You are on page 1of 22

PV Elite® 2019

Project Data Page:


PV Elite® 2019

Table of Contents

Cover Page 1
Title Page 2
Warnings and Errors: 3
Input Echo: 4
XY Coordinate Calculations: 7
Element Original Thicknesses: 8
Internal Pressure Calculations: 9
External Pressure Calculations: 13
Element and Detail Weights: 16
Center of Gravity Calculation: 17
MDMT Summary: 18
Vessel Design Summary: 19
Cover Page PV Elite® 2019

DESIGN CALCULATION

In Accordance with ASME Section VIII Division 1

ASME Code Version : 2017

Analysis Performed by : SPLM Licensed User

Job File : C:\USERS\ALEXA\ONEDRIVE\CALCULOS PVELITE\ACELEN\

Date of Analysis : Oct 14,2022 12:17pm

PV Elite 2019 SP1, March 2019


Title Page PV Elite® 2019

Note:
PV Elite performs all calculations internally in Imperial Units
to remain compliant with the ASME Code and any built in assumptions
in the ASME Code formulas. The finalized results are reflected to show
the user's set of selected units.
® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 3 of 20
Warnings and Errors: Step: 0 12:17pm Oct 14,2022

Class From To : Basic Element Checks.


==========================================================================

Class From To: Check of Additional Element Data


==========================================================================
Please insure the C factor entered is in accordance with Figure UG-34.
Warning: Flat head diameter not consistent with attached element.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 4 of 20
Input Echo: Step: 1 12:17pm Oct 14,2022

PV Elite Vessel Analysis Program: Input Data

Design Internal Pressure (for Hydrotest) 7.0307 kgf/cm²


Design Internal Temperature 93.3 °C
Type of Hydrotest not Specified
Hydrotest Position Horizontal
Projection of Nozzle from Vessel Top 0 mm
Projection of Nozzle from Vessel Bottom 0 mm
Minimum Design Metal Temperature 10.0 °C
Type of Construction Press. Welded
Special Service None
Degree of Radiography RT-1
Use Higher Longitudinal Stresses (Flag) Y
Select t for Internal Pressure (Flag) N
Select t for External Pressure (Flag) N
Select t for Axial Stress (Flag) N
Select Location for Stiff. Rings (Flag) N
Consider Vortex Shedding N
Perform a Corroded Hydrotest N

Load Case 1 NP+EW+WI+FW+BW


Load Case 2 NP+EW+EE+FS+BS
Load Case 3 NP+OW+WI+FW+BW
Load Case 4 NP+OW+EQ+FS+BS
Load Case 5 NP+HW+HI
Load Case 6 NP+HW+HE
Load Case 7 IP+OW+WI+FW+BW
Load Case 8 IP+OW+EQ+FS+BS
Load Case 9 EP+OW+WI+FW+BW
Load Case 10 EP+OW+EQ+FS+BS
Load Case 11 HP+HW+HI
Load Case 12 HP+HW+HE
Load Case 13 IP+WE+EW
Load Case 14 IP+WF+CW
Load Case 15 IP+VO+OW
Load Case 16 IP+VE+EW
Load Case 17 NP+VO+OW
Load Case 18 FS+BS+IP+OW
Load Case 19 FS+BS+EP+OW

Wind Design Code ASCE-7 93


Basic Wind Speed [V] 112.65 km/hr
Surface Roughness Category C: Open Terrain
Importance Factor 1.0
Type of Surface Moderately Smooth
Base Elevation 0 cm
Percent Wind for Hydrotest 33.0
Using User defined Wind Press. Vs Elev. N
Damping Factor (Beta) for Wind (Ope) 0.0100
Damping Factor (Beta) for Wind (Empty) 0.0000
Damping Factor (Beta) for Wind (Filled) 0.0000

Seismic Design Code UBC 94


UBC Seismic Zone (1=1,2=2a,3=2b,4=3,5=4) 0.000
UBC Importance Factor 1.000
UBC Soil Type S1
UBC Horizontal Force Factor 3.000
UBC Percent Seismic for Hydrotest 0.000

