SAFETY TECHNICAL SERVICES AND INSPECTIONS

Casing & Tubing Inspection Summary Report

Customer : GULF ENERGY Job No : 51073 Date : 27-APR-2023

Rig No : KDC - 48 Location : SAHMAH PIPE YARD Well NO: NA

Size : 13-3/8" Grade : T95-1 Conn : TSH-ER

Weight : 72 PPF Range : R3 Drift Dia : 12.250"

Total Qty : 98 Spec: API 5A5, 5CT Report No: 51073-CSG-001

a) External Mechanical Cleaning : NA

b) External Water Blast Cleaning : NA

c) Internal Water Blast Cleaning : NA

d) Full Body Visual Insp & API Drifting : X

e) Visual Thread Inspection : X

f) Full Length EMI : NA

g) Clean And Redope X

Inspection Result
Trend Chart
Qty Percentage
100 94
Total Accepted : 94 95.92% Total Accepted :
90
Bent : 0 0.00% 80
Bent :
70
Damaged Box : 1 1.02% 60
Damaged Box :
50
Damaged Pin : 3 3.06%
40
Damaged Pin :
Damaged Box & Pin: 0 0.00% 30
20
Drift Failed : 0 0.00% Damaged Box &
10 1 3 Pin:
0 0 0
0 Drift Failed :
1
COMMENTS :
13-3/8" CASING INSPECTION SUMMARY & REPORT'S.

Approved : Inspector : SYAMKUMAR

PO Box:3288 Airport Heights, PC. 111, Muscat, Sultanate of Oman F-TUB-01 Rev-0
SAFETY TECHNICAL SERVICES AND INSPECTIONS

Used Casing and Tubing Inspection Tally Sheet


Date : April-27-2023
Customer : GULF ENERGY Report No: 51073-CSG-001-1
Rig No : KDC-48 Job No : 51073 Location : SAHMAH ( HCF PIPE YARD)
Size : 13-3/8" Grade : T95-1 Conn : TSH-ER
Weight : 72 PPF Range : R-3 Drift Dia : 12.250"
Ref Specifications/ Procedure : API 5A5, 5CT, 5B Make Up Loss: N/A
Condition Tally Length Full Body
Serial No. FLD Remarks
Box Pin (FT ) EMI
1 OK OK OK 39.38 N/A ACCEPTED
2 OK OK OK 39.04 N/A ACCEPTED
3 OK OK OK 37.51 N/A ACCEPTED
4 OK OK OK 39.54 N/A ACCEPTED
5 OK OK OK 36.76 N/A ACCEPTED
6 OK OK OK 35.34 N/A ACCEPTED
7 OK OK OK 38.54 N/A ACCEPTED
8 OK OK OK 37.76 N/A ACCEPTED
9 OK OK OK 36.68 N/A ACCEPTED
10 OK OK OK 36.60 N/A ACCEPTED
11 OK OK OK 36.60 N/A ACCEPTED
12 OK OK OK 36.36 N/A ACCEPTED
13 OK OK OK 37.70 N/A ACCEPTED
14 OK OK OK 38.16 N/A ACCEPTED
15 OK OK OK 36.44 N/A ACCEPTED
16 OK OK OK 36.84 N/A ACCEPTED
17 OK OK OK 38.24 N/A ACCEPTED
18 OK OK OK 37.24 N/A ACCEPTED
20 OK OK OK 37.76 N/A ACCEPTED
22 OK OK OK 35.44 N/A ACCEPTED
23 OK OK OK 38.26 N/A ACCEPTED
24 OK OK OK 38.00 N/A ACCEPTED
25 OK OK OK 36.84 N/A ACCEPTED
26 OK OK OK 38.56 N/A ACCEPTED
27 OK OK OK 36.50 N/A ACCEPTED
28 OK OK OK 37.42 N/A ACCEPTED
29 OK OK OK 35.52 N/A ACCEPTED
30 OK OK OK 38.06 N/A ACCEPTED
31 OK OK OK 36.74 N/A ACCEPTED
32 OK OK OK 39.48 N/A ACCEPTED

Note :
ABBREVIATIONS USED IN THIS SHEET:
SD – SEAL DAMAGE TD – THREAD DAMAGE Inspector :
CS - CORRODED SEAL PT - PITTED THREADS
BM - BODY MASHED DNP - DRIFT NOT PASSED SYAMKUMAR

