PLUMBING NOTES

700 1. ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE EXECUTED ACCORDING TO THE
200 500 PROVISIONS OF THE PHILIPPINE PLUMBING CODE, THE NATIONAL BUILDING CODE AND
500 600 THE RULES AND REGULATION OF DUMAGUETE CITY.
300 400
2. COORDINATE THE DRAWING WITH OTHER RELATED DRAWINGS AND SPECIFICATIONS

200
THE ENGINEER SHALL BE NOTIFIED OF ANY DISCRIPANCY FOUND THEREIN.

INLET OUTLET SPACED @ 200mm OC BW 3. ALL PIPES SHALL BE INSTALLED AS INDICATED ANY RELOCATIONS REQUIRED FOR THE
INLET OUTLET
500
300
PROPER EXECUTION OF OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE

700
600

400
ARCHITECT.

500
4. PROPOSED SANITARY UTILITIES SHALL SHALL CONFORM TO THE ACTUAL LOCATION
DEPTH AND INVERT ELEVATION OF ALL EXISTING PIPES AND STRUTURES AS VERIFIED
STIRRUPS SPACED @ 150 BY THE CONTRUCTOR.
PLAN PLAN 3-100mm, 3-100mm, & 200mm
500 600
PLAN 5. ALL SEWER LINES SHOULD BE POLYVINYL CHLORIDE (PVC) PIPES CLASS DWV.

250
300 400 HOOPS SPACED @ 3-100mm, 6. ALL SLOPES FOR HORIZONTAL DRAINAGE SHALL MAINTAIN 1% MINIMUM SLOPE UNLESS
3-150mm, REST @ 200mm OC OTHERWISE SPECIFIED.

50
50

7. SIZE OF WATER SUPPLY PIPES TO FIXTURE SHALL BE IN ACCORDANCE WITH THE


PVCN PIPE PVCN PIPE MANUFACTURERS INSTRUCTIONS.

8. ALL DOWN SPOUTS SHJALL PVC PIPES, UNLESS OTHERWISE SPECIFIED.


INLET OUTLET
500
400

500
400
INLET OUTLET
9. THE CONTRUTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND COORDINATE THIS
SEPTIC BEAM DETAIL WORK WITH THE SEWER LINE CONNECTING POINT.

SCALE 1:20 10. ALL PIPES ARE IN MILLIMETERS AND ALL DIMENSIONS IN MILLIMETERS UNLESS

200
50
50

OTHERWISE SPECIFIED.
SECTION SECTION
CATCH BASIN AND GREASE TRAP DETAIL SECTION 4530
SCALE 1:20
200 1425 200 2505 200

SEPTIC COLUMN FOOTING DETAIL


SCALE 1:20

200
CF CF CF
PLUMBING LEGEND FD FLOOR DRAIN
WC WATER CLOSET CO

KS KITCHEN SINK 500x500 500x500 500x500 500x500


SEPTIC WATER SUPPLY LINE
TANK CO CLEAN OUT MANHOLE MANHOLE MANHOLE MANHOLE
SHO SHOWER
ST SEPTIC TANK
LAV LAVATORY
WM WATER METER

1800
1400
SH WCT UR URINAL
GT FD
FD WC
WC
GV GATE VALVE
CB CATCH BASIN
LAV
CO SH WCT F CV CHECK VALVE
WH WATER HEATER
V VENT
FD R RISER CO
GT
TO CANAL
BV BRANCH VENT
LAV HB HOSE BIBB
F VTR VENT THRU ROOF INLET
F FAUCET
GT GREASE TRAP

200
SS SOIL STACK CF CF CF
TO CANAL
DS DOWN SPOUT
WS WASTE STACK
RD ROOF DRAIN INLET
PLAN
SD STORM DRAIN @ 200mm OC BOTHWAYS
@ 200mm OC BOTHWAYS PLAN 100 100
150 1500 150 825 805 750 150
500 500 500 500

RC COVER RC COVER RC COVER RC COVER

CO MANHOLE CO MANHOLE CO MANHOLE MANHOLE

250
SINK
F
BM BM BM

300
AIR SPACE
GT

1850
TO CANAL

1400

1250

1200

1150
SPACE @ 600mm
6" THK CHB
TO WATER SUPPLY

@330mm OC BOTHWAYS
10% SLOPE
CV
M

200
GV

SECTION
PLUMBING LAYOUT PLUMBING ISOMETRIC @ 200mm OC BOTHWAYS SEPTIC TANK DETAIL
SCALE NTS SCALE 1:20
SCALE 1:100 MTS

FROM THE OFFICE OF: MASTER PLUMBER: PROJECT TITLE APPROVED BY OWNER: SHEET CONTENT
PRC NO. : IAPOA NO.:

VALIDITY : VALIDITY : PROPOSED RESIDENTIAL 1


PTR NO. : TIN NO. : BUILDING P
DATE : PLACE : LOCATION: ADDRESS: CAD BY: ROLAND A.