You are on page 1of 84

SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.

DESIGN BY: NRK DATE : 05.03.19


CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-1 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 7.91 0.195 -0.173 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 0.892 -0.024 0.011 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.497 -0.015 0.572 = 1.68 t

WL-X
0.519 0.015 -0.622 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -0.407 -0.497 0.06
WL-Z 0.435 0.579 -0.059 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 17.12526 7.645205357 0.286272321 0.30994898 0.596221301 8.241426658 SAFE


2 DL+WL+X 15.73626 7.025116071 0.301339286 0.763392857 1.064732143 8.089848214 SAFE
3 DL+WL-X 16.75226 7.4786875 0.3515625 1.521045918 1.872608418 9.351295918 SAFE
4 DL+WL+Z 15.82626 7.065294643 0.505580357 0.21619898 0.721779337 7.78707398 SAFE
5 DL+WL-Z 16.66826 7.4411875 1.295758929 0.443877551 1.73963648 9.18082398 SAFE
6 DL+EQ+X 16.23326 7.246991071 0.326450893 0.330994898 0.657445791 7.904436862 SAFE
7 DL+EQ-X 16.23326 7.246991071 0.326450893 0.330994898 0.657445791 7.904436862 SAFE
8 DL+EQ+Z 16.23326 7.246991071 0.326450893 0.330994898 0.657445791 7.904436862 SAFE
9 DL+EQ-Z 16.23326 7.246991071 0.326450893 0.330994898 0.657445791 7.904436862 SAFE
10 DL+LL+WL+X 16.62826 7.423330357 0.261160714 0.784438776 1.04559949 8.468929847 SAFE
11 DL+LL+WL-X 17.64426 7.876901786 0.311383929 1.5 1.811383929 9.688285714 SAFE
12 DL+LL+WL+Z 16.71826 7.463508929 0.545758929 0.195153061 0.74091199 8.204420918 SAFE
13 DL+LL+WL-Z 17.56026 7.839401786 1.255580357 0.422831633 1.67841199 9.517813776 SAFE
14 DL+LL+EQ+X 17.12526 7.645205357 0.286272321 0.30994898 0.596221301 8.241426658 SAFE
15 DL+LL+EQ-X 17.12526 7.645205357 0.286272321 0.30994898 0.596221301 8.241426658 SAFE
16 DL+LL+EQ+Z 17.12526 7.645205357 0.286272321 0.30994898 0.596221301 8.241426658 SAFE
17 DL+LL+EQ-Z 17.12526 7.645205357 0.286272321 0.30994898 0.596221301 8.241426658 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.267 0.289 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.02 -0.04 F.O.S =1.66
WL+X -0.384 -0.009 WHERE,
WL-X 0.491 0.009 μ =COEFFICIENT OF FRICTION
WL+Z -0.049 -0.258 W= TOTAL VERTICAL LOAD
WL-Z 0.049 0.411 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.247 0.249 0.350727815 9.888823735 28.19515111 SAFE


2 DL+WL+X 0.117 0.28 0.303461694 9.086758472 29.94367539 SAFE
3 DL+WL-X 0.758 0.298 0.814474063 9.673438318 11.87691389 SAFE
4 DL+WL+Z 0.218 0.031 0.220193097 9.138728143 41.5032454 SAFE
5 DL+WL-Z 0.316 0.7 0.768020833 9.624933292 12.53212527 SAFE
6 DL+EQ+X 0.267 0.289 0.393459019 9.373746546 23.82394629 SAFE
7 DL+EQ-X 0.267 0.289 0.393459019 9.373746546 23.82394629 SAFE
8 DL+EQ+Z 0.267 0.289 0.393459019 9.373746546 23.82394629 SAFE
9 DL+EQ-Z 0.267 0.289 0.393459019 9.373746546 23.82394629 SAFE
10 DL+LL+WL+X 0.137 0.24 0.276349417 9.60183566 34.74527206 SAFE
11 DL+LL+WL-X 0.738 0.258 0.781797928 10.18851551 13.03215977 SAFE
12 DL+LL+WL+Z 0.198 0.009 0.19820444 9.653805331 48.70630212 SAFE
13 DL+LL+WL-Z 0.296 0.66 0.723336713 10.14001048 14.01838217 SAFE
14 DL+LL+EQ+X 0.247 0.249 0.350727815 9.888823735 28.19515111 SAFE
15 DL+LL+EQ-X 0.247 0.249 0.350727815 9.888823735 28.19515111 SAFE
16 DL+LL+EQ+Z 0.247 0.249 0.350727815 9.888823735 28.19515111 SAFE
17 DL+LL+EQ-Z 0.247 0.249 0.350727815 9.888823735 28.19515111 SAFE
Design Pressure, Pu = 6.385554847 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.023422692 t-m
Required footing depth,d req. = 78.00949802 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 193.8113894 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 3.888802902 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.159 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 18.98563384 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.382170799 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-2 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 9.751 -0.108 -0.165 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.374 0.018 0.017 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.614 -0.019 0.534 = 1.68 t

WL-X
0.641 0.019 -0.595 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -0.689 -0.735 0.016
WL-Z 0.661 0.711 -0.016 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 19.44826 8.682258929 0.150669643 0.283163265 0.433832908 9.116091837 SAFE


2 DL+WL+X 17.46026 7.794758929 0.212611607 0.705994898 0.918606505 8.713365434 SAFE
3 DL+WL-X 18.71526 8.355026786 0.148995536 1.454081633 1.603077168 9.958103954 SAFE
4 DL+WL+Z 17.38526 7.761276786 1.411272321 0.285076531 1.696348852 9.457625638 SAFE
5 DL+WL-Z 18.73526 8.363955357 1.009486607 0.34630102 1.355787628 9.719742985 SAFE
6 DL+EQ+X 18.07426 8.068866071 0.180803571 0.315688776 0.496492347 8.565358418 SAFE
7 DL+EQ-X 18.07426 8.068866071 0.180803571 0.315688776 0.496492347 8.565358418 SAFE
8 DL+EQ+Z 18.07426 8.068866071 0.180803571 0.315688776 0.496492347 8.565358418 SAFE
9 DL+EQ-Z 18.07426 8.068866071 0.180803571 0.315688776 0.496492347 8.565358418 SAFE
10 DL+LL+WL+X 18.83426 8.408151786 0.182477679 0.738520408 0.920998087 9.329149872 SAFE
11 DL+LL+WL-X 20.08926 8.968419643 0.118861607 1.421556122 1.54041773 10.50883737 SAFE
12 DL+LL+WL+Z 18.75926 8.374669643 1.381138393 0.25255102 1.633689413 10.00835906 SAFE
13 DL+LL+WL-Z 20.10926 8.977348214 1.039620536 0.31377551 1.353396046 10.33074426 SAFE
14 DL+LL+EQ+X 19.44826 8.682258929 0.150669643 0.283163265 0.433832908 9.116091837 SAFE
15 DL+LL+EQ-X 19.44826 8.682258929 0.150669643 0.283163265 0.433832908 9.116091837 SAFE
16 DL+LL+EQ+Z 19.44826 8.682258929 0.150669643 0.283163265 0.433832908 9.116091837 SAFE
17 DL+LL+EQ-Z 19.44826 8.682258929 0.150669643 0.283163265 0.433832908 9.116091837 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.255 -0.176 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.03 0.027 F.O.S =1.66
WL+X -0.306 -0.016 WHERE,
WL-X 0.445 0.015 μ =COEFFICIENT OF FRICTION
WL+Z -0.011 -0.644 W= TOTAL VERTICAL LOAD
WL-Z 0.012 0.611 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.225 0.149 0.269862928 11.2302187 41.61452918 SAFE


2 DL+WL+X 0.051 0.192 0.198657998 10.0822664 50.75187772 SAFE
3 DL+WL-X 0.7 0.161 0.718276409 10.8069546 15.04567665 SAFE
4 DL+WL+Z 0.244 0.82 0.855532583 10.03895834 11.73416249 SAFE
5 DL+WL-Z 0.267 0.435 0.510405721 10.81850341 21.1958898 SAFE
6 DL+EQ+X 0.255 0.176 0.309840281 10.43681505 33.68450028 SAFE
7 DL+EQ-X 0.255 0.176 0.309840281 10.43681505 33.68450028 SAFE
8 DL+EQ+Z 0.255 0.176 0.309840281 10.43681505 33.68450028 SAFE
9 DL+EQ-Z 0.255 0.176 0.309840281 10.43681505 33.68450028 SAFE
10 DL+LL+WL+X 0.081 0.165 0.183809684 10.87567005 59.16810151 SAFE
11 DL+LL+WL-X 0.67 0.134 0.683268615 11.60035825 16.97774198 SAFE
12 DL+LL+WL+Z 0.214 0.793 0.821367762 10.83236199 13.18819961 SAFE
13 DL+LL+WL-Z 0.237 0.462 0.519242718 11.61190706 22.36315824 SAFE
14 DL+LL+EQ+X 0.225 0.149 0.269862928 11.2302187 41.61452918 SAFE
15 DL+LL+EQ-X 0.225 0.149 0.269862928 11.2302187 41.61452918 SAFE
16 DL+LL+EQ+Z 0.225 0.149 0.269862928 11.2302187 41.61452918 SAFE
17 DL+LL+EQ-Z 0.225 0.149 0.269862928 11.2302187 41.61452918 SAFE
Design Pressure, Pu = 6.992362883 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.215704988 t-m
Required footing depth,d req. = 81.63194474 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 212.5608909 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 4.258348996 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.175 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 20.7898052 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.418487818 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-4 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 9.69 0.131 -0.157 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.375 -0.018 0.017 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.583 -0.019 0.531 = 1.68 t

WL-X
0.609 0.019 -0.593 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 0.649 -0.711 -0.007
WL-Z -0.677 0.735 0.007 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 19.38826 8.655473214 0.189174107 0.267857143 0.45703125 9.112504464 SAFE


2 DL+WL+X 17.43026 7.781366071 0.1875 0.715561224 0.903061224 8.684427296 SAFE
3 DL+WL-X 18.62226 8.313508929 0.251116071 1.43494898 1.686065051 9.99957398 SAFE
4 DL+WL+Z 18.66226 8.331366071 0.970982143 0.31377551 1.284757653 9.616123724 SAFE
5 DL+WL-Z 17.33626 7.739401786 1.449776786 0.286989796 1.736766582 9.476168367 SAFE
6 DL+EQ+X 18.01326 8.041633929 0.219308036 0.300382653 0.519690689 8.561324617 SAFE
7 DL+EQ-X 18.01326 8.041633929 0.219308036 0.300382653 0.519690689 8.561324617 SAFE
8 DL+EQ+Z 18.01326 8.041633929 0.219308036 0.300382653 0.519690689 8.561324617 SAFE
9 DL+EQ-Z 18.01326 8.041633929 0.219308036 0.300382653 0.519690689 8.561324617 SAFE
10 DL+LL+WL+X 18.80526 8.395205357 0.157366071 0.748086735 0.905452806 9.300658163 SAFE
11 DL+LL+WL-X 19.99726 8.927348214 0.220982143 1.402423469 1.623405612 10.55075383 SAFE
12 DL+LL+WL+Z 20.03726 8.945205357 1.001116071 0.28125 1.282366071 10.22757143 SAFE
13 DL+LL+WL-Z 18.71126 8.353241071 1.419642857 0.254464286 1.674107143 10.02734821 SAFE
14 DL+LL+EQ+X 19.38826 8.655473214 0.189174107 0.267857143 0.45703125 9.112504464 SAFE
15 DL+LL+EQ-X 19.38826 8.655473214 0.189174107 0.267857143 0.45703125 9.112504464 SAFE
16 DL+LL+EQ+Z 19.38826 8.655473214 0.189174107 0.267857143 0.45703125 9.112504464 SAFE
17 DL+LL+EQ-Z 19.38826 8.655473214 0.189174107 0.267857143 0.45703125 9.112504464 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.241 0.195 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.03 -0.027 F.O.S =1.66
WL+X -0.301 -0.015 WHERE,
WL-X 0.441 0.015 μ =COEFFICIENT OF FRICTION
WL+Z 0.006 -0.611 W= TOTAL VERTICAL LOAD
WL-Z -0.005 0.644 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.211 0.168 0.26971281 11.19557225 41.50923437 SAFE


2 DL+WL+X 0.06 0.18 0.18973666 10.06494318 53.04690827 SAFE
3 DL+WL-X 0.682 0.21 0.713599327 10.7532526 15.06903411 SAFE
4 DL+WL+Z 0.247 0.416 0.483802646 10.77635024 22.27426892 SAFE
5 DL+WL-Z 0.236 0.839 0.871560095 10.01066374 11.48591336 SAFE
6 DL+EQ+X 0.241 0.195 0.310009677 10.40159116 33.55247246 SAFE
7 DL+EQ-X 0.241 0.195 0.310009677 10.40159116 33.55247246 SAFE
8 DL+EQ+Z 0.241 0.195 0.310009677 10.40159116 33.55247246 SAFE
9 DL+EQ-Z 0.241 0.195 0.310009677 10.40159116 33.55247246 SAFE
10 DL+LL+WL+X 0.09 0.153 0.177507746 10.85892427 61.17436841 SAFE
11 DL+LL+WL-X 0.652 0.183 0.67719495 11.5472337 17.05156499 SAFE
12 DL+LL+WL+Z 0.217 0.443 0.493293016 11.57033133 23.45529116 SAFE
13 DL+LL+WL-Z 0.206 0.812 0.837723105 10.80464483 12.89763261 SAFE
14 DL+LL+EQ+X 0.211 0.168 0.26971281 11.19557225 41.50923437 SAFE
15 DL+LL+EQ-X 0.211 0.168 0.26971281 11.19557225 41.50923437 SAFE
16 DL+LL+EQ+Z 0.211 0.168 0.26971281 11.19557225 41.50923437 SAFE
17 DL+LL+EQ-Z 0.211 0.168 0.26971281 11.19557225 41.50923437 SAFE
Design Pressure, Pu = 7.033832908 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.228845803 t-m
Required footing depth,d req. = 81.87365661 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 213.8444357 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 4.283604241 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.176 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 20.91310454 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.420969768 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-4 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 7.9 -0.177 -0.173 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 0.893 0.024 0.012 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.578 -0.015 0.513 = 1.68 t

WL-X
0.601 0.014 -0.561 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 0.461 -0.579 -0.068
WL-Z -0.433 0.496 0.068 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 17.11626 7.6411875 0.256138393 0.308035714 0.564174107 8.205361607 SAFE


2 DL+WL+X 15.64526 6.984491071 0.321428571 0.650510204 0.971938776 7.956429847 SAFE
3 DL+WL-X 16.82426 7.510830357 0.272879464 1.404336735 1.677216199 9.188046556 SAFE
4 DL+WL+Z 16.68426 7.448330357 1.265625 0.461096939 1.726721939 9.175052296 SAFE
5 DL+WL-Z 15.79026 7.049223214 0.534040179 0.200892857 0.734933036 7.78415625 SAFE
6 DL+EQ+X 16.22326 7.242526786 0.296316964 0.330994898 0.627311862 7.869838648 SAFE
7 DL+EQ-X 16.22326 7.242526786 0.296316964 0.330994898 0.627311862 7.869838648 SAFE
8 DL+EQ+Z 16.22326 7.242526786 0.296316964 0.330994898 0.627311862 7.869838648 SAFE
9 DL+EQ-Z 16.22326 7.242526786 0.296316964 0.330994898 0.627311862 7.869838648 SAFE
10 DL+LL+WL+X 16.53826 7.383151786 0.28125 0.673469388 0.954719388 8.337871173 SAFE
11 DL+LL+WL-X 17.71726 7.909491071 0.232700893 1.381377551 1.614078444 9.523569515 SAFE
12 DL+LL+WL+Z 17.57726 7.846991071 1.225446429 0.438137755 1.663584184 9.510575255 SAFE
13 DL+LL+WL-Z 16.68326 7.447883929 0.57421875 0.177933673 0.752152423 8.200036352 SAFE
14 DL+LL+EQ+X 17.11626 7.6411875 0.256138393 0.308035714 0.564174107 8.205361607 SAFE
15 DL+LL+EQ-X 17.11626 7.6411875 0.256138393 0.308035714 0.564174107 8.205361607 SAFE
16 DL+LL+EQ+Z 17.11626 7.6411875 0.256138393 0.308035714 0.564174107 8.205361607 SAFE
17 DL+LL+EQ-Z 17.11626 7.6411875 0.256138393 0.308035714 0.564174107 8.205361607 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.263 -0.278 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.021 0.04 F.O.S =1.66
WL+X -0.309 -0.009 WHERE,
WL-X 0.414 0.009 μ =COEFFICIENT OF FRICTION
WL+Z 0.053 -0.411 W= TOTAL VERTICAL LOAD
WL-Z -0.053 0.258 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.242 0.238 0.33942304 9.883626767 29.11890357 SAFE