Design Pressure + Static Head Y


Consider MAP New and Cold in Noz. Design N
Consider External Loads for Nozzle Des. Y
Use ASME VIII-1 Appendix 1-9 N
® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 5 of 20
Input Echo: Step: 1 12:17pm Oct 14,2022

Material Database Year Current w/Addenda or Code Year

Configuration Directives:

Do not use Nozzle MDMT Interpretation VIII-1 01-37 No


Use Table G instead of exact equation for "A" Yes
Shell Head Joints are Tapered Yes
Compute "K" in corroded condition Yes
Use Code Case 2286 No
Use the MAWP to compute the MDMT Yes
For thickness ratios <= 0.35, MDMT will be -155F (-104C) Yes
For PWHT & P1 Materials the MDMT can be < -55F (-48C) No

Using Metric Material Databases, ASME II D No


Calculate B31.3 type stress for Nozzles with Loads Yes
Reduce the MDMT due to lower membrane stress Yes
Consider Longitudinal Stress in MDMT calcs. (Div. 1) No

Complete Listing of Vessel Elements and Details:

Element From Node 10


Element To Node 20
Element Type Flat
Description Tampo Plano
Distance "FROM" to "TO" 6.8 cm
Inside Diameter 823 mm
Element Thickness 68 mm
Internal Corrosion Allowance 3.175 mm
Nominal Thickness 68 mm
External Corrosion Allowance 0 mm
Design Internal Pressure 35.4 kgf/cm²
Design Temperature Internal Pressure 150 °C
Design External Pressure 0 kgf/cm²
Design Temperature External Pressure 25 °C
Effective Diameter Multiplier 1.2
Material Name SA-516 60
Allowable Stress, Ambient 1202.2 kgf/cm²
Allowable Stress, Operating 1202.2 kgf/cm²
Allowable Stress, Hydrotest 1562.9 kgf/cm²
Material Density 0.00775 kg/cm³
P Number Thickness 30.988 mm
Yield Stress, Operating 1988.3 kgf/cm²
UCS-66 Chart Curve Designation C
External Pressure Chart Name CS-2
UNS Number K02100
Product Form Plate
Efficiency, Longitudinal Seam 1
Efficiency, Circumferential Seam 0.7
Flat Head Attachment Factor 0.1
Small diameter if Non-Circular 0 mm
Weld is pre-Heated No

Element From Node 20


Element To Node 30
Element Type Cylinder
Description Carretel
Distance "FROM" to "TO" 76.6 cm
Inside Diameter 686 mm
Element Thickness 12.5 mm
Internal Corrosion Allowance 0 mm
Nominal Thickness 12.5 mm
External Corrosion Allowance 0 mm
® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 6 of 20
Input Echo: Step: 1 12:17pm Oct 14,2022

Design Internal Pressure 35.4 kgf/cm²


Design Temperature Internal Pressure 150 °C
Design External Pressure 0 kgf/cm²
Design Temperature External Pressure 25 °C
Effective Diameter Multiplier 1.2
Material Name SA-516 60
Efficiency, Longitudinal Seam 1.0
Efficiency, Circumferential Seam 1.0
Weld is pre-Heated No

Element From Node 30


Element To Node 40
Element Type Cylinder
Description Casco
Distance "FROM" to "TO" 450 cm
Inside Diameter 686 mm
Element Thickness 19 mm
Internal Corrosion Allowance 0 mm
Nominal Thickness 19 mm
External Corrosion Allowance 0 mm
Design Internal Pressure 35.4 kgf/cm²
Design Temperature Internal Pressure 150 °C
Design External Pressure 0 kgf/cm²
Design Temperature External Pressure 25 °C
Effective Diameter Multiplier 1.2
Material Name SA-516 60
Efficiency, Longitudinal Seam 1.0
Efficiency, Circumferential Seam 1.0
Weld is pre-Heated No

Element From Node 40


Element To Node 50
Element Type Torisphe.
Description
Distance "FROM" to "TO" 5.08 cm
Inside Diameter 686 mm
Element Thickness 25 mm
Internal Corrosion Allowance 0 mm
Nominal Thickness 25 mm
External Corrosion Allowance 0 mm
Design Internal Pressure 35.4 kgf/cm²
Design Temperature Internal Pressure 150 °C
Design External Pressure 1.0546 kgf/cm²
Design Temperature External Pressure 25 °C
Effective Diameter Multiplier 1.2
Material Name SA-516 60
Efficiency, Longitudinal Seam 1.0
Efficiency, Circumferential Seam 1.0
Tori Head Crown Radius 736 mm
Tori Head Knuckle Radius 44.16 mm
Weld is pre-Heated No

