Daikin Industries, Ltd.’s products are manufactured for export to numerous countries throughout the Catalogue CA-DXE-B-202001
world. Daikin Industries, Ltd. does not have control over which products are exported to and used in
a particular country. Prior to purchase, please therefore confirm with your local authorized importer,
distributor and/or retailer whether this product conforms to the applicable standards, and is suitable
for use, in the region where the product will be used. This statement does not purport to exclude,
restrict or modify the application of any local legislation.
● Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
DXE-B Series
● Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorized parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
● Read the User’s Manual carefully before using this product. The User’s Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
Purification-type Modular Air Handling Unit DXE
If you have any enquiries, please contact your local importer, distributor and/or retailer.
Dealer
Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
DXE-B
pressure mm/m
DXE-B
DDM-E cabinet complies with EN1886 standard class. High level Low level
It is famous for its strict testing process and high standard requirements. It is highly recognized all over
Casing strength D1 the
Casing air D2
leakage class D3
L1
Casing air leakage class
Casing strength D1 Maximum leakage rate of the cabi
4 10 >10
pressure mm/m
Filer bypass leakage
Filter bypass leakage F9
Purification-type Modular Air Handling Unit handling unit. Mechanical characteristics and
Casing whole
air leakage machine
class performance
L1
Casing of theclass
air leakage product are tested respectively.
Maximum leakage rate of the cabinet under -400Pa test pressure l/(s.m )
L1
0.15 2
L2
0.44
L3
1.32
Thermal transmittance of the
Filer bypass leakage F9 F8Thermal transmittance
F7 F6 G1~F5
T2
Filter bypass leakage F9 of the2casing
e 0.5 1 4 6 Cabinet transmittance factor
DDM-E cabinet complies with EN1886 standard class. Thermal transmittance of the casing
High level T1 T2 T3 T4
Low levelT5
Thermal transmittance Thermal bridging factor
T2 Thermal bridging factor TB1
of the casing Cabinet transmittance factor (U)W/(m2.K) U≤0.5 0.5<U≤1.0 1.0<U≤1.4 1.4<U≤2.0 No requirement Thermal bridging factor of the
Casing strength D1
AHRI certified
Casing strength
Thermal bridging factor
TB1
Thermal bridging factor
Thermal bridging factor of the cabinet Kb
D1
TB1 TB2 TB3
D2
TB4 TB5
0.75<Kb<1.00 0.60<Kb≤0.75 0.45<Kb≤0.60 0.30<Kb≤0.45 No requirement
D3
4 10 >10
pressure mm/m
Casing air leakage class L1 L2 L3
Casing air leakage class L1
Maximum leakage rate of the cabinet under -400Pa test pressure l/(s.m2) 0.15 0.44 1.32
AHRI certification is a product quality certification system
Filer bypass leakage F9 F8 F7 F6 G1~F5
Filter bypass leakage F9 for HVAC industry in North America. It is one ofethe most 0.5 1 2 4 6
influential certification
Thermal transmittance institutions
of the casing in the world. Adhering T1 T2 T3 T4 T5
Thermal transmittance DXE-B5 cabinet
DDM-E5 cabinet conforms
conforms to theto the grade.
grade.
