You are on page 1of 14

CRITICAL DEVICE FUNCTION TEST REPORT (CDFT)

1.0 - WELL INFO

FIELD : D18 SS WELL STATUS LS


PLATFORM : D18MP-A SHUT-IN
WELLLHEAD TYPE : SOLOR ALERT Size: 4 1/16" PRODUCING
WELLLHEAD RATING: 10K S/N: 0829/ZHS/14T/1-2 X INJECTING
TAG NUMBER : D18-104TS OTHER
TESTER: M.FAUZI/DEVID LING SHUT IN TIME: 11:30 HOURS
DATE : 17 MONTH : 1 YEAR 2023
Remarks : N/A

SS WELL TYPE LS TYPE PRESSURE(psig) TREE CAP CONNECTION


NATURAL FTHP 1110 BOWEN
GAS LIFTED Initial Pressure Top Up Pressure NON STANDARD BOWEN X
SITHP
X WATER INJECTOR 306 N/A OTIS
GAS INJECTOR Section A 0 MCEVOY
OTHER Section B 0 OTHERS
Section C 0
PROD / INJECTION RATE (bbl/d): N/A Section D NOT EXIST
HEADER 306 TREE CAP CONDITION : GOOD / NO VISIBLE

PERFORMED BY VERIFIED BY APPROVED BY


NAME DEVID LING MOHAMAD FAUZI
DESIGNATION TECHNICIAN TEAM LEADER SOR/OS/OIM

SIGNATURE

DATE 17/Jan/2023 17/Jan/2023 17/Jan/2023

CDFT REV.4 2020


D18-104TS
2.0 - X-MAS TREE FUNCTION TEST 17/Jan/2023

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the KILL WING VALVE (KWV) Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the WING VALVE (WV) Size: 4 1/16 inch Fully Open: 24 turns
Rating: 10 000 psig Fully Close: 24 turns
Valve Type: X MANUAL AUTOMATED OEM: SOLAR

"applicable for automated valve only"


Actuator model: N/A Actuator Piston Rising Type: YES X NO
Actuator Type: N/A Opening: - sec Closing: - sec
Piston Travel Lengh Open: - CM
Piston Travel Lengh Closed: - CM

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 4 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the CROWN VALVE (CV) Size: 4 1/16 inch Fully Open: 24 turns
Rating: 10 000 psig Fully Close: 24 turns
OEM: SOLAR

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE , COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DECSO 422


Sealant / Lubricant: 4 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the SURFACE SAFETY VALVE (SSV) Size: 4 1/16' inch Fully Open: N/A turns
Rating: 10 000 psig Fully Close: N/A turns
Valve Type: MANUAL X AUTOMATED OEM: SOLAR

"applicable for automated valve only"


Actuator model: HARLIBURTON Actuator Piston Rising Type: X YES N/A NO
Actuator Type: HYDRAULIC Opening: 28 sec Closing: 26 sec
Piston Travel Lengh Open: 0.3 cm
Piston Travel Lengh Closed: 10..2 cm

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 4 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the LOWER MASTER VALVE (LMV) Size: 4 1/16' inch Fully Open: 24 turns
Rating: 10 000 psig Fully Close: 24 turns
OEM: SOLAR

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 4 Lbs
D18-104TS
3.0 - SCSSV FUNCTION & Control / MTM Line Test 17/Jan/2023

CONTROL LINE & VOID / MTM TEST

Hydraulic Condition : CLEAR


BPM Installed : NO If Yes, Record BPM pressure: NO psig
Hydraulic Return Volume : 120 ml
Control Line Cycling Test : 5 times
Control Line Pressure Up : 5000 psig
Flow tube Movement : 3600 psig
Control Line maintain injected pressure : X YES NO
If NO,Pumping away rate : NO stroke/min
Type of leak, it is one way leak or two way leak ?: One Way Two Way

Void Area Test (ADAPTER) : X YES NO Void Area Test (HANGER) : X YES NO
Remarks : AFTER MONITOR FOR 30 MIN, ZERO psig Remarks : AFTER MONITOR FOR 30 MIN, ZERO psig

MTM Area Test (ADAPTER) : X YES NO MTM Area Test (HANGER): X YES NO
Remarks : AFTER MONITOR FOR 30 MIN, ZERO psig Remarks : AFTER MONITOR FOR 30 MIN, ZERO psig

SCSSV FUNCTION TEST

X TR-SCSSV BPV Production Header


YES Pressure on tubing is being
Type of WR-SCSSV Type of TWCV Closed Drain
Slam Test: bleed off to:
SCSSV : Storm Choke Plug : SRP PLUG Other :
NO
Other X Wireline Plug
Holding : YES NO

Shut-in the wing valve and record the following pressure. : Initial Pressure Top Up Pressure

306 N/A

SECTION A SECTION B SECTION C SECTION D CONTROL LINE


TIME AFTER SHUT IN TUBING PRESSURE (psig)
(psig) (psig) (psig) (psig) (psig)
0 MIN 0 0 0 0 N/A 0
15 MIN 0 0 0 0 N/A 0
30 MIN 0 0 0 0 N/A 0
45 MIN 0 0 0 0 N/A 0
60 MIN 0 0 0 0 N/A 0
Leak rate @15min 0
**Equalize the pressure across SCSSV. Open SCSSV by applying '1500 psig + SITHP' on control line. Monitor control line pressure for 15 mins.