2 DL+WL+X 0.046 0.287 0.290663035 9.034211359 31.08139071 SAFE
3 DL+WL-X 0.677 0.269 0.728484729 9.715014056 13.33591999 SAFE
4 DL+WL+Z 0.316 0.689 0.758008575 9.634172344 12.70984612 SAFE
5 DL+WL-Z 0.21 0.02 0.210950231 9.117940274 43.2231822 SAFE
6 DL+EQ+X 0.263 0.278 0.382691782 9.367972138 24.4791568 SAFE
7 DL+EQ-X 0.263 0.278 0.382691782 9.367972138 24.4791568 SAFE
8 DL+EQ+Z 0.263 0.278 0.382691782 9.367972138 24.4791568 SAFE
9 DL+EQ-Z 0.263 0.278 0.382691782 9.367972138 24.4791568 SAFE
10 DL+LL+WL+X 0.067 0.247 0.25592577 9.549865988 37.31498383 SAFE
11 DL+LL+WL-X 0.656 0.229 0.69482156 10.23066868 14.724167 SAFE
12 DL+LL+WL+Z 0.295 0.649 0.712899712 10.14982697 14.23738402 SAFE
13 DL+LL+WL-Z 0.189 0.02 0.190055255 9.633594904 50.68839005 SAFE
14 DL+LL+EQ+X 0.242 0.238 0.33942304 9.883626767 29.11890357 SAFE
15 DL+LL+EQ-X 0.242 0.238 0.33942304 9.883626767 29.11890357 SAFE
16 DL+LL+EQ+Z 0.242 0.238 0.33942304 9.883626767 29.11890357 SAFE
17 DL+LL+EQ-Z 0.242 0.238 0.33942304 9.883626767 29.11890357 SAFE
Design Pressure, Pu = 6.222305485 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 1.97169305 t-m
Required footing depth,d req. = 77.00586933 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 188.7773691 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 3.78938404 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.155 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 18.50025822 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.372400444 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-5 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 12.64 0.202 0.027 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.003 -0.041 -0.009 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.094 -0.001 0.77 = 1.68 t

WL-X
-0.123 0.002 -0.72 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -0.53 -0.779 0.068
WL-Z 0.579 0.929 -0.067 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 22.96626 10.25279464 0.26953125 0.034438776 0.303970026 10.55676467 SAFE


2 DL+WL+X 21.05726 9.4005625 0.336495536 1.524872449 1.861367985 11.26193048 SAFE
3 DL+WL-X 20.84026 9.3036875 0.341517857 1.325892857 1.667410714 10.97109821 SAFE
4 DL+WL+Z 20.43326 9.121991071 0.965959821 0.181760204 1.147720026 10.2697111 SAFE
5 DL+WL-Z 21.54226 9.617080357 1.893415179 0.076530612 1.969945791 11.58702615 SAFE
6 DL+EQ+X 20.96326 9.358598214 0.338169643 0.051658163 0.389827806 9.74842602 SAFE
7 DL+EQ-X 20.96326 9.358598214 0.338169643 0.051658163 0.389827806 9.74842602 SAFE
8 DL+EQ+Z 20.96326 9.358598214 0.338169643 0.051658163 0.389827806 9.74842602 SAFE
9 DL+EQ-Z 20.96326 9.358598214 0.338169643 0.051658163 0.389827806 9.74842602 SAFE
10 DL+LL+WL+X 23.06026 10.29475893 0.267857143 1.507653061 1.775510204 12.07026913 SAFE
11 DL+LL+WL-X 22.84326 10.19788393 0.272879464 1.343112245 1.615991709 11.81387564 SAFE
12 DL+LL+WL+Z 22.43626 10.0161875 1.034598214 0.164540816 1.199139031 11.21532653 SAFE
13 DL+LL+WL-Z 23.54526 10.51127679 1.824776786 0.09375 1.918526786 12.42980357 SAFE
14 DL+LL+EQ+X 22.96626 10.25279464 0.26953125 0.034438776 0.303970026 10.55676467 SAFE
15 DL+LL+EQ-X 22.96626 10.25279464 0.26953125 0.034438776 0.303970026 10.55676467 SAFE
16 DL+LL+EQ+Z 22.96626 10.25279464 0.26953125 0.034438776 0.303970026 10.55676467 SAFE
17 DL+LL+EQ-Z 22.96626 10.25279464 0.26953125 0.034438776 0.303970026 10.55676467 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.038 0.285 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.013 -0.07 F.O.S =1.66
WL+X -0.695 0 WHERE,
WL-X 0.638 0.001 μ =COEFFICIENT OF FRICTION
WL+Z -0.061 -0.395 W= TOTAL VERTICAL LOAD
WL-Z 0.061 0.678 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.025 0.215 0.216448608 13.26165541 61.26930324 SAFE


2 DL+WL+X 0.733 0.285 0.78645661 12.15932094 15.46089228 SAFE
3 DL+WL-X 0.6 0.286 0.664677365 12.03401628 18.10504902 SAFE
4 DL+WL+Z 0.099 0.11 0.147989865 11.79899788 79.7284187 SAFE
5 DL+WL-Z 0.023 0.963 0.963274623 12.43937972 12.91363794 SAFE
6 DL+EQ+X 0.038 0.285 0.287522173 12.1050415 42.10124518 SAFE
7 DL+EQ-X 0.038 0.285 0.287522173 12.1050415 42.10124518 SAFE
8 DL+EQ+Z 0.038 0.285 0.287522173 12.1050415 42.10124518 SAFE
9 DL+EQ-Z 0.038 0.285 0.287522173 12.1050415 42.10124518 SAFE
10 DL+LL+WL+X 0.72 0.215 0.751415331 13.31593485 17.72113809 SAFE
11 DL+LL+WL-X 0.613 0.216 0.649942305 13.1906302 20.29507864 SAFE
12 DL+LL+WL+Z 0.086 0.18 0.199489348 12.95561179 64.94387754 SAFE
13 DL+LL+WL-Z 0.036 0.893 0.893725349 13.59599363 15.21272015 SAFE
14 DL+LL+EQ+X 0.025 0.215 0.216448608 13.26165541 61.26930324 SAFE
15 DL+LL+EQ-X 0.025 0.215 0.216448608 13.26165541 61.26930324 SAFE
16 DL+LL+EQ+Z 0.025 0.215 0.216448608 13.26165541 61.26930324 SAFE
17 DL+LL+EQ-Z 0.025 0.215 0.216448608 13.26165541 61.26930324 SAFE
Design Pressure, Pu = 8.621285077 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.731869709 t-m
Required footing depth,d req. = 90.64297821 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 263.1900977 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.250362612 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.215 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 25.63294273 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.515977623 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-6 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 13.774 -0.108 0.028 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 3.073 0.032 -0.013 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.1 -0.002 0.776 = 1.68 t

WL-X
-0.133 0.003 -0.703 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -1.006 -1.175 0.018
WL-Z 0.957 1.13 -0.018 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 25.17026 11.23672321 0.127232143 0.02869898 0.155931122 11.39265434 SAFE


2 DL+WL+X 22.19726 9.909491071 0.184151786 1.538265306 1.722417092 11.63190816 SAFE
3 DL+WL-X 21.96426 9.805473214 0.17578125 1.291454082 1.467235332 11.27270855 SAFE
4 DL+WL+Z 21.09126 9.415741071 2.147879464 0.088010204 2.235889668 11.65163074 SAFE
5 DL+WL-Z 23.05426 10.29208036 1.7109375 0.019132653 1.730070153 12.02215051 SAFE
6 DL+EQ+X 22.09726 9.864848214 0.180803571 0.053571429 0.234375 10.09922321 SAFE
7 DL+EQ-X 22.09726 9.864848214 0.180803571 0.053571429 0.234375 10.09922321 SAFE
8 DL+EQ+Z 22.09726 9.864848214 0.180803571 0.053571429 0.234375 10.09922321 SAFE
9 DL+EQ-Z 22.09726 9.864848214 0.180803571 0.053571429 0.234375 10.09922321 SAFE
10 DL+LL+WL+X 25.27026 11.28136607 0.130580357 1.513392857 1.643973214 12.92533929 SAFE
11 DL+LL+WL-X 25.03726 11.17734821 0.122209821 1.316326531 1.438536352 12.61588457 SAFE
12 DL+LL+WL+Z 24.16426 10.78761607 2.094308036 0.063137755 2.157445791 12.94506186 SAFE
13 DL+LL+WL-Z 26.12726 11.66395536 1.764508929 0.005739796 1.770248724 13.43420408 SAFE
14 DL+LL+EQ+X 25.17026 11.23672321 0.127232143 0.02869898 0.155931122 11.39265434 SAFE
15 DL+LL+EQ-X 25.17026 11.23672321 0.127232143 0.02869898 0.155931122 11.39265434 SAFE
16 DL+LL+EQ+Z 25.17026 11.23672321 0.127232143 0.02869898 0.155931122 11.39265434 SAFE
17 DL+LL+EQ-Z 25.17026 11.23672321 0.127232143 0.02869898 0.155931122 11.39265434 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.038 -0.19 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.017 0.049 F.O.S =1.66
WL+X -0.691 -0.001 WHERE,
WL-X 0.608 0.002 μ =COEFFICIENT OF FRICTION
WL+Z -0.015 -1.039 W= TOTAL VERTICAL LOAD
WL-Z 0.015 0.978 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.021 0.141 0.142555252 14.53433492 101.9558008 SAFE


2 DL+WL+X 0.729 0.191 0.753605998 12.81760344 17.00836177 SAFE
3 DL+WL-X 0.57 0.188 0.600203299 12.68305974 21.13127296 SAFE
4 DL+WL+Z 0.053 1.229 1.230142268 12.17895392 9.90044342 SAFE
5 DL+WL-Z 0.023 0.788 0.788335588 13.3124702 16.88680607 SAFE
6 DL+EQ+X 0.038 0.19 0.193762742 12.75985936 65.85300798 SAFE
7 DL+EQ-X 0.038 0.19 0.193762742 12.75985936 65.85300798 SAFE
8 DL+EQ+Z 0.038 0.19 0.193762742 12.75985936 65.85300798 SAFE
9 DL+EQ-Z 0.038 0.19 0.193762742 12.75985936 65.85300798 SAFE
10 DL+LL+WL+X 0.712 0.142 0.726022038 14.592079 20.09867226 SAFE
11 DL+LL+WL-X 0.587 0.139 0.603232957 14.4575353 23.96675304 SAFE
12 DL+LL+WL+Z 0.036 1.18 1.180549025 13.95342948 11.81944095 SAFE
13 DL+LL+WL-Z 0.006 0.837 0.837021505 15.08694576 18.0245617 SAFE
14 DL+LL+EQ+X 0.021 0.141 0.142555252 14.53433492 101.9558008 SAFE
15 DL+LL+EQ-X 0.021 0.141 0.142555252 14.53433492 101.9558008 SAFE
16 DL+LL+EQ+Z 0.021 0.141 0.142555252 14.53433492 101.9558008 SAFE
17 DL+LL+EQ-Z 0.021 0.141 0.142555252 14.53433492 101.9558008 SAFE
Design Pressure, Pu = 9.056409439 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.869749741 t-m
Required footing depth,d req. = 92.90224049 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 276.7888757 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.515353348 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.226 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 26.92666145 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.542019498 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-7 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 13.544 0.136 -0.04 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 3.069 -0.032 -0.013 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.108 -0.001 0.776 = 1.68 t

WL-X
-0.141 0.003 -0.703 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 0.96 -1.13 -0.008
WL-Z -1.009 1.176 0.008 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 24.93626 11.13225893 0.174107143 0.101403061 0.275510204 11.40776913 SAFE


2 DL+WL+X 21.97526 9.810383929 0.226004464 1.408163265 1.63416773 11.44455166 SAFE
3 DL+WL-X 21.72626 9.699223214 0.232700893 1.421556122 1.654257015 11.35348023 SAFE
4 DL+WL+Z 22.82726 10.19074107 1.6640625 0.091836735 1.755899235 11.94664031 SAFE
5 DL+WL-Z 20.85826 9.311723214 2.196428571 0.06122449 2.257653061 11.56937628 SAFE
6 DL+EQ+X 21.86726 9.762169643 0.227678571 0.076530612 0.304209184 10.06637883 SAFE
7 DL+EQ-X 21.86726 9.762169643 0.227678571 0.076530612 0.304209184 10.06637883 SAFE
8 DL+EQ+Z 21.86726 9.762169643 0.227678571 0.076530612 0.304209184 10.06637883 SAFE
9 DL+EQ-Z 21.86726 9.762169643 0.227678571 0.076530612 0.304209184 10.06637883 SAFE
10 DL+LL+WL+X 25.04426 11.18047321 0.172433036 1.383290816 1.555723852 12.73619707 SAFE
11 DL+LL+WL-X 24.79526 11.0693125 0.179129464 1.446428571 1.625558036 12.69487054 SAFE
12 DL+LL+WL+Z 25.89626 11.56083036 1.717633929 0.116709184 1.834343112 13.39517347 SAFE
13 DL+LL+WL-Z 23.92726 10.6818125 2.142857143 0.086096939 2.228954082 12.91076658 SAFE
14 DL+LL+EQ+X 24.93626 11.13225893 0.174107143 0.101403061 0.275510204 11.40776913 SAFE
15 DL+LL+EQ-X 24.93626 11.13225893 0.174107143 0.101403061 0.275510204 11.40776913 SAFE
16 DL+LL+EQ+Z 24.93626 11.13225893 0.174107143 0.101403061 0.275510204 11.40776913 SAFE
17 DL+LL+EQ-Z 24.93626 11.13225893 0.174107143 0.101403061 0.275510204 11.40776913 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.064 0.189 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.018 -0.049 F.O.S =1.66
WL+X -0.69 -0.001 WHERE,
WL-X 0.607 0.002 μ =COEFFICIENT OF FRICTION
WL+Z 0.008 -0.979 W= TOTAL VERTICAL LOAD
WL-Z -0.007 1.04 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.082 0.14 0.162246726 14.39921378 88.7488713 SAFE


2 DL+WL+X 0.626 0.188 0.653620685 12.68941159 19.41403 SAFE
3 DL+WL-X 0.671 0.191 0.697654642 12.54562883 17.98257772 SAFE
4 DL+WL+Z 0.072 0.79 0.793274227 13.18139114 16.6164369 SAFE
5 DL+WL-Z 0.057 1.229 1.230321096 12.04441022 9.789647805 SAFE
6 DL+EQ+X 0.064 0.189 0.199541976 12.62704798 63.28015921 SAFE
7 DL+EQ-X 0.064 0.189 0.199541976 12.62704798 63.28015921 SAFE
8 DL+EQ+Z 0.064 0.189 0.199541976 12.62704798 63.28015921 SAFE
9 DL+EQ-Z 0.064 0.189 0.199541976 12.62704798 63.28015921 SAFE
10 DL+LL+WL+X 0.608 0.139 0.62368662 14.46157738 23.18724968 SAFE
11 DL+LL+WL-X 0.689 0.142 0.703480632 14.31779463 20.35279149 SAFE
12 DL+LL+WL+Z 0.09 0.839 0.843813368 14.95355694 17.72140322 SAFE
13 DL+LL+WL-Z 0.075 1.18 1.182381072 13.81657602 11.68538328 SAFE
14 DL+LL+EQ+X 0.082 0.14 0.162246726 14.39921378 88.7488713 SAFE
15 DL+LL+EQ-X 0.082 0.14 0.162246726 14.39921378 88.7488713 SAFE
16 DL+LL+EQ+Z 0.082 0.14 0.162246726 14.39921378 88.7488713 SAFE
17 DL+LL+EQ-Z 0.082 0.14 0.162246726 14.39921378 88.7488713 SAFE
Design Pressure, Pu = 8.980899235 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.845822445 t-m
Required footing depth,d req. = 92.51413133 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 274.4267073 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.469367634 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.224 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 26.7021533 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.537500268 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-8 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 13.241 -0.183 0.009 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.997 0.041 -0.009 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.125 -0.001 0.719 = 1.68 t

WL-X
-0.152 0.003 -0.666 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 0.574 -0.929 -0.079
WL-Z -0.525 0.779 0.079 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 23.56126 10.51841964 0.237723214 0 0.237723214 10.75614286 SAFE


2 DL+WL+X 21.68926 9.682705357 0.308035714 1.392857143 1.700892857 11.38359821 SAFE
3 DL+WL-X 21.41226 9.559044643 0.301339286 1.257015306 1.558354592 11.11739923 SAFE
4 DL+WL+Z 22.13826 9.883151786 1.861607143 0.133928571 1.995535714 11.8786875 SAFE
5 DL+WL-Z 21.03926 9.392526786 0.997767857 0.168367347 1.166135204 10.55866199 SAFE
6 DL+EQ+X 21.56426 9.626901786 0.306361607 0.017219388 0.323580995 9.950482781 SAFE
7 DL+EQ-X 21.56426 9.626901786 0.306361607 0.017219388 0.323580995 9.950482781 SAFE
8 DL+EQ+Z 21.56426 9.626901786 0.306361607 0.017219388 0.323580995 9.950482781 SAFE
9 DL+EQ-Z 21.56426 9.626901786 0.306361607 0.017219388 0.323580995 9.950482781 SAFE
10 DL+LL+WL+X 23.68626 10.57422321 0.239397321 1.375637755 1.615035077 12.18925829 SAFE
11 DL+LL+WL-X 23.40926 10.4505625 0.232700893 1.274234694 1.506935587 11.95749809 SAFE
12 DL+LL+WL+Z 24.13526 10.77466964 1.79296875 0.151147959 1.944116709 12.71878635 SAFE
13 DL+LL+WL-Z 23.03626 10.28404464 1.06640625 0.151147959 1.217554209 11.50159885 SAFE
14 DL+LL+EQ+X 23.56126 10.51841964 0.237723214 0 0.237723214 10.75614286 SAFE
15 DL+LL+EQ-X 23.56126 10.51841964 0.237723214 0 0.237723214 10.75614286 SAFE
16 DL+LL+EQ+Z 23.56126 10.51841964 0.237723214 0 0.237723214 10.75614286 SAFE
17 DL+LL+EQ-Z 23.56126 10.51841964 0.237723214 0 0.237723214 10.75614286 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.014 -0.299 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.012 0.07 F.O.S =1.66
WL+X -0.633 0 WHERE,
WL-X 0.574 0.001 μ =COEFFICIENT OF FRICTION
WL+Z 0.069 -0.678 W= TOTAL VERTICAL LOAD
WL-Z -0.069 0.395 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.002 0.229 0.229008733 13.60523269 59.40923073 SAFE


