You are on page 1of 4

■ MEMBER NAME : 3F B3 [ Section : BOTH END ]

1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm

2. Material
(1) : 21.00MPa
(2) : 275MPa
(3) : 227MPa

3. Section
(1) Section Size : 300 x 350mm ( R-Section )
(2) Cover : 40.00mm
(3) Compression : Not Considered
(4) Splicing Limit : 50%

300
40

350
40

4. Moments and Forces


(1) : 0.000kN·m
(2) : 0.000kN·m
(3) : 51.13kN

5. Reinforcement
(1) Top Bar = 603mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(2) Bot Bar = 603mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(3) Stirrup = 157mm² )
6. Check Bending Moment Capacity ( Positive )
(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ Moment is zero. Skipped.
(3) Calculate required ratio of reinforcement
ㆍ Moment is zero. Skipped.
(4) Calculate moment capacity
ㆍ Moment is zero. Skipped.

7. Check Bending Moment Capacity ( Negative )


(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ Moment is zero. Skipped.
(3) Calculate required ratio of reinforcement
ㆍ Moment is zero. Skipped.
(4) Calculate moment capacity
ㆍ Moment is zero. Skipped.

8. Check Shear Capacity


(1) Calculate shear strength by concrete
ㆍ ø = 0.750 d = 292mm
ㆍ = = 51.18kN

(2) Calculate required shear strength by shear reinforcement
ㆍ = =
ㆍ = = 0.463mm²/mm
ㆍ = = 0.463mm²/mm
(3) Calculate shear strength by stirrup
ㆍ =2 = 78.50mm² ( d10 )
ㆍ = = 156kN
(4) Calculate ratio of shear capacity
ㆍ = = 207kN
ㆍ = 0.247 → O.K
(5) Calculate spacing limits for reinforcement
ㆍ = min [ d/2, 600mm ] = 146mm
ㆍ = = 339mm
ㆍ = = 146mm
ㆍ s = = 146mm → O.K

■ MEMBER NAME : 3F B3 [ Section : MIDDLE ]

1. General Information
(1) Design Code : ACI318M-14
(2) Unit System : N, mm

2. Material
(1) : 21.00MPa
(2) : 275MPa
(3) : 227MPa
3. Section
(1) Section Size : 300 x 350mm ( R-Section )
(2) Cover : 40.00mm
(3) Compression : Not Considered
(4) Splicing Limit : 50%

300
40

350
40

4. Moments and Forces


(1) : 0.000kN·m
(2) : 45.75kN·m
(3) : 0.000kN

5. Reinforcement
(1) Top Bar = 603mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(2) Bot Bar = 1,006mm² )
ㆍ Layer 1 = 58.00mm )
ㆍ Layer 2 = 99.00mm )
(3) Stirrup = 157mm² )
6. Check Bending Moment Capacity ( Positive )
(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ = =
ㆍ = = 455mm, =2
ㆍ s = 46.00 < 455mm → O.K
(3) Calculate required ratio of reinforcement
ㆍ = =
ㆍ = = 0.0051
ㆍ = = 0.0102
ㆍ = = 0.0051
ㆍ = = 0.0236
ㆍ = = 0.0236
(4) Check ratio of tensile reinforcement
ㆍ ρ = = 0.0115

(5) Calculate moment capacity
ㆍ a = = 51.64mm
ㆍ ø = 0.900
ㆍ = = 73.60kN·m
ㆍ = 66.24kN·m
(6) Calculate ratio of moment capacity
ㆍ = 0.691 → O.K

7. Check Bending Moment Capacity ( Negative )


(1) Calculate design parameter
ㆍ = 0.850
(2) Check space of rebar
ㆍ Moment is zero. Skipped.
(3) Calculate required ratio of reinforcement
ㆍ Moment is zero. Skipped.
(4) Calculate moment capacity
ㆍ Moment is zero. Skipped.

8. Check Shear Capacity


(1) Calculate shear strength by concrete
ㆍ ø = 0.750 d = 292mm
ㆍ = = 51.18kN

(2) Calculate shear strength by stirrup
ㆍ =2 = 78.50mm² ( d10 )
ㆍ = = 78.05kN
(3) Calculate ratio of shear capacity
ㆍ = = 129kN
ㆍ = 0.000 → O.K
(4) Calculate spacing limits for reinforcement
ㆍ = min [ d/2, 600mm ] = 146mm
ㆍ = = 146mm
ㆍ = = 146mm
ㆍ s = = 146mm → O.K