You are on page 1of 16

Project:

Location:
Consultant:

BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount

I MECHANICAL WORKS
Supply and fixing, testing and commissioning of Manual Coarse Bar
1
Screen 1.00 No. 50,000 50,000
Size: To Suit 400mm Wide x 200mm Liquid Height
Clear Opening of Screen: 25mm
Size of Flat: 50mm x 6mm
Angle of Inclination: 60 Degree
Shape of Screen: Curved Top
Accessories: Rake & 2 Nos. Side Plate
MOC: SS 304
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Manual Fine Bar


2
Screen 1.00 No. 50,000 50,000
Size: To Suit 300mm Wide x 200mm Liquid Height
Clear Opening of Screen: 10mm
Size of Flat: 50mm x 6mm
Angle of Inclination: 45 Degree
Shape of Screen: Curved Top
Accessories: Rake
MOC: SS 304
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Slotted Pipe Oil


3
Skimmer 1.00 No. 100,000 100,000
Size: To Suit 750mm Wide Oil & Grease Trap
Size of Slotted Pipe: 200mm Dia
Type of Operation: Manual Hand Wheel
MOC of All Wetted Parts : SS 304
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

4 Supply and fixing, testing and commissioning of Equ Tank Blower


2.00 Nos. 100,000 200,000
Capacity of Blower: 50m3/Hr @ 5.5 MWC
Type of Blower: Twin Lobe
MOC of Blower: CI
Speed of Blower : Less than 1000 RPM
Speed of Blower Motor: 1440 RPM
The Blower shall be complete with Blower & Motor mounted on a
common base frame, belt drive, belt guard, Suction & Discharge Silencer,
Air Filter, Safety Valve, NRV, etc., complete.
Make: Kay/Everest/Swan
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

654309868.xls 1 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
PH METER :- supply and Fixing of PH meter PO 650 ph/orp with
push button type for physical dimensions 105x105x130mm cut out
size 92x92mm enclosure ABS weather proof IP-65 calibration /set
point ,Sensor dimension 140mmx32mm ,Flow throw . It includeing cost
5 and conveyance , all taxes specification Provided at the outlet of
Sewerage treated water sump it including all taxes as directed by
Engineer-in-charge .
1.00 No. 45,000 45,000

Supply and fixing, testing and commissioning of Coarse Bubble


6
Diffusers 10.00 Nos. 1,000 10,000
Type: Disc Diffuser
Size: 90mm Dia
MOC: EPDM
Make: Rehau/OTT/SSI/Aquaflex/Techpro
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Equ Effluent/Sewage


7
Pump 2.00 Nos. 100,000 200,000
Capacity of Pump: 15 Cu.m/Hr @ 6m Head
Type of Pump: Non Clog Vertical Submersible
Solid Handling Size: 80mm
Impeller Type: Non Clog
MOC of Casing: CI
MOC of Impeller: CI
Accessoreis: Auto Coupling, SS304 Lifting Chain, SS Guide Pipe, Control
Panel with Level Switches for auto Start & Stop
Make: Kishor/KSB/Grundfos/CRI/Wilo
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

8 Supply and fixing, testing and commissioning of Mixer for Anoxic Tank
1.00 Nos. 100,000 100,000
Type: Turbine Type
RPM of Mixer: 100
MOC of Shaft & Blades: SS 304
Motor KW: 1.1
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

9 Supply and fixing, testing and commissioning of Aeration Blower 2.00 Nos. 180,000 360,000
Capacity of Blower: 120Nm3/Hr @ 5.5 MWC
Type of Blower: Twin Lobe
MOC of Blower: CI
Speed of Blower : Less than 1000 RPM
Speed of Blower Motor: 1440 RPM
The Blower shall be complete with Blower & Motor mounted on a
common base frame, belt drive, belt guard, Suction & Discharge Silencer,
Air Filter, Safety Valve, NRV, etc., complete.
Make: Kay/Everest/Swan
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

654309868.xls 2 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount

10 Supply and fixing, testing and commissioning of Fine Bubble Diffusers


20.00 Nos. 1000.00 20000.00
Type: Tubular
Size: 1.0m Long x 90 Dia
MOC: EPDM
Make: Rehau/OTT/SSI/Aquaflex/Techpro
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Air Piping from Blower
11
upto Diffusers for Equ Tank Blower & Aeration Blower 100.00 KGS 400.00 40,000
MOC of Exposed Pipes: SS 304
MOC of Vertical Drops: SS 304
MOC of Under Water pipes: SS 304
MOC of Guide Pipe & Lifting Chain: SS 304

The Air Piping shall be complete with Individual blower delivery piping
with NRV, Diaphragm Valve, Main Header Piping from the Blower
delivery up to equ tank/aeration tank including drop/vertical piping,
header along the tank, vertical drop pipes with control valve & dismantling
type joint, diffuser header pipe & laterals with nozzles for diffuser, end
cap, vertical guide pipe at the other end of diffuser header, lifting chain,
etc., complete. The design of piping shall be such that it should be
possible to remove diffusers from the tanks without emptying tank &
shutting off the system. The arrangement shall be that the we should be
able to take out the Vertical drop pipe & the diffuser header just by
dismantling the joint in the vertical drop pipe and should be able to refix
the same in position.