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 7 of 20
XY Coordinate Calculations: Step: 2 12:17pm Oct 14,2022

XY Coordinate Calculations:

From To X (Horiz.) Y (Vert.) DX (Horiz.) DY (Vert.)


cm cm cm cm

Tampo Plano 6.8 ... 6.8 ...


Carretel 83.4 ... 76.6 ...
Casco 533.4 ... 450 ...
40 50 538.48 ... 5.08 ...

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 8 of 20
Element Original Thicknesses: Step: 3 12:17pm Oct 14,2022

The final thicknesses shown in the table below were changed for
one or more of the following reasons:

Thickness increased due to Internal Pressure

From Node To Node Original Thickness Final Thickness mm


10 20 68.00 68.00
20 30 12.50 12.50
30 40 19.00 19.00
40 50 25.00 25.00

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 9 of 20
Internal Pressure Calculations: Step: 4 12:17pm Oct 14,2022

Element Thickness, Pressure, Diameter and Allowable Stress :

Int. Press Nominal Total Corr Element Allowable


From To + Liq. Hd Thickness Allowance Diameter Stress(SE)
kgf/cm² mm mm mm kgf/cm²

Tampo Plano 35.4 68 3.175 823 1202.2


Carretel 35.4 12.5 ... 686 1202.2
Casco 35.4 19 ... 686 1202.2
40 50 35.4 25 ... 686 1202.2

Element Required Thickness and MAWP :

Design M.A.W.P. M.A.P. Minimum Required


From To Pressure Corroded New & Cold Thickness Thickness
kgf/cm² kgf/cm² kgf/cm² mm mm

Tampo Plano 35.4 105.397 118.131 68 40.744


Carretel 35.4 42.8762 42.8762 12.5 10.2812
Casco 35.4 64.4547 64.4547 19 10.2812
40 50 35.4 45.9513 45.9513 25 19.2426

Minimum 42.876 42.876

MAWP: 42.876 kgf/cm², limited by: Carretel.

Internal Pressure Calculation Results :

ASME Code, Section VIII Division 1, 2017

Welded Flat Head From 10 To 20 SA-516 60 , UCS-66 Crv. C at 150 °C

Tampo Plano

Longitudinal Joint: Full Radiography per UW-11(a) Type 2


Circumferential Joint: Full Radiography per UW-11(a) Type 2

Material UNS Number: K02100

Required Thickness due to Internal Pressure [tr]:


= d * sqrt(Z*C*P/(S*E)) per UG-34 (c)(3)
= 692.35*sqrt(1.0*0.1*35.4/(1202.25*1.0))
= 37.5690 + 3.1750 = 40.7440 mm

Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:


= (t/d)²*((S*E)/(C*Z)) UG-34 (c)(3)
= (64.825/692.35))²*((1202.25*1.0)/(0.1*1.0))
= 105.397 kgf/cm²

Maximum Allowable Pressure, New and Cold [MAPNC]:


= (t/d)²*((S*E)/(C*Z)) per UG-34 (c) (3)
= (68.0/686.0)²*((1202.25*1.0)/(0.1*1.0))
= 118.131 kgf/cm²

Actual stress at given pressure and thickness, corroded [Sact]:


= (Z*C*P)/(((t/d)²)*E)
= (1.0*0.1*35.4)/(((64.825/692.35)²)*1.0)
= 403.803 kgf/cm²

Minimum Design Metal Temperature Results:

tg = 17.0, tg_sr = 68.0, tr = 41.346, c = 3.175 mm, E* = 1.0


® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 10 of 20
Internal Pressure Calculations: Step: 4 12:17pm Oct 14,2022

Thickness Ratio = tr * (E*)/(tg_sr - c) = 0.638, Temp. Reduction = 20 °C

Min Metal Temp. w/o impact per UCS-66, Curve C -31 °C


Min Metal Temp. at Required thickness (UCS 66.1) -48 °C

Note:
Post Weld Heat Treatment is required for this Element/Joint and it was
specified as being heat treated.