REMARKS : SCSSV HOLDING PRESSURE

Final well status : Shut-in X Injecting Producing


D18-104TS
4.0 - WELLHEAD FUNCTION TEST 17/Jan/2023

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the SECTION A1 Size: 2 1/16 inch Fully Open: 13 turns
Rating: 5000 psig Fully Close: 13 turns
OEM: SOLAR

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 2 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test SECTION B1 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 5000 psig Fully Close: 18 1/2 turns
OEM: WKM

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE,COMPLETED FLUSHED AND GREASING

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 3 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test SECTION C1 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 10 000 psig Fully Close: 18 1/2 turns
OEM: CAM FL

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE,COMPLETED FLUSHED AND GREASING

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 4 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION D1 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs
D18-104TS
4.1 - WELLHEAD FUNCTION TEST 17/Jan/2023

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION A2 Size: 2 1/16 inch Fully Open: 13 turns
Rating: 5000 psig Fully Close: 13 turns
OEM: SOLAR

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE, COMPLETED FLUSHED AND GREASING

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 2 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test SECTION B2 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 5000 psig Fully Close: 18 1/2 turns
OEM: WKM

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE,COMPLETED FLUSHED AND GREASING

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 3 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test SECTION C2 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 5000 psig Fully Close: 18 1/2 turns
OEM: CAM FL

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE,COMPLETED FLUSHED AND GREASING

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 3 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION D2 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs
D18-104TS
4.2 - WELLHEAD FUNCTION TEST 17/Jan/2023

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the SECTION A3 Size: 2 1/16" inch Fully Open: 13 turns
Rating: 5000 psig Fully Close: 13 turns
OEM: SOLAR

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 2 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test SECTION B3 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 5000 psig Fully Close: 18 1/2 turns
OEM: CAM FL

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 3 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test SECTION C3 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 5000 psig Fully Close: 18 1/2 turns
OEM: CAM FL

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING PRESSURE, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 3 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION D3 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs
D18-104TS
4.2 - WELLHEAD FUNCTION TEST 17/Jan/2023

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test the SECTION A4 Size: 2 1/16" inch Fully Open: 13 turns
Rating: 5000 psig Fully Close: 13 turns
OEM: SOLAR

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) 0 0 0 0 0 Pressure(psig) 0 0 0 0 0

Remarks: HOLDING, COMPLETED FLUSHED AND GREASED

Valve Flush: 1 Liter Sealant type: DESCO 422


Sealant / Lubricant: 2 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
X To test SECTION B4 Size: 3 1/8 inch Fully Open: 18 1/2 turns
Rating: 5000 psig Fully Close: 18 1/2 turns
OEM: WKM

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test SECTION C4 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION D4 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs
D18-104TS
4.3 - WELLHEAD FUNCTION TEST 1/17/2023

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION A4 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A 0 0 0 N/A Pressure(psig) N/A 0 0 0 N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test SECTION B4 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A 0 0 0 N/A Pressure(psig) N/A 0 0 0 N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: 2 Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test SECTION C4 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A 0 0 0 N/A Pressure(psig) N/A 0 0 0 N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs

Tick the appropriate valve(s) to be tested : "valve info" "applicable for manual valve only"
N/A To test the SECTION D4 Size: N/A inch Fully Open: N/A turns
Rating: N/A psig Fully Close: N/A turns
OEM: N/A

BEFORE AFTER
Time (min) 0 1 5 10 LEAK RATE Time (min) 0 1 5 10 LEAK RATE
Pressure(psig) N/A N/A N/A N/A N/A Pressure(psig) N/A N/A N/A N/A N/A

Remarks: N/A

Valve Flush: N/A Liter Sealant type: N/A


Sealant / Lubricant: N/A Lbs
D18-104TS
5.0 - ANNULUS PRESSURE REPORT 17/Jan/2023

PERFORM BLEED OFF TEST


SECTION A (psig) SECTION B (psig) SECTION C (psig) SECTION D (psig) CONTROL LINE PRESSURE
TIME THP (psig)
Start Time :16:00 Start Time : Start Time : Start Time : (psig)