Pipe Sizes: As per Diffuser Manufacturer recommendations.


The Contractor has to provide detailed air piping calc for the air pipes
from the diffuser supplier to match the specified blower.
Battery Limit: Form Flange of Blowers till diffuser
The Piping cost is inclusive all necessary materials required for the piping
like pipes, fittings, adopters, flanges, fasteners, pipe supports, clamps,
valves, labour charges for fabrication, erection, pressure testing, etc.,
complete.
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

12 Supply and fixing, testing and commissioning of Media for MBBR Tank
45.00 Cu.m 16,000 720,000
Volume of Media: 45 Cu.m
Shape of Media: Conical Frustum
Surface Area: 400 m2/m3 of media
Structure: Cylindrical with Fins
Sp Gravity: 0.9 to 0.95
MOC: Virgin P P UV Stabilised
Make: MM Aqua/ Tecpro/Enery Equipment
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

654309868.xls 3 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount

Supply and fixing, testing and commissioning of Internal Recirculation


13
Pump 2.00 Nos. 85,000 170,000
Capacity of Pump: 15 Cu.m/Hr @ 3m Head
Type of Pump: Non Clog Vertical Submersible
Solid Handling Size: 80mm
Impeller Type: Non Clog
MOC of Casing: CI
MOC of Impeller: CI
Accessoreis: Auto Coupling, SS304 Lifting Chain, SS Guide Pipe, Control
Panel with Level Switches for auto Start & Stop
Make: Kishor/KSB/Grundfos/CRI/Wilo
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.
Final payment after Lab Testing treated water satisfing the following
parameters BOD less than 5, COD less than 10

Supply and fixing, testing and commissioning of Media for TUBE DECK
14
Media 5.00 Cu.m 8,000 40,000
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

15 Supply and fixing, testing and commissioning of Sludge Pump 2.00 Nos. 85,000 170,000
Capacity of Pump: 25 Cu.m/Hr @ 3m Head
Type of Pump: Horizontal Centrifugal
Impeller Type: Non Clog
MOC of Casing: CI
MOC of Impeller: CI
Make: Johnson/Kirloskar/KSB
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

16 Supply and fixing, testing and commissioning of UV Disinfection System


1.00 No. 200,000 200,000
Flow: 25 Cu.m/Hr.
Type of Flow: Gravity
Type: UV Lamp covered with Quartz Glass
MOC of Enclosure: SS 304
Accessories: Control Panel
Make: Hitech/Sukrut/Equ.
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

17 Supply and fixing, testing and commissioning of Filter Feed Pump 2.00 Nos. 90,000 180,000
Capacity of Pump: 25 Cu.m/Hr @ 30m Head
Type of Pump: Horizontal Centrifugal
Impeller Type: Semi Open
MOC of Casing: CI
MOC of Impeller: CI
Make: Johnson/Kirloskar/KSB
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

18 Supply and fixing, testing and commissioning of Pressure Sand Filter


1.00 No. 120,000 120,000
Capacity of Filter: 7.50 Cu.m/Hr.
Minimum Dia of Filter: 0.90m

654309868.xls 4 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
Minimum HOS of Filter: 1.8m
Minimum Height of Filter Sand: 0.30m
Minimum Plate Thickness for Shell & Dish: 6mm
Type of Underdrain: Nozzle Plate with Plastic Nozzles
Type of Inlet: Inlet Distribution Box/ Bell Mouth.
Specification for Filter Media: As per CPHEEO Manual
MOC of Filter: MSEP
Accessories: Frontal Piping & Valves.
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

19 Supply and fixing, testing and commissioning of Activated Carbon Filter


1.00 No. 200,000 200,000
Capacity of Filter: 7.50 Cu.m/Hr.
Minimum Dia of Filter: 0.70m
Minimum HOS of Filter: 1.8m
Minimum Height of Activated Carbon: 0.30m
Minimum Plate Thickness for Shell & Dish: 6mm
Type of Underdrain: Nozzle Plate with Plastic Nozzles
Type of Inlet: Inlet Distribution Box.
Type of Activated Carbon: Coal Based/Coconut shell
Minimum Iodine Value for Activated Carbon: 1000
MOC of Filter: MSEP
Accessories: Frontal Piping & Valves.
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Hypochlorite solution


