You are on page 1of 2

1.

Tracker Dead Load


Tracker dead load for single row = Motor load +2x(sum of array pier loads) [Refer Topl unfactored DL ]

Tracker dead load for single row = 11412 lbs

Tracker Length = 420 ft

Tracker dead load in plf = 11412lbs/420 ft= 27.17 plf

2. Snow Load

Roof Snow Load in plf = 8.806psf x 7.47 ft = 65.81 plf [Roof snow load x Module length]

20% Roof snow load in plf = 0.2x 65.81 plf = 13.162 plf [As per Asce7 section 12.7.2]

Tracker Length = 420 ft

Snow dead load for seismic consideration = 13.162plfx420 ft= 5528 lbs

Table showing Snow load calculation for different tilts


3. Seismic Load calculation: [ Ez]

Tracker Dead load = 11412 lbs

20% Snow load = 5528 lbs

Total Load for Seismic consideration (W)= 11412 lbs + 5528 lbs = 16940 lbs

Total Seismic Load =Ez =Cs x W =0.207x16940 lbs = 3506.6 lbs