2 DL+WL+X 0.647 0.299 0.712748202 12.52426352 17.5717925 SAFE
3 DL+WL-X 0.56 0.298 0.634353214 12.36431242 19.49121112 SAFE
4 DL+WL+Z 0.055 0.977 0.978546882 12.78353444 13.06379354 SAFE
5 DL+WL-Z 0.083 0.096 0.126905477 12.148927 95.73209388 SAFE
6 DL+EQ+X 0.014 0.299 0.29932758 12.45208342 41.60018743 SAFE
7 DL+EQ-X 0.014 0.299 0.29932758 12.45208342 41.60018743 SAFE
8 DL+EQ+Z 0.014 0.299 0.29932758 12.45208342 41.60018743 SAFE
9 DL+EQ-Z 0.014 0.299 0.29932758 12.45208342 41.60018743 SAFE
10 DL+LL+WL+X 0.635 0.229 0.67503037 13.67741279 20.26192213 SAFE
11 DL+LL+WL-X 0.572 0.228 0.615766189 13.51746169 21.95226357 SAFE
12 DL+LL+WL+Z 0.067 0.907 0.909471275 13.9366837 15.3239405 SAFE
13 DL+LL+WL-Z 0.071 0.166 0.180546393 13.30207627 73.67677666 SAFE
14 DL+LL+EQ+X 0.002 0.229 0.229008733 13.60523269 59.40923073 SAFE
15 DL+LL+EQ-X 0.002 0.229 0.229008733 13.60523269 59.40923073 SAFE
16 DL+LL+EQ+Z 0.002 0.229 0.229008733 13.60523269 59.40923073 SAFE
17 DL+LL+EQ-Z 0.002 0.229 0.229008733 13.60523269 59.40923073 SAFE
Design Pressure, Pu = 8.912946429 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.8242899 t-m
Required footing depth,d req. = 92.16346869 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 272.3017738 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.427984375 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.222 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 26.50011493 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.533433342 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-9 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 13.566 0.277 -0.094 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.927 -0.041 -0.001 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.186 -0.007 0.747 = 1.68 t

WL-X
0.166 0.007 -0.738 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -0.778 -1.008 0.067
WL-Z 0.822 1.161 -0.067 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 23.81626 10.63225893 0.395089286 0.181760204 0.57684949 11.20910842 SAFE


2 DL+WL+X 21.70326 9.688955357 0.452008929 1.249362245 1.701371173 11.39032653 SAFE
3 DL+WL-X 22.05526 9.846098214 0.475446429 1.591836735 2.067283163 11.91338138 SAFE
4 DL+WL+Z 21.11126 9.424669643 1.223772321 0.051658163 1.275430485 10.70010013 SAFE
5 DL+WL-Z 22.71126 10.13895536 2.407366071 0.308035714 2.715401786 12.85435714 SAFE
6 DL+EQ+X 21.88926 9.771991071 0.463727679 0.179846939 0.643574617 10.41556569 SAFE
7 DL+EQ-X 21.88926 9.771991071 0.463727679 0.179846939 0.643574617 10.41556569 SAFE
8 DL+EQ+Z 21.88926 9.771991071 0.463727679 0.179846939 0.643574617 10.41556569 SAFE
9 DL+EQ-Z 21.88926 9.771991071 0.463727679 0.179846939 0.643574617 10.41556569 SAFE
10 DL+LL+WL+X 23.63026 10.54922321 0.383370536 1.24744898 1.630819515 12.18004273 SAFE
11 DL+LL+WL-X 23.98226 10.70636607 0.406808036 1.59375 2.000558036 12.70692411 SAFE
12 DL+LL+WL+Z 23.03826 10.2849375 1.292410714 0.053571429 1.345982143 11.63091964 SAFE
13 DL+LL+WL-Z 24.63826 10.99922321 2.338727679 0.30994898 2.648676658 13.64789987 SAFE
14 DL+LL+EQ+X 23.81626 10.63225893 0.395089286 0.181760204 0.57684949 11.20910842 SAFE
15 DL+LL+EQ-X 23.81626 10.63225893 0.395089286 0.181760204 0.57684949 11.20910842 SAFE
16 DL+LL+EQ+Z 23.81626 10.63225893 0.395089286 0.181760204 0.57684949 11.20910842 SAFE
17 DL+LL+EQ-Z 23.81626 10.63225893 0.395089286 0.181760204 0.57684949 11.20910842 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.149 0.402 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.001 -0.07 F.O.S =1.66
WL+X -0.663 -0.005 WHERE,
WL-X 0.657 0.005 μ =COEFFICIENT OF FRICTION
WL+Z -0.06 -0.543 W= TOTAL VERTICAL LOAD
WL-Z 0.061 0.83 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.15 0.332 0.364313052 13.75248009 37.74907324 SAFE


2 DL+WL+X 0.514 0.397 0.649465165 12.53234769 19.29641245 SAFE
3 DL+WL-X 0.806 0.407 0.902931337 12.73560685 14.10473457 SAFE
4 DL+WL+Z 0.089 0.141 0.166739317 12.19050274 73.11114693 SAFE
5 DL+WL-Z 0.21 1.232 1.249769579 13.11440801 10.49346074 SAFE
6 DL+EQ+X 0.149 0.402 0.428724853 12.63975168 29.48219954 SAFE
7 DL+EQ-X 0.149 0.402 0.428724853 12.63975168 29.48219954 SAFE
8 DL+EQ+Z 0.149 0.402 0.428724853 12.63975168 29.48219954 SAFE
9 DL+EQ-Z 0.149 0.402 0.428724853 12.63975168 29.48219954 SAFE
10 DL+LL+WL+X 0.513 0.327 0.608356803 13.6450761 22.42939674 SAFE
11 DL+LL+WL-X 0.807 0.337 0.874538736 13.84833526 15.83501645 SAFE
12 DL+LL+WL+Z 0.09 0.211 0.229392676 13.30323115 57.99326882 SAFE
13 DL+LL+WL-Z 0.211 1.162 1.181001693 14.22713642 12.04666894 SAFE
14 DL+LL+EQ+X 0.15 0.332 0.364313052 13.75248009 37.74907324 SAFE
15 DL+LL+EQ-X 0.15 0.332 0.364313052 13.75248009 37.74907324 SAFE
16 DL+LL+EQ+Z 0.15 0.332 0.364313052 13.75248009 37.74907324 SAFE
17 DL+LL+EQ-Z 0.15 0.332 0.364313052 13.75248009 37.74907324 SAFE
Design Pressure, Pu = 9.888616071 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 3.133455218 t-m
Required footing depth,d req. = 97.07690491 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 302.8863648 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 6.022167188 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.247 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 29.40099152 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.591826458 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-10 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 15.16 -0.178 -0.12 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.958 0.032 0 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.12 -0.008 0.714 = 1.68 t

WL-X
0.063 0.008 -0.696 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -1.32 -1.464 0.018
WL-Z 1.279 1.419 -0.018 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 26.44126 11.80413393 0.244419643 0.229591837 0.47401148 12.27814541 SAFE


2 DL+WL+X 23.36326 10.43002679 0.311383929 1.136479592 1.44786352 11.87789031 SAFE
3 DL+WL-X 23.54626 10.51172321 0.284598214 1.56122449 1.845822704 12.35754592 SAFE
4 DL+WL+Z 22.16326 9.8943125 2.748883929 0.195153061 2.94403699 12.83834949 SAFE
5 DL+WL-Z 24.76226 11.05458036 2.077566964 0.264030612 2.341597577 13.39617793 SAFE
6 DL+EQ+X 23.48326 10.48359821 0.297991071 0.229591837 0.527582908 11.01118112 SAFE
7 DL+EQ-X 23.48326 10.48359821 0.297991071 0.229591837 0.527582908 11.01118112 SAFE
8 DL+EQ+Z 23.48326 10.48359821 0.297991071 0.229591837 0.527582908 11.01118112 SAFE
9 DL+EQ-Z 23.48326 10.48359821 0.297991071 0.229591837 0.527582908 11.01118112 SAFE
10 DL+LL+WL+X 26.32126 11.7505625 0.2578125 1.136479592 1.394292092 13.14485459 SAFE
11 DL+LL+WL-X 26.50426 11.83225893 0.231026786 1.56122449 1.792251276 13.6245102 SAFE
12 DL+LL+WL+Z 25.12126 11.21484821 2.6953125 0.195153061 2.890465561 14.10531378 SAFE
13 DL+LL+WL-Z 27.72026 12.37511607 2.131138393 0.264030612 2.395169005 14.77028508 SAFE
14 DL+LL+EQ+X 26.44126 11.80413393 0.244419643 0.229591837 0.47401148 12.27814541 SAFE
15 DL+LL+EQ-X 26.44126 11.80413393 0.244419643 0.229591837 0.47401148 12.27814541 SAFE
16 DL+LL+EQ+Z 26.44126 11.80413393 0.244419643 0.229591837 0.47401148 12.27814541 SAFE
17 DL+LL+EQ-Z 26.44126 11.80413393 0.244419643 0.229591837 0.47401148 12.27814541 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.189 -0.297 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.001 0.049 F.O.S =1.66
WL+X -0.607 -0.007 WHERE,
WL-X 0.594 0.007 μ =COEFFICIENT OF FRICTION
WL+Z -0.017 -1.282 W= TOTAL VERTICAL LOAD
WL-Z 0.017 1.221 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.188 0.248 0.311204113 15.26826217 49.06189067 SAFE


2 DL+WL+X 0.418 0.304 0.516855879 13.49089941 26.10185924 SAFE
3 DL+WL-X 0.783 0.29 0.834978443 13.59657107 16.28373905 SAFE
4 DL+WL+Z 0.172 1.579 1.588340329 12.79797046 8.057448535 SAFE
5 DL+WL-Z 0.206 0.924 0.946684742 14.29873908 15.10401346 SAFE
6 DL+EQ+X 0.189 0.297 0.35203693 13.5601923 38.51923237 SAFE
7 DL+EQ-X 0.189 0.297 0.35203693 13.5601923 38.51923237 SAFE
8 DL+EQ+Z 0.189 0.297 0.35203693 13.5601923 38.51923237 SAFE
9 DL+EQ-Z 0.189 0.297 0.35203693 13.5601923 38.51923237 SAFE
10 DL+LL+WL+X 0.419 0.255 0.490495668 15.19896928 30.98695927 SAFE
11 DL+LL+WL-X 0.782 0.241 0.818293957 15.30464094 18.70310884 SAFE
12 DL+LL+WL+Z 0.171 1.53 1.539526226 14.50604032 9.422405466 SAFE
13 DL+LL+WL-Z 0.205 0.973 0.994361101 16.00680895 16.09758158 SAFE
14 DL+LL+EQ+X 0.188 0.248 0.311204113 15.26826217 49.06189067 SAFE
15 DL+LL+EQ-X 0.188 0.248 0.311204113 15.26826217 49.06189067 SAFE
16 DL+LL+EQ+Z 0.188 0.248 0.311204113 15.26826217 49.06189067 SAFE
17 DL+LL+EQ-Z 0.188 0.248 0.311204113 15.26826217 49.06189067 SAFE
Design Pressure, Pu = 10.43043686 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 3.305144681 t-m
Required footing depth,d req. = 99.7009767 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 319.9408639 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 6.352136049 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.260 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 31.01194177 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.624254037 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-11 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 13.302 0.138 0.051 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.986 -0.032 0.001 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.099 -0.008 0.713 = 1.68 t

WL-X
0.039 0.008 -0.695 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 1.293 -1.415 -0.008
WL-Z -1.342 1.462 0.007 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 24.61126 10.98716964 0.177455357 0.099489796 0.276945153 11.2641148 SAFE


2 DL+WL+X 21.52626 9.6099375 0.217633929 1.461734694 1.679368622 11.28930612 SAFE
3 DL+WL-X 21.66426 9.671544643 0.244419643 1.232142857 1.4765625 11.14810714 SAFE
4 DL+WL+Z 22.91826 10.23136607 2.137834821 0.082270408 2.22010523 12.4514713 SAFE
5 DL+WL-Z 20.28326 9.055026786 2.678571429 0.110969388 2.789540816 11.8445676 SAFE
6 DL+EQ+X 21.62526 9.654133929 0.231026786 0.097576531 0.328603316 9.982737245 SAFE
7 DL+EQ-X 21.62526 9.654133929 0.231026786 0.097576531 0.328603316 9.982737245 SAFE
8 DL+EQ+Z 21.62526 9.654133929 0.231026786 0.097576531 0.328603316 9.982737245 SAFE
9 DL+EQ-Z 21.62526 9.654133929 0.231026786 0.097576531 0.328603316 9.982737245 SAFE
10 DL+LL+WL+X 24.51226 10.94297321 0.1640625 1.463647959 1.627710459 12.57068367 SAFE
11 DL+LL+WL-X 24.65026 11.00458036 0.190848214 1.230229592 1.421077806 12.42565816 SAFE
12 DL+LL+WL+Z 25.90426 11.56440179 2.19140625 0.084183673 2.275589923 13.83999171 SAFE
13 DL+LL+WL-Z 23.26926 10.3880625 2.625 0.112882653 2.737882653 13.12594515 SAFE
14 DL+LL+EQ+X 24.61126 10.98716964 0.177455357 0.099489796 0.276945153 11.2641148 SAFE
15 DL+LL+EQ-X 24.61126 10.98716964 0.177455357 0.099489796 0.276945153 11.2641148 SAFE
16 DL+LL+EQ+Z 24.61126 10.98716964 0.177455357 0.099489796 0.276945153 11.2641148 SAFE
17 DL+LL+EQ-Z 24.61126 10.98716964 0.177455357 0.099489796 0.276945153 11.2641148 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.074 0.192 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.003 -0.049 F.O.S =1.66
WL+X -0.604 -0.007 WHERE,
WL-X 0.591 0.007 μ =COEFFICIENT OF FRICTION
WL+Z 0.007 -1.215 W= TOTAL VERTICAL LOAD
WL-Z -0.007 1.278 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.077 0.143 0.162413054 14.21154552 87.50248332 SAFE


2 DL+WL+X 0.678 0.185 0.702786596 12.43014067 17.68693475 SAFE
3 DL+WL-X 0.517 0.199 0.553976534 12.5098275 22.58187258 SAFE
4 DL+WL+Z 0.067 1.023 1.025191689 13.23393826 12.90874516 SAFE
5 DL+WL-Z 0.081 1.47 1.472229941 11.71238176 7.955538353 SAFE
6 DL+EQ+X 0.074 0.192 0.205766858 12.48730731 60.68667913 SAFE
7 DL+EQ-X 0.074 0.192 0.205766858 12.48730731 60.68667913 SAFE
8 DL+EQ+Z 0.074 0.192 0.205766858 12.48730731 60.68667913 SAFE
9 DL+EQ-Z 0.074 0.192 0.205766858 12.48730731 60.68667913 SAFE
10 DL+LL+WL+X 0.681 0.136 0.694447262 14.15437888 20.38222289 SAFE
11 DL+LL+WL-X 0.514 0.15 0.535440006 14.23406571 26.58386664 SAFE
12 DL+LL+WL+Z 0.07 1.072 1.074283017 14.95817647 13.92386944 SAFE
13 DL+LL+WL-Z 0.084 1.421 1.423480593 13.43661997 9.439271624 SAFE
14 DL+LL+EQ+X 0.077 0.143 0.162413054 14.21154552 87.50248332 SAFE
15 DL+LL+EQ-X 0.077 0.143 0.162413054 14.21154552 87.50248332 SAFE
16 DL+LL+EQ+Z 0.077 0.143 0.162413054 14.21154552 87.50248332 SAFE
17 DL+LL+EQ-Z 0.077 0.143 0.162413054 14.21154552 87.50248332 SAFE
Design Pressure, Pu = 9.48573023 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 3.005790767 t-m
Required footing depth,d req. = 95.07876856 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 290.2374731 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 200 mm
Ast Provided = 565.4866776 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.77680971 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.237 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.231756835 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.353 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 28.20312489 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.567714034 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=1.4m
FOOTING NODE-12 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 1.4 0.3
COLUMN SIZE 0.3 0.23 1.7