20 dosing System 1.00 System 65,000 65,000
Dosing System shall be complete with
1 No. - 100 Lit Capacity HDPE Tank with Inlet & Outlet Connections,
Level Indicator
Dosing Pump, 0 - 5 LPH Capacity, 2 Nos.
Complete Flexible Tubing with Valves, NRV's, Strainers, etc., from
Dosing Tank to dosing Point
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of FeCl3 solution dosing


21 System 1.00 System 35,000 35,000
Dosing System shall be complete with
1 No. - 50 Lit Capacity HDPE Tank with Inlet & Outlet Connections, Level
Indicator
1 No. - Agitator to suit 50 Lit HDPE tank of SS 304 MOC, 100 RPM
speed.
Dosing Pump, 0 - 6 LPH Capacity, 2 Nos.
Complete Flexible Tubing with Valves, NRV's, Strainers, etc., from
Dosing Tank to dosing Point
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

22 Supply and fixing, testing and commissioning of Treated Water Pump


2.00 Nos. 85,000 170,000
Capacity of Pump: 15 Cu.m/Hr @ 20m Head
Type of Pump: Horizontal Centrifugal
Impeller Type: Semi Open
MOC of Casing: CI
MOC of Impeller: CI
Make: Johnson/Kirloskar/KSB

654309868.xls 5 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

654309868.xls 6 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount

23 Supply and fixing, testing and commissioning of Filter Press Feed Pump
2.00 Nos. 100,000 200,000
Capacity of Pump: 1 Cu.m/Hr @ 20m Head
Type of Pump: Screw Pump
Impeller Type: Screw
MOC of Casing: CI
MOC of stator : Nitrile
MOC of rotor : SS 304
Make: PD pumps / Rotomac / Alpha helical /Roto
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Manual Plate Filter


24 Press 1.00 No. 125,000 125,000
Size of Plate: 610 x 610mm
No. of Chambers: 8 Chamber
Operation: Hydraulic Pump
Capacity: For Dewatering of 2 Cu.m/Day, 3% Sludge in 10Hour
Make: Hydro Press/Yo-Tana/Amar/Equ.
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Dewatering PE solution


25 dosing System 1.00 System 65,000 65,000
Dosing System shall be complete with
2 Nos. - 50 Lit Capacity HDPE Tank with Inlet & Outlet Connections,
Level Indicator
2 Nos. - Agitator to suit 100 Lit HDPE tank of SS 304 MOC, 100 RPM
speed.
Dosing Pump, 0 - 60 LPH Capacity, 2 Nos.
Complete Flexible Tubing with Valves, NRV's, Strainers, etc., from
Dosing Tank to dosing Point
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Supply and fixing, testing and commissioning of Jib Crane for Lifting of
26 Submersible Pumps 1.00 No. 120,000 120,000
Capacity : 0.5 Ton
Min Clear Height: 2.50m to the Bottom of the Hook (From Base plate).
Degree of Rotation: 360 Degrees.
Length of Boom: 2.0m to the Centre of Lifting Hook from the centre of
mast.
Rotating Operation: Manual
Accessories Reqd: 0.5 Ton Capacity Chain Pulley Block with Lifting
Chain of 9.0m + Trolley of reputed make.
Mast section: Circular Mast of required Height
Method of Installation: By Welding to Fish Plate embedded in concrete.
Make: Reputed
including all incidental and operational charges etc, as per approved
drawings and as directed by Engineer-in-charge complete for finished
item of work.

Sub - Total 3,755,000

MAIN PANEL IN ELECTRICAL ROOM

654309868.xls 7 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
1 Supply, installation, testing and commissioning of wall/floor mounting type
panel board with alluminium bus bars fabricated with 16 Gauge CRCA
Sheet comprising of TPN bus bars of equal size in all phases and neutral
equipped with bus bar chambers and cable chambers.The bus bars fault
level shall be 50 KA and shall be as per the requirement of local CEIG,
fire regulations, CPRI norms and other authorities etc. The painting of the
complete system shall be powder coated duly processing the panel in 7
tank process. The panel shall be suitable for accomdating the following
switch gear including supply of all components, hard wares etc including
all necessary civil works, adequate reinforcement, foundation bolts,
suitable G.I earth strip 50 x 6mm, door loop earthings, bus bars should be
colour sleeved with heat shrinkable sleeves for phase and neutral duly
supported at regular intervels by

1 NOS 200000.00 200,000


SMC supports and all cables shall have proper cable entry, danger
board, feeder identification marks, rigid inter connections, cadmium
plated bolts and nuts and shall be installed on wall/flooring and consisting
of the following as required and as per IS standards for [MAIN PANEL
IN ELECTRICAL ROOM
Panel shall be manufacture only from CPRI approval Fabricators.