Cylindrical Shell From 20 To 30 SA-516 60 , UCS-66 Crv. C at 150 °C

Carretel

Material UNS Number: K02100

Required Thickness due to Internal Pressure [tr]:


= (P*R)/(S*E-0.6*P) per UG-27 (c)(1)
= (35.4*343.0)/(1202.25*1.0-0.6*35.4)
= 10.2812 + 0.0000 = 10.2812 mm

Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:


= (S*E*t)/(R+0.6*t) per UG-27 (c)(1)
= (1202.25*1.0*12.5)/(343.0+0.6*12.5)
= 42.876 kgf/cm²

Maximum Allowable Pressure, New and Cold [MAPNC]:


= (S*E*t)/(R+0.6*t) per UG-27 (c)(1)
= (1202.25*1.0*12.5)/(343.0+0.6*12.5)
= 42.876 kgf/cm²

Actual stress at given pressure and thickness, corroded [Sact]:


= (P*(R+0.6*t))/(E*t)
= (35.4*(343.0+0.6*12.5))/(1.0*12.5)
= 992.616 kgf/cm²

% Elongation per Table UG-79-1 (50*tnom/Rf*(1-Rf/Ro)) 1.790 %

Minimum Design Metal Temperature Results:

Govrn. thk, tg = 12.5, tr = 12.5, c = 0.0 mm, E* = 1.0


Thickness Ratio = tr * (E*)/(tg - c) = 1.0, Temp. Reduction = 0 °C

Min Metal Temp. w/o impact per UCS-66, Curve C -38 °C

Cylindrical Shell From 30 To 40 SA-516 60 , UCS-66 Crv. C at 150 °C

Casco

Material UNS Number: K02100

Required Thickness due to Internal Pressure [tr]:


= (P*R)/(S*E-0.6*P) per UG-27 (c)(1)
= (35.4*343.0)/(1202.25*1.0-0.6*35.4)
= 10.2812 + 0.0000 = 10.2812 mm

Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:


= (S*E*t)/(R+0.6*t) per UG-27 (c)(1)
= (1202.25*1.0*19.0)/(343.0+0.6*19.0)
= 64.455 kgf/cm²

Maximum Allowable Pressure, New and Cold [MAPNC]:


= (S*E*t)/(R+0.6*t) per UG-27 (c)(1)
= (1202.25*1.0*19.0)/(343.0+0.6*19.0)
® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 11 of 20
Internal Pressure Calculations: Step: 4 12:17pm Oct 14,2022

= 64.455 kgf/cm²

Actual stress at given pressure and thickness, corroded [Sact]:


= (P*(R+0.6*t))/(E*t)
= (35.4*(343.0+0.6*19.0))/(1.0*19.0)
= 660.303 kgf/cm²

% Elongation per Table UG-79-1 (50*tnom/Rf*(1-Rf/Ro)) 2.695 %

Minimum Design Metal Temperature Results:

Govrn. thk, tg = 19.0, tr = 12.5, c = 0.0 mm, E* = 1.0


Thickness Ratio = tr * (E*)/(tg - c) = 0.658, Temp. Reduction = 19 °C

Min Metal Temp. w/o impact per UCS-66, Curve C -28 °C


Min Metal Temp. at Required thickness (UCS 66.1) -47 °C

Torispherical Head From 40 To 50 SA-516 60 , UCS-66 Crv. C at 150 °C

Material UNS Number: K02100

Inside Corroded Head Depth [h]:


= L - sqrt( ( L - Di / 2) * ( L + Di / 2 - 2 * r ) )
= 736.0-sqrt((736.0-686.0/2)*(736.0+686.0/2-2*44.16))
= 112.031 mm

M factor for Torispherical Head:


= (3+sqrt((L+C)/(r+C)))/4 per Appendix 1-4 (b & d)
= (3+sqrt((736.0+ 0.0)/(44.16+ 0.0)))/4
= 1.7706

Note: The knuckle radius r is less than 3 times the head thickness.
Please check UG-32(j) and UG-81 for Code compliance.