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.96574107 t/m2
LC1: DL + LL 17.96574107 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.45717634 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 12.899 -0.183 -0.002 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.957 0.042 0.001 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.101 -0.006 0.669 = 1.68 t

WL-X
0.058 0.006 -0.656 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 0.801 -1.154 -0.078
WL-Z -0.755 1.002 0.078 = 6.64326 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 2.24 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.597333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 0.522666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 23.17926 10.34788393 0.236049107 0.001913265 0.237962372 10.5858463 SAFE


2 DL+WL+X 21.12126 9.429133929 0.31640625 1.276147959 1.592554209 11.02168814 SAFE
3 DL+WL-X 21.28026 9.500116071 0.296316964 1.258928571 1.555245536 11.05536161 SAFE
4 DL+WL+Z 22.02326 9.8318125 2.23828125 0.153061224 2.391342474 12.22315497 SAFE
5 DL+WL-Z 20.46726 9.137169643 1.37109375 0.145408163 1.516501913 10.65367156 SAFE
6 DL+EQ+X 21.22226 9.474223214 0.306361607 0.003826531 0.310188138 9.784411352 SAFE
7 DL+EQ-X 21.22226 9.474223214 0.306361607 0.003826531 0.310188138 9.784411352 SAFE
8 DL+EQ+Z 21.22226 9.474223214 0.306361607 0.003826531 0.310188138 9.784411352 SAFE
9 DL+EQ-Z 21.22226 9.474223214 0.306361607 0.003826531 0.310188138 9.784411352 SAFE
10 DL+LL+WL+X 23.07826 10.30279464 0.24609375 1.278061224 1.524154974 11.82694962 SAFE
11 DL+LL+WL-X 23.23726 10.37377679 0.226004464 1.257015306 1.48301977 11.85679656 SAFE
12 DL+LL+WL+Z 23.98026 10.70547321 2.16796875 0.151147959 2.319116709 13.02458992 SAFE
13 DL+LL+WL-Z 22.42426 10.01083036 1.44140625 0.147321429 1.588727679 11.59955804 SAFE
14 DL+LL+EQ+X 23.17926 10.34788393 0.236049107 0.001913265 0.237962372 10.5858463 SAFE
15 DL+LL+EQ-X 23.17926 10.34788393 0.236049107 0.001913265 0.237962372 10.5858463 SAFE
16 DL+LL+EQ+Z 23.17926 10.34788393 0.236049107 0.001913265 0.237962372 10.5858463 SAFE
17 DL+LL+EQ-Z 23.17926 10.34788393 0.236049107 0.001913265 0.237962372 10.5858463 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.004 -0.297 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.003 0.071 F.O.S =1.66
WL+X -0.565 -0.004 WHERE,
WL-X 0.556 0.004 μ =COEFFICIENT OF FRICTION
WL+Z 0.068 -0.821 W= TOTAL VERTICAL LOAD
WL-Z -0.068 0.535 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.001 0.226 0.226002212 13.3846503 59.22353663 SAFE


2 DL+WL+X 0.561 0.301 0.63664904 12.19627715 19.15698663 SAFE
3 DL+WL-X 0.56 0.293 0.632019778 12.28809023 19.4425723 SAFE
4 DL+WL+Z 0.072 1.118 1.120316027 12.71712874 11.35137625 SAFE
5 DL+WL-Z 0.064 0.238 0.246454864 11.81863087 47.95454501 SAFE
6 DL+EQ+X 0.004 0.297 0.297026935 12.25459867 41.25753335 SAFE
7 DL+EQ-X 0.004 0.297 0.297026935 12.25459867 41.25753335 SAFE
8 DL+EQ+Z 0.004 0.297 0.297026935 12.25459867 41.25753335 SAFE
9 DL+EQ-Z 0.004 0.297 0.297026935 12.25459867 41.25753335 SAFE
10 DL+LL+WL+X 0.564 0.23 0.60909441 13.32632878 21.87892151 SAFE
11 DL+LL+WL-X 0.557 0.222 0.599610707 13.41814187 22.37808917 SAFE
12 DL+LL+WL+Z 0.069 1.047 1.049271176 13.84718038 13.19695108 SAFE
13 DL+LL+WL-Z 0.067 0.309 0.316180328 12.9486825 40.95347289 SAFE
14 DL+LL+EQ+X 0.001 0.226 0.226002212 13.3846503 59.22353663 SAFE
15 DL+LL+EQ-X 0.001 0.226 0.226002212 13.3846503 59.22353663 SAFE
16 DL+LL+EQ+Z 0.001 0.226 0.226002212 13.3846503 59.22353663 SAFE
17 DL+LL+EQ-Z 0.001 0.226 0.226002212 13.3846503 59.22353663 SAFE
Design Pressure, Pu = 9.257413903 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.65 m (Max value considering both sides)
Cantilever B.M (Mu) = 2.933443031 t-m
Required footing depth,d req. = 93.92755216 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 300 mm
Effective depth (d) = 244 mm Depth provided is ok

Reinforcement Calculation
Ast required = 283.0815276 sq.mm
Ast Minimum = 360 sq.mm
Dia provided = 12 mm
Required spacing = 314.1592654 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.637765067 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.231 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.309009113 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.400 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 544 mm
pedestal width + d,b = 474 mm
shear force, Vu = 27.52429114 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.554049469 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-13 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 30.002 0.162 0.102 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.455 -0.027 -0.002 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -1.433 -0.003 0.642 = 3.6 t

WL-X
1.57 0.004 -0.637 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -1.453 -1.327 0.062
WL-Z 1.475 1.453 -0.061 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 44.79249 13.99765313 0.158203125 0.09375 0.251953125 14.24960625 SAFE


2 DL+WL+X 40.90449 12.78265313 0.186328125 0.6975 0.883828125 13.66648125 SAFE
3 DL+WL-X 43.90749 13.72109063 0.19453125 0.5015625 0.69609375 14.41718438 SAFE
4 DL+WL+Z 40.88449 12.77640313 1.365234375 0.15375 1.518984375 14.2953875 SAFE
5 DL+WL-Z 43.81249 13.69140313 1.892578125 0.0384375 1.931015625 15.62241875 SAFE
6 DL+EQ+X 42.33749 13.23046563 0.18984375 0.095625 0.28546875 13.51593438 SAFE
7 DL+EQ-X 42.33749 13.23046563 0.18984375 0.095625 0.28546875 13.51593438 SAFE
8 DL+EQ+Z 42.33749 13.23046563 0.18984375 0.095625 0.28546875 13.51593438 SAFE
9 DL+EQ-Z 42.33749 13.23046563 0.18984375 0.095625 0.28546875 13.51593438 SAFE
10 DL+LL+WL+X 43.35949 13.54984063 0.1546875 0.695625 0.8503125 14.40015313 SAFE
11 DL+LL+WL-X 46.36249 14.48827813 0.162890625 0.5034375 0.666328125 15.15460625 SAFE
12 DL+LL+WL+Z 43.33949 13.54359063 1.396875 0.151875 1.54875 15.09234063 SAFE
13 DL+LL+WL-Z 46.26749 14.45859063 1.8609375 0.0365625 1.8975 16.35609063 SAFE
14 DL+LL+EQ+X 44.79249 13.99765313 0.158203125 0.09375 0.251953125 14.24960625 SAFE
15 DL+LL+EQ-X 44.79249 13.99765313 0.158203125 0.09375 0.251953125 14.24960625 SAFE
16 DL+LL+EQ+Z 44.79249 13.99765313 0.158203125 0.09375 0.251953125 14.24960625 SAFE
17 DL+LL+EQ-Z 44.79249 13.99765313 0.158203125 0.09375 0.251953125 14.24960625 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.152 0.228 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.003 -0.046 F.O.S =1.66
WL+X -0.501 0.001 WHERE,
WL-X 0.492 -0.001 μ =COEFFICIENT OF FRICTION
WL+Z -0.052 -0.735 W= TOTAL VERTICAL LOAD
WL-Z 0.052 0.977 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.149 0.182 0.23521267 25.865011 109.9643613 SAFE


2 DL+WL+X 0.653 0.229 0.691989884 23.61992119 34.13333305 SAFE
3 DL+WL-X 0.34 0.227 0.408814139 25.3539759 62.01834402 SAFE
4 DL+WL+Z 0.204 0.507 0.546502516 23.60837237 43.19901864 SAFE
5 DL+WL-Z 0.1 1.205 1.209142258 25.29911902 20.92319481 SAFE
6 DL+EQ+X 0.152 0.228 0.274021897 24.44739385 89.2169353 SAFE
7 DL+EQ-X 0.152 0.228 0.274021897 24.44739385 89.2169353 SAFE
8 DL+EQ+Z 0.152 0.228 0.274021897 24.44739385 89.2169353 SAFE
9 DL+EQ-Z 0.152 0.228 0.274021897 24.44739385 89.2169353 SAFE
10 DL+LL+WL+X 0.65 0.183 0.675269576 25.03753834 37.07784156 SAFE
11 DL+LL+WL-X 0.343 0.181 0.387827281 26.77159304 69.02967983 SAFE
12 DL+LL+WL+Z 0.201 0.553 0.588396125 25.02598952 42.53255325 SAFE
13 DL+LL+WL-Z 0.097 1.159 1.163052019 26.71673617 22.97123063 SAFE
14 DL+LL+EQ+X 0.149 0.182 0.23521267 25.865011 109.9643613 SAFE
15 DL+LL+EQ-X 0.149 0.182 0.23521267 25.865011 109.9643613 SAFE
16 DL+LL+EQ+Z 0.149 0.182 0.23521267 25.865011 109.9643613 SAFE
17 DL+LL+EQ-Z 0.149 0.182 0.23521267 25.865011 109.9643613 SAFE
Design Pressure, Pu = 12.89257813 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 7.573342126 t-m
Required footing depth,d req. = 150.9204055 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 452.492003 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 9.495383789 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.241 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 53.50956253 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.515216511 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-14 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 21.341 -0.118 0.112 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 3.594 0.023 -0.003 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.133 -0.005 0.717 = 3.6 t

WL-X
0.255 0.006 -0.705 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -2.265 -1.857 0.014
WL-Z 2.247 1.82 -0.015 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 37.27049 11.64702813 0.111328125 0.1021875 0.213515625 11.86054375 SAFE


2 DL+WL+X 33.54349 10.48234063 0.144140625 0.7771875 0.921328125 11.40366875 SAFE
3 DL+WL-X 33.93149 10.60359063 0.13125 0.5559375 0.6871875 11.29077813 SAFE
4 DL+WL+Z 31.41149 9.816090625 2.314453125 0.118125 2.432578125 12.24866875 SAFE
5 DL+WL-Z 35.92349 11.22609063 1.99453125 0.0909375 2.08546875 13.31155938 SAFE
6 DL+EQ+X 33.67649 10.52390313 0.13828125 0.105 0.24328125 10.76718438 SAFE
7 DL+EQ-X 33.67649 10.52390313 0.13828125 0.105 0.24328125 10.76718438 SAFE
8 DL+EQ+Z 33.67649 10.52390313 0.13828125 0.105 0.24328125 10.76718438 SAFE
9 DL+EQ-Z 33.67649 10.52390313 0.13828125 0.105 0.24328125 10.76718438 SAFE
10 DL+LL+WL+X 37.13749 11.60546563 0.1171875 0.774375 0.8915625 12.49702813 SAFE
11 DL+LL+WL-X 37.52549 11.72671563 0.104296875 0.55875 0.663046875 12.3897625 SAFE
12 DL+LL+WL+Z 35.00549 10.93921563 2.2875 0.1153125 2.4028125 13.34202813 SAFE
13 DL+LL+WL-Z 39.51749 12.34921563 2.021484375 0.088125 2.109609375 14.458825 SAFE
14 DL+LL+EQ+X 37.27049 11.64702813 0.111328125 0.1021875 0.213515625 11.86054375 SAFE
15 DL+LL+EQ-X 37.27049 11.64702813 0.111328125 0.1021875 0.213515625 11.86054375 SAFE
16 DL+LL+EQ+Z 37.27049 11.64702813 0.111328125 0.1021875 0.213515625 11.86054375 SAFE
17 DL+LL+EQ-Z 37.27049 11.64702813 0.111328125 0.1021875 0.213515625 11.86054375 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.165 -0.197 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.005 0.035 F.O.S =1.66
WL+X -0.621 -0.002 WHERE,
WL-X 0.603 0.003 μ =COEFFICIENT OF FRICTION
WL+Z -0.011 -1.585 W= TOTAL VERTICAL LOAD
WL-Z 0.012 1.537 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.16 0.162 0.227692775 21.52150134 94.51991307 SAFE


2 DL+WL+X 0.786 0.199 0.810800222 19.3693795 23.88921337 SAFE
3 DL+WL-X 0.438 0.194 0.479040708 19.59342653 40.90138104 SAFE
4 DL+WL+Z 0.176 1.782 1.790670266 18.13827573 10.12932201 SAFE
5 DL+WL-Z 0.153 1.34 1.348706417 20.74368859 15.38043293 SAFE
6 DL+EQ+X 0.165 0.197 0.256970815 19.44617913 75.67466016 SAFE
7 DL+EQ-X 0.165 0.197 0.256970815 19.44617913 75.67466016 SAFE
8 DL+EQ+Z 0.165 0.197 0.256970815 19.44617913 75.67466016 SAFE
9 DL+EQ-Z 0.165 0.197 0.256970815 19.44617913 75.67466016 SAFE
10 DL+LL+WL+X 0.781 0.164 0.798033207 21.44470172 26.87194157 SAFE
11 DL+LL+WL-X 0.443 0.159 0.470669736 21.66874875 46.03811783 SAFE
12 DL+LL+WL+Z 0.171 1.747 1.755348968 20.21359795 11.51542987 SAFE
13 DL+LL+WL-Z 0.148 1.375 1.382942154 22.81901081 16.50033644 SAFE
14 DL+LL+EQ+X 0.16 0.162 0.227692775 21.52150134 94.51991307 SAFE
15 DL+LL+EQ-X 0.16 0.162 0.227692775 21.52150134 94.51991307 SAFE
16 DL+LL+EQ+Z 0.16 0.162 0.227692775 21.52150134 94.51991307 SAFE
17 DL+LL+EQ-Z 0.16 0.162 0.227692775 21.52150134 94.51991307 SAFE
Design Pressure, Pu = 10.58171875 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.215900001 t-m
Required footing depth,d req. = 136.7275981 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 369.7987891 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 7.793435859 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.198 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 43.91853481 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.422869357 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-15 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 18 t/m2


Gross safe bearing capacity of soil 20.72984063 t/m2
LC1: DL + LL 20.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 25.91230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 22.939 0.176 -0.018 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 3.605 -0.025 -0.007 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.014 -0.006 0.72 = 3.6 t

WL-X
0.128 0.007 -0.708 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 2.243 -1.823 -0.007
WL-Z -2.268 1.857 0.007 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 38.87949 12.14984063 0.176953125 0.0234375 0.200390625 12.35023125 SAFE


2 DL+WL+X 35.26049 11.01890313 0.19921875 0.658125 0.85734375 11.87624688 SAFE
3 DL+WL-X 35.40249 11.06327813 0.214453125 0.680625 0.895078125 11.95835625 SAFE
4 DL+WL+Z 37.51749 11.72421563 1.930078125 0.0234375 1.953515625 13.67773125 SAFE
5 DL+WL-Z 33.00649 10.31452813 2.382421875 0.0103125 2.392734375 12.7072625 SAFE
6 DL+EQ+X 35.27449 11.02327813 0.20625 0.016875 0.223125 11.24640313 SAFE
7 DL+EQ-X 35.27449 11.02327813 0.20625 0.016875 0.223125 11.24640313 SAFE
8 DL+EQ+Z 35.27449 11.02327813 0.20625 0.016875 0.223125 11.24640313 SAFE
9 DL+EQ-Z 35.27449 11.02327813 0.20625 0.016875 0.223125 11.24640313 SAFE
10 DL+LL+WL+X 38.86549 12.14546563 0.169921875 0.6515625 0.821484375 12.96695 SAFE
11 DL+LL+WL-X 39.00749 12.18984063 0.18515625 0.6871875 0.87234375 13.06218438 SAFE
12 DL+LL+WL+Z 41.12249 12.85077813 1.959375 0.03 1.989375 14.84015313 SAFE
13 DL+LL+WL-Z 36.61149 11.44109063 2.353125 0.016875 2.37 13.81109063 SAFE
14 DL+LL+EQ+X 38.87949 12.14984063 0.176953125 0.0234375 0.200390625 12.35023125 SAFE
15 DL+LL+EQ-X 38.87949 12.14984063 0.176953125 0.0234375 0.200390625 12.35023125 SAFE
16 DL+LL+EQ+Z 38.87949 12.14984063 0.176953125 0.0234375 0.200390625 12.35023125 SAFE
17 DL+LL+EQ-Z 38.87949 12.14984063 0.176953125 0.0234375 0.200390625 12.35023125 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.033 0.259 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.011 -0.039 F.O.S =1.66
WL+X -0.624 -0.004 WHERE,
WL-X 0.607 0.005 μ =COEFFICIENT OF FRICTION
WL+Z 0.007 -1.54 W= TOTAL VERTICAL LOAD
WL-Z -0.006 1.584 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.044 0.22 0.224356859 22.45060358 100.066491 SAFE