400A Aluminium Bus Bar with colour code.(0.8A/Sqmm).


Internal wiring with approved make cable

Earthing Flat: Providing suitable G.I Flat


Incommer: 400A, 4 Pole, MCCB, 36/35 KA - 1 No.
Makes:
Incommer:L&T400A,
/ Schneider / Siemens
4 Pole Change Over/ Hager
Switch on Load
with open Execution.
Metering Set:
Makes: Socomec / L & T / HPL / Havells - 1 No.
0- 250A Digital Ammeter with selector switch . - 1 No.
Makes: CONZERVE / ELMEASURE / LEGRAND / MECO / HPL
0-500V Digital Volt meter with selector switch - 1 No.
Makes: CONZERVE / ELMEASURE / LEGRAND / MECO / HPL
R, Y, B Indication lamps of LED type - 3 Nos.
Makes: L&T / C&S / SALZAR / HPL .
250/5A C.T coils - 3 Nos. Makes: KAPPA
20A Bakelite Fuse Fittings - 3 Nos.
2A HRC Fuse link - 3 Nos.
Outgoing:-
125A, 3 Pole, MCCB, 25 KA - 3 Nos
Make : L&T / Schneider / Siemens / Legrand / Hager
63A, 3 Pole, MCCB, 25 KA - 24 Nos
Make : L&T / Schneider / Siemens / Legrand / Hager
Labour charges etc complete with connections for Finished item of work.

APFC PANELS-100 KVAR


2 Supply, installation, testing and commissioning of TPN 415V, free
standing type cubical panel board made out of 16 Gauge CRCA sheet
steel, the panel shall be painted after processing 7 tank process with RAL
7032 siemens grey. The panel shall be consisting of suitable rating of
allumunium bus bars (At the rating of 0.8 A/Sq.mm) supported with
DMC/SMC and colour coded with heat shrinkable sleeves. The bus bars
fault level shall be 50 KA and shall be as per the requirement of local
CEIG, fire regulations, other authorities etc. The panel shall be suitable
for accomdating the following switch gears including supply of all
components, hard wares etc including all necessary civil works, adequate
reinforcement foundation bolts suitable G.I earth strip , 100 x 50mm MS
base channel, earth bar, door loop earthings, Bus bar to switch
interconne-ctions. All cables shall have proper cable

1 No 100000.00 100,000
entry gland plates, suitable size of glands, earth tags for glands, lugs,
cadmium plated nuts , bolts, feeder identification marks,and shall be
installed on performed trench and consisting of the following as required
and as per IS standards.

654309868.xls 8 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
400 A Aluminium Bus Bar with colour code.
Internal wiring with approved make cable
Earthing Flat: Providing suitable G.I Flat
Incommer: .
250A Four Pole, MCCB of 35/36 KA of make L&T d sine Model/
Siemens / Schneider - 1 No
Metering Set:
0-250A Digital Ammeters -1No of makes: CONZERVE / ELMEASURE /
LEGRAND / MECO / HPL.
0-500A Digital Voltmeters -1No of makes: CONZERVE / ELMEASURE /
LEGRAND / MECO / HPL.
R,Y,B indication Lamps LED type - 3 Nos of makes LED type L&T / C&S /
SALZAR / HPL

Indication Lamps LED type for Capacitor ON & OFF of makes LED type
L&T / C&S / SALZAR / HPL
Auto/Manual selector switches for capacitors/Ammeter/ Voltmeter.
Makes: L&T / C&S / SALZAR / HPL - 8 No
6-32A SP MCBs of Legrand/Schneider make - 6 No
250A/5A CTs -3 Nos of kappa make or desired by field authority.
APFC relay 8 stage with suitable CTs sensing from main bus bar of main
panel. (makes: L&T / Siemens / EPCOS / Schneider)
Outgoing:
63 A TP, MCCB , 35/36 KA of make L&T d sine Model/ Siemens /
Schneider - 5 No
20 KVAR heavy duty capacitors of MPP - 5 Nos of
L&T/Siemens/Schneider/EPCOS make
Capacitor duty contactors of L&T Make for 20 KVAR Capacitor, model
No: MO C20 for 20 KVAR heavy duty capacitors - 5 No
Each Capacitor Bank shall have the following:
ON /OFF Indication Lamps, Ammeter with resign cast CTs and Selector
switch, Auto/Manual selector switch with 1 set of ON/OFF push buttons
for manual operation.
Note: All Capacitors shall be Delta connected and rated for 440V and of
MPP type. The capacitors shall be provided in the panel it self with proper
vertilation arrangements. All contactors in this panel shall be capacitor
switching contactors only.
Labour charges etc complete with connections for finished item of work
including all accessories, Auto / Manual Selector switches, auxilary
contactors for auto manual operation, CTs and push buttons, indication
lamps for on and off indication with all accessories etc. compele for
finished item of work.