Required Thickness due to Internal Pressure [tr]:


= (P*L*M)/(2*S*E-0.2*P) per Appendix 1-4 (d)
= (35.4*736.0*1.7706)/(2*1202.25*1.0-0.2*35.4)
= 19.2426 + 0.0000 = 19.2426 mm

Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:


= (2*S*E*t)/(M*L+0.2*t) per Appendix 1-4 (d)
= (2*1202.25*1.0*25.0)/(1.7706*736.0+0.2*25.0)
= 45.951 kgf/cm²

Maximum Allowable Pressure, New and Cold [MAPNC]:


= (2*S*E*t)/(M*L+0.2*t) per Appendix 1-4 (d)
= (2*1202.25*1.0*25.0)/(1.7706*736.0+0.2*25.0)
= 45.951 kgf/cm²

Actual stress at given pressure and thickness, corroded [Sact]:


= (P*(M*L+0.2*t))/(2*E*t)
= (35.4*(1.7706*736.0+0.2*25.0))/(2*1.0*25.0)
= 926.189 kgf/cm²

Straight Flange Required Thickness:


= (P*R)/(S*E-0.6*P) + c per UG-27 (c)(1)
= (35.4*343.0)/(1202.25*1.0-0.6*35.4)+0.0
= 10.281 mm

Straight Flange Maximum Allowable Working Pressure:


= (S*E*t)/(R+0.6*t) per UG-27 (c)(1)
= (1202.25 * 1.0 * 25.0)/(343.0 + 0.6 * 25.0 )
= 83.956 kgf/cm²
® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 12 of 20
Internal Pressure Calculations: Step: 4 12:17pm Oct 14,2022

Percent Elong. per UCS-79, VIII-1-01-57 (75*tnom/Rf)*(1-Rf/Ro) 33.092 %


Note: Please Check Requirements of UCS-79 as Elongation is > 5%.

MDMT Calculations in the Knuckle Portion:

Govrn. thk, tg = 25.0, tr = 23.321, c = 0.0 mm, E* = 1.0


Thickness Ratio = tr * (E*)/(tg - c) = 0.933, Temp. Reduction = 4 °C

Min Metal Temp. w/o impact per UCS-66, Curve C -21 °C


Min Metal Temp. at Required thickness (UCS 66.1) -25 °C

MDMT Calculations in the Head Straight Flange:

Govrn. thk, tg = 25.0, tr = 12.5, c = 0.0 mm, E* = 1.0


Thickness Ratio = tr * (E*)/(tg - c) = 0.5, Temp. Reduction = 32 °C

Min Metal Temp. w/o impact per UCS-66, Curve C -21 °C


Min Metal Temp. at Required thickness (UCS 66.1) -48 °C

Elements Suitable for Internal Pressure.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 13 of 20
External Pressure Calculations: Step: 5 12:17pm Oct 14,2022

External Pressure Calculation Results :

External Pressure Calculations:

Section Outside Corroded Factor Factor


From To Length Diameter Thickness A B
cm mm mm kgf/cm²

10 20 No Calc ... 64.825 No Calc No Calc


20 30 535.414 711 12.5 0.00039052 398.12
30 40 535.414 724 19 0.00083363 810.734
40 50 No Calc 761 25 0.0041064 1191.74

External Pressure Calculations:

External External External External


From To Actual T. Required T. Design Pressure M.A.W.P.
mm mm kgf/cm² kgf/cm²

10 20 68 No Calc ... No Calc


20 30 12.5 No Calc ... 9.33239
30 40 19 No Calc ... 28.3682
40 50 25 2.18931 1.05461 27.5158

Minimum 9.332

External Pressure Calculations:

Actual Length Allowable Length Ring Inertia Ring Inertia


From To Bet. Stiffeners Bet. Stiffeners Required Available
cm cm cm**4 cm**4

10 20 No Calc No Calc No Calc No Calc


20 30 535.414 No Calc No Calc No Calc
30 40 535.414 No Calc No Calc No Calc
40 50 No Calc No Calc No Calc No Calc

Elements Suitable for External Pressure.

