You are on page 1of 6

Wings Elevator & Engineering Private Limited

GST NO.:
19AADCWo959N 1ZN
Head Office: Rangoli Building 153, B.T. Road, Dunlop, Kolkata 700108
Corporate office: FE 209, Sector l , Salt Lake, Kolkata 700106
PTERYLAE WINO Phone: +91 8274050331 /+91 9903750331
GROU
We sow wi Email: wingselevator.engineering@gmail.com
Website : pwgroup.in

Ref: WEM/AMC/20-23/AKDS-251/116 Date: 25/11/2022

A.M.C Contract
TO,
P.C Chandra & Sons ( India) Pvt Ltd
127/1A, BB Ganguly street, Lebutala
Bowbazar, Kolkata

Dear Sir/ Madam

Sub:AMC Proposal For Two Number GMV Make Hydraulic Liftat the Above Premises.
Under this contract we shall maintain the elevator equipment's of the following terms and
conditions.

1. OUR SERVICE cOVERS


We will use specially trained personnel under our supervision who are qualified to
keep your lift in proper and safe operating condition.
We shall carry out servicing and inspection of the elevator once in two month.
o We shall regularly examine, Iubricate, adjust the elevator equipment's.
We shall be periodically examine all safety devices.
o W e shall attend break-down as and when called for and same will be attended within normal
working hour i.e. from 10 A.M - 5 P.M.

o If there is any breakdown after 6 P.M. or any holiday same will be attended nextday.
o Points with are to be consider in normal breakdown conditions
o Incase of extreme emergency same will be attended on priority.
o Incase of unavailabbility of any faulty makers spare parts,owner will provide exceeded time
to procure part from makers. (Effort shall be made to obtain the spares with in 7 Days).

Signature- Wings evator & Enginéering Ryt Ltd Signature-Customer


Wings Elevator & Engineering Private Limited
GST NO. : 19AADCWo959N1ZN
Head Office: Rangoll Bulding 153, B.T. Road, Dunlop, Kolkata 700108
Corporate office: FE 209, Sector Il,, Salt Lake, Kolkata 700106
Phone: +91 8274050331/+91 9903750331
PTERYLAE WINGS aROUP
Email: wingselevator.engineering@gmall.com
re
Website: pwgroup.in

2.Covered within purview of AMC


2.1 Monthly checks
Ride each elevator and observe performance, leveling, floor stops, door opening and closing
operation and noise
Test door, detectors, door open buttons, and alarm bell.
Rope lubrication to be carried out.
Check for and
indicator.
Clean and inspect power unit, controller and motor. all
proper car and hall button operation
Check drive motor coupling and oil seal
Check for leaks and oil level in power unit.
Clean and inspect car top, operating switches, door operator and controls, car door hangers,
gibs. Lubricate and adjust door operator and door equipment
Clean and inspect hoist way door hangers, interlocks, door gibs, and hoist way switches.
Clean and inspect hydraulic plunger, seals and packing.
Check guide rail lubrication drip containers in pit.
Cleaning of lift pit
Check UPS operation.
Cleaning of lift pit as required
All safety check and connection checks to be carried out .
Check light and replacement of lamps
Note: The entire check list should have to be sign. by both parties and only afterthat checking
will be treat as complete. checking date shall be firm for every months. O

2.2
2.2 Quarte rly Checks:

Check motor and pump mounting fastenings.


Check hydraulic control valve locking nuts, adjustment screws and mounting fastenings.
Clean and adjust controller components including contacts, relays and timers.
Check transformers and rectifiers. Vacuum or brush all controller parts.
Check out complete safety circuit.
Check adjustment of slide car guides. Check bearings/liners and fastenings.
Inspect slowdown, leveling and/or limit switches.
Clean and inspect all car and hoist way door contacts and interlocks.
Check door-closing force. Check car and hoist way hangar rollers and adjust up thrusts.
Inspect door operator bearings and cams.
Note : The entire check list should have to be sign. by both parties and only after that
checking will be treat as complete. checking date shall be firm for every quaterly.