3 Supply & Fixing of D.O.L Starter 415V, 3 phase, 50Hz..


enclosed with no volt coil, overload protection and single
phase preventor , etc., complete suitable for 10.0.HP.
Makes: Siemens / Crompton / L&T (MU1 DOL)
( SSR - 17-18 -5.4.3 ) 10 No 3144.00 31,440

U.G CABLES

4 Supply of the Following PVC XLPE armoured cable 1100 V Grade with
ISI mark stranded / solid, aluminimum conductor complete. as per
specification confirming to IS:7098 (Part - I).
Make: RPG/ POLY CAB/ Havells/Finolex/ Paragan / Unicab/ V-Guard/
fortune Art EBXL.
a 3.5 Core 95.00 Sq.mm. 100 RM 434.00 43,400
b 3.5 Core 70.00 Sq.mm. 50 RM 333.00 16,650
c 3.5 Core 50 Sq.mm. 35 RM 258.00 9,030
d 3.5 Core 35 Sq.mm. 35 RM 195.00 6,825
e 3.5 Core 25 Sq.mm. 45 RM 166.00 7,470
f 4.0 Core 16 Sq.mm. 75 RM 129.00 9,675
g 4.0 Core 10 Sq.mm. 65 RM 118.00 7,670
h 4.0 Core 6 Sq.mm. 65 RM 103.00 6,695
i 4.0 Core 4 Sq.mm. 80 RM 103.00 8,240

654309868.xls 9 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount

5 Earth work excavation of Trench in hard ground soil, laying of U.G cables
of size up to 70 Sqmm on sand cusion covering the cable with bricks and
back filling of Trench duly providing route indicator (as per general
instruction S.No. 14 of SSR) embedded in C.C including cost and
conveyance of materials and labour charges etc., complete.
100 RM 133.00 13,300

6 Labour charges for run of U.G cable on wall / existing pipe with
necessary fixing arrangments such as saddles, clamps,wooden
separators etc., (as directed by departmental official) for the cables. 100 RM 34.00 3,400

CABLE GLANDS:
7 S&fixing of heavy duty flange type brass cable glands of following sizes
for PVC armoured cables with brass washers, earth tag etc complete
including all labolur charges.
a 70 to 150 Sq.mm 20 NO 243.00 4,860
b 25 to 50Sq.mm 40 NO 130.00 5,200
c up to 16 Sq.mm 40 NO 90.00 3,600

ALUMINIUM LUGS:
8 Supply and fixing of crimping type Aluminium lugs confirming to IS
specifications for following cables including nuts and bolts with
connections.
a 95 Sq.mm 5 NO 36.00 180
b 70Sq.mm 5 NO 31.00 155
c 50Sq.mm 6 NO 27.00 162
d 35Sq.mm 6 NO 22.00 132
e 25Sq.mm 6 NO 18.00 108
f 16 Sq.mm 6 NO 13.00 78

9 Supply and fixing of 25mm outer dia 2.20 mm thick Heavy grade with
IS:9537 part 3 FRLS regid PVC pipe (ISI MARK) concealed in Roof Slabs
with all required MS deep boxes and all accessories including and labour
charges etc., complete.
Makes:- VIP / Besto plast / GoldMedal / Million plast / GM /
Sudhakar / Polyline
50 RM 66.00 3,300

10 Supply and fixing of 25mm outer dia Medium grade (1.8 mm thick) with
IS:9537 part 3 FRLS regid P.V.C. pipe (ISI MARK) concealed in wall with
all required MS junction boxes and all accessories including masonary
work for light, Fan and separate plug point with MS Modular switch box
including all labour charges etc., complete for EPABX, LAN, and CCTV,
Bell, light, Fan points.
Makes:- VIP / Besto plast / GoldMedal / Million plast / GM /
Sudhakar / Polyline
50 RM 74.00 3,700

WIRING

654309868.xls 10 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
11 Wiring with 2 runs of 22/0.3mm ( 1.5 Sq.mm) FRLS / HFFR / ZHFR
P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible
copper cable (ISI MARK) in existing pipe with 6A Modular switch, Ceiling
rose/BH/SBH Modular switches with cover plate including all labour
charges etc., complete for Light, Fan, Exhaust Fan etc., complete. (for
Non Residential Building)
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

Makes of switches:- Legrand Arteor / Schneider Zen celo/ Crabtree


Murano/ GM-Zenova / Legrand Myrius / Cabtree Thames Platinum /
GM- Zicono/ / Million / Logus / Gold Medal Curve / GIFA / CPL/
Panasonic Vision / Salzer S 90 Series.