T2
of the casing tocabinet
DDM-E5
Cabinet transmittance factorand
the tenet
conformsof integrity
to the grade. customer service, AHRI
(U)W/(m2.K) U≤0.5 0.5<U≤1.0
High level
1.0<U≤1.4 1.4<U≤2.0
Low level
No requirement
CD CD2 CD3 CD4 CD8
certification hasfactor
Thermal bridging become
CD
a famous brand in North America
O TB110
1
TB2
8 6 TB3 4 TB4 1
CD1 TB5
Thermal bridging factor TB1
1 2
and even
Thermal in thefactor
bridging world. AHRI
of the certification
cabinet Kb mainly includes
0.75<Kb<1.00
0.0033(1/300) 0.60<Kb≤0.75
0.0042(1/240) 0.45<Kb≤0.60
0.0042(1/240) 0.30<Kb≤0.45
0.0042(1/240) No requirement
≥0.0042(1/240)
Casing air leakage class CL1 CL2 CL3 CL0 CL12 CL24 CL100 Casing air leakage class
standard
Casing AHRI
air leakage class 1350
CL focusing Maximum
1 on evaluating cabinet
casing air leakage rate 1(0.0508L/ 2(0.1016L/ 3(0.1524L/ Casing air12(0.6096L/
6(0.3048L/ leakage class CL1
24(1.2192L/ 100(5.08L/ Maximum casing air leakage
CLncfm/100ft (Pr=1 in.H2O)
2
(m2s)) (m2s)) (m2s)) (m2s)) (m2s)) (m2s)) (m2s)) CLncfm/100ft2(Pr=1 in.H2O)
strength, air leakage rate, thermal insulation and cold
Thermal transmittance class CT1 CT2 CT3 CT4 CT5 Thermal transmittance class
Thermal transmittance
bridge
class of the air handling
CT unit.Thermal transmittance without leakage (U).Btu/ft /”F
1
2
U 0.14 0.14<U 0.23 Thermal
0.23<U 0.36transmittance
0.36<U 0.55 U>0.55
CT1 Thermal transmittance without le
Thermal transmittance with leakage (U).Btu/ft2/”F U 0.16 0.16<U 0.26 0.26<U 0.39class0.39<U 0.61 U>0.61
Thermal transmittance with lea
Casing thermal Casing thermal bridging class CB0 CB1 CB2 CB3 CB4 CB5
CB1 Casing Casing thermal bridging class
bridging class Thermal bridging factor (Kb) Kb 0.8 Kb 0.8 0.8>Kb 0.6 0.6>Kb thermal
0.4 0.4>Kb 0.2 Kb<0.2
CB1
bridging class Thermal bridging factor (Kb)
performance capabilities. Thermal transmittance class CT1 CT2 CT3 CT4 CT5
Thermal transmittance CT1 Thermal transmittance without leakage (U).Btu/ft2/”F U 0.14 0.14<U 0.23 0.23<U 0.36 0.36<U 0.55 U>0.55
class
Thermal transmittance with leakage (U).Btu/ft2/”F U 0.16 0.16<U 0.26 0.26<U 0.39 0.39<U 0.61 U>0.61
Casing thermal Casing thermal bridging class CB0 CB1 CB2 CB3 CB4 CB5
CB1
bridging class Thermal bridging factor (Kb) Kb 0.8 Kb 0.8 0.8>Kb 0.6 0.6>Kb 0.4 0.4>Kb 0.2 Kb<0.2
EUROVENT certified
2 3
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
Innovative Structure
● Cable gland for sealing at unit connection port; sealant and heat-in-
sulating sealing strip for sealing at water inlet/outlet pipe in the coil
section
Combining the requirements of industrial cleaning and commercial cleaning applications, the
Constant flow one-piece seal ring
DXE-B series units can provide customers with two customized structural types: standard
and clean models. The unit cabinet adopts an innovative double-layer closed frame structure:
the high-strength aluminum alloy/steel structure frame is completely wrapped in the thermal
3 4
insulation frame to prevent cold bridges of the frame, and has higher strength; it also adopts
fluorine-free and environmentally friendly high-density foam panels, and the inner and outer
Multiple anti cold bridge measures Applicable to various environments
panels are connected by ultra-long thermal insulation polymer materials, which can prevent
cold bridge and has strong insulation, while the panels are connected by anti-cold bridge bolts.
In addition, the cabinet is sealed with an advanced constant-flow one-piece seal ring or closed-
cell high-elastic seal strip, with excellent sealing performance.
