Name of the Site: KZ1B_220/11KV MENTRAJPALLY

Customer: M/s AMRUTHA CONSTRUCTIONS

Sub Station: KZ6D_220/11 KV NTT MENTRAJPALLY SUBSTATION

Scope of Work: SAS PENDING ACTIVITIES

Project: KZ1B

For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 1 of 7
Visit Document
Visit Document

Contents

MINUTES OF MEETING 3

VISIT DETAILS 4

PENDING ACTIVITIES COMPLETION CERTIFICATE 4

COMMON POINTS 5

LIST OF OPEN POINTS 6

CUSTOMER FEEDBACK FORM ON GE T&D SERVICES 7

For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 2 of 7
Visit Document
Minutes of Meeting
Minutes of Meeting Held between M/s GE T&D INDIA LTD (Pallavaram) and M/s
AMRUTHA CONSTRUCTIONS & M/S TSTRANSCO MENTRAJPALLY SS on dated: 16-
05-2023 at KZ1B_220/11KV MENTRAJPALLY SUBSTATION.
Organization Represented by Signature
M/s GE T&D INDIA LTD
Mr. P.N.V.VARA PRASAD
(Pallavaram)
M/s AMRUTHA
Mr. N. RANGANATH GOUD
CONSTRUCTIONS
M/s TSTRANSCO Mr. PRUTHIVIRAJ

Customer Service Call Objective:


Service Request (Please tick √ )
Substation &
Commission Trouble Relay Application Refurbish
Circuit
-ing Shooting Testing / Settings —ment
220/11KV
MENTRAJPALLY 
SUBSTATION

Work Accomplished:
Substation Circuit/product Work done Remarks

Additional Work done:


Substation Circuit/product Work done Remarks

Attachments to this Document (Please tick)


 Comments by Customer
 Additional work Request
 Commissioning Completion Certificate

For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 3 of 7
Visit Document
Visit Details
Project : KZ1B

Site : 220/11KV MENTRAJPALLY S/S

Customer : M/s GE T&D INDIA LTD

Panel / Relay Type : Control Relay Panel/Numerical protection relay

Drawing Reference No. : KZ1B

M/s GE Representative has reached220/11KV MENTRAJPALLY SUBSTATION on 09/05/2023 and


Carried the following activities.

1. 220kV Bays, 220/11kV PTR Bays & Auxiliary Bay Unwanted Alarms Cleared As Per Customer
Requirement.
2. DOT MATRIX Printer Has Been Installed.
3. As Per TSTRANSCO Requirement 11kV pumps Modbus RS-485 Auxiliary Bay MW & MVAR
Values has been Configured, Values Are Found Ok.
4. Auxiliary BCU 11kV Pumps MW & MVAR Values Configured In Gateway, Values Are Found Ok.
5. As Per TSTRANSCO Requirement PTR-1 & PTR-2 LV Side MW & MVAR Values Has Been
Configured In Gateway.
6. As Per TSTRANSCO Requirement SAS Training Has Been Given To O&M Staff.
7. IMS Daily Reports & Hourly Reports Has Been Configured, Reports Found Ok.

For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 4 of 7
Visit Document

COMMON POINTS

DEVICE USER NAME PASSWORD


MAIN SERVER DCS_User Welcome!2
STANDBY SERVER DCS_User Welcome!2
DRPC DCS_Master Welcome!1
GATEWAY DCS_Master Welcome!1

1. Final database version


6_100_4_0_B1RC_KZ1B_TSTRANSCO_MENTRAJPALLY_EN.1.60.MPC has been loaded
all devices.
2. Final backup of Database Has Been Saved To DR PC Local Disk: D; 16-05-23 Final Backup
Folder.

List of Open Points

Project : KZ1B

Site : 220/11KV MENTRAJPALLY S/S

End Customer 33333333333333333333333


: M/s TSTRANSCO

Panel / Relay Type : CRP

Drawing Reference No. : KZ1B

Sl. No. Description of Open Points Remarks


For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 5 of 7
Visit Document
1. Inverter-1 &2 DC Incoming Supply M/s TSTRANSCO Ask TO Configure in SCADA, As per Scheme it’s
Not Available & Customer Didn’t Provide The Wiring.
2.

Customer Feedback Form on GE T&D Services


Customer : M/S AMRUTHA CONSTRUCTIONS
Organization : M/S TSTRANSCO
Site : 220/11 KV MENTRAJPALLY S/S
GE Engineer : P.N.V.VARA PRASAD

PRESENT Service: (Please tick () the appropriate box)


Yes No
Do you feel that the job was handled time consciously?

Are you happy with services of this Engineer ?

Any suggestions for the engineer to improve

Did the service engineer briefed up on the Catalogue of Services


(Viz.Retrofit,Training )

Did the Service engineer handover the catalogue for Retrofit / Training

GENERAL:
Excellent Average Poor

Response Time

Quality of Response

Quality of Site Service

Quality of Relay repair

Any Suggestion to Improve:

For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 6 of 7
Visit Document
Customer Name :
Designation :
Seal of the Customer :

For M/s. GE T&D India Ltd For M/s. AMRUTHA For M/s. TSTRANSCO
(Pallavaram) CONSTRUCTIONS

Mr. P.N.V.VARA PRASAD Mr. Mr.


SAS ENGINEER
DATE:

Page 7 of 7