10 PTS 491.00 4,910

12 Wiring with three runs of 1.5 sq.mm FRLS / HFFR / ZHFR P.V.C.
insulated 1100V grade as per IS : 694 / 1990 specificationflexible copper
cable (phase, neutral, earth) in the existing conduit pipe with 6 Amps
Modular type switch, and 6 A 3/2 pin Modular type socket with cover
plate on common switch board etc., complete.
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

Makes of switches:- Legrand Arteor / Schneider Zen celo/ Crabtree


Murano/ GM-Zenova / Legrand Myrius / Cabtree Thames Platinum /
GM- Zicono/ / Million / Logus / Gold Medal Curve / GIFA / CPL/
Panasonic Vision / Salzer S 90 Series.

2 PTS 275.00 550.00

13 Supply and Fixing of 16A/6A, 2 in one socket with 16A switch control
modular type with MS flush boxes with front cover plate including all
labour charges etc., complete.
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

Makes of switches:- Legrand Arteor / Schneider Zen celo/ Crabtree


Murano/ GM-Zenova / Legrand Myrius / Cabtree Thames Platinum /
GM- Zicono/ / Million / Logus / Gold Medal Curve / GIFA / CPL/
Panasonic Vision / Salzer S 90 Series.

2 NOS 336.00 672

RUN of MAINS

14 Supply and run of 1 of 22 /0.3mm (1.5 Sq.mm) FRLS / HFFR / ZHFR


P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification flexible
copper cable in existing pipe for earth continuity including all labour
charges etc., complete.
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

50 RM 20.00 1,000

654309868.xls 11 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
15 Supply and run of 3 of 2.5 sq.mm (phase neutral and earth) FRLS / HFFR
/ ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990 specification
flexible copper cable in existing MS conduit pipe for individual ligting
circuits including labour charges etc., complete as required for switch
boards.
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

100 RM 82.00 8,200

16 Supply and 3 runs of 4.0 sq mm (phase neutral and earth) FRLS /


HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990
specification flexible copper cable in existing conduit pipe for run of
mains including labour charges etc., complete as required including
labour charges for 16A sockets.
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

100 RM 114.00 11,400

17 Supply & run of 3 of 6.0 Sqmm (84/0.3mm) (phase neutral and earth)
FRLS / HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 /
1990 specification flexible copper cable in existing MS conduit pipe for
run of mains including labour charges etc. complete for AC points &
SDB's etc as required.
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

25 RM 165.00 4,125

18 Supply and run of 5 of 6 Sq mm (phases, neutral and earth) FRLS /


HFFR / ZHFR P.V.C. insulated 1100V grade as per IS : 694 / 1990
specification flexible copper cable in existing MS conduit pipe for circuits
including labour charges etc. complete as required for run of mains from
Lighting panel board to TPN DB'S with pin type lugs and connections.
[for LDBs]
Makes of wires:- Finolex / RR kabel / Havells / APAR E-beam / KEI /
Polycab / Bonton / V-Guard / GM / Million / HPL / Goldmedal /
Finecab / Vimal / Fortune Art / Gloster / Kundan cab/Sudhakar

50 RM 275.00 13,750

DISTRIBUTION BOARDS

19 Supply and fixing of TPN 4 way distribution board IP-43 (8+12 Module)
Protection as per IS:13032 with provision to accommodate the ELCB
incomer and suitable for single pole outgoing MCB's in sheet Steel
enclosure with 32A 4 pole MCB as incomer and 12 No of 6 to 32 Amps
single pole, 10 KA breaking capacity 'c' Curve MCB outgoings including
making connections etc., complete concealing in wall. (LIGHTING DB's)
Makes : Legrand(Ekinox 3) / Schneider.

