3a. On the inputs summary tab choose which unit you would like to use, IP or SI, the following sheets will change a
3b. Building charactertistics on the Inputs summary, Envelope and Internal Gains, and HVAC tabs (fill out the highl
4. Energy, demand, water and other data on the Energy and Water Data tab
5. Describe the energy efficiency measures and their energy and cost savings on the Energy Eff Measures tab
NOTE1: Teams should provide as much information as possible. We understand that all data may not be available in all so
NOTE2: The highlighted blue cells will turn white when they have been filled in
wn 2018
llowing sheets will change according to what you have choosen here
Coach
Captain
Architect
Engineer
Roles
Designer
Energy Modeler
Fan
Software Used by Team
Simulation Engine (eg. EnergyPlus, DOE-
Software Name
2, Apache, Trace, etc.)
List the software the team used to simulate their building such as energy, lighting, airflow, or other.
Version/Date
Summary of HVAC
Zone Conditioning
Air Handling Units
Other
Plant Information
Chiller COP 0 Heating Fuel Type
Chiller Capacity 0.0 kW Heating efficiency
Notes
*note, once choosen all tabs will be filled in in these units, can not mix and m
CHOOSE UNITS HERE (SI/IP) IP
* Fill in blue shaded boxes, other have conversions / formula inclu
Museum
10 W/ft²
10 ft²/Person
20 W/ft²
0
0%
units, can not mix and match units
Constructions
Roof
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
R- 0
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
R- 0
Walls, Above Grade
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
R- 0
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
R- 0
Floor / Ceiling
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
R- 0
Slab on Grade Floors
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
R- 0
Fenestration
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
SHGC 0
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
SHGC 0
Skylight
Detailed architectural description
U-Value = Btu/hr/ft²/F 0.000 W/m².K
SHGC 0
Automatic shading devices?
Automatic exterior shades?
* Fill in blue shaded boxes, other have conversions / formula included
TOTAL 100
NOTE: the tables below convert units automatically for comparision amongst teams. No need to fill these in
Heating [°C] Cooling [°C]
Thermostat Controls Area m²
Setpoint Setback Setpoint Setback
Zone Type eg Office 9 -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
0 - -17.8 °C -17.8 °C -17.8 °C -17.8 °C
TOTAL 9
Lighting Levels Schedules Lighting Occupancy Schedules
Internal Gains
W/ft² Total (W) ft²/Person TOTAL Occupancy
Zone Type eg Office 10 1,000 10 10
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
0 - -
Average 10 W/ft² 10 ft²/Person
Equipment Schedules
W/m² TOTAL Equipment
215.28 2,000 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
0.00 - 0
215.3 W/ft²
HVAC Details * Fill in blue shaded boxes, other have conversions / formula included
System Type
HVAC Sizing
Air Conditioning
Heating
HVAC details
Add description of AHU here, ie VAV reheat etc…
Supply Fan Type
Pressure drop [psi]
Efficency [%]
Return Fan Type
Pressure drop [psi]
Efficency [%]
Heating Coil Type
Efficiency [%/EER]
Leaving Air Temperature [°F]
Cooling Coil Type
Efficiency [%/EER]
Leaving Air Temperature [°F]
Total Outdoor Air [cfm]
Total Supply Air [cfm]
AHU supply air temperature [°F]
Demand Control Ventilation?
Air Side Economizer?
Heat Exchanger? If yes
efficency?
Zone conditioning unit details (ie
fan coil, Chilled beams etc..)
Heating
Cooling
Interior Lighting
Exterior Lighting
Interior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Generators
TOTALS 0 0 0
ft2
Heating
Cooling
Interior Lighting
Exterior Lighting
Interior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Generators
0 TOTALS #DIV/0! #DIV/0! #DIV/0!
Heating
Cooling
Interior Lighting
Exterior Lighting
Interior Equipment
Fans
Pumps
Heat Rejection
Humidification
Heat Recovery
Water Systems
Generators
#DIV/0! TOTALS #DIV/0! #DIV/0! #DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
#DIV/0!
teams, there is no need to fill these out.
ft2
Water
[Liter/m2]
#DIV/0!
#DIV/0!
Energy Efficiency and Renewables M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Energy Efficiency and Renewables Meas
Cumulative (Total)
es Measures * Fill in blue shaded boxes, other have conversions / formula included
Change in
Annual Energy Cost Estimated Incremental Change in Simple
Annual Energy
Savings Cost EUI Payback
Use
kBtu $ $ $/ft2 kBtu/ft2 Months
Years
0 $ - $ - 0.00 0.00 0.0
rsions / formula included
NOTE: These tables are conversions and used for comparison between teams, there is no need to fill th
Floor area 0 m2
Change in
Annual Energy Change in
Annual Energy Estimated Incremental Cost
Cost Savings EUI
Use
kWh $ $ $/m2 kWh/m2
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
- $0 $0
0 $ - $ - 0.00 0.00
ween teams, there is no need to fill these out.
Simple
Payback
Months
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Years
0.0