B-65165E/02 START-UP PROCEDURE 3.

START-UP PROCEDURE

3.3 SETTING THE PRINTED-CIRCUIT BOARD

Before supplying power, set the printed-circuit board as listed below.

3.3.1 Power Supply Module

Checking the DIP switch setting


(1) CE-marked products
Model DIP switch Position Description
PSM-5.5 to 11 S1 SHORT Do not change the setting of the
S2 OPEN(*1) DIP switches because they were
PSM-15 to 55 S1 SHORT already set at the factory.
S2 OPEN
PSM-18HV to S1 SHORT
75HV S2 OPEN

*1 This setting has been made in shipments after January, 2000. In


earlier products, this switch was factory-set to SHORT.

(2) Non-CE-marked products


Model DIP switch Position Description
PSM-5.5 to 11 S1 SHORT Do not change the setting of the
S2 OPEN DIP switches because they were
PSM-15 to 30 S1 SHORT already set at the factory.
S2 OPEN

- 27 -
3. START-UP PROCEDURE START-UP PROCEDURE B-65165E/02

3.3.2 Servo Amplifier Module


(1) Checking the jumper plug setting (for SVM1 and SVM2)
Set the servo amplifier module to either interface type A or B with
the jumper plugs.

FANUC

S1

S2

FUSE Move the jumper plugs as required. If


you cannot pull out a jumper plug with
your thumb and finger, use long-nose
pliers or the like.

Jumper plug
Description
S1 S2
SHORT OPEN With this setting, the servo amplifier module can operate
with the CNC (such as FS0, FS15, FS16, FS18, or PM-
D) designed for operation with interface type A. In this
case the JV*B connector is used.
OPEN SHORT With this setting, the servo amplifier module can operate
with the CNC (such as FS20 or FS21-G) designed for
operation with interface type B. In this case the JS*B
and JF* connectors are used.

NOTE
There is no jumper plug or DIP switch on the three-
axis servo amplifier module. The specification of the
servo amplifier module determines the type (A or B)
of the interface with which it can operate.

(2) Mounting the batteries for the ABS pulse coder

See Sec. I.5.1.

- 28 -
B-65165E/02 START-UP PROCEDURE 3. START-UP PROCEDURE

3.3.3 Spindle Amplifier Module

3.3.3.1 series spindle amplifier module (SPM)

This type of modules do not have a DIP switch except the modules of
which specification drawing numbers are A06B-6072-H***#00xx (D
series spindle amplifier modules) and A06B-6078-H***#H5xx (non-
CE-marked α series spindle amplifier modules).

Location of the DIP switch

DIP switch
S7
SW

S1

F2
5A

Switch setting
DIP
(factory-set to the Description
switch
underlined position)
S1 ON If two SPMs are connected to one serial interface
OFF cable, S1 is set to ON in one SPM, and to OFF in
the other.
S2 ON If an analog filter is used at the load meter output,
OFF S2 is set to ON. If not, it is set to OFF.
S3 ON If an analog filter is used at the speedometer
OFF output, S3 is set to ON. If not, it is set to OFF.
S4 S4:ON, S5:OFF Reference switch of Reference switch
S5 NPN type (pull up) (external reference signal
S4:OFF, S5:OFF Reference switch of receive function) setting
PNP type (pull down) for the main spindle
S4:OFF, S5:OFF The external reference
signal receive function.
S6 S6:ON, S7:OFF Reference switch of Reference switch
S7 NPN type (pull up) (external reference signal
S6:OFF, S7:OFF Reference switch of receive function) setting
PNP type (pull down) for the sub-spindle
S6:OFF, S7:OFF The external reference
signal receive function
is not used.

- 29 -