ASME Code, Section VIII Division 1, 2017

Welded Flat Head

Tampo Plano

Note: This element's required thickness was computed in the internal


Pressure Report using the maximum of the Internal and External
pressures.

Cylindrical Shell From 20 to 30 Ext. Chart: CS-2 at 25 °C

Carretel

Elastic Modulus from Chart: CS-2 at 25 °C : 0.204E+07 kgf/cm²

Results for Maximum Allowable External Pressure (MAEP):


Tca OD SLEN D/t L/D Factor A B
12.500 711.00 5354.14 56.88 7.5304 0.0003905 398.12
EMAP = (4*B)/(3*(D/t)) = (4*398.1196)/(3*56.88) = 9.3324 kgf/cm²

Results for Maximum Stiffened Length (Slen):


Tca OD SLEN D/t L/D Factor A B
® SPLM Licensed User
FileName : C-962
PV Elite 2019
PV Elite 2019 SP1 Licensee:
Page 14 of 20
External Pressure Calculations: Step: 5 12:17pm Oct 14,2022

12.500 711.00 5354.14 56.88 7.5304 0.0003905 398.12


EMAP = (4*B)/(3*(D/t)) = (4*398.1196)/(3*56.88) = 9.3324 kgf/cm²

Cylindrical Shell From 30 to 40 Ext. Chart: CS-2 at 25 °C

Casco

Elastic Modulus from Chart: CS-2 at 25 °C : 0.204E+07 kgf/cm²

Results for Maximum Allowable External Pressure (MAEP):


Tca OD SLEN D/t L/D Factor A B
19.000 724.00 5354.14 38.11 7.3952 0.0008336 810.73
EMAP = (4*B)/(3*(D/t)) = (4*810.7336)/(3*38.1053) = 28.3682 kgf/cm²

Results for Maximum Stiffened Length (Slen):


Tca OD SLEN D/t L/D Factor A B
19.000 724.00 5354.14 38.11 7.3952 0.0008336 810.73
EMAP = (4*B)/(3*(D/t)) = (4*810.7336)/(3*38.1053) = 28.3682 kgf/cm²

Torispherical Head From 40 to 50 Ext. Chart: CS-2 at 25 °C

Elastic Modulus from Chart: CS-2 at 25 °C : 0.204E+07 kgf/cm²

Results for Maximum Allowable External Pressure (MAEP):


Tca Crown Rad Ro/t Factor A B
25.000 761.00 30.44 0.0041064 1191.74
EMAP = B/(Ro/t) = 1191.7421/30.44 = 39.1505 kgf/cm²

Results for Required Thickness (Tca):


Tca Crown Rad Ro/t Factor A B
2.189 761.00 347.60 0.0003596 366.61
EMAP = B/(Ro/t) = 366.6057/347.5981 = 1.0547 kgf/cm²

Check the requirements of UG-33(a)(1) using P = 1.67 * External Design


pressure for this head.

Material UNS Number: K02100

Inside Corroded Head Depth [h]:


= L - sqrt( ( L - Di / 2) * ( L + Di / 2 - 2 * r ) )
= 736.0-sqrt((736.0-686.0/2)*(736.0+686.0/2-2*44.16))
= 112.031 mm

M factor for Torispherical Head:


= (3+sqrt((L+C)/(r+C)))/4 per Appendix 1-4 (b & d)
= (3+sqrt((736.0+ 0.0)/(44.16+ 0.0)))/4
= 1.7706

Note: The knuckle radius r is less than 3 times the head thickness.
Please check UG-32(j) and UG-81 for Code compliance.

Required Thickness due to Internal Pressure [tr]:


= (P*L*M)/(2*S*E-0.2*P) per Appendix 1-4 (d)
= (1.761*736.0*1.7706)/(2*1202.25*1.0-0.2*1.761)
= 0.9547 + 0.0000 = 0.9547 mm

Max. Allowable Working Pressure at given Thickness, corroded [MAWP]:


= ((2*S*E*t)/(M*L+0.2*t))/1.67 per Appendix 1-4 (d)
= ((2*1202.25*1.0*25.0)/(1.7706*736.0+0.2*25.0))/1.67
= 27.516 kgf/cm²

Maximum Allowable External Pressure [MAEP]:


= min( MAEP, MAWP )
® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 15 of 20
External Pressure Calculations: Step: 5 12:17pm Oct 14,2022

= min( 39.15, 27.5158 )


= 27.516 kgf/cm²

Thickness requirements per UG-33(a)(1) do not govern the required


thickness of this head.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 16 of 20
Element and Detail Weights: Step: 6 12:17pm Oct 14,2022

Element and Detail Weights:

Element Element Corroded Corroded Extra due


From To Metal Wgt. ID Volume Metal Wgt. ID Volume Misc %
kg cm³ kg cm³ kg

10 20 280.363 ... 267.273 ... ...