SS LS
# 00 Min 0 0 0 N/A 306 N/A 5,000
# 15 Min 0 0 0 N/A 306 N/A 5,000
# 30 Min 0 0 0 N/A 306 N/A 5,000
# 45 Min 0 0 0 N/A 306 N/A 5,000
# 60 Min 0 0 0 N/A 306 N/A 5,000
# 4 Hrs

REMARKS : BLEED OFF SECTION A (NO PRESSURE)

PERFORM BUILD UP TEST


SECTION A (psig) SECTION B (psig) SECTION C (psig) SECTION D (psig) CONTROL LINE PRESSURE
TIME THP (psig)
Start Time :16:00 Start Time : Start Time : Start Time : (psig)

SS LS
# 00 Min 0 0 0 N/A 306 N/A 5,000
# 15 Min 0 0 0 N/A 306 N/A 5,000
# 30 Min 0 0 0 N/A 306 N/A 5,000
# 45 Min 0 0 0 N/A 306 N/A 5,000
# 60 Min 0 0 0 N/A 306 N/A 5,000
# 4 Hrs

REMARKS : NO BLUID UP PRESSURE

6.0 - WELLHEAD SUBSIDENCE MONITORING REPORT

ANNULUS SECTION

Wellhead Subsidence
"Annulus A" : 186 cm "Annulus A" : DegC
Monitoring

Datum Point #

"Annulus B" : 128 cm "Annulus B" : DegC

"Annulus C" : 76 cm "Annulus C" : DegC

A annulus
Datum "Annulus D" : NOT EXIST cm "Annulus D" : DegC
Point #3
*Taken with temperature gun
B
Annulus
Datum
Point #2
C Remarks : COMPLETED MEASURING HEIGHT OF DATUM POINT #1, #2 ,#3 & #4
Annulus
Datum
Point #1

Production Deck

7.0 - CASING MONITORING

Casing Condition: X NORMAL ABNORMAL

Remarks: GOOD CONDITION. NO LEAKED

* Pour soapy water on top of conductor and monitor for sign of bubbles / Snoopy Test
* Focus on loss in thickness of casing. E.g. cavity between surface casing and conductor
* Find a reference point (Horizontal & Vertical Axis) to take picture so visually can determine subsidence/abnormalities
9.0 - SOLAR ALERT SDN BHD (Co. No. 338255-M)
(TREE & WELLHEAD PICTURE REPORT)
CLIENT : PETRONAS CARIGALI SDN BHD JOB NO: TBA
PROCESS : XMASS TREE & WELLHEAD PAGE : 1 OF 1

EQUIPMENT : D18-104TS DATE : 17/Jan/2023

PICTURE 1 : X-MASS TREE PICTURE 2 : WV PICTURE

PICTURE 3 : SSV PICTURE 4 : ANNULUS picture

N/A

PICTURE 5 : HYDRAULIC RETURN PICTURE 6 : KILL WING VALVE


10.0 - SOLAR ALERT SDN BHD (Co. No. 338255-M)
(CASING PICTURE REPORT)
CLIENT : PETRONAS CARIGALI SDN BHD JOB NO: TBA
PROCESS : CONDUCTOR CASING LEAK TEST PAGE : 1 OF 1

EQUIPMENT : D18-104TS DATE : 17/Jan/2023

PICTURE 1 : 0° - 90° PICTURE 2 : 90° - 180°

PICTURE 3 : 180° - 270° PICTURE 4 : 270° - 360°

N/A N/A

PICTURE 5 : PICTURE 6 :
8.0 - SOLAR ALERT SDN BHD (Co. No. 338255-M)
(DPG GRAPH PICTURE REPORT)
CLIENT : PETRONAS CARIGALI SDN BHD JOB NO:
PROCESS : DPG GRAPH PAGE : 1 OF 1

EQUIPMENT : D18-104TS DATE : 17/Jan/2023

N/A N/A

WV CV

N/A N/A

SSV LMV

N/A

CONTROL LINE SCSSV


8.0 - SOLAR ALERT SDN BHD (Co. No. 338255-M)
(DPG GRAPH PICTURE REPORT)
CLIENT : PETRONAS CARIGALI SDN BHD JOB NO: TBA
PROCESS : DPG GRAPH PAGE : 1 OF 1

EQUIPMENT : D18-104TS DATE : 1/17/2023

N/A N/A

N/A N/A

N/A N/A

N/A N/A

N/A N/A

N/A N/A
8.1 - SOLAR ALERT SDN BHD (Co. No. 338255-M)
(DPG GRAPH PICTURE REPORT)
CLIENT : PETRONAS CARIGALI SDN BHD JOB NO: XXXXXXXX
PROCESS : DPG GRAPH PAGE : 1 OF 1

EQUIPMENT : D18-104TS DATE : 1/17/2023

N/A N/A

N/A N/A

N/A N/A

SSV LMV