2 DL+WL+X 0.591 0.255 0.643666062 20.36084535 31.63262215 SAFE
3 DL+WL-X 0.64 0.264 0.692312068 20.44284194 29.52836282 SAFE
4 DL+WL+Z 0.04 1.281 1.28162436 21.66412922 16.90364969 SAFE
5 DL+WL-Z 0.027 1.843 1.843197765 19.0592938 10.34034121 SAFE
6 DL+EQ+X 0.033 0.259 0.261093853 20.36892952 78.0138226 SAFE
7 DL+EQ-X 0.033 0.259 0.261093853 20.36892952 78.0138226 SAFE
8 DL+EQ+Z 0.033 0.259 0.261093853 20.36892952 78.0138226 SAFE
9 DL+EQ-Z 0.033 0.259 0.261093853 20.36892952 78.0138226 SAFE
10 DL+LL+WL+X 0.58 0.216 0.61891518 22.44251941 36.26105828 SAFE
11 DL+LL+WL-X 0.651 0.225 0.688785888 22.524516 32.70176754 SAFE
12 DL+LL+WL+Z 0.051 1.32 1.32098486 23.74580328 17.97583304 SAFE
13 DL+LL+WL-Z 0.038 1.804 1.804400177 21.14096786 11.71634105 SAFE
14 DL+LL+EQ+X 0.044 0.22 0.224356859 22.45060358 100.066491 SAFE
15 DL+LL+EQ-X 0.044 0.22 0.224356859 22.45060358 100.066491 SAFE
16 DL+LL+EQ+Z 0.044 0.22 0.224356859 22.45060358 100.066491 SAFE
17 DL+LL+EQ-Z 0.044 0.22 0.224356859 22.45060358 100.066491 SAFE
Design Pressure, Pu = 10.94789063 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.430996226 t-m
Required footing depth,d req. = 139.0731535 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 382.8539496 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 8.063121445 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.205 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 45.43830042 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.437502411 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-16 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 22.392 -0.185 -0.007 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.399 0.031 -0.007 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.069 -0.004 0.677 = 3.6 t

WL-X
0.156 0.005 -0.668 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 1.417 -1.458 -0.077
WL-Z -1.396 1.329 0.077 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 37.12649 11.60202813 0.18046875 0.013125 0.19359375 11.79562188 SAFE


2 DL+WL+X 34.65849 10.83077813 0.221484375 0.628125 0.849609375 11.6803875 SAFE
3 DL+WL-X 34.88349 10.90109063 0.2109375 0.6328125 0.84375 11.74484063 SAFE
4 DL+WL+Z 36.14449 11.29515313 1.925390625 0.07875 2.004140625 13.29929375 SAFE
5 DL+WL-Z 33.33149 10.41609063 1.340625 0.065625 1.40625 11.82234063 SAFE
6 DL+EQ+X 34.72749 10.85234063 0.216796875 0.0065625 0.223359375 11.0757 SAFE
7 DL+EQ-X 34.72749 10.85234063 0.216796875 0.0065625 0.223359375 11.0757 SAFE
8 DL+EQ+Z 34.72749 10.85234063 0.216796875 0.0065625 0.223359375 11.0757 SAFE
9 DL+EQ-Z 34.72749 10.85234063 0.216796875 0.0065625 0.223359375 11.0757 SAFE
10 DL+LL+WL+X 37.05749 11.58046563 0.18515625 0.6215625 0.80671875 12.38718438 SAFE
11 DL+LL+WL-X 37.28249 11.65077813 0.174609375 0.639375 0.813984375 12.4647625 SAFE
12 DL+LL+WL+Z 38.54349 12.04484063 1.8890625 0.0853125 1.974375 14.01921563 SAFE
13 DL+LL+WL-Z 35.73049 11.16577813 1.376953125 0.0590625 1.436015625 12.60179375 SAFE
14 DL+LL+EQ+X 37.12649 11.60202813 0.18046875 0.013125 0.19359375 11.79562188 SAFE
15 DL+LL+EQ-X 37.12649 11.60202813 0.18046875 0.013125 0.19359375 11.79562188 SAFE
16 DL+LL+EQ+Z 37.12649 11.60202813 0.18046875 0.013125 0.19359375 11.79562188 SAFE
17 DL+LL+EQ-Z 37.12649 11.60202813 0.18046875 0.013125 0.19359375 11.79562188 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.012 -0.288 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.011 0.052 F.O.S =1.66
WL+X -0.585 -0.001 WHERE,
WL-X 0.571 0.001 μ =COEFFICIENT OF FRICTION
WL+Z 0.067 -0.983 W= TOTAL VERTICAL LOAD
WL-Z -0.067 0.737 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.023 0.236 0.237118114 21.43834987 90.41211363 SAFE


2 DL+WL+X 0.573 0.289 0.641755405 20.01322599 31.18513039 SAFE
3 DL+WL-X 0.583 0.287 0.649813819 20.14315017 30.9983407 SAFE
4 DL+WL+Z 0.079 1.271 1.273452787 20.87130301 16.38953813 SAFE
5 DL+WL-Z 0.055 0.449 0.452356054 19.24696206 42.54825788 SAFE
6 DL+EQ+X 0.012 0.288 0.288249892 20.0530694 69.56835021 SAFE
7 DL+EQ-X 0.012 0.288 0.288249892 20.0530694 69.56835021 SAFE
8 DL+EQ+Z 0.012 0.288 0.288249892 20.0530694 69.56835021 SAFE
9 DL+EQ-Z 0.012 0.288 0.288249892 20.0530694 69.56835021 SAFE
10 DL+LL+WL+X 0.562 0.237 0.609928684 21.39850646 35.08362044 SAFE
11 DL+LL+WL-X 0.594 0.235 0.638796525 21.52843063 33.70154627 SAFE
12 DL+LL+WL+Z 0.09 1.219 1.22231788 22.25658348 18.20850684 SAFE
13 DL+LL+WL-Z 0.044 0.501 0.502928424 20.63224252 41.02421244 SAFE
14 DL+LL+EQ+X 0.023 0.236 0.237118114 21.43834987 90.41211363 SAFE
15 DL+LL+EQ-X 0.023 0.236 0.237118114 21.43834987 90.41211363 SAFE
16 DL+LL+EQ+Z 0.023 0.236 0.237118114 21.43834987 90.41211363 SAFE
17 DL+LL+EQ-Z 0.023 0.236 0.237118114 21.43834987 90.41211363 SAFE
Design Pressure, Pu = 10.56945313 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.208694943 t-m
Required footing depth,d req. = 136.6483324 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 369.3617928 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 7.784402227 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.198 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 43.86762736 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.422379195 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-17 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 31.248 0.081 -0.066 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.94 -0.026 0 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 1.335 -0.015 0.745 = 3.6 t

WL-X
-1.438 0.016 -0.762 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -1.545 -1.514 0.065
WL-Z 1.587 1.63 -0.065 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 46.52349 14.53859063 0.064453125 0.061875 0.126328125 14.66491875 SAFE


2 DL+WL+X 44.91849 14.03702813 0.07734375 0.6365625 0.71390625 14.75093438 SAFE
3 DL+WL-X 42.14549 13.17046563 0.113671875 0.77625 0.889921875 14.0603875 SAFE
4 DL+WL+Z 42.03849 13.13702813 1.679296875 0.0009375 1.680234375 14.8172625 SAFE
5 DL+WL-Z 45.17049 14.11577813 2.005078125 0.1228125 2.127890625 16.24366875 SAFE
6 DL+EQ+X 43.58349 13.61984063 0.094921875 0.061875 0.156796875 13.7766375 SAFE
7 DL+EQ-X 43.58349 13.61984063 0.094921875 0.061875 0.156796875 13.7766375 SAFE
8 DL+EQ+Z 43.58349 13.61984063 0.094921875 0.061875 0.156796875 13.7766375 SAFE
9 DL+EQ-Z 43.58349 13.61984063 0.094921875 0.061875 0.156796875 13.7766375 SAFE
10 DL+LL+WL+X 47.85849 14.95577813 0.046875 0.6365625 0.6834375 15.63921563 SAFE
11 DL+LL+WL-X 45.08549 14.08921563 0.083203125 0.77625 0.859453125 14.94866875 SAFE
12 DL+LL+WL+Z 44.97849 14.05577813 1.709765625 0.0009375 1.710703125 15.76648125 SAFE
13 DL+LL+WL-Z 48.11049 15.03452813 1.974609375 0.1228125 2.097421875 17.13195 SAFE
14 DL+LL+EQ+X 46.52349 14.53859063 0.064453125 0.061875 0.126328125 14.66491875 SAFE
15 DL+LL+EQ-X 46.52349 14.53859063 0.064453125 0.061875 0.126328125 14.66491875 SAFE
16 DL+LL+EQ+Z 46.52349 14.53859063 0.064453125 0.061875 0.126328125 14.66491875 SAFE
17 DL+LL+EQ-Z 46.52349 14.53859063 0.064453125 0.061875 0.126328125 14.66491875 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.12 0.108 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.001 -0.042 F.O.S =1.66
WL+X -0.671 -0.012 WHERE,
WL-X 0.686 0.012 μ =COEFFICIENT OF FRICTION
WL+Z -0.059 -0.863 W= TOTAL VERTICAL LOAD
WL-Z 0.059 1.084 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.121 0.066 0.137829605 26.86456101 194.9113982 SAFE


2 DL+WL+X 0.551 0.096 0.559300456 25.93776854 46.37537528 SAFE
3 DL+WL-X 0.806 0.12 0.814884041 24.33652522 29.86501637 SAFE
4 DL+WL+Z 0.061 0.755 0.75746023 24.27473905 32.04754268 SAFE
5 DL+WL-Z 0.179 1.192 1.20536509 26.08328362 21.63932226 SAFE
6 DL+EQ+X 0.12 0.108 0.161443489 25.16688508 155.886653 SAFE
7 DL+EQ-X 0.12 0.108 0.161443489 25.16688508 155.886653 SAFE
8 DL+EQ+Z 0.12 0.108 0.161443489 25.16688508 155.886653 SAFE
9 DL+EQ-Z 0.12 0.108 0.161443489 25.16688508 155.886653 SAFE
10 DL+LL+WL+X 0.55 0.054 0.552644551 27.63544447 50.00582094 SAFE
11 DL+LL+WL-X 0.807 0.078 0.810760754 26.03420115 32.11083051 SAFE
12 DL+LL+WL+Z 0.062 0.797 0.799407906 25.97241499 32.48956483 SAFE
13 DL+LL+WL-Z 0.18 1.15 1.164001718 27.78095955 23.86676851 SAFE
14 DL+LL+EQ+X 0.121 0.066 0.137829605 26.86456101 194.9113982 SAFE
15 DL+LL+EQ-X 0.121 0.066 0.137829605 26.86456101 194.9113982 SAFE
16 DL+LL+EQ+Z 0.121 0.066 0.137829605 26.86456101 194.9113982 SAFE
17 DL+LL+EQ-Z 0.121 0.066 0.137829605 26.86456101 194.9113982 SAFE
Design Pressure, Pu = 13.51382813 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 7.938276025 t-m
Required footing depth,d req. = 154.5137999 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 474.8475974 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 9.952934414 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.253 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 56.08800847 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.540043063 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-18 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 23.355 -0.061 0.014 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 4.399 0.019 0.002 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.007 -0.017 0.696 = 3.6 t

WL-X
-0.062 0.018 -0.718 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -2.621 -2.075 0.015
WL-Z 2.579 2.047 -0.015 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 40.08949 12.52796563 0.04921875 0.015 0.06421875 12.59218438 SAFE


2 DL+WL+X 35.69749 11.15546563 0.09140625 0.665625 0.75703125 11.91249688 SAFE
3 DL+WL-X 35.62849 11.13390313 0.050390625 0.66 0.710390625 11.84429375 SAFE
4 DL+WL+Z 33.06949 10.33421563 2.503125 0.0271875 2.5303125 12.86452813 SAFE
5 DL+WL-Z 38.26949 11.95921563 2.32734375 0.0009375 2.32828125 14.28749688 SAFE
6 DL+EQ+X 35.69049 11.15327813 0.071484375 0.013125 0.084609375 11.2378875 SAFE
7 DL+EQ-X 35.69049 11.15327813 0.071484375 0.013125 0.084609375 11.2378875 SAFE
8 DL+EQ+Z 35.69049 11.15327813 0.071484375 0.013125 0.084609375 11.2378875 SAFE
9 DL+EQ-Z 35.69049 11.15327813 0.071484375 0.013125 0.084609375 11.2378875 SAFE
10 DL+LL+WL+X 40.09649 12.53015313 0.069140625 0.6675 0.736640625 13.26679375 SAFE
11 DL+LL+WL-X 40.02749 12.50859063 0.028125 0.658125 0.68625 13.19484063 SAFE
12 DL+LL+WL+Z 37.46849 11.70890313 2.480859375 0.0290625 2.509921875 14.218825 SAFE
13 DL+LL+WL-Z 42.66849 13.33390313 2.349609375 0.0009375 2.350546875 15.68445 SAFE
14 DL+LL+EQ+X 40.08949 12.52796563 0.04921875 0.015 0.06421875 12.59218438 SAFE
15 DL+LL+EQ-X 40.08949 12.52796563 0.04921875 0.015 0.06421875 12.59218438 SAFE
16 DL+LL+EQ+Z 40.08949 12.52796563 0.04921875 0.015 0.06421875 12.59218438 SAFE
17 DL+LL+EQ-Z 40.08949 12.52796563 0.04921875 0.015 0.06421875 12.59218438 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.015 -0.105 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.001 0.03 F.O.S =1.66
WL+X -0.594 -0.016 WHERE,
WL-X 0.615 0.016 μ =COEFFICIENT OF FRICTION
WL+Z -0.013 -1.76 W= TOTAL VERTICAL LOAD
WL-Z 0.013 1.724 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.016 0.075 0.076687678 23.14930694 301.8647514 SAFE


2 DL+WL+X 0.609 0.121 0.620904179 20.61318698 33.19866037 SAFE
3 DL+WL-X 0.6 0.089 0.606564918 20.57334356 33.91779337 SAFE
4 DL+WL+Z 0.028 1.865 1.865210176 19.09567257 10.23781278 SAFE
5 DL+WL-Z 0.002 1.619 1.619001235 22.0983647 13.649381 SAFE
6 DL+EQ+X 0.015 0.105 0.106066017 20.60914489 194.3048814 SAFE
7 DL+EQ-X 0.015 0.105 0.106066017 20.60914489 194.3048814 SAFE
8 DL+EQ+Z 0.015 0.105 0.106066017 20.60914489 194.3048814 SAFE
9 DL+EQ-Z 0.015 0.105 0.106066017 20.60914489 194.3048814 SAFE
10 DL+LL+WL+X 0.61 0.091 0.616750355 23.15334903 37.54087671 SAFE
11 DL+LL+WL-X 0.599 0.059 0.601898663 23.11350561 38.40099181 SAFE
12 DL+LL+WL+Z 0.029 1.835 1.835229141 21.63583462 11.78917343 SAFE
13 DL+LL+WL-Z 0.003 1.649 1.649002729 24.63852675 14.94147118 SAFE
14 DL+LL+EQ+X 0.016 0.075 0.076687678 23.14930694 301.8647514 SAFE
15 DL+LL+EQ-X 0.016 0.075 0.076687678 23.14930694 301.8647514 SAFE
16 DL+LL+EQ+Z 0.016 0.075 0.076687678 23.14930694 301.8647514 SAFE
17 DL+LL+EQ-Z 0.016 0.075 0.076687678 23.14930694 301.8647514 SAFE
Design Pressure, Pu = 11.55765625 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.789183987 t-m
Required footing depth,d req. = 142.8936614 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 404.6340243 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 8.512213828 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.216 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 47.96908142 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.461870021 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-19 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 26.914 0.182 0.036 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 4.416 -0.026 0.005 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.001 -0.016 0.694 = 3.6 t

WL-X
-0.057 0.017 -0.715 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 2.579 -2.044 -0.005
WL-Z -2.618 2.077 0.005 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 43.66549 13.64546563 0.1828125 0.0384375 0.22125 13.86671563 SAFE