1 NOS 6774.00 6,774

EARTHINGS

20 Providing independent earthling by excavating a trench to a depth of 2.5


M in all soils, as per size specified in the Data, using 100mm dia Heavy
Gauge C.I ( Cast iron ) pipe of 2.5 Mtrs length with Heavy gauge Flange
with necessary accessories including filling with Bentonite powder and all
labour charges etc., complete. ( for Main Panels and DG sets )
3 No 4376.00 13,128

654309868.xls 12 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
21 Providing independent earthing for Important equipment with 40mm dia
'B' class 2.5m long G.I pipe and 19mm dia 'B' class G.I pipe of 0.3mtr.
long connected with reducer providing G.I funnel with mesh enclosed in
C.C.Chamber of 400m x 400m x 400mm with R.C.C. Slab cover duly
providing staggered 20mm holes filling with salt and charcoal from the
bottom of the pipe giving earth connection from electrode through G.I
strip of 40 x 6mm x 200mm length with all accessories and labour
charges complete, as per IS specifications 3043 /1987 (Part II)

3 NOS 3741.00 11,223

22 Providing independent earthing for Sophisticated Electronic equipment


with 600mm x 600mm x 3.15mm thick copper plate rigidly fixed to 40mm
dia G.I Pipe of 2.5mtr. length filling with salt and charcoal giving earth
connection from electrode G.I strip of 40 mm x 6mm x 200mm length and
hume pipe with all accessories and labour charges complete as per IS
specification 3043 / 1987 (Part II).
2 NOS 9201.00 18,402

23 Supply and run of No. 8SWG GI wire including cost of all accessories and
labour charges etc complete. 50 RM 15.00 750

24 Supply and run of 25mmX6mm GI strip including cost of all accessories


and labour charges etc complete.
50 RM 91.00 4,550

25 Supply and run of 25mmX3mm copper strip including cost of all


accessories and labour charges etc complete.
50 RM 379.00 18,950

FIXTURES

26 Supply, Fixing and Transportation of 18W/20W, 1200mm length LED


batten light with extruded alluminium housing and polycarbonate cover,
input voltage AC 220 - 260 Volts with PF>0.9, Surge protection:
2KV,THD<15%, with inbuilt driver and frosted cover CCT: 3000K -
5700K, minimum CRI>70, .etc., complete. with Fixing of 18W/20W LED
luminaire on wall / Ceiling with / TW round blocks with all accessories
including giving connections and all labour charges etc., complete.
Makes: Makes: Surya / Pharox / Halonix / HPL / Greenlights / Fortune
Art / Capart / GM / Goldmedal / Syska / Cosmo / Trinic b) LED
MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG /
EVERLIGHT/ San'an

10 NOS 959.00 9,590

27 Supply and fixing of BH/SBH in lieu of ceiling rose with 1 NO 3-5 W


bulb with connections etc., complete with labour charges
Makes: Anchor / Gold Medal Olive / Million Zoom.
5 NOS 10.00 50

STREET LIGHT

654309868.xls 13 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
28 Supply and transportation of 30 W LED Street light Luminaire made of
pressure diecast alluminium body with powder coated, having protective
toughned glass, Supply Input voltage 120 - 270 V AC, P.F > 0.90, high
power LED's having System efficacy > 95 lm/W and junction temprature <
70°C, with Ingrees protection IP65, Luminaire performance complies to IS
10322 (Part 5 / Sec-3), Driver surge protection 4KV, external Surge
protection ≥ 5KV with optics distribution , THD<10% at 110 Volts AC,
driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70, etc.,
complete a) LUMINAIRE MAKE : WIPRO / PHILIPS (GREEN LINE) /
Lighting Technologies(Adornis) / SCHREDER (BRIKA) / GE / VIN
(MATRIX) / CROMPTON (HAWK) / BAJAJ (EDGE+) / HALONIX
(LUMOS - SUPER) / HAVELLS (ENDURA CITYLINER NEO) b) LED
MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG /
LG
( SSR -17-18-3.9.22b)

5 NOS 3571.00 17,855

29 Supply and transportation of 60 W LED Street light Luminaire made of


pressure diecast alluminium body with powder coated, having protective
toughned glass, Supply Input voltage 120 - 270 V AC, P.F > 0.90, high
power LED's having System efficacy > 95 lm/W and junction temprature <
70°C, with Ingrees protection IP65, Luminaire performance complies to IS
10322 (Part 5 / Sec-3), Driver surge protection 4KV, external Surge
protection ≥ 5KV with optics distribution , THD<10% at 110 Volts AC,
driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70, etc.,
complete a) LUMINAIRE MAKE : WIPRO / PHILIPS (GREEN LINE) /
Lighting Technologies(Adornis) / SCHREDER (BRIKA) / GE / VIN
(MATRIX) / CROMPTON (HAWK) / BAJAJ (EDGE+) / HALONIX
(LUMOS - SUPER) / HAVELLS (ENDURA CITYLINER NEO) b) LED
MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG /
LG
( SSR - 17-18 - 3.9.22 d)

2 NOS 7768.00 15,536

30 fixing of LED / MV / SV/ MH luminaire on wall with 1.0Mtr of 40mm dia GI


pipe bracket and anti tilting MS Flat with 2.5 Sq.mm flexible copper wire
etc.,including all labour charges for mason work and giving connections
etc., complete.
10 NOS 549.00 5,490

