Sl No Particulars No.

(N) Length (L) Breadth/ Depth/ Qty Remarks


Width (W) Height (H)
ABSTRUCT
Item of Description Unit Qunt. Rate Amount Remarks
Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding
shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant
special publications, submission of job mix formula after preliminary mix design after testing S.O.R.,PWD,GOVT OF
1 of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not Cum 27.89 6082 169643 WB,ITEM 6(iv), PAGE 25
be less than 300 Kg of cement.[using concrete mixture] M 25 Grade OF 315 & Rate Analysis.

Reinforcement Steel for reinforced concrete work in all sorts of structures including
distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if
S.O.R.,PWD,GOVT OF
2 necessary), cutting to requisite length, hooking and bending to correct shape, placing in Kg 3284.36 58.103 190831 WB,ITEM 40/a/I , PAGE
proper position and binding with 16 gauge black annealed wire at every intersection, 43- 44 OF 315
complete as per drawing and direction.

Hire and labour charges for shuttering with centering and necessary staging upto 4 m using
approved stout props and thick hard wood planks of approved thickness with required S.O.R.,PWD,GOVT OF
3 bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, Sqm 198.04 357 70700.4 WB,ITEM 36(c),36d(i) ,36
fixing and striking out after completion of works e,PAGE 42/43 OF 315.

Brick work with 1st class bricks in cement mortar (1:6) S.O.R.,PWD,GOVT OF
4 In superstructure Cum 47.52 4696 223164 WB,ITEM 8 b,PAGE 15
OF 315
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in S.O.R.,PWD,GOVT OF
5 Sqm 76.6251 622 47660.8 WB,ITEM 16,PAGE 16
OF 315
Supplying, fitting and fixing Fan Hook for ceiling with 1 metre long 16mm dia rod complete S.O.R.,PWD,GOVT OF
6 including mending damages. Payment for damage and repair to be made separately. Each 6.0 100 600 WB,ITEM 30 ,PAGE 40
OF 315
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or
chamfering corners as directed and raking out joints including throating, nosing and drip
course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping
over concrete surface]
S.O.R.,PWD,GOVT OF
7 With 1:4 cement mortar WB,ITEM 1/ii/a, b & c ,
PAGE 189 OF 315
(A) 20 mm thick plaster - External Wall Sqm 272.390 170 46306.4
(B) 15 mm thick plaster - Internal Wall Sqm 299.966 149 44694.9
(C ) 10 mm thick plaster - Ceilling Sqm 179.786 121 21754.1
Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
8 NOTE:Cement 0.152 cu.m per100 sq.m. Sqm 33.051 0
Supplying and laying true to line and level vitrified tiles of approved brand (size not less
than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement
mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM
or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone
floor/Mosaic etc without any backing course) laid after
application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with
9 admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout Sqm 340.016 2250 765036 Market Rate
materials of approved make as directed and removal of wax coating of top surface of tiles
with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete
including the cost of materials, labour and all other incidental charges complete true to the
manufacturer's
specification and direction of Engineer-in-Charge.

Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular
finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007
and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with
Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water
Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block,
Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4)
and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using
Polymerised Adhesive (6 mm thick
10 layer applied directly over finished artificial stone floor/ Mosaic etc without any backing Sqm 11.155 1357 15137.3 Market Rate
course) laid after application slurry using 1.75 Kg of cement per Sqm
below mortar only, joints grouted with admixture of white cement and colouring pigment to
match with colour of tiles/ epoxy grout materials of approved make as directed and removal
of wax coating of top surface of tiles with warm water and polishing the tiles using soft and
dry cloth upto mirror finish complete including
the cost of materials, labour and all other incidental charges complete true to the
manufacturer's specification and direction of Engineer-in-Charge.

Wood work in door and window frame fitted and fixed in position complete including a
protective coat of painting at the contact surface of the frame exluding cost of concrete,
Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). S.O.R.,PWD,GOVT OF
11 Cum 4 72954 291816 WB,ITEM 1/d,PAGE 114
Sal : Local. OF 315

Supplying solid flush type doors of commercial quality, the timber frame consisting of top
and bottom rails and side styles of well seasoned timber 65mm wide each and the entire
frame fitted with 37.5mm wide battens places both ways in order to make the door of solid
core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as S.O.R.,PWD,GOVT OF
12 glue etc. complete, including fitting, fixing shutters in position but excluding the cost of Sqm 10.08 2659 26802.7 WB,ITEM 11/a ,PAGE
hinges and other fittings in ground floor. 124 OF 315
(a) 35 mm thick shutters (single leaf)

M.S. works in framed gratings of window etc.made of round or square bars and frame work
or M.S. flats (with the bars securely fixed to the flat bar frame) with or without intermediate S.O.R.,PWD,GOVT OF
13 flat bar stiffener and fixed with necessary screws etc. complete, as directed. Quntl. 42.48 6299 267582 WB,ITEM 12,PAGE 104
Sl No Particulars No. (N) Length (L) Breadth/ Depth/ Qty Remarks
Width (W) Height (H)
Applying Interior grade Acrylic Primer of approved quality and brand on plastered or
cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including
14 scraping and preparing the surface throughly, complete as per manufacturer's specification Sqm 479.751 625.0 299845 Market Rate
and as per direction of the EIC.

Applying Exterior grade Acrylic primer of approved quality and brand on plastered or
cencrete surface old or new surface to receive decorative textured (matt finish) or smooth
finish acrylic exterior emulsion paint including scraping and preparing the surface throughly,
15 complete as per manufacturer's specification and as per direction of the EIC. Sqm 544.781 475.0 258771 Market Rate

Total (A) 2740344


16 Extra for Electrical an plumbing work(B) 500000
Total (A+B) 3240344
SAY RUPEES THIRTY LAKH FOURTY THOUSAND THREE HUNDRED FOURTY FOUR ONLY