2 DL+WL+X 39.25049 12.26577813 0.19453125 0.684375 0.87890625 13.14468438 SAFE
3 DL+WL-X 39.19249 12.24765313 0.233203125 0.6365625 0.869765625 13.11741875 SAFE
4 DL+WL+Z 41.82849 13.07140313 2.18203125 0.0290625 2.21109375 15.28249688 SAFE
5 DL+WL-Z 36.63149 11.44734063 2.647265625 0.0384375 2.685703125 14.13304375 SAFE
6 DL+EQ+X 39.24949 12.26546563 0.21328125 0.03375 0.24703125 12.51249688 SAFE
7 DL+EQ-X 39.24949 12.26546563 0.21328125 0.03375 0.24703125 12.51249688 SAFE
8 DL+EQ+Z 39.24949 12.26546563 0.21328125 0.03375 0.24703125 12.51249688 SAFE
9 DL+EQ-Z 39.24949 12.26546563 0.21328125 0.03375 0.24703125 12.51249688 SAFE
10 DL+LL+WL+X 43.66649 13.64577813 0.1640625 0.6890625 0.853125 14.49890313 SAFE
11 DL+LL+WL-X 43.60849 13.62765313 0.202734375 0.631875 0.834609375 14.4622625 SAFE
12 DL+LL+WL+Z 46.24449 14.45140313 2.2125 0.03375 2.24625 16.69765313 SAFE
13 DL+LL+WL-Z 41.04749 12.82734063 2.616796875 0.043125 2.659921875 15.4872625 SAFE
14 DL+LL+EQ+X 43.66549 13.64546563 0.1828125 0.0384375 0.22125 13.86671563 SAFE
15 DL+LL+EQ-X 43.66549 13.64546563 0.1828125 0.0384375 0.22125 13.86671563 SAFE
16 DL+LL+EQ+Z 43.66549 13.64546563 0.1828125 0.0384375 0.22125 13.86671563 SAFE
17 DL+LL+EQ-Z 43.66549 13.64546563 0.1828125 0.0384375 0.22125 13.86671563 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.05 0.272 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.007 -0.038 F.O.S =1.66
WL+X -0.591 -0.014 WHERE,
WL-X 0.61 0.015 μ =COEFFICIENT OF FRICTION
WL+Z 0.005 -1.721 W= TOTAL VERTICAL LOAD
WL-Z -0.005 1.762 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.057 0.234 0.240842272 25.21423522 104.6919007 SAFE


2 DL+WL+X 0.641 0.258 0.69097395 22.66483412 32.80128593 SAFE
3 DL+WL-X 0.56 0.287 0.629260677 22.63134255 35.96497186 SAFE
4 DL+WL+Z 0.045 1.449 1.449698589 24.15347648 16.66103331 SAFE
5 DL+WL-Z 0.055 2.034 2.034743473 21.15251668 10.39566754 SAFE
6 DL+EQ+X 0.05 0.272 0.276557408 22.66425668 81.95136347 SAFE
7 DL+EQ-X 0.05 0.272 0.276557408 22.66425668 81.95136347 SAFE
8 DL+EQ+Z 0.05 0.272 0.276557408 22.66425668 81.95136347 SAFE
9 DL+EQ-Z 0.05 0.272 0.276557408 22.66425668 81.95136347 SAFE
10 DL+LL+WL+X 0.648 0.22 0.684327407 25.21481266 36.84612425 SAFE
11 DL+LL+WL-X 0.553 0.249 0.606473412 25.1813211 41.52089866 SAFE
12 DL+LL+WL+Z 0.052 1.487 1.487908935 26.70345503 17.94696866 SAFE
13 DL+LL+WL-Z 0.062 1.996 1.996962694 23.70249522 11.86927292 SAFE
14 DL+LL+EQ+X 0.057 0.234 0.240842272 25.21423522 104.6919007 SAFE
15 DL+LL+EQ-X 0.057 0.234 0.240842272 25.21423522 104.6919007 SAFE
16 DL+LL+EQ+Z 0.057 0.234 0.240842272 25.21423522 104.6919007 SAFE
17 DL+LL+EQ-Z 0.057 0.234 0.240842272 25.21423522 104.6919007 SAFE
Design Pressure, Pu = 12.55265625 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 7.373665644 t-m
Required footing depth,d req. = 148.9175545 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 440.2824426 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 9.245031328 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.235 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 52.09874534 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.501632466 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-20 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 25.601 -0.208 0.015 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.921 0.026 0.005 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.018 -0.014 0.657 = 3.6 t

WL-X
-0.063 0.014 -0.672 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 1.644 -1.627 -0.075
WL-Z -1.603 1.514 0.075 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 40.85749 12.76796563 0.21328125 0.01875 0.23203125 12.99999688 SAFE


2 DL+WL+X 37.95449 11.86077813 0.26015625 0.63 0.89015625 12.75093438 SAFE
3 DL+WL-X 37.87349 11.83546563 0.22734375 0.6159375 0.84328125 12.67874688 SAFE
4 DL+WL+Z 39.58049 12.36890313 2.150390625 0.05625 2.206640625 14.57554375 SAFE
5 DL+WL-Z 36.33349 11.35421563 1.53046875 0.084375 1.61484375 12.96905938 SAFE
6 DL+EQ+X 37.93649 11.85515313 0.24375 0.0140625 0.2578125 12.11296563 SAFE
7 DL+EQ-X 37.93649 11.85515313 0.24375 0.0140625 0.2578125 12.11296563 SAFE
8 DL+EQ+Z 37.93649 11.85515313 0.24375 0.0140625 0.2578125 12.11296563 SAFE
9 DL+EQ-Z 37.93649 11.85515313 0.24375 0.0140625 0.2578125 12.11296563 SAFE
10 DL+LL+WL+X 40.87549 12.77359063 0.2296875 0.6346875 0.864375 13.63796563 SAFE
11 DL+LL+WL-X 40.79449 12.74827813 0.196875 0.61125 0.808125 13.55640313 SAFE
12 DL+LL+WL+Z 42.50149 13.28171563 2.119921875 0.0515625 2.171484375 15.4532 SAFE
13 DL+LL+WL-Z 39.25449 12.26702813 1.5609375 0.0890625 1.65 13.91702813 SAFE
14 DL+LL+EQ+X 40.85749 12.76796563 0.21328125 0.01875 0.23203125 12.99999688 SAFE
15 DL+LL+EQ-X 40.85749 12.76796563 0.21328125 0.01875 0.23203125 12.99999688 SAFE
16 DL+LL+EQ+Z 40.85749 12.76796563 0.21328125 0.01875 0.23203125 12.99999688 SAFE
17 DL+LL+EQ-Z 40.85749 12.76796563 0.21328125 0.01875 0.23203125 12.99999688 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.019 -0.323 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.007 0.046 F.O.S =1.66
WL+X -0.557 -0.01 WHERE,
WL-X 0.572 0.01 μ =COEFFICIENT OF FRICTION
WL+Z 0.064 -1.082 W= TOTAL VERTICAL LOAD
WL-Z -0.065 0.863 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.026 0.277 0.278217541 23.59278147 84.79976283 SAFE


2 DL+WL+X 0.576 0.333 0.665330745 21.91647085 32.9407156 SAFE
3 DL+WL-X 0.553 0.313 0.635435284 21.86969814 34.41687721 SAFE
4 DL+WL+Z 0.045 1.405 1.405720456 22.85538958 16.25884399 SAFE
5 DL+WL-Z 0.084 0.54 0.546494282 20.98043932 38.39095855 SAFE
6 DL+EQ+X 0.019 0.323 0.323558341 21.90607691 67.70363839 SAFE
7 DL+EQ-X 0.019 0.323 0.323558341 21.90607691 67.70363839 SAFE
8 DL+EQ+Z 0.019 0.323 0.323558341 21.90607691 67.70363839 SAFE
9 DL+EQ-Z 0.019 0.323 0.323558341 21.90607691 67.70363839 SAFE
10 DL+LL+WL+X 0.583 0.287 0.649813819 23.60317541 36.3229816 SAFE
11 DL+LL+WL-X 0.546 0.267 0.607786969 23.5564027 38.75766328 SAFE
12 DL+LL+WL+Z 0.038 1.359 1.359531169 24.54209414 18.05188045 SAFE
13 DL+LL+WL-Z 0.091 0.586 0.593023608 22.66714388 38.22300422 SAFE
14 DL+LL+EQ+X 0.026 0.277 0.278217541 23.59278147 84.79976283 SAFE
15 DL+LL+EQ-X 0.026 0.277 0.278217541 23.59278147 84.79976283 SAFE
16 DL+LL+EQ+Z 0.026 0.277 0.278217541 23.59278147 84.79976283 SAFE
17 DL+LL+EQ-Z 0.026 0.277 0.278217541 23.59278147 84.79976283 SAFE
Design Pressure, Pu = 11.84570313 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.958388123 t-m
Required footing depth,d req. = 144.6633439 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 414.9401878 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 8.724360352 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.221 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 49.16459578 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.473381024 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-21 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 22.238 0.108 0.038 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.993 -0.023 0.005 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.005 0.007 0.715 = 3.6 t

WL-X
-0.049 -0.007 -0.76 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -1.601 -1.511 0.062
WL-Z 1.64 1.621 -0.062 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 37.56649 11.73952813 0.099609375 0.0403125 0.139921875 11.87945 SAFE


2 DL+WL+X 34.57849 10.80577813 0.134765625 0.7059375 0.840703125 11.64648125 SAFE
3 DL+WL-X 34.52449 10.78890313 0.118359375 0.676875 0.795234375 11.5841375 SAFE
4 DL+WL+Z 32.97249 10.30390313 1.644140625 0.09375 1.737890625 12.04179375 SAFE
5 DL+WL-Z 36.21349 11.31671563 2.026171875 0.0225 2.048671875 13.3653875 SAFE
6 DL+EQ+X 34.57349 10.80421563 0.1265625 0.035625 0.1621875 10.96640313 SAFE
7 DL+EQ-X 34.57349 10.80421563 0.1265625 0.035625 0.1621875 10.96640313 SAFE
8 DL+EQ+Z 34.57349 10.80421563 0.1265625 0.035625 0.1621875 10.96640313 SAFE
9 DL+EQ-Z 34.57349 10.80421563 0.1265625 0.035625 0.1621875 10.96640313 SAFE
10 DL+LL+WL+X 37.57149 11.74109063 0.1078125 0.710625 0.8184375 12.55952813 SAFE
11 DL+LL+WL-X 37.51749 11.72421563 0.09140625 0.6721875 0.76359375 12.48780938 SAFE
12 DL+LL+WL+Z 35.96549 11.23921563 1.67109375 0.0984375 1.76953125 13.00874688 SAFE
13 DL+LL+WL-Z 39.20649 12.25202813 1.99921875 0.0178125 2.01703125 14.26905938 SAFE
14 DL+LL+EQ+X 37.56649 11.73952813 0.099609375 0.0403125 0.139921875 11.87945 SAFE
15 DL+LL+EQ-X 37.56649 11.73952813 0.099609375 0.0403125 0.139921875 11.87945 SAFE
16 DL+LL+EQ+Z 37.56649 11.73952813 0.099609375 0.0403125 0.139921875 11.87945 SAFE
17 DL+LL+EQ-Z 37.56649 11.73952813 0.099609375 0.0403125 0.139921875 11.87945 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.038 0.159 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.007 -0.038 F.O.S =1.66
WL+X -0.634 0.004 WHERE,
WL-X 0.681 -0.004 μ =COEFFICIENT OF FRICTION
WL+Z -0.056 -0.862 W= TOTAL VERTICAL LOAD
WL-Z 0.056 1.076 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.045 0.121 0.129096863 21.69242382 168.0321531 SAFE


2 DL+WL+X 0.672 0.163 0.691486081 19.96703073 28.87553529 SAFE
3 DL+WL-X 0.643 0.155 0.661418173 19.93584892 30.14106616 SAFE
4 DL+WL+Z 0.094 0.703 0.709256653 19.03966081 26.84452903 SAFE
5 DL+WL-Z 0.018 1.235 1.235131167 20.91114642 16.93030423 SAFE
6 DL+EQ+X 0.038 0.159 0.163477827 19.96414352 122.1214146 SAFE
7 DL+EQ-X 0.038 0.159 0.163477827 19.96414352 122.1214146 SAFE
8 DL+EQ+Z 0.038 0.159 0.163477827 19.96414352 122.1214146 SAFE
9 DL+EQ-Z 0.038 0.159 0.163477827 19.96414352 122.1214146 SAFE
10 DL+LL+WL+X 0.679 0.125 0.690410023 21.69531102 31.42380658 SAFE
11 DL+LL+WL-X 0.636 0.117 0.646672251 21.66412922 33.50094146 SAFE
12 DL+LL+WL+Z 0.101 0.741 0.74785159 20.76794111 27.77013701 SAFE
13 DL+LL+WL-Z 0.011 1.197 1.197050542 22.63942672 18.91267405 SAFE
14 DL+LL+EQ+X 0.045 0.121 0.129096863 21.69242382 168.0321531 SAFE
15 DL+LL+EQ-X 0.045 0.121 0.129096863 21.69242382 168.0321531 SAFE
16 DL+LL+EQ+Z 0.045 0.121 0.129096863 21.69242382 168.0321531 SAFE
17 DL+LL+EQ-Z 0.045 0.121 0.129096863 21.69242382 168.0321531 SAFE
Design Pressure, Pu = 10.63554688 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.247519651 t-m
Required footing depth,d req. = 137.0749167 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 371.7168009 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 7.833080273 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.199 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 44.14194392 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.42502045 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-22 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 25.091 -0.07 0.001 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 4.499 0.02 0.009 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.121 0.009 0.703 = 3.6 t

WL-X
0.093 -0.01 -0.76 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -2.622 -2.068 0.014
WL-Z 2.581 2.038 -0.014 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 41.92549 13.10171563 0.05859375 0.009375 0.06796875 13.16968438 SAFE


2 DL+WL+X 37.30549 11.65796563 0.071484375 0.66 0.731484375 12.38945 SAFE
3 DL+WL-X 37.51949 11.72484063 0.09375 0.7115625 0.8053125 12.53015313 SAFE
4 DL+WL+Z 34.80449 10.87640313 2.50546875 0.0140625 2.51953125 13.39593438 SAFE
5 DL+WL-Z 40.00749 12.50234063 2.30625 0.0121875 2.3184375 14.82077813 SAFE
6 DL+EQ+X 37.42649 11.69577813 0.08203125 0.0009375 0.08296875 11.77874688 SAFE
7 DL+EQ-X 37.42649 11.69577813 0.08203125 0.0009375 0.08296875 11.77874688 SAFE
8 DL+EQ+Z 37.42649 11.69577813 0.08203125 0.0009375 0.08296875 11.77874688 SAFE
9 DL+EQ-Z 37.42649 11.69577813 0.08203125 0.0009375 0.08296875 11.77874688 SAFE
10 DL+LL+WL+X 41.80449 13.06390313 0.048046875 0.6684375 0.716484375 13.7803875 SAFE
11 DL+LL+WL-X 42.01849 13.13077813 0.0703125 0.703125 0.7734375 13.90421563 SAFE
12 DL+LL+WL+Z 39.30349 12.28234063 2.48203125 0.0225 2.50453125 14.78687188 SAFE
13 DL+LL+WL-Z 44.50649 13.90827813 2.3296875 0.00375 2.3334375 16.24171563 SAFE
14 DL+LL+EQ+X 41.92549 13.10171563 0.05859375 0.009375 0.06796875 13.16968438 SAFE
15 DL+LL+EQ-X 41.92549 13.10171563 0.05859375 0.009375 0.06796875 13.16968438 SAFE
16 DL+LL+EQ+Z 41.92549 13.10171563 0.05859375 0.009375 0.06796875 13.16968438 SAFE
17 DL+LL+EQ-Z 41.92549 13.10171563 0.05859375 0.009375 0.06796875 13.16968438 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.008 -0.113 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.011 0.032 F.O.S =1.66
WL+X -0.61 0.007 WHERE,
WL-X 0.67 -0.008 μ =COEFFICIENT OF FRICTION
WL+Z -0.012 -1.752 W= TOTAL VERTICAL LOAD
WL-Z 0.012 1.714 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.003 0.081 0.081055537 24.20948824 298.6777866 SAFE


2 DL+WL+X 0.602 0.106 0.611260992 21.54171177 35.24143052 SAFE
3 DL+WL-X 0.678 0.121 0.688712567 21.6652841 31.45765758 SAFE
4 DL+WL+Z 0.004 1.865 1.86500429 20.09753235 10.77613197 SAFE
5 DL+WL-Z 0.02 1.601 1.601124917 23.1019568 14.42857865 SAFE
6 DL+EQ+X 0.008 0.113 0.113282832 21.61158211 190.7754401 SAFE
7 DL+EQ-X 0.008 0.113 0.113282832 21.61158211 190.7754401 SAFE
8 DL+EQ+Z 0.008 0.113 0.113282832 21.61158211 190.7754401 SAFE
9 DL+EQ-Z 0.008 0.113 0.113282832 21.61158211 190.7754401 SAFE
10 DL+LL+WL+X 0.613 0.074 0.617450403 24.13961791 39.09563876 SAFE
11 DL+LL+WL-X 0.667 0.089 0.672911584 24.26319024 36.05702563 SAFE
12 DL+LL+WL+Z 0.015 1.833 1.833061374 22.69543848 12.38116672 SAFE
13 DL+LL+WL-Z 0.009 1.633 1.633024801 25.69986293 15.73758275 SAFE
14 DL+LL+EQ+X 0.003 0.081 0.081055537 24.20948824 298.6777866 SAFE
15 DL+LL+EQ-X 0.003 0.081 0.081055537 24.20948824 298.6777866 SAFE
16 DL+LL+EQ+Z 0.003 0.081 0.081055537 24.20948824 298.6777866 SAFE
17 DL+LL+EQ-Z 0.003 0.081 0.081055537 24.20948824 298.6777866 SAFE
Design Pressure, Pu = 12.0909375 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 7.102443393 t-m
Required footing depth,d req. = 146.1531115 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 423.7234234 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 8.904975469 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.226 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 50.18242046 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.483181143 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-23 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 26.259 0.074 -0.003 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 5.029 -0.018 0.007 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.176 0.009 0.704 = 3.6 t