Sub - Total 652,175

III PIPING:

Supplying, Laying, Testing & Commissioning of complete piping for the


0.65 MLD E&STP to match the P & ID and to match the layout, using
suitable material pipes of approved makes conforming to IS, including
pipe specials like bends of suitable degree, elbow, tee, union/flanges,
values, fasteners, Cutting the pipes to requirement, making joints with
pipe specials, earth work excavation, laying, refilling as required, or in
1
pipe supports including its foundation, pipe supports, clamping system,
etc., Conducting wet run, rectifying the leaks if any in laid pipe work, etc,
complete with valves as applicable. Battery Limits: From Head Manhole
near the STP (Approx. 15m), piping for Treated Water Pump for a length
of 100m from the STP boundary. The complete piping within the E&STP
area shall be contractor's scope.

The Scope of Piping Shall Include the following:


Piping from Last Manhole to Coarse Screen Chamber - 100 Dia PVC 10
A
KSC Pipe 10 m 650 6,500
Delivery Piping with Valves & NRV for Raw Effluent/Sewage Pump up to
B
Inlet Chamber - 80 NB - DI Pipe 20 m 750 15,000
Delivery Piping with Valves & NRV for Equ Effluent/Sewage Pump up to
C
Anoxic Tank - 80 NB - uPVC Sch 40 Pipe 12 m 750 9,000

654309868.xls 14 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
Delivery Piping with Valves & NRV for Internal Recirculation Pump up to
D
Inlet of Anoxic Tank - 80 NB - uPVC Sch 40 Pipe 15 m 750 11,250
Piping from Sec Clarifier Launder Outlet to Filter Feed Tank through UV
E
disinfection module - 80 NB uPVC Sch 40 Pipe 5 m 750 3,750
Filter Feed Pump Suction (Dual Suction, one from Filter Feed Tank &
F second from UF Feed Tank) and Delivery Piping with valves, NRV, up to
frontal piping of PSF &ACF - 80 NB uPVC Sch 40 Pipe 10 m 750 7,500
Sludge Pump Suction and Delivery Piping with valves, NRV, up to
G
Thickener/Inlet of Aeration Tank - 65 NB - uPVC Sch 40 Pipe 10 m 650 6,500
Treated Water Pump Suction and Delivery Piping with valves, NRV, up to
H
battery limit - 80 NB - uPVC Sch 40 Pipe 60 m 750 45,000

Sub - Total 104,500

IV INSTRUMENTATION
SITC of DO Meter of approved make with interconnection wiring for auto
switching on and off of Blowers, based on the DO Levels of the aeration
1 tank. 1.00 No. 50,000.00 50,000
SITC of 50 Dia Electro Magnetic Flow Meter with local & remote
indication panel with totaliser, including wiring between instrument &
2 remote indicator, power supply wiring, etc., complete. 1.00 No. 50,000.00 50,000
Supply, installation, testing and commissioning of Bourdentype, stainless
steel dial type pressure gauge withisolation valve and pipe having
calibrationof 0-16 kg/cm2.MAKES: HGURU / FIEBIG and Approved
3 makes 15.00 Nos 606.00 9,090
Supply and Installation of 600mm x 75mm x 2mm thick hot dip
GIperforated cable tray with cover along with required angle supportswith
coupler plates, Anchor bolts and nuts etc complete and the tray,should be
fitted on the wall / Ceiling etc. complete.

4 20.00 RM 1,300.00 26,000

Sub - Total 135,090

654309868.xls 15 of 16
BILL OF QUANTITIES
Sl.No. Description Quantity Unit Rate Amount
V OPERATION & MAINTENANCE
Operation and maintance for Sewerage treatment plant for 24 hours,
three shifts, Two helpers (in two shifts) + One Technision (Electrician in
one shift) including all required chemicals and spares and Motor winding
charges and any other spares and consumables required during
operation, including cost and conveyance of all materials and labour
charges, all taxes etc., complete as Directed by Engineer-in-Charge.(For
First year after trail run for Sewerage treatment plant).
1 12 Months 26,200 314,400

Operation and maintance for Sewerage treatment plant for 24 hours,


three shifts, Two helpers (in two shifts) + One Technision (Electrician in
one shift) including all required chemicals and spares and Motor winding
charges and any other spares and consumables required during
operation, including cost and conveyance of all materials and labour
charges, all taxes etc., complete as Directed by Engineer-in-Charge. (For
Second year after trail run for Sewerage treatment plant).

1 12 MONTHS 28,140 337,680

Sub - Total 652,080

GRAND TOTAL 5,298,845

654309868.xls 16 of 16

You might also like