DESIGN OF ANNULAR PILE CAP FOR SARENGA PWSS

BLOCK: SARENGA; DISTRICT: BANKURA

Basic Data:
1. OHR Size 700 Cum
2. Radius of C.L. of column 4.25 m.
3. No. of column 10 nos.
4. Diameter of column 600 mm.
5. Size of pedestal 800 mm x 800 mm
6. Total vertical Load (DL + LL) 15050 KN
7. Base Shear 965 KN
8. Seismic Moment 24080 KN-m.

Here, we use 550 mm dia pile 36 nos.


Pattern of pile placement:
Sl. Angle Between
Placement of pile Radius Nos. of pile
No. Two Piles
1. Outer Ring Ring - 1 R1 = 5.90 m. 16 nos. 22.5 Degrees
2. Middle Ring Ring - 2 R2 = 4.25 m. 12 nos. 30 Degrees
3. Inter Ring Ring - 3 R3 = 2.60 m. 08 nos. 45 Degrees
TOTAL = 36 NOS.

Moment of Inertia (M.I.) of pile group, I = ∑ r2 Cos2Ɵ


I outer = 5.902 x [(2 x Cos20Ɵ) + (4 x Cos222.5Ɵ) + (4 x Cos245Ɵ) + (4 x Cos267.5Ɵ) + ((4 x Cos290]
= 34.81 x [ 2 + 3.4142 +2 + 0.5858 + 0] = 278.48 m2
I Middle = 4.252 x [(2 x Cos20Ɵ) + (4 x Cos230Ɵ) + (4 x Cos260Ɵ) + (4 x Cos290Ɵ) ]
= 18.06 x [2 + 3 + 1 + 0] = 108.375 m2
I Inner = 2.602 x [(2 x Cos20Ɵ) + (4 x Cos245Ɵ) + (4 x Cos290Ɵ) ]
= 6.76 x [ 2 + 2 + 0] = 27.04 m2
ITotal = I Outer + I Middle + I Inner
= 278.48 + 108.375 + 27.04
= 413.895 m2
Maximum Load on pile in Ring-1 (R1 = 5.90 m)
P1 = (15050 / 36) ± (24080 x 5.90 / 413.895 )
= 418.06 ± 343.26
= 761.32, 74.80 (No tension develop in pile)

You might also like