20 30 162.846 283118 162.846 283118 ...
30 40 1467.67 1663223 1467.67 1663223 ...
40 50 115.66 44559.4 115.66 44559.4 ...

Total 2026 1990900.62 2013 1990900.62 0

Weight Summation Results: (kg)

Fabricated Shop Test Shipping Erected Empty Operating

Main Elements 2026.5 2026.5 2026.5 2026.5 2026.5 2026.5


Test Liquid ... 1990.0 ... ... ... ...

Totals 2026.5 4016.5 2026.5 2026.5 2026.5 2026.5

Weight Summary:

Fabricated Wt. - Bare Weight without Removable Internals 2026.5 kg


Shop Test Wt. - Fabricated Weight + Water ( Full ) 4016.5 kg
Shipping Wt. - Fab. Weight + removable Intls.+ Shipping App. 2026.5 kg
Erected Wt. - Fab. Wt + or - loose items (trays,platforms etc.) 2026.5 kg
Ope. Wt. no Liq - Fab. Weight + Internals. + Details + Weights 2026.5 kg
Operating Wt. - Empty Weight + Operating Liq. Uncorroded 2026.5 kg
Oper. Wt. + CA - Corr Wt. + Operating Liquid 2013.4 kg
Field Test Wt. - Empty Weight + Water (Full) 4016.5 kg

Note:
The Corroded Weight and thickness are used in the Horizontal
Vessel Analysis (Ope Case) and Earthquake Load Calculations.

Outside Surface Areas of Elements:

Surface
From To Area
cm²

10 20 ...
20 30 17109.9
30 40 102353
40 50 6097.64

Total 125560.648 cm²

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 17 of 20
Center of Gravity Calculation: Step: 7 12:17pm Oct 14,2022

Shop/Field Installation Options :

Note : The CG is computed from the first Element From Node

Center of Gravity of Bare Shell New and Cold 258.482 cm


Center of Gravity of Bare Shell Corroded 260.140 cm

Vessel CG in the Operating Condition 260.140 cm


Vessel CG in the Fabricated (Shop/Empty) Condition 258.482 cm

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 18 of 20
MDMT Summary: Step: 8 12:17pm Oct 14,2022

Minimum Design Metal Temperature Results Summary :

Curve Basic Reduced UG-20(f) Thickness Gov E* PWHT


Description MDMT MDMT MDMT ratio Thk reqd
Notes °C °C °C mm

Tampo Plano [12] C -31 -48 0.638 17.000 1.00 Yes


Carretel [8] C -38 -38 1.000 12.500 1.00 No
Casco [8] C -28 -47 0.658 19.000 1.00 No
[10] C -21 -25 0.933 25.000 1.00 No
[7] C -21 -48 0.500 25.000 1.00 No

Warmest MDMT: -21 -25

Required Minimum Design Metal Temperature 10.0 °C


Warmest Computed Minimum Design Metal Temperature -25.0 °C

Notes:
[ ! ] - This was an impact tested material.
[ 1] - Governing Nozzle Weld.
[ 4] - ANSI Flange MDMT Calcs; Thickness ratio per UCS-66(b)(1)(-c).
[ 5] - ANSI Flange MDMT Calcs; Thickness ratio per UCS-66(b)(1)(-b).
[ 6] - MDMT Calculations at the Shell/Head Joint.
[ 7] - MDMT Calculations for the Straight Flange.
[ 8] - Cylinder/Cone/Flange Junction MDMT.
[ 9] - Calculations in the Spherical Portion of the Head.
[10] - Calculations in the Knuckle Portion of the Head.
[11] - Calculated (Body Flange) Flange MDMT.
[12] - Calculated Flat Head MDMT per UCS-66.3
[13] - Tubesheet MDMT, shell side, if applicable
[14] - Tubesheet MDMT, tube side, if applicable
[15] - Nozzle Material
[16] - Shell or Head Material
[17] - Impact Testing required
[18] - Impact Testing not required, see UCS-66(b)(3)
[19] - Select a valid hydrotest type to get the UG-20(f) exemption
[20] - Cylinder/Cone Junction MDMT based on Longitudinal Stress considerations
[21] - Bolting Material

UG-84(b)(2) was not considered.


