You are on page 1of 1

raduga_fb (1907)

Sway Classification Report Calc. By:


    Rev: 1 Checked By:

Sway Classification Report


Lc : Storey Height
Δd : Average Relative Storey Drift (Δd = di - di-1)
ΣPu : Total Design Axial Loads at Critical Combination
Cmb : Maximum Q value at Critical Combination
ΣVus : Total Design Shear Forces at Critical Combination
βs : Magnification Factor for Storey
Q : Stability Coefficient Q=(ΣPu * Δd)(ΣVus * Lc)

Dir: 1 - STOREY SWAY CHECK


Lc Δd ΣPu ΣVus
Storey Comb βs Q Status
(mm) (mm) (kN) (kN)
1 600             0.00         1770.1             63.3 4 1.000       0.000143≤    0.05 Non-Sway
2 1575             0.00               0.0               0.0 1 1.000     0.000E+00≤    0.05 Non-Sway
3 1575             0.04         4175.7             43.3 4 1.003       0.002733≤    0.05 Non-Sway
4 1575             0.00               0.0               0.0 1 1.000     0.000E+00≤    0.05 Non-Sway
5 1575             0.39         2224.4             23.6 4 1.024       0.023629≤    0.05 Non-Sway
6 3150             0.43           829.3               9.1 4 1.013       0.012461≤    0.05 Non-Sway

Dir: 2 - STOREY SWAY CHECK


Lc Δd ΣPu ΣVus
Storey Comb βs Q Status
(mm) (mm) (kN) (kN)
1 600             0.00         1773.3             63.3 6 1.000     8.033E-05≤    0.05 Non-Sway
2 1575             0.00               0.0               0.0 1 1.000     0.000E+00≤    0.05 Non-Sway
3 1575             0.10         4172.4             43.3 6 1.006       0.006260≤    0.05 Non-Sway
4 1575             0.00               0.0               0.0 1 1.000     0.000E+00≤    0.05 Non-Sway
5 1575             0.53         2224.4             23.6 6 1.033       0.031743≤    0.05 Non-Sway
6 3150             0.49           829.3               9.1 6 1.014       0.014271≤    0.05 Non-Sway

ProtaStructure v6.0.392 Page 1