You are on page 1of 2

Report No.

: 1

Installation of trunkline,Flowline 1/2


Page :
and Manifold for A - Field at
Hamada NC-4
AGOCO-Job Nº: FIAL Order No.: Date : 13/08/2020
MTC-34/2009 520 10 30616
ULTRASONIC WALL THICKNESS MEASUREMENT REPORT
Site Location: 10" TIE-IN PIPELINE Wall Thickness: 11.633

Pipe Line No.:EXISTING 18" AGOCO OIL PIPELINE Material: EXISTING


Pipe Diameter : 10" UT Procedure: 000-FIS2000940-QA-MS
Length Examined: 3, 6, 9 & 12 o'clock
UT Instrument : 570277
Probe: 0.250 IN 15.0 MHz
Calibration Block: 8 mm

WALL THICKNESS MEASUREMENT (mm)


LOCATION ID POINT 1 POINT 2 POINT 3 REMARKS

3 o'clock P1(mm) 11.518


6 o'clock P2 (mm) 11.988
9 o'clock P3 (mm) 11.286
12 o'clock P4 (mm) 11.742

Point 3 Point 2 Point 1


12 o'clock

9 o'clock 3 o'clock

6 o'clock 300mm 300mm

700mm

Flow Direction

FIAL QA/QC AGOCO


FIAL SITE MANAGER
Inspector Inspector

Name: JOAN RENIS MAJID SHALADI


Signature:

Date: 13/08/20 13/08/20


Report No. : 1

Installation of trunkline,Flowline 2/2


Page :
and Manifold for A - Field at
Hamada NC-4
AGOCO-Job Nº: FIAL Order No.: Date : 13/08/2020
MTC-34/2009 520 10 30616
ULTRASONIC WALL THICKNESS MEASUREMENT REPORT
9 o'clock 12 o'clock
6 o'clock 3 o'clock Point 3 300mm Point
700mm
Flow2 Direction
300mm Point 1

3 o'clock P1(mm) 6 o'clock P2 (mm)

9 o'clock P3 (mm) 12 o'clock P4 (mm)

FIAL QA/QC AGOCO


FIAL SITE MANAGER
Inspector Inspector

Name: JOAN RENIS MAJID SHALADI


Signature:

Date: 13/08/20 13/08/20