PETROGAS HELIX
TECHINCAL QUERIES GLOBAL SAMCO ARABIAN BULK DELTA PIPES VALMARK BRANTON IMS GERAB ENSIYAAB JSS PIPES SARSAN
PIPING NATURAL GAS
PIPING
Sample MTC Received Received Received Not received Not received Received Received Not received Not received Received Received Not received Not received Received
signed and stamped TDC. Received Received Received Received Received Received Not received Not received Not received Not received Not received Not received Not received
Quality Manual is
not Received
ISO certificates and Quality manual Received TQ2 Not received Received Not received
with ISO
Not received Not received Not received Not received Not received Not received Not received
9001:2015
Material shall comply with NACE MR-0175 Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply Comply
SSC test Non-Comply TQ2 TQ2 - - TQ1 TQ2 - TQ1 TQ2 - - TQ1
Pressure test value and holding time shall be in line with TDC TQ2 TQ2 - - TQ1 TQ2 - TQ1 TQ2 - - TQ1
Impact test shall be conducted at -13 Deg. C. Vendor to confirm. TQ2 TQ2 - - TQ1 TQ2 - TQ1 TQ2 - - TQ1
Deviation No.2 Stockiest proposal "HIC & SSC not performed by the
manufacturer additional testing will be done at ISO/IEC 17025 by a
certified accreditation body" is not acceptable. Additional test shall be
- - - DEVIATION - - - - - - - - -
considered for HIC if not reported in MTC. However, SSC test shall be
issued by manufacturer only and no additional test is considered.
Hence Stockiest to remove the same from the deviation list.