Signature- Wings Elevetor & Engineèring Pvt Ltd Signature-Customer


Wings Elevator & Engineering Private Limited
GST NO.:
19AADCWo959N1ZN
Hoad Office: Rangoli Building 153, B.T. Road, Dunlop, Kolkata 700108
Corporate Office: FE 209, Sector 11,, Sait Lake, Kolkata 700106
Phone: +91 8274050331/+91 9903750331
PTERYLAK WINGS GRoup
w e g r e w with yeu Email: wingselovator.engineering@gmail.com
Website: pwgroup.in

2.3 Semi Annual:

Check control and main line fuses, voltage readings and motor wire connections.
Check motor overload devices, resistor/resistance connections and starters, contactors and
contacts
Note: The entire check list should have to be sign. by both parties and only afterthat checking will
be treat a s complete. checking date shall be firm for every half yearly.

2.4 Annual:

Check all controller terminals. Check and clean all fuse holders.
Check car frame, sills and pit.
Clean hoistway and hoistway equipment including guide rails, hoistway doorhangars,
interlocks, closers, headers and related devices.
Check all fastenings on guide rails, brackets and entrances.
Check traveling cables
Check rope tension and calculate extension
enclousure should be check anually for any watrer ingress and rectification if any in
discussion with owner and rectification cost
Note The entire check list should have to be sign. by both parties and only afterthat
checking will be treat as complete. Checking date shall be firm for every yearly.

3. OWNERS RESPONSIBILITIES
Cleaning and white washing of the elevator hoist way and machine room will be carried out

by company on o w n e r s cost or extra cost .

4.DETALS OF ELEVATOR:
No. of Elevator & Make Two/ GMV Make
No. of Stops G+3, 4 stops /4 openings
Capacity of Elevator 8 Persons / 544 KGs
Type of Elevator Passenger
Function of Elevator . Hydraulic.

OG
Signature- Wings Elevator & Engineering Pvt Ltd Signature-Customer
Wings Elevator & Engineering Private Limited
aST NO. 1 19AADCWo950N1ZN

Head Office: Rangoli Bullding 103,


D.T. Road, Dunlop, Kolkata 700108
Corporate Office: FE 209, Sector Il,, Salt Lake, Kolkata 70010
PTERY AR WINGs e n o u Phone: +91 0274050331/+91 09037603311
W rOw wihveu Email: wingselovator.engineering@gmall.com
Website pwgroup.in

REPAIROR REPLACEMENT OF THE FOLLOWING PARTSINCLuDEDIN THIs cONTRACT


Oil and grease for lubrication
Landing gate lock contact (Fixed with landing gate post).
Car gate switch (Fixed on top of car, operated by car gate).
Safety switch (Fixed with safety assembly).
Floor stop switch (Fixed at each landing).
Up-Dn Final limit contacts ( Fixed at top and ground
Governor switch (Fixed with governor).
Car guide shoe (Fixed with car
Rail guide shoe (Fixed with counter weight)
Coil/ Relay - fixed with controller.

Lift and Structure cleaning from inside


Note: System oil (hydraulic oil ) in owners scope.

6. NOT CoVERED IN AMC


6.1 SERVICE ON CHARGEABLE BASIS INCLUDES:
All wire ropes will be renewed as an when required or as per necessity
including equalize the tension to maintain the adequate factor of safety.
Replacement of hoistway wiring, machine-room wiring and travelling
Cables.
Controller parts, car and hall-buttons, hall-position indicators.
All inter locks- hoist way, doors, hanger-guides, car door, car-door hangers, mechanis of
car-safety, mechanism of platform.Machine thrust-bearing, brake-shoe.
Alarm-bells, emergency car alarm and batteries
Solenoid Coil, Rubber Pad, Main Rope 10mm Air chord, Landing Door/ Car Door Gibs,
Encoder, Travelling Cable, Junction Box/ Maintenance Box, Contactors, Relays,
Transformer
Controller PCB, Hall Buttons/ Indicator, COP Buttons/ Indicator, Cabin Fan, Car Door
Solenoid Valve, Friction Sheave (Pulley) Diverter Pulley, Speed Governor Unit, Hall Button
Face Plate, Cabin False ceiling, Landing Door/ Car Door, Cabin Replacement, Flooring Tiles/
Checker plate, Main Piston, Hose Pipes, Valve Block, Power pack, Door drive.

