You are on page 1of 3

COLUMN DESIGN SUMMARY

Project Name : Proposed Two Storey Residential Building (Column)


Client Name : Marvin B. Vales
Engineer Name : JRC
Design File : D:\EUGENE\MBV\Proposed Two Storey Residential Building (MBV)-Column-
1.rcdx
Analysis File : D:\EUGENE\MBV\Proposed Two Storey Residential Building (MBV).STD
Analysis Last Modified : 21/01/2023 2:20:15 pm

Design Code: ACI 318M - 2014


Load Combinations :
29. 1.4 (LOAD 9: DL)
30. 1.2 (LOAD 9: DL) +1.6 (LOAD 10: LL) +0.5 (LOAD 11: LLR)
31. 1.2 (LOAD 9: DL) +(LOAD 10: LL) +1.6 (LOAD 11: LLR)
32. 1.2 (LOAD 9: DL) +0.5 (LOAD 12: WL +X) +1.6 (LOAD 11: LLR)
33. 1.2 (LOAD 9: DL) +0.5 (LOAD 13: WL -X) +1.6 (LOAD 11: LLR)
34. 1.2 (LOAD 9: DL) +0.5 (LOAD 14: WL +Z) +1.6 (LOAD 11: LLR)
35. 1.2 (LOAD 9: DL) +0.5 (LOAD 15: WL -Z) +1.6 (LOAD 11: LLR)
36. 1.2 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 12: WL +X) +0.5 (LOAD 11: LLR)
37. 1.2 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 13: WL -X) +0.5 (LOAD 11: LLR)
38. 1.2 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 14: WL +Z) +0.5 (LOAD 11: LLR)
39. 1.2 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 15: WL -Z) +0.5 (LOAD 11: LLR)
40. 0.9 (LOAD 9: DL) +(LOAD 12: WL +X)
41. 0.9 (LOAD 9: DL) +(LOAD 13: WL -X)
42. 0.9 (LOAD 9: DL) +(LOAD 14: WL +Z)
43. 0.9 (LOAD 9: DL) +(LOAD 15: WL -Z)
44. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 1: EQ +X +E)
45. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 2: EQ +X -E)
46. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 3: EQ -X +E)
47. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 4: EQ -X -E)
48. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 5: EQ +Z +E)
49. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 6: EQ +Z -E)
50. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 7: EQ -Z +E)
51. 1.52 (LOAD 9: DL) +(LOAD 10: LL) +(LOAD 8: EQ -Z -E)
52. 1.22 (LOAD 9: DL) +(LOAD 1: EQ +X +E)
53. 1.22 (LOAD 9: DL) +(LOAD 2: EQ +X -E)
54. 1.22 (LOAD 9: DL) +(LOAD 3: EQ -X +E)
55. 1.22 (LOAD 9: DL) +(LOAD 4: EQ -X -E)
56. 1.22 (LOAD 9: DL) +(LOAD 5: EQ +Z +E)
57. 1.22 (LOAD 9: DL) +(LOAD 6: EQ +Z -E)
58. 1.22 (LOAD 9: DL) +(LOAD 7: EQ -Z +E)
59. 1.22 (LOAD 9: DL) +(LOAD 8: EQ -Z -E)
60. 0.58 (LOAD 9: DL) +(LOAD 1: EQ +X +E)
61. 0.58 (LOAD 9: DL) +(LOAD 2: EQ +X -E)
62. 0.58 (LOAD 9: DL) +(LOAD 3: EQ -X +E)
63. 0.58 (LOAD 9: DL) +(LOAD 4: EQ -X -E)
64. 0.58 (LOAD 9: DL) +(LOAD 5: EQ +Z +E)
65. 0.58 (LOAD 9: DL) +(LOAD 6: EQ +Z -E)
66. 0.58 (LOAD 9: DL) +(LOAD 7: EQ -Z +E)
67. 0.58 (LOAD 9: DL) +(LOAD 8: EQ -Z -E)

Levels : 1. FOUNDATION
2. 0m
3. 3.9m
4. 6.9m

1
Column/Wall : C1
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 64 236 20.79 1.49 31.31 1.79 0.65 8-#16
300 Fy276 @ 150

Column/Wall : C2
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 64 236 68.57 0.35 29.98 1.79 0.56 8-#16
300 Fy276 @ 150

Column/Wall : C4
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 62 234 -38.14 28 -5.84 1.79 0.66 8-#16
300 Fy276 @ 150
300 X C21 : #10 @ 75 + #10
2 TO 3 50 222 115.72 0.23 29.91 1.79 0.52 8-#16
300 Fy276 @ 150
300 X C21 : #10 @ 75 + #10
3 TO 4 39 211 20.56 -0.86 10.05 1.79 0.21 8-#16
300 Fy276 @ 150

Column/Wall : C5
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 59 231 14.62 1.97 -33.08 1.79 0.69 8-#16
300 Fy276 @ 150
300 X C21 : #10 @ 75 + #10
2 TO 3 67 239 -7.7 2.65 23.6 1.79 0.52 8-#16
300 Fy276 @ 150

Column/Wall : C6
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
3 TO 4 51 223 36.35 6.07 15.28 1.79 0.33 8-#16
300 Fy276 @ 150

Column/Wall : C7
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 60 232 110.56 -28.2 -1.28 1.79 0.49 8-#16
300 Fy276 @ 150

Column/Wall : C9
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 67 239 -3.14 1.2 -28.88 1.79 0.63 8-#16
300 Fy276 @ 150
300 X C21 : #10 @ 75 + #10
3 TO 4 51 223 1.5 3.9 9.84 1.79 0.22 8-#16
300 Fy276 @ 150

Column/Wall : C10
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
3 TO 4 38 210 20.39 1.43 13.55 1.79 0.28 8-#16
300 Fy276 @ 150

Column/Wall : C11

2
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
1 TO 2 66 238 -0.73 -2.51 -30.59 1.79 0.66 8-#16
300 Fy276 @ 150
300 X C21 : #10 @ 75 + #10
3 TO 4 47 219 15.92 7.28 7.55 1.79 0.22 8-#16
300 Fy276 @ 150

Column/Wall : C12
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
2 TO 3 47 219 49.07 37.3 1.23 1.79 0.73 8-#16
300 Fy276 @ 150

Column/Wall : C14
Level Size Material LC Analysis P (kN) Mx My Pt (%) Interaction Main Links
(mm) LC No (kNm) (kNm) Ratio Reinforcement
300 X C21 : #10 @ 75 + #10
2 TO 3 45 217 -0.93 -24.47 -7.19 1.79 0.54 8-#16
300 Fy276 @ 150