0 lakh 2000 sqm
b) Recreational Club 5.0 lakh 5000 sqm
3 Socio-cultural activities such as auditorium, music, 1.0 lakh 1000 sqm
dance & drama centre/ meditation & spiritual centre etc.

4 Exhibition cum-Fair Ground 2 sites in new Upto 40 ha. Each


urban extension
5 Science Centre 10.0 lakh As per requirement
6 International Convention Centre City Level As per requirement
1 Socio-Cultural Centre Sub-City Level As per Requirement]
[7
[7

Table 13.17: Development Controls for Socio-Cultural Facilities

Sl. Maximum
Category Ground Other Controls
No. Coverage
FAR Height

1 a) Multipurpose 30% 120 26 m 1. Parking standard @ 3.0 ECS /


Community Hall 100 sq m of floor area.
2. Other controls related to
b) Banquet Hall 30% 120 26 m
basements etc. are given in the
Development Code chapter.
2
2 a) Community [30% 120] 26 m Parking standard @ 2 ECS / 100 sq
Recreational Club m of floor area
b) Recreational Club
3 Socio-cultural activities 35% 120 26 m 1. Parking standard @ 2 ECS / 100
such as auditorium, sq m of floor area.
music, dance & drama 2. A proper scheme for visitors
centre/ meditation & parking and parking adequacy
spiritual centre etc. statement shall be prepared
taking into consideration large
number of visitors.

1
Added vide S.O. 2790(E) dated 24-08-2016
2
Modified vide S.O. 2895(E) dated 23-09-2013

13.0 Social Infrastructure 13 19


MPD-2021 modified upto 31/03/2017

4 Exhibition cum-Fair 20% 20 -- Subject to statutory clearances


Ground
5 Science Centre 30% 120 26 m Parking standard @ 2 ECS

1
6 International [40%] 120 NR, subject to i. Parking standard @ 2 ECS/
Convention centre approval of AAI, 100sqm of floor area.
Fire Department 1
[ii. Exhibition space, Convention
and other
and meeting space shall be
statutory bodies
minimum 40% of floor area. Retail
trade, office space/ commercial
office, Hotels and related activities
shall be upto maximum 60% of floor
area.]

2 NR, subject to 1. Parking standard @ 2 ECS / 100


[7 Socio-Cultural Centre 40% 120
approval of AAI, sq m of floor area.
Fire Department 2. Socio Cultural activities shall be
and other minimum 40% of floor area.
statutory bodies. Retail trade, office space/
commercial office, Hotels and
related activities shall be upto
maximum 60% of floor area.]
Notes:
i) The Recreational Clubs located in LBZ Area, Civil Lines Bungalow Area, Recreational Use Zones and
existing on Heritage Structures will be dealt on case to case basis and Technical Committee of DDA
will approve the Development Controls norms based on the existing status.]
ii) In the open area apart from outdoor games / sport facilities, swimming pool would be permissible upto
a area of 300 sqm. free from ground coverage.
iii) In case of Banquet Hall,
a) Basements within the ground envelope shall be allowed for parking. Stilt floor for parking is
permissible.
b) 30% of basement area for services / storage shall not be counted in FAR.
3
[v) In case of International Convention Centre, maximum 10% ground coverage shall be allowed for
providing atrium. In case, the permissible additional ground coverage for atrium is utilized, 25% of the
utilized ground coverage shall be counted towards FAR.]

13.9 OTHER COMMUNITY FACILITIES


The Planning Norms, Standards and Development Controls for other facilities such as old
age homes, religious facilities, etc. are as given in Table 13.18.

1
Added vide S.O. 1901(E) dated 26-05-2016
2
Added vide S.O. 2790(E) dated 24-08-2016
3
Added vide S.O. 2890(E) dated 23-09-2013
13.0 Social Infrastructure 13 20

You might also like