Professional Documents
Culture Documents
Sizing Knock-Out Drums - API521
Sizing Knock-Out Drums - API521
Uv = 1.74 m s-1
Vapour Flowrate = 0.99 m3 s-1
Vapour Flow Area = 0.57 m2
With vapour area occupying half the drum area, the drum diameter, Dd, is:
Dd = 1.20 m
Uv = 2.28 m s-1
Vapour Flowrate = 2.97 m3 s-1
Vapour Flow Area = 1.30 m2
With vapour area occupying half the drum area, the drum diameter, Dd, is:
Dd = 1.82 m
Uv = 1.63 m s-1
Vapour Flowrate = 1.45 m3 s-1
Vapour Flow Area = 0.89 m2
With vapour area occupying half the drum area, the drum diameter, Dd, is:
Dd = 1.50 m
Uv = 2.19 m s-1
Vapour Flowrate = 2.61 m3 s-1
Vapour Flow Area = 1.19 m2
With vapour area occupying half the drum area, the drum diameter, Dd, is:
Dd = 1.74 m
Uv = 1.35 m s-1
Vapour Flowrate = 1.00 m3 s-1
Vapour Flow Area = 0.74 m2
With vapour area occupying half the drum area, the drum diameter, Dd, is:
Dd = 1.37 m