OF AREA
REMARKS REFERENCES
PERSON PERSONS (SQ.M)
Convention hall 1.5 sqm 155 235 sqm Large, versatile space for events and gatherings. National Building Code of the Philippines (NBCP)
Space for showcasing exhibits or displays, with flexibility in
Main Exhibit 1.0 sqm 700 700 sqm National Building Code of the Philippines (NBCP)
design.
ArtGallery 1.0 sqm 100 100 sqm Space specifically designed for art displays. National Building Code of the Philippines (NBCP)
Necessary facility, should provide privacy, ventilation, and hygiene
Toilet
amenities.
1. Male 0.5 sqm 50 25 sqm National Building Code of the Philippines (NBCP)
2. Female 0.5 sqm 50 25 sqm National Building Code of the Philippines (NBCP)
3. PWD/Lactation 1.8 sqm 3 6 sqm Space Planning Guidelines
The lobby should also provide accessible routes for persons with
Lobby 1.5 sqm 65 100 sqm National Building Code of the Philippines (NBCP)
disabilities, as mandated by Batas Pambansa Bilang 344.
Rentable Space 1.5 sqm 130 200 sqm National Building Code of the Philippines (NBCP)
Café
Area for preparing food and other items for service. May include
1. Service and Preparation Area 5 sqm 4 20 sqm National Building Code of the Philippines (NBCP)
storage, equipment, and work surfaces.
Central kitchen space for cooking and food preparation. Should be
2. Main Kitchen 5 sqm 6 30 sqm National Building Code of the Philippines (NBCP)
designed for efficient workflow and adequate ventilation.
Necessary facility for occupants. Should provide privacy,
3. Toilet 0.5 sqm 8 4 sqm National Building Code of the Philippines (NBCP)
ventilation, and hygiene amenities.
Space for occupants to eat and socialize. Should be designed with
4. Dining Area 1.5 sqm 25 40 sqm sufficient seating, lighting, and ventilation. Acoustics and National Building Code of the Philippines (NBCP)
accessibility should also be considered.
Laundry Area
Space for washing items, such as laundry or dishes. Should be
1. Washing 5 sqm 2 10 sqm National Building Code of the Philippines (NBCP)
designed with appropriate plumbing, drainage, and ventilation.
Area for folding and sorting items after washing. Should be
2. Folding 5 sqm 3 15 sqm National Building Code of the Philippines (NBCP)
designed with work surfaces and adequate lighting.
Space for drying items, such as laundry or dishes. Should be
3. Drying 5 sqm 3 15 sqm designed with appropriate ventilation and storage for items while National Building Code of the Philippines (NBCP)
drying.
Area for sorting items before washing or storage. Should be
4. Sorting 5 sqm 4 20 sqm National Building Code of the Philippines (NBCP)
designed with adequate lighting and storage.
Space for storing items, such as cleaning supplies, laundry
5. Storage not applicable detergent, or dishes. Should be designed with appropriate shelving National Building Code of the Philippines (NBCP)
and storage solutions.
Clinic
Space for private consultations with medical professionals. Should
1. Consultation Room 7.5 sqm 3 20 sqm be designed for patient comfort, privacy, and accessibility. May National Building Code of the Philippines (NBCP)
require specialized equipment and lighting.
Necessary facility for occupants. Should provide privacy,
2. Toilet 2.5 sqm 1 2.5 sqm National Building Code of the Philippines (NBCP)
ventilation, and hygiene amenities.
Space for storing medical supplies, equipment, and records.
Should be designed with appropriate shelving and storage
3. Storage Room not applicable
solutions. May require specialized storage conditions, such as
temperature and humidity control.
Admin Office
Storage and Linens 5 sqm 3 15 sqm Storage room should have a minimum area of 2.25 square meters Time-Saver Standards
for each bed in the building, with a minimum of 7.5 square meters.