Signature- wingsEtevas6&Engineering Pvt Ltd Signature-Customer


Wings Elevator & Engineering Private Limited
GST NO.:
19AADCWO95oN 1ZN
Head Office: Rangoll Bullding 153, B.T. Rosd,
Duniop. Kolkata 700108
Corporate Office: FE 200, Sector , Salt Lake, Kalkata 700106
Phone: +91 8274050331 /+91
PTRRYLAE WINOs
with
aRouP
99037 50331
Email: wingselevator.engineering@gmail.com
Website: pwgroup.in

6.2 SCOPE NOT coVERED IN AMC OR ON


CHARGEABLE BASIS:
Company shall not be responsible if any damage takes place due to misuse or negligence of
Customer, the deciding authority will be the company. The expenses for repairing of the said
damage will be born by the owner.
Rail alignment when affected by building
compression or shifting
underground hydraulic jack cylinders including underground piping and fittings
Power pack motor, valve, door-drive, warm and gear.
Installing new attachments on the elevator when recommended by insurance companies or
governmental authorities.
For maintaining the main line power feeders and associate switches and breakers.
Lighting for car interior and machine room or pit will be replaced at owners cost.
Car fans or exhaust blower, car and corridor signals including lights.
Ifany equipment has undergone for repairing the lift will be shutdown till the availability of
said spare.

7.CONTRACTUAL PERIOD &PRICE


This service shall commence on and from 1st December 2022 and continue for a period of
One year.
Contract Price Rs.300001- (Rupees Thirty Thousand only), G.s. T 18 % Extra Per Year
Rs. 30000 2=Rs.60000/-, payment in advance on yearly basis.
Our AMc Contract will be for the period of 1 years. Renewal of contract will be after one year
of completion.
Escalation of price @5%for consecutive years.
Payment will be made yearly.

(CGJe
Signature- Wings Elevator &Engineering Pvt Ltd
OLrki Signature-Customer
Wings Elevator & Engineering Private Limited
GST NO.: 19AADCWO959N1ZN
Head Office: Rangoli Building 153, B.T. Road, Duniop, Kolkata 700108
Corporate orfice: FE 209, Sector Il., Salt Lake, Kolkata 700106
Phone: +91
T E R Y A An wINGs emour 8274050331/+91 99037 50331
Email: wingselevator.engineering@gmail.com
Website :pwgroup.in

8. SPECIAL CONDITIONS

We reserve the right to suspend call back service and/ or discontinue any other work under
this contract of any other with us until all outstanding payment shall have been made as
agreed and we are assured that subsequent payment will be made as they fall due.
Company ill provide monthly once lift attendent for any special occasion without any extra charges
from 10:00 AM to 05 :00 PM.
Except on Sunday and other holidays.
Company will provide lit attendent for any special occasion on per day charge of Rs.1500/- timing
10:00 AM to 06:00 PM
8 hrs duty
or for 8 hrs service in day time. For night service charges will be Rs
1000/- for
If you wish to place an order to us. Please sign and return one copy of our proposal as a
token of your acceptance for our record.

Thankingyou,

Signature of Customer

Authorised STgnatory
For WiINGs ELEVATOR
& ENGINEERING PVT LTD.
KOLKTA

Signature- Wings 5levator & Engineering Pvt Ltd


Signature-Customer

You might also like