Professional Documents
Culture Documents
Bolt Information
Concrete Ultimate Strength fc = 25 N/mm²
Type of bolt analysis = Elastic
Anchor Bolt Material Grade = A193-B7
Bolt Tensile Strength (Fu) = 689 N/mm²
Bolt Yield Strength (Fy) = 517 N/mm²
Number of bolts (N) = 20
Bolt Diameter (db) = 30 mm
Bolt Net Area (Ar) = 529.875 mm2
A/F Pole diameter (Dp) = 1200 mm
Pitch diameter of thread bolts (Dcc) = 1310 mm
Outside diameter of Flange (Df) = 1400 mm
COMPANY Project CLIENT
30m monopole for SAHARA STAR
Spectrophotometry
REV D Designed BY SYED Checked BY SALEH
Reinforcement bars development length Idr = 1.3 SR Fy(Ψt Ψe Ψs) /[1.1 λ Sqrt(Fc) ((cb +Ktr)/db)] db
Idr = 1162.91 mm
> 300mm hence OK
Length Of anchor Bolt above Concrete Lup = 200.00 mm
Minimum Length of Anchor bolt = 1362.91 mm
Use Ancor bolt Length = 1400.00 mm
COMPANY Project CLIENT
30m monopole for SAHARA STAR
Spectrophotometry
REV D Designed BY SYED Checked BY SALEH
= 2.00
No. Of welds
Section of modulus for polygonal for shaft at = 0.411*D^3*t/(D/2)
bottom (Zw)
= 5918400 mm3
Maximum stress due to bending moment on weld
= 178.09 N/mm2
connection
Since we have two weld line so each weld shall Section of modulus for polygonal for
carry at least half the stress. shaft at bottom (Zw)+I177:I183
=
Maximum Weld stress of the single welds 89.04 N/mm2
calculating weld strength
from weld data sheet : (Flux Core 71T )with = 400 N/mm2
(Rm)min
For 5mm Weld Size : Weld Strength = weld size X 0.707 X 400
Weld Stress Capacity of one line = 1414 N/mm2
Weld stress capacity >>>> Bending stress on base plate connection….Safe
Check Concrete Bearing Capacity
Maximum Pressure on concrete base = (Cu /Ap) + ( Mc /Zp)
Modulus of section for base plate (Pi* ODB^3/32) = 269255000 mm3