PORTABLE EQUIPMENT INSPECTION CHECK LIST

WELDING MACHINE
FORM Number :
PHSS
TAG Numbers : CONTRACTOR :
Manufact S.N. : CTR Reps. :
Resp. ENTITY :
Inspection Date :
ELC Inspector : G = Good ; B=Bad ; N/A= Not Applicable
SAF Inspector : CTR check CPY verification
TECHNICAL ASPECT G B N/A G B N/A REMARKS
1 Name Plate
2 Battery system
- Battery's poles
- Battery's pole insulation cover
- Battery's box
- Pos (+) batt's cable shall be RED
- Neg (-) batt's cable shall be BLACK
3 ELC protection
- MCB match with name plate
- ELCB for socket outlet provided (30mA)
4 Degrees protection (IP)
- IP 44 for gen sheltered area
- IP 56 for exposed area
5 Control & Measurement
- Current adjuster
- START-STOP or ON-OFF switch
- Current-Voltage meter
- MNT display : fuel level, temp, oil pressure, etc
- ESD system
6 Welding Generator
- I.R. value of the main winding generator =
- I.R value of the field winding =
- I.R. value of the MCCB =
- Bounding and Grounding Cable installed
7 Welding Terminal
- Pos (+) output terminal
- Neg (-) output terminal
8 Welding Cable
- Tag Number available (write it down)
- Cable condition ( outer sheath, connector & size )
- Cable I.R. value =
9 GROUNDING system
- Grounding cable for receptacles
- Grounding cable for external (min 35 mm 2)
- Grounding ROD availability and condition
10 Receptacles condition and I.R. value =
11 Electrode Holder condition
12 MECHANICAL PART
- Engine and fuel system leaks
- Battery condition
- Engine Package.
- Fan Belt
- Oil.air,& cooling system condition

SAFETY ASPECT
1 Engine skid Condition
2 Flame arrester
3 Exhaust Insulation
4 Rotating Guard
5 Lifting Points (Pad Eyes)
6 ESD system
- ESD pushbutton
- Air intake shut off valve provided
7 Wheel (if required)
8 Fuel tank cover/plug
9 Air cooling system
10 Fire Extinguisher

CONCLUSIONs :
Base on the inspection result this Welding machine is FIT/UNFIT to be used in PHM Area (*"coret yg tak perlu")

Note : This equipment is for HAZARDOUS/NON Hazardous Area (*"coret yg tak perlu")

This inspection results is valid until ……………………………………………………………


Re-inspection shall be done after reach validity date or tools after repaired

ROLE