You are on page 1of 1

PAGE NO.

: 1 OF 1
DIMENSION INSPECTION RECORD REPORT NO. : PL-6025-1-DI-00
FOR SHELL LENGTH DATE : 15 January 2018

PROJECT NAME : BUC PUMP RELOCATE ITEM NO. : STRAINER

CLIENT : BANGCHAK CORPORATION PUBLIC.CO.,LTD. DRAWING NO./REV. : N/A

PROJECT NO. : 6025-1 DESIGN CODE : ASME SEC.VIII

The Sketch Part

Orientation 0° 90° 180° 270°

Check Point A B C D

Drawing 731 731 731 731


Tolerance ±6 ±6 ±6 ±6
Actual Check 735 735 735 735
Division +4 +4 +4 +4
Result Acc Acc Acc Acc

Maesuring and/or Testing Equipment


Used/Serial No.:
1.) STEEL TAP 5 M.
2.)

RECORDED BY PILIN QC ENGINEER/APPROVED/BY PILIN REVEWED/WITNESSED/BY KESSEL

NAME / SIGN /DATE NAME / SIGN /DATE NAME / SIGN /DATE