You are on page 1of 25

ENGINEERING UTILITIES 2

Sanitary Drainage
System
GROUP 2
ARCHITECTURE PRESENTATION

Introduction
Sanitary and Drainage System is a system of piping
within public or private premises that conveys
sewage or other liquid waste to an approved point
of disposal. The intents is to design and stall
sanitary drainage system that will function reliably,
are neither undersized nor oversized, and are
constructed from materials, fittings and
connections whose quality is regulated by codes
and standards.
BASIC PRINCIPLES OF SANITARY
AND DRAINAGE SYSTEM
Sanitary drainage
systems developed in a Supply of Prevention of
building collect all the
human waste and water dampness
wastewater generated
from any sanitary and Treatment of Orientation of
hygienic activities, which waste building
is conveyed by water
through drainage piping
Collection and Space
as a medium and
ultimately to an approved conveyance planning
disposal point.
Public Health and Safety
To maintain such an environment that not affect the public
health in general

Environmental Protection
Objectives The creation of such conditions of living which will not result
into serious outbreak of epidemic diseases.

Sustainable Development
It is the control of environmental pollution, improve
environmental quality to enable healthy ecosystem and
comfortable habitation to human.
Parts and details of Sanitary
and drainage system

Pitch or Slope Sizing Branch Interval Stacks and


offsets
Drains must be pitched to Sizing charts are based Branch interval is a
maintain a velocity of 2 feet on this maximum flow. distance along a soil or
per second or greater. The A stack is the main
When sizing horizontal waste stack
minimum velocity is designed vertical pipe that
branch, determine the corresponding to a
to keep the solids in carries away
number of fixture units. story height, but not
suspension. The minimum discharge from
Determine the fixture less than 8 feet, within
pitch is ¼ inch per foot (2 water closets and
drain size based on trap the horizontal
percent) for sizes 1-½-inch urinals or other
size. Establish the branches from one
and 2-inch drains, and 1/8 clear water waste
minimum pipe size. floor or story of a
inch per foot (1 percent) for from equipment
structure are
larger drains. and no sanitary
connected to the
fixtures.
stack.
Flow in Building Drains

Flow enters the horizontal drain at a relatively high

Flow in velocity compared to the velocity in a horizontal drain


under uniform flow conditions.
Stacks and
offsets Flow in fixture Drains

Determination ofthe required drain size is a relatively


simple matter, snce the fixture drain must be adequate
only to carry the discharges from the fixture to which it is
attached
Basic Diagram of
Sanitary and
Drainage system
Sumps and Ejectors
The distinction between sump and ejector pump is more
terminology than actual fact. A sump pump is designed to

Components
transport clear, non-sanitary wastewater with turbidity and
suspended solids no larger than sand grains. Ejectors are designed

of Sanitary
to transport sanitary waste and larger solids suspended in the
effluent.

Drainage
system Cleanouts

A cleanout provides access to horizontal and vertical lines to


facilitate and provide means of removing obstruction such as
solids objects, greasy wastes, and hair.
Floor drains and Floor sinks
Floor drains are connected to a trap that can be readily cleaned
and sized to efficiently serve the purpose for which it is intended

Components
of Sanitary
Flashing Ring

Drainage This component makes an effective seal, which prevents water


from passing around the drain to the area below.

system
Sediment Bucket
It is an additional internal strainer designed to collect debris that
gets by the regular strainer. It is required whenever the drain can
receive solids, trash,, or grit that could plug piping.
Grates/Strainers

The selection of grates is based on use and the amount of flow.

Components Grates and strainers should secured with stainless steel screw in
nickle-bronze tops.

of Sanitary
Drainage Accessories

system Accessories are available to make the basic drain adaptable to


various types of structure.
Blackwater Valves

It can be installed on a building sewer/house drain when the drain

Components is lower than the sewer line, sewer discharges may occur due to
combined storm water.

of Sanitary
Drainage Oil Interceptors

system Are designed to separate and collect oils and other light-density,
volatile liquids, which would otherwise be discharged into the
drainage system.
Fixture wastewater type

This device are mounted on the trap of frequently used fixtures.

Components
of Sanitary Supports

Drainage The location of pipe supports usually is specified by code. They ae

system located to maintain a slope that is as uniform as possible and will


not change with time.
SUMP EJECTOR CLEANOUT
FLOOR DRAINS AND
FLOOR SINKS

GRATE/STRAINER
FLASHING RING SEDIMENT BUCKET
ACCESSORIES BACKWATER VALVE
OIL INTERCEPTOR
ENGINEERING UTILITIES 2

BUILDING CODES OF
THE PHILIPPINES
IMPLEMENTED IN
SANITARY
DRAINAGE SYSTEM
Members:
ALAMO, Khim
ASIS, Russell Joshua
BIO, Aeron Pyrce
BRUN, Marcus Steven
COPER, Anthony
ECAL, Jerome
FERRERAS, Maria Patricia
IPORAC, Dean Scott

Thank
IRESO, Kyla May
MARJALINO, Lhe- Anne
PEÑAFLOR, Czares

you!
PISPIS, Tristan Levi
QUITASOL, Jasonel

You might also like