WL-X
0.154 -0.01 -0.759 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 2.582 -2.038 -0.004
WL-Z -2.621 2.067 0.004 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 43.62349 13.63234063 0.065625 0.00375 0.069375 13.70171563 SAFE


2 DL+WL+X 38.41849 12.00577813 0.097265625 0.6571875 0.754453125 12.76023125 SAFE
3 DL+WL-X 38.74849 12.10890313 0.075 0.714375 0.789375 12.89827813 SAFE
4 DL+WL+Z 41.17649 12.86765313 2.3015625 0.0065625 2.308125 15.17577813 SAFE
5 DL+WL-Z 35.97349 11.24171563 2.508984375 0.0009375 2.509921875 13.7516375 SAFE
6 DL+EQ+X 38.59449 12.06077813 0.08671875 0.0028125 0.08953125 12.15030938 SAFE
7 DL+EQ-X 38.59449 12.06077813 0.08671875 0.0028125 0.08953125 12.15030938 SAFE
8 DL+EQ+Z 38.59449 12.06077813 0.08671875 0.0028125 0.08953125 12.15030938 SAFE
9 DL+EQ-Z 38.59449 12.06077813 0.08671875 0.0028125 0.08953125 12.15030938 SAFE
10 DL+LL+WL+X 43.44749 13.57734063 0.076171875 0.66375 0.739921875 14.3172625 SAFE
11 DL+LL+WL-X 43.77749 13.68046563 0.05390625 0.7078125 0.76171875 14.44218438 SAFE
12 DL+LL+WL+Z 46.20549 14.43921563 2.32265625 0 2.32265625 16.76187188 SAFE
13 DL+LL+WL-Z 41.00249 12.81327813 2.487890625 0.0075 2.495390625 15.30866875 SAFE
14 DL+LL+EQ+X 43.62349 13.63234063 0.065625 0.00375 0.069375 13.70171563 SAFE
15 DL+LL+EQ-X 43.62349 13.63234063 0.065625 0.00375 0.069375 13.70171563 SAFE
16 DL+LL+EQ+Z 43.62349 13.63234063 0.065625 0.00375 0.069375 13.70171563 SAFE
17 DL+LL+EQ-Z 43.62349 13.63234063 0.065625 0.00375 0.069375 13.70171563 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.013 0.111 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.008 -0.027 F.O.S =1.66
WL+X -0.61 0.007 WHERE,
WL-X 0.668 -0.008 μ =COEFFICIENT OF FRICTION
WL+Z 0.003 -1.714 W= TOTAL VERTICAL LOAD
WL-Z -0.003 1.752 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.005 0.084 0.084148678 25.18998271 299.3509028 SAFE


2 DL+WL+X 0.597 0.118 0.608549916 22.18440338 36.45453364 SAFE
3 DL+WL-X 0.681 0.103 0.688745236 22.37495884 32.48655333 SAFE
4 DL+WL+Z 0.016 1.603 1.603079848 23.77698509 14.83206536 SAFE
5 DL+WL-Z 0.01 1.863 1.863026838 20.77256063 11.14989876 SAFE
6 DL+EQ+X 0.013 0.111 0.111758669 22.28603296 199.4121194 SAFE
7 DL+EQ-X 0.013 0.111 0.111758669 22.28603296 199.4121194 SAFE
8 DL+EQ+Z 0.013 0.111 0.111758669 22.28603296 199.4121194 SAFE
9 DL+EQ-Z 0.013 0.111 0.111758669 22.28603296 199.4121194 SAFE
10 DL+LL+WL+X 0.605 0.091 0.611805525 25.08835313 41.00707189 SAFE
11 DL+LL+WL-X 0.673 0.076 0.677277639 25.27890859 37.32429235 SAFE
12 DL+LL+WL+Z 0.008 1.63 1.630019632 26.68093484 16.36847454 SAFE
13 DL+LL+WL-Z 0.002 1.836 1.836001089 23.67651039 12.89569517 SAFE
14 DL+LL+EQ+X 0.005 0.084 0.084148678 25.18998271 299.3509028 SAFE
15 DL+LL+EQ-X 0.005 0.084 0.084148678 25.18998271 299.3509028 SAFE
16 DL+LL+EQ+Z 0.005 0.084 0.084148678 25.18998271 299.3509028 SAFE
17 DL+LL+EQ-Z 0.005 0.084 0.084148678 25.18998271 299.3509028 SAFE
Design Pressure, Pu = 12.4459375 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 7.310977049 t-m
Required footing depth,d req. = 148.2831781 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 436.4525075 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 9.166432969 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.233 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 51.65581814 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.497367744 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-24 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 23.063 -0.088 -0.003 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 3.538 0.021 0.003 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X -0.171 0.007 0.667 = 3.6 t

WL-X
0.154 -0.008 -0.707 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 1.646 -1.621 -0.074
WL-Z -1.605 1.511 0.075 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 38.93649 12.16765313 0.078515625 0 0.078515625 12.24616875 SAFE


2 DL+WL+X 35.22749 11.00859063 0.094921875 0.6225 0.717421875 11.7260125 SAFE
3 DL+WL-X 35.55249 11.11015313 0.1125 0.665625 0.778125 11.88827813 SAFE
4 DL+WL+Z 37.04449 11.57640313 2.002734375 0.0721875 2.074921875 13.651325 SAFE
5 DL+WL-Z 33.79349 10.56046563 1.667578125 0.0675 1.735078125 12.29554375 SAFE
6 DL+EQ+X 35.39849 11.06202813 0.103125 0.0028125 0.1059375 11.16796563 SAFE
7 DL+EQ-X 35.39849 11.06202813 0.103125 0.0028125 0.1059375 11.16796563 SAFE
8 DL+EQ+Z 35.39849 11.06202813 0.103125 0.0028125 0.1059375 11.16796563 SAFE
9 DL+EQ-Z 35.39849 11.06202813 0.103125 0.0028125 0.1059375 11.16796563 SAFE
10 DL+LL+WL+X 38.76549 12.11421563 0.0703125 0.6253125 0.695625 12.80984063 SAFE
11 DL+LL+WL-X 39.09049 12.21577813 0.087890625 0.6628125 0.750703125 12.96648125 SAFE
12 DL+LL+WL+Z 40.58249 12.68202813 1.978125 0.069375 2.0475 14.72952813 SAFE
13 DL+LL+WL-Z 37.33149 11.66609063 1.6921875 0.0703125 1.7625 13.42859063 SAFE
14 DL+LL+EQ+X 38.93649 12.16765313 0.078515625 0 0.078515625 12.24616875 SAFE
15 DL+LL+EQ-X 38.93649 12.16765313 0.078515625 0 0.078515625 12.24616875 SAFE
16 DL+LL+EQ+Z 38.93649 12.16765313 0.078515625 0 0.078515625 12.24616875 SAFE
17 DL+LL+EQ-Z 38.93649 12.16765313 0.078515625 0 0.078515625 12.24616875 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL 0.01 -0.134 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL -0.003 0.036 F.O.S =1.66
WL+X -0.576 0.004 WHERE,
WL-X 0.618 -0.004 μ =COEFFICIENT OF FRICTION
WL+Z 0.065 -1.076 W= TOTAL VERTICAL LOAD
WL-Z -0.065 0.862 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.007 0.098 0.098249682 22.48351771 228.8406157 SAFE


2 DL+WL+X 0.566 0.13 0.580737462 20.3417898 35.02751437 SAFE
3 DL+WL-X 0.628 0.138 0.64298367 20.52945806 31.92842838 SAFE
4 DL+WL+Z 0.075 1.21 1.212322152 21.39099972 17.64464973 SAFE
5 DL+WL-Z 0.055 0.728 0.730074654 19.5137397 26.72841689 SAFE
6 DL+EQ+X 0.01 0.134 0.134372616 20.44053218 152.1182868 SAFE
7 DL+EQ-X 0.01 0.134 0.134372616 20.44053218 152.1182868 SAFE
8 DL+EQ+Z 0.01 0.134 0.134372616 20.44053218 152.1182868 SAFE
9 DL+EQ-Z 0.01 0.134 0.134372616 20.44053218 152.1182868 SAFE
10 DL+LL+WL+X 0.569 0.094 0.576712233 22.38477533 38.81446247 SAFE
11 DL+LL+WL-X 0.625 0.102 0.633268505 22.57244359 35.64434895 SAFE
12 DL+LL+WL+Z 0.072 1.174 1.176205764 23.43398525 19.92337222 SAFE
13 DL+LL+WL-Z 0.058 0.764 0.766198408 21.55672523 28.13465157 SAFE
14 DL+LL+EQ+X 0.007 0.098 0.098249682 22.48351771 228.8406157 SAFE
15 DL+LL+EQ-X 0.007 0.098 0.098249682 22.48351771 228.8406157 SAFE
16 DL+LL+EQ+Z 0.007 0.098 0.098249682 22.48351771 228.8406157 SAFE
17 DL+LL+EQ-Z 0.007 0.098 0.098249682 22.48351771 228.8406157 SAFE
Design Pressure, Pu = 10.92148438 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 6.4154847 t-m
Required footing depth,d req. = 138.9053304 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 381.9118828 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 8.043673242 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.204 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 45.32870349 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.436447158 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-25 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 15.18 0.187 0.192 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.4 -0.014 -0.007 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.679 0.033 0.62 = 3.6 t

WL-X
-0.642 -0.035 -0.588 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -1.403 -1.228 0.054
WL-Z 1.427 1.287 -0.054 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 28.91549 9.036090625 0.202734375 0.1734375 0.376171875 9.4122625 SAFE


2 DL+WL+X 28.19449 8.810778125 0.2578125 0.76125 1.0190625 9.829840625 SAFE
3 DL+WL-X 26.87349 8.397965625 0.178125 0.37125 0.549375 8.947340625 SAFE
4 DL+WL+Z 26.11249 8.160153125 1.219921875 0.230625 1.450546875 9.6107 SAFE
5 DL+WL-Z 28.94249 9.044528125 1.72734375 0.129375 1.85671875 10.90124688 SAFE
6 DL+EQ+X 27.51549 8.598590625 0.219140625 0.18 0.399140625 8.99773125 SAFE
7 DL+EQ-X 27.51549 8.598590625 0.219140625 0.18 0.399140625 8.99773125 SAFE
8 DL+EQ+Z 27.51549 8.598590625 0.219140625 0.18 0.399140625 8.99773125 SAFE
9 DL+EQ-Z 27.51549 8.598590625 0.219140625 0.18 0.399140625 8.99773125 SAFE
10 DL+LL+WL+X 29.59449 9.248278125 0.24140625 0.7546875 0.99609375 10.24437188 SAFE
11 DL+LL+WL-X 28.27349 8.835465625 0.16171875 0.3778125 0.53953125 9.374996875 SAFE
12 DL+LL+WL+Z 27.51249 8.597653125 1.236328125 0.2240625 1.460390625 10.05804375 SAFE
13 DL+LL+WL-Z 30.34249 9.482028125 1.7109375 0.1228125 1.83375 11.31577813 SAFE
14 DL+LL+EQ+X 28.91549 9.036090625 0.202734375 0.1734375 0.376171875 9.4122625 SAFE
15 DL+LL+EQ-X 28.91549 9.036090625 0.202734375 0.1734375 0.376171875 9.4122625 SAFE
16 DL+LL+EQ+Z 28.91549 9.036090625 0.202734375 0.1734375 0.376171875 9.4122625 SAFE
17 DL+LL+EQ-Z 28.91549 9.036090625 0.202734375 0.1734375 0.376171875 9.4122625 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE
CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.272 0.284 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.013 -0.021 F.O.S =1.66
WL+X -0.492 0.02 WHERE,
WL-X 0.412 -0.021 μ =COEFFICIENT OF FRICTION
WL+Z -0.044 -0.72 W= TOTAL VERTICAL LOAD
WL-Z 0.044 0.833 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.259 0.263 0.369120577 16.69698351 45.23449673 SAFE


2 DL+WL+X 0.764 0.304 0.822260299 16.2806487 19.79987202 SAFE
3 DL+WL-X 0.14 0.263 0.297941269 15.51784941 52.08358493 SAFE
4 DL+WL+Z 0.316 0.436 0.538471912 15.07841696 28.00223489 SAFE
5 DL+WL-Z 0.228 1.117 1.140032017 16.71257441 14.65974127 SAFE
6 DL+EQ+X 0.272 0.284 0.393242927 15.8885664 40.40394699 SAFE
7 DL+EQ-X 0.272 0.284 0.393242927 15.8885664 40.40394699 SAFE
8 DL+EQ+Z 0.272 0.284 0.393242927 15.8885664 40.40394699 SAFE
9 DL+EQ-Z 0.272 0.284 0.393242927 15.8885664 40.40394699 SAFE
10 DL+LL+WL+X 0.751 0.283 0.802552179 17.08906581 21.29340155 SAFE
11 DL+LL+WL-X 0.153 0.242 0.286309273 16.32626652 57.02318451 SAFE
12 DL+LL+WL+Z 0.303 0.457 0.548322898 15.88683407 28.9735011 SAFE
13 DL+LL+WL-Z 0.215 1.096 1.116888983 17.52099152 15.687317 SAFE
14 DL+LL+EQ+X 0.259 0.263 0.369120577 16.69698351 45.23449673 SAFE
15 DL+LL+EQ-X 0.259 0.263 0.369120577 16.69698351 45.23449673 SAFE
16 DL+LL+EQ+Z 0.259 0.263 0.369120577 16.69698351 45.23449673 SAFE
17 DL+LL+EQ-Z 0.259 0.263 0.369120577 16.69698351 45.23449673 SAFE
Design Pressure, Pu = 8.17140625 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 4.800037245 t-m
Required footing depth,d req. = 120.150748 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 284.3083278 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 6.018240703 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.153 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 33.91473524 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.326547831 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-26 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 19.164 -0.114 0.17 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.086 0.01 -0.009 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.889 0.042 0.595 = 3.6 t

WL-X
-0.865 -0.045 -0.549 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z -2.277 -1.647 0.011
WL-Z 2.252 1.631 -0.011 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 33.58549 10.49546563 0.121875 0.1509375 0.2728125 10.76827813 SAFE


2 DL+WL+X 32.38849 10.12140313 0.084375 0.7171875 0.8015625 10.92296563 SAFE
3 DL+WL-X 30.63449 9.573278125 0.186328125 0.3553125 0.541640625 10.11491875 SAFE
4 DL+WL+Z 29.22249 9.132028125 2.063671875 0.1696875 2.233359375 11.3653875 SAFE
5 DL+WL-Z 33.75149 10.54734063 1.777734375 0.1490625 1.926796875 12.4741375 SAFE
6 DL+EQ+X 31.49949 9.843590625 0.13359375 0.159375 0.29296875 10.13655938 SAFE
7 DL+EQ-X 31.49949 9.843590625 0.13359375 0.159375 0.29296875 10.13655938 SAFE
8 DL+EQ+Z 31.49949 9.843590625 0.13359375 0.159375 0.29296875 10.13655938 SAFE
9 DL+EQ-Z 31.49949 9.843590625 0.13359375 0.159375 0.29296875 10.13655938 SAFE
10 DL+LL+WL+X 34.47449 10.77327813 0.07265625 0.70875 0.78140625 11.55468438 SAFE
11 DL+LL+WL-X 32.72049 10.22515313 0.174609375 0.36375 0.538359375 10.7635125 SAFE
12 DL+LL+WL+Z 31.30849 9.783903125 2.051953125 0.16125 2.213203125 11.99710625 SAFE
13 DL+LL+WL-Z 35.83749 11.19921563 1.789453125 0.140625 1.930078125 13.12929375 SAFE
14 DL+LL+EQ+X 33.58549 10.49546563 0.121875 0.1509375 0.2728125 10.76827813 SAFE
15 DL+LL+EQ-X 33.58549 10.49546563 0.121875 0.1509375 0.2728125 10.76827813 SAFE
16 DL+LL+EQ+Z 33.58549 10.49546563 0.121875 0.1509375 0.2728125 10.76827813 SAFE
17 DL+LL+EQ-Z 33.58549 10.49546563 0.121875 0.1509375 0.2728125 10.76827813 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.247 -0.178 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.018 0.017 F.O.S =1.66
WL+X -0.446 0.035 WHERE,
WL-X 0.335 -0.036 μ =COEFFICIENT OF FRICTION
WL+Z -0.007 -1.382 W= TOTAL VERTICAL LOAD
WL-Z 0.007 1.362 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.229 0.161 0.279932135 19.39363202 69.27976327 SAFE