PO Box:3288 Airport Heights, PC. 111, Muscat, Sultanate of Oman F-TUB-03 Rev-0
SAFETY TECHNICAL SERVICES AND INSPECTIONS

Used Casing and Tubing Inspection Tally Sheet


Date : April-27-2023
Customer : GULF ENERGY Report No: 51073-CSG-001-2
Rig No : KDC-48 Job No : 51073 Location : SAHMAH ( HCF PIPE YARD)
Size : 13-3/8" Grade : T95-1 Conn : TSH-ER
Weight : 72 PPF Range : R-3 Drift Dia : 12.250"
Ref Specifications/ Procedure : API 5A5, 5CT, 5B Make Up Loss: N/A
Condition Tally Length Full Body
Serial No. FLD Remarks
Box Pin (FT ) EMI
33 OK OK OK 38.87 N/A ACCEPTED
34 OK OK OK 36.64 N/A ACCEPTED
35 OK OK OK 38.22 N/A ACCEPTED
36 OK OK OK 36.66 N/A ACCEPTED
37 OK OK OK 37.36 N/A ACCEPTED
38 OK OK OK 38.20 N/A ACCEPTED
39 OK OK OK 38.52 N/A ACCEPTED
40 OK OK OK 38.52 N/A ACCEPTED
41 OK OK OK 37.32 N/A ACCEPTED
42 OK OK OK 35.36 N/A ACCEPTED
43 OK OK OK 38.20 N/A ACCEPTED
44 OK OK OK 38.56 N/A ACCEPTED
45 OK OK OK 37.80 N/A ACCEPTED
46 OK OK OK 38.31 N/A ACCEPTED
47 OK OK OK 36.74 N/A ACCEPTED
48 OK OK OK 38.06 N/A ACCEPTED
49 OK OK OK 38.28 N/A ACCEPTED
50 OK OK OK 38.64 N/A ACCEPTED
51 OK OK OK 38.60 N/A ACCEPTED
52 OK OK OK 38.44 N/A ACCEPTED
53 OK OK OK 35.50 N/A ACCEPTED
54 OK OK OK 38.40 N/A ACCEPTED
55 OK OK OK 37.80 N/A ACCEPTED
56 OK OK OK 36.72 N/A ACCEPTED
57 OK OK OK 34.88 N/A ACCEPTED
58 OK OK OK 34.52 N/A ACCEPTED
59 OK OK OK 36.40 N/A ACCEPTED
60 OK OK OK 38.55 N/A ACCEPTED
61 OK OK OK 37.18 N/A ACCEPTED
62 OK OK OK 38.56 N/A ACCEPTED

Note :
ABBREVIATIONS USED IN THIS SHEET:
SD – SEAL DAMAGE TD – THREAD DAMAGE Inspector :
CS - CORRODED SEAL PT - PITTED THREADS
BM - BODY MASHED DNP - DRIFT NOT PASSED SYAMKUMAR

PO Box:3288 Airport Heights, PC. 111, Muscat, Sultanate of Oman F-TUB-03 Rev-0
SAFETY TECHNICAL SERVICES AND INSPECTIONS