UCS-66(g) was not considered.
UCS-66(i) was not considered.

Notes:
Impact test temps were not entered in and not considered in the analysis.
UCS-66(i) applies to impact tested materials not by specification and
UCS-66(g) applies to materials impact tested per UG-84.1 General Note (c).
The Basic MDMT includes the (30F) PWHT credit if applicable.

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019


® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 19 of 20
Vessel Design Summary: Step: 9 12:17pm Oct 14,2022

ASME Code, Section VIII Division 1, 2017

Diameter Spec : 686.000 mm ID


Vessel Design Length, Tangent to Tangent 538.48 cm

Specified Datum Line Distance 0.00 cm

Internal Design Temperature 93 °C


Internal Design Pressure 7.031 kgf/cm²

External Design Temperature 93 °C


External Design Pressure 1.055 kgf/cm²

Maximum Allowable Working Pressure 42.876 kgf/cm²


External Max. Allowable Working Pressure 9.332 kgf/cm²
Hydrostatic Test Pressure 0.000 kgf/cm²

Required Minimum Design Metal Temperature 10.0 °C


Warmest Computed Minimum Design Metal Temperature -25.0 °C

Wind Design Code ASCE-93


Earthquake Design Code UBC-94

Materials of Construction:
Component Normal Impact
Type Material Class Thickness UNS # ized Tested

Shell SA-516 60 ... ... K02100 No No


Head SA-516 60 ... ... K02100 No No
Cover SA-516 60 ... ... K02100 No No

Normalized is determined based on the UCS-66 material curve selection and Figure UCS-66.
Impact Tested is based on material selection and material data properties.

Element Pressures and MAWP (kgf/cm² & mm):

Design Str. In
Element Description Pressure Ext. Element Corrosion Flg. Creep
or Type + Stat. head Press. M.A.W.P Allowance Gov. Range

Tampo Plano 35.400 0.00 105.397 3.1750 N/A No


Carretel 35.400 0.00 42.876 0.0000 N/A No
Casco 35.400 0.00 64.455 0.0000 N/A No
Torisph 35.400 1.05 45.951 0.0000 No No

Element Types and Properties:

Element "To" Elev Element Nominal Finished Reqd Thk Reqd Thk Long Circ
Length Thickness Thickness Internal External Eff Eff
Type cm cm mm mm mm mm

Wld Flat 6.8 6.8 68.0 68.0 40.7 ... 1.00 0.70
Cylinder 83.4 76.6 12.5 12.5 10.3 ... 1.00 1.00
Cylinder 533.4 450.0 19.0 19.0 10.3 ... 1.00 1.00
Torisph 538.5 5.1 25.0 25.0 19.2 2.2 1.00 1.00

Weights:
Fabricated - Bare W/O Removable Internals 2026.5 kg
Shop Test - Fabricated + Water ( Full ) 4016.5 kg
Shipping - Fab. + Rem. Intls.+ Shipping App. 2026.5 kg
Erected - Fab. + Rem. Intls.+ Insul. (etc) 2026.5 kg
Empty - Fab. + Intls. + Details + Wghts. 2026.5 kg
Operating - Empty + Operating Liquid (No CA) 2026.5 kg
® SPLM Licensed User
PV Elite 2019
PV Elite 2019 SP1 Licensee:
FileName : C-962 Page 20 of 20
Vessel Design Summary: Step: 9 12:17pm Oct 14,2022

Field Test - Empty Weight + Water (Full) 4016.5 kg

PV Elite is a trademark of Intergraph CADWorx & Analysis Solutions, Inc. 2019