2 DL+WL+X 0.693 0.143 0.70760017 18.70243539 26.43079551 SAFE
3 DL+WL-X 0.088 0.214 0.231387122 17.68960423 76.4502541 SAFE
4 DL+WL+Z 0.254 1.56 1.580542945 16.87425783 10.67624128 SAFE
5 DL+WL-Z 0.24 1.184 1.208079468 19.48948719 16.13262017 SAFE
6 DL+EQ+X 0.247 0.178 0.304455251 18.18909052 59.74306716 SAFE
7 DL+EQ-X 0.247 0.178 0.304455251 18.18909052 59.74306716 SAFE
8 DL+EQ+Z 0.247 0.178 0.304455251 18.18909052 59.74306716 SAFE
9 DL+EQ-Z 0.247 0.178 0.304455251 18.18909052 59.74306716 SAFE
10 DL+LL+WL+X 0.675 0.126 0.686659304 19.90697688 28.99105388 SAFE
11 DL+LL+WL-X 0.106 0.197 0.223707398 18.89414573 84.45919037 SAFE
12 DL+LL+WL+Z 0.236 1.543 1.560943625 18.07879933 11.58196814 SAFE
13 DL+LL+WL-Z 0.222 1.201 1.221345569 20.69402869 16.94363103 SAFE
14 DL+LL+EQ+X 0.229 0.161 0.279932135 19.39363202 69.27976327 SAFE
15 DL+LL+EQ-X 0.229 0.161 0.279932135 19.39363202 69.27976327 SAFE
16 DL+LL+EQ+Z 0.229 0.161 0.279932135 19.39363202 69.27976327 SAFE
17 DL+LL+EQ-Z 0.229 0.161 0.279932135 19.39363202 69.27976327 SAFE
Design Pressure, Pu = 9.744296875 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 5.72398269 t-m
Required footing depth,d req. = 131.2058899 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 340.0094686 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 7.176674648 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.182 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 40.44288566 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.389404089 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-27 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 19.162 0.117 0.169 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 2.583 -0.01 -0.008 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.759 0.042 0.594 = 3.6 t

WL-X
-0.726 -0.045 -0.547 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 2.254 -1.632 -0.003
WL-Z -2.278 1.646 0.003 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 34.08049 10.65015313 0.125390625 0.1509375 0.276328125 10.92648125 SAFE


2 DL+WL+X 32.25649 10.08015313 0.186328125 0.7153125 0.901640625 10.98179375 SAFE
3 DL+WL-X 30.77149 9.616090625 0.084375 0.354375 0.43875 10.05484063 SAFE
4 DL+WL+Z 33.75149 10.54734063 1.775390625 0.155625 1.931015625 12.47835625 SAFE
5 DL+WL-Z 29.21949 9.131090625 2.066015625 0.16125 2.227265625 11.35835625 SAFE
6 DL+EQ+X 31.49749 9.842965625 0.137109375 0.1584375 0.295546875 10.1385125 SAFE
7 DL+EQ-X 31.49749 9.842965625 0.137109375 0.1584375 0.295546875 10.1385125 SAFE
8 DL+EQ+Z 31.49749 9.842965625 0.137109375 0.1584375 0.295546875 10.1385125 SAFE
9 DL+EQ-Z 31.49749 9.842965625 0.137109375 0.1584375 0.295546875 10.1385125 SAFE
10 DL+LL+WL+X 34.83949 10.88734063 0.174609375 0.7078125 0.882421875 11.7697625 SAFE
11 DL+LL+WL-X 33.35449 10.42327813 0.07265625 0.361875 0.43453125 10.85780938 SAFE
12 DL+LL+WL+Z 36.33449 11.35452813 1.787109375 0.148125 1.935234375 13.2897625 SAFE
13 DL+LL+WL-Z 31.80249 9.938278125 2.054296875 0.15375 2.208046875 12.146325 SAFE
14 DL+LL+EQ+X 34.08049 10.65015313 0.125390625 0.1509375 0.276328125 10.92648125 SAFE
15 DL+LL+EQ-X 34.08049 10.65015313 0.125390625 0.1509375 0.276328125 10.92648125 SAFE
16 DL+LL+EQ+Z 34.08049 10.65015313 0.125390625 0.1509375 0.276328125 10.92648125 SAFE
17 DL+LL+EQ-Z 34.08049 10.65015313 0.125390625 0.1509375 0.276328125 10.92648125 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z

1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.248 0.18 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.016 -0.014 F.O.S =1.66
WL+X -0.443 0.034 WHERE,
WL-X 0.33 -0.036 μ =COEFFICIENT OF FRICTION
WL+Z 0.002 -1.362 W= TOTAL VERTICAL LOAD
WL-Z -0.002 1.381 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.232 0.166 0.2852718 19.67946521 68.9849652 SAFE


2 DL+WL+X 0.691 0.214 0.723378877 18.6262132 25.74890391 SAFE
3 DL+WL-X 0.082 0.144 0.165710591 17.76871362 107.2273867 SAFE
4 DL+WL+Z 0.246 1.182 1.207327627 19.48948719 16.14266645 SAFE
5 DL+WL-Z 0.25 1.561 1.580892469 16.87252551 10.67278505 SAFE
6 DL+EQ+X 0.248 0.18 0.306437596 18.18793564 59.35282061 SAFE
7 DL+EQ-X 0.248 0.18 0.306437596 18.18793564 59.35282061 SAFE
8 DL+EQ+Z 0.248 0.18 0.306437596 18.18793564 59.35282061 SAFE
9 DL+EQ-Z 0.248 0.18 0.306437596 18.18793564 59.35282061 SAFE
10 DL+LL+WL+X 0.675 0.2 0.704006392 20.11774277 28.57607971 SAFE
11 DL+LL+WL-X 0.098 0.13 0.162800491 19.26024319 118.305805 SAFE
12 DL+LL+WL+Z 0.23 1.196 1.217914611 20.98101676 17.22700144 SAFE
13 DL+LL+WL-Z 0.234 1.547 1.564597392 18.36405508 11.73723999 SAFE
14 DL+LL+EQ+X 0.232 0.166 0.2852718 19.67946521 68.9849652 SAFE
15 DL+LL+EQ-X 0.232 0.166 0.2852718 19.67946521 68.9849652 SAFE
16 DL+LL+EQ+Z 0.232 0.166 0.2852718 19.67946521 68.9849652 SAFE
17 DL+LL+EQ-Z 0.232 0.166 0.2852718 19.67946521 68.9849652 SAFE
Design Pressure, Pu = 9.748515625 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 5.726460863 t-m
Required footing depth,d req. = 131.2342893 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 340.1593069 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 7.179781758 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.182 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 40.46039523 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.38957268 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm
SAMARTH INFRA ENGG TECHNOCRATS PVT. LTD.
DESIGN BY: NRK DATE : 05.03.19
CHECKED BY: MPB DATE : 06.03.19
APPROVED BY: MRRK DATE : 07.03.19
Building RANASTHALAM ADMIN BUILDING REV 1
x B=2m
FOOTING NODE-28 0.23m
Z

L=1.6m
LENGTH (m), L WIDTH (m), B HEIGHT (m), H

0.3m
FOOTING SIZE 1.6 2 0.45
COLUMN SIZE 0.3 0.23 1.55

Net safe bearing capacity of soil 15 t/m2


Gross safe bearing capacity of soil 17.72984063 t/m2
LC1: DL + LL 17.72984063 t/m2 Fck = 25 N/sq.mm
LC2: DL+ LL+ WL/EQ 22.16230078 t/m2 Fy = 500 N/sq.mm
(Note: In DL+LL+WL/EQ Case, SBC may be increased by 25%)
Foundation Depth below G.L.(m) = 2 m

LOAD P (t) Mx (t-m) Mz (t-m) Unit weight of RCC,W = 2.5 t/cu.m


DL 15.195 -0.183 0.175 Unit weight of SOIL, W' = 1.8 t/cu.m
LL 1.869 0.01 -0.005 WEIGHT OF FOOTING = ((L*B*H*W))
WL+X 0.775 0.033 0.561 = 3.6 t

WL-X
-0.753 -0.035 -0.526 WEIGHT OF SOIL OVER BURDEN = ((footing size -column size)*(foundation
depth-footing depth)*unit wt of soil)
WL+Z 1.415 -1.287 -0.063
WL-Z -1.39 1.228 0.063 = 8.73549 t
EQ+X 0 0 0 AREA OF FOOTING = L*B
EQ-X 0 0 0 = 3.2 sq.m
EQ+Z 0 0 0 SECTION MODULUS : Zxx = B*L*L/6
EQ-Z 0 0 0 = 0.853333333 cu.m
Zzz = L*B*B/6
ANALYSIS OF FOOTING = 1.066666667 cu.m

S.NO LOAD COMBINATION P (t) P/A (t/sq.m) Mx/Zxx (t/sq.m) Mz/Zzz (t/sq.m) M /Z (t/sq.m) P/A + M /Z (t/sq.m) Check for SBC

1 DL+LL 29.39949 9.187340625 0.202734375 0.159375 0.362109375 9.54945 SAFE


2 DL+WL+X 28.30549 8.845465625 0.17578125 0.69 0.86578125 9.711246875 SAFE
3 DL+WL-X 26.77749 8.367965625 0.25546875 0.3290625 0.58453125 8.952496875 SAFE
4 DL+WL+Z 28.94549 9.045465625 1.72265625 0.105 1.82765625 10.87312188 SAFE
5 DL+WL-Z 26.14049 8.168903125 1.224609375 0.223125 1.447734375 9.6166375 SAFE
6 DL+EQ+X 27.53049 8.603278125 0.214453125 0.1640625 0.378515625 8.98179375 SAFE
7 DL+EQ-X 27.53049 8.603278125 0.214453125 0.1640625 0.378515625 8.98179375 SAFE
8 DL+EQ+Z 27.53049 8.603278125 0.214453125 0.1640625 0.378515625 8.98179375 SAFE
9 DL+EQ-Z 27.53049 8.603278125 0.214453125 0.1640625 0.378515625 8.98179375 SAFE
10 DL+LL+WL+X 30.17449 9.429528125 0.1640625 0.6853125 0.849375 10.27890313 SAFE
11 DL+LL+WL-X 28.64649 8.952028125 0.24375 0.33375 0.5775 9.529528125 SAFE
12 DL+LL+WL+Z 30.81449 9.629528125 1.7109375 0.1003125 1.81125 11.44077813 SAFE
13 DL+LL+WL-Z 28.00949 8.752965625 1.236328125 0.2184375 1.454765625 10.20773125 SAFE
14 DL+LL+EQ+X 29.39949 9.187340625 0.202734375 0.159375 0.362109375 9.54945 SAFE
15 DL+LL+EQ-X 29.39949 9.187340625 0.202734375 0.159375 0.362109375 9.54945 SAFE
16 DL+LL+EQ+Z 29.39949 9.187340625 0.202734375 0.159375 0.362109375 9.54945 SAFE
17 DL+LL+EQ-Z 29.39949 9.187340625 0.202734375 0.159375 0.362109375 9.54945 SAFE

CHECK FOR UPLIFT (when P/A<M/Z)


P ---> self weight of footing+load combination+soil weight
M ---> (Mx+Mz) corresponds to that load combination
3Y ---> 3[(footing width/2)-(M/P)]
Min. Contact area (C.A.) ---> ((footing width-column width)/2)+column width
Condition ---> Min. Contact area (C.A.) should be less than 3Y
CHECK FOR UPLIFT (when P/A<M/Z)
WIDTH SIDE LENGTH SIDE WIDTH SIDE LENGTH SIDE

CHECK FOR
S.NO LOAD COMBINATION P M M/P 3Y MIN CA REMARKS 3Y MIN CA REMARKS BASE PRESSURE BASE PRESSURE
P/A<M /Z
1 DL+LL safe --- --- --- --- --- --- --- --- --- --- ---
2 DL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
3 DL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
4 DL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
5 DL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
6 DL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
7 DL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
8 DL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
9 DL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---
10 DL+LL+WL+X safe --- --- --- --- --- --- --- --- --- --- ---
11 DL+LL+WL-X safe --- --- --- --- --- --- --- --- --- --- ---
12 DL+LL+WL+Z safe --- --- --- --- --- --- --- --- --- --- ---
13 DL+LL+WL-Z safe --- --- --- --- --- --- --- --- --- --- ---
14 DL+LL+EQ+X safe --- --- --- --- --- --- --- --- --- --- ---
15 DL+LL+EQ-X safe --- --- --- --- --- --- --- --- --- --- ---
16 DL+LL+EQ+Z safe --- --- --- --- --- --- --- --- --- --- ---
17 DL+LL+EQ-Z safe --- --- --- --- --- --- --- --- --- --- ---

SLIDING CHECK SLIDING CHECK

LOAD FX FZ LIMITING EQUILIBRIUM ==> 0.9μW=1.5PH


DL -0.26 -0.281 EFFECTIVE FACTOR OF SAFETY AGAINST SLIDING = μW/PH=1.5/0.9=1.66
LL 0.01 0.018 F.O.S =1.66
WL+X -0.415 0.02 WHERE,
WL-X 0.332 -0.021 μ =COEFFICIENT OF FRICTION
WL+Z 0.047 -0.833 W= TOTAL VERTICAL LOAD
WL-Z -0.048 0.72 PH =HORIZONTAL LOAD
EQ+X 0 0
EQ-X 0 0
EQ+Z 0 0
EQ-Z 0 0

ANGLE OF REPOSE OF SOIL( PHI) = 30


FRICTION COEFFICIENT(μ)= TAN (PHI) 0.577

S.NO LOAD COMBINATION FX FZ SLIDING FORCE RESISTING FORCE FACTOR OF SAFETY Check for Sliding

1 DL+LL 0.25 0.263 0.362862233 16.97646485 46.78487679 SAFE


2 DL+WL+X 0.675 0.261 0.723702978 16.34474462 22.58487961 SAFE
3 DL+WL-X 0.072 0.302 0.310464169 15.46241509 49.80418565 SAFE
4 DL+WL+Z 0.213 1.114 1.134180321 16.71430673 14.7369042 SAFE
5 DL+WL-Z 0.308 0.439 0.536269522 15.09458531 28.14738614 SAFE
6 DL+EQ+X 0.26 0.281 0.382832862 15.89722801 41.52524404 SAFE
7 DL+EQ-X 0.26 0.281 0.382832862 15.89722801 41.52524404 SAFE
8 DL+EQ+Z 0.26 0.281 0.382832862 15.89722801 41.52524404 SAFE
9 DL+EQ-Z 0.26 0.281 0.382832862 15.89722801 41.52524404 SAFE
10 DL+LL+WL+X 0.665 0.243 0.708007062 17.42398147 24.60989784 SAFE
11 DL+LL+WL-X 0.082 0.284 0.295601083 16.54165194 55.95937536 SAFE
12 DL+LL+WL+Z 0.203 1.096 1.114641198 17.79354358 15.96347202 SAFE
13 DL+LL+WL-Z 0.298 0.457 0.545575843 16.17382215 29.64541478 SAFE
14 DL+LL+EQ+X 0.25 0.263 0.362862233 16.97646485 46.78487679 SAFE
15 DL+LL+EQ-X 0.25 0.263 0.362862233 16.97646485 46.78487679 SAFE
16 DL+LL+EQ+Z 0.25 0.263 0.362862233 16.97646485 46.78487679 SAFE
17 DL+LL+EQ-Z 0.25 0.263 0.362862233 16.97646485 46.78487679 SAFE
Design Pressure, Pu = 8.14328125 t/sq.m = Max design pressure obtained from above
Safe, no settlement
Depth requirement
Cantilever projection = 0.885 m (Max value considering both sides)
Cantilever B.M (Mu) = 4.783516093 t-m
Required footing depth,d req. = 119.9437975 mm [sqrt(Mu/0.138*fck*1 m width)]
provided depth, D = 450 mm
Effective depth (d) = 394 mm Depth provided is ok

Reinforcement Calculation
Ast required = 283.315282 sq.mm
Ast Minimum = 540 sq.mm
Dia provided = 12 mm
Required spacing = 209.4395102 mm (1 m width*area of one bar/Ast required)
Spacing provided = 150 mm
Ast Provided = 753.9822369 sq.mm Provided steel is ok

Check for one way shear


Shear force, Vu = 5.997526641 t [1.5*(Pu)*(Cantilever projection-d))*1 m width]
Nominal shear stress, Tv = 0.152 N/sq.mm [Vu/(1m width*d)]
Percentage of steel = 0.19136605 %
K= 1 “K” based on thickness of footing if it greater than
permissible shear stress, K*Tc = 0.324 N/sq.mm “300” mm then it is “1”

safe in one way shear


Check for two way shear
pedestal length + d, a = 694 mm
pedestal width + d,b = 624 mm
shear force, Vu = 33.79800479 t [1.5*(Pu)*(L*B-a*b)]
nominal shear stress, Tv = 0.325423892 N/sq.mm [Vu/(2*(a+b)*d)]
βC = 0.766666667 βC = (short side of column / long side of column)
KS = 1 KS = (1+βC) but not greater than “1”
permissible shear stress, KS*Tc = 1.25 N/sq.mm (0.25*sqrt(fck))*KS
safe in two way shear

Top steel calculation


Depth of soil below ground 1.55 [depth of footing below ground- footing height] m
Load 2.79 [unit wt of soil*depth of soil below ground] t/m
Cantilever projection = 0.885 m (Max value considering both sides)
B.M 1.092598875 [load*cantilever projection^2/2] t-m
Ast required = 63.98899992 sq.mm
Dia privided 12 mm
Area of bar 113.04 [3.14*bar dia^2/4] sq.mm
Spacing required 1766.553629 (1 m width*area of one bar/Ast required) mm
Spacing provided 300 mm

Ast Minimum = 270 sq.mm


Min Spacing required 418.6666667 mm
Spacing Provided 300 mm