Used Casing and Tubing Inspection Tally Sheet


Date : April-27-2023
Customer : GULF ENERGY Report No: 51073-CSG-001-3
Rig No : KDC-48 Job No : 51073 Location : SAHMAH ( HCF PIPE YARD)
Size : 13-3/8" Grade : T95-1 Conn : TSH-ER
Weight : 72 PPF Range : R-3 Drift Dia : 12.250"
Ref Specifications/ Procedure : API 5A5, 5CT, 5B Make Up Loss: N/A
Condition Tally Length Full Body
Serial No. FLD Remarks
Box Pin (FT ) EMI
63 OK OK OK 37.50 N/A ACCEPTED
64 OK OK OK 38.16 N/A ACCEPTED
65 OK OK OK 37.92 N/A ACCEPTED
66 OK OK OK 37.04 N/A ACCEPTED
67 OK OK OK 37.94 N/A ACCEPTED
68 OK OK OK 38.00 N/A ACCEPTED
69 OK OK OK 38.10 N/A ACCEPTED
70 OK OK OK 36.14 N/A ACCEPTED
73 OK OK OK 38.12 N/A ACCEPTED
74 OK OK OK 37.18 N/A ACCEPTED
75 OK OK OK 37.33 N/A ACCEPTED
76 OK OK OK 38.06 N/A ACCEPTED
77 OK OK OK 38.22 N/A ACCEPTED
78 OK OK OK 37.76 N/A ACCEPTED
79 OK OK OK 37.00 N/A ACCEPTED
80 OK OK OK 38.16 N/A ACCEPTED
81 OK OK OK 37.36 N/A ACCEPTED
82 OK OK OK 38.34 N/A ACCEPTED
83 OK OK OK 38.37 N/A ACCEPTED
84 OK OK OK 38.22 N/A ACCEPTED
85 OK OK OK 36.88 N/A ACCEPTED
86 OK OK OK 37.16 N/A ACCEPTED
87 OK OK OK 37.66 N/A ACCEPTED
88 OK OK OK 36.90 N/A ACCEPTED
89 OK OK OK 37.88 N/A ACCEPTED
90 OK OK OK 37.12 N/A ACCEPTED
91 OK OK OK 38.18 N/A ACCEPTED
92 OK OK OK 38.08 N/A ACCEPTED
93 OK OK OK 38.24 N/A ACCEPTED
94 OK OK OK 38.16 N/A ACCEPTED

Note :
ABBREVIATIONS USED IN THIS SHEET:
SD – SEAL DAMAGE TD – THREAD DAMAGE Inspector :
CS - CORRODED SEAL PT - PITTED THREADS
BM - BODY MASHED DNP - DRIFT NOT PASSED SYAMKUMAR

PO Box:3288 Airport Heights, PC. 111, Muscat, Sultanate of Oman F-TUB-03 Rev-0
SAFETY TECHNICAL SERVICES AND INSPECTIONS

Used Casing and Tubing Inspection Tally Sheet


Date : April-27-2023
Customer : GULF ENERGY Report No: 51073-CSG-001-4
Rig No : KDC-48 Job No : 51073 Location : SAHMAH ( HCF PIPE YARD)
Size : 13-3/8" Grade : T95-1 Conn : TSH-ER
Weight : 72 PPF Range : R-3 Drift Dia : 12.250"
Ref Specifications/ Procedure : API 5A5, 5CT, 5B Make Up Loss: N/A
Condition Tally Length Full Body
Serial No. FLD Remarks
Box Pin (FT ) EMI
95 OK OK OK 36.68 N/A ACCEPTED
96 OK OK OK 38.08 N/A ACCEPTED
97 OK OK OK 38.16 N/A ACCEPTED
98 OK OK OK 37.72 N/A ACCEPTED

Note :
ABBREVIATIONS USED IN THIS SHEET:
SD – SEAL DAMAGE TD – THREAD DAMAGE Inspector :
CS - CORRODED SEAL PT - PITTED THREADS
BM - BODY MASHED DNP - DRIFT NOT PASSED SYAMKUMAR

PO Box:3288 Airport Heights, PC. 111, Muscat, Sultanate of Oman F-TUB-03 Rev-0
SAFETY TECHNICAL SERVICES AND INSPECTIONS

Used Casing and Tubing Inspection Tally Sheet


Date : April-27-2023
Customer : GULF ENERGY Report No: 51073-CSG-001-5
Rig No : KDC-48 Job No : 51073 Location : SAHMAH ( HCF PIPE YARD)
Size : 13-3/8" Grade : T95-1 Conn : TSH-ER
Weight : 72 PPF Range : R-3 Drift Dia : 12.250"
Ref Specifications/ Procedure : API 5A5, 5CT, 5B Make Up Loss: N/A
Condition Tally Length Full Body
Serial No. FLD Remarks
Box Pin (FT ) EMI
19 OK PT OK 35.84 N/A REJECTED
21 MASH OK OK 38.36 N/A REJECTED
71 OK PT OK 38.38 N/A REJECTED
72 OK PS OK 38.56 N/A REJECTED

Note :
ABBREVIATIONS USED IN THIS SHEET:
SD – SEAL DAMAGE TD – THREAD DAMAGE Inspector :
CS - CORRODED SEAL PT - PITTED THREADS
BM - BODY MASHED DNP - DRIFT NOT PASSED SYAMKUMAR

PO Box:3288 Airport Heights, PC. 111, Muscat, Sultanate of Oman F-TUB-03 Rev-0