4 5
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
Advanced Clean
Cabinet Technology
Clean design
1. Flat and smooth cabinets both inside 2. Excellent bacteriostatic and antiseptic
and outside effects
Compliance with clean design requirements specified in VDI6022 and Eurovent Hygienic option
Major
requirements
● Large-size integrated access door for easy access
● Optional connecting rod structure for more convenient use
Spray inner panel or SUS; smooth inner surface; double-layer panel; antibacterial material;
Cabinet design
pore-free sealing material ● Externally fixed panels support easy disassembly
Drainage pan for fresh air filtering for easy cleaning; with differential pressure device; filter
Filter section
materials to prevent the growth of microorganism
● Optional inspection lamp and wide-angle aerial check window for better
visibility without condensation
Aluminum fin with big spacing, and copper heat exchange tube and gas collecting pipe; oblique
Heat exchanger
SUS drain pan; condensed water discharge device Convenient One-click Broader
Easy removal
maintenance open vision
Fan section Direct driven fan to prevent belt driving; easy to clean
6 7
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
Multiple Layers of
Clean Heat Exchange
Antibacterial Filtration
1. Multiple options for dust 2. Optimized design for long- 3. A i r t i g h t i n s t a l l a t i o n w i t h 1. Optimized design for effective 2. Quality materials contributes to
removal and anti-bacteria term high efficiency minimum leakage anti-corrosion durable service
Mold spores
Bacillus
Worm
Influenza virus
Dust
● Big spacing design of heat exchanger makes it easy to clean ● New water-based pain for header of the heat exchanger,
● Various dust removal and sterilization ● Optimized V-shaped bag structure to ● High-density and high-elastic sealing
devices available: primary-efficiency/me- ● Standard three-dimensional quick drainage pan with small corrosion resistant
achieve lower filter resistance; high dust parts/constant flow one-piece seal ring for
dium-efficiency/high-efficiency/electronic drainage resistance to achieve smoother drainage ● Quality aluminum alloy/stainless steel waterproof board
holding and low resistance design for lon- frame sealing
purification/ultraviolet sterilization/ozone ger service life ● Heat exchanger placed overhead the drainage pan to prevent with excellent corrosion resistance and aging resistance
generator/nano photon purification, etc. ● New buckle design with better clamping the coil from breeding bacteria performance
● Waterproof ultra-fine glass fiber melt- effect
● Optional primary-/medium-/high-efficiency ● Streamlined eliminator with low resistance and good gas-water ● Optional hydrophobic fin for smooth drainage and corrosion
blown antibacterial filter material, antibac-
filters: G3-G4/M5-F9/H10-H13; separation effect resistance
terial agent can be added to avoid bac-
● "Ultra-clean" technology with high-pres- terial growth and guarantee more stable ● Drainage pan with small waterproof strip to prevent the ● Optional corrosion-resistant stainless steel for the installation
sure ionization for electrostatic dust re- efficiency throughout the service life condensed water from splashing outside of the drain pan metal plate in the coil section
moval and effective sterilization
8 9
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
High-efficiency and
Stable Dust-free Air Supply
Quality Assurance with
Clean design Diversified Functions
The diversified function matching design of the "DXE-B" series units
can provide customized solutions for various industries through a
professional technical team,
1. Innovative clean design 2. Quality parts are corrosion-resistant and and provide customers with better
dustproof quality and service.
● Optional EC fan or plug fan for the fan section to prevent ● Quality bearings with longer service life
dust due to belt wear
● Smooth air inlet/outlet canvas without dust
● IP55-rated standard waterproof motor
accumulation, can be removed for cleaning Air inlet section Sealed damper Inlet/Outlet air flange soft connection
● Concealed fan bracket design and flat and smooth inner
surface to guarantee complete cleaning The air inlet section provides enough space to fully blend the fresh air and return air so as to avoid air stratification and
prevent condensation inside the cabinet.
● Optional built-in damper to efficiently prevent air leak and condensation
Damper material: quality aluminum alloy/stainless steel/hot-dip galvanized coating; sealed damper (optional)
Worry-free convenient maintenance damper type: manual/electric
● Optional devices for the air inlet section: access lamp/view port/canvas soft connection/3D drainage pan
● A linked switch can be set between the fan and the access door, and the fan
will automatically stop when the access door in the fan section is opened
● Standard fan air inlet protective mesh enclosure to protect personal safety
● Standard integrated access door to provide big space for inspection and
Muffler Section
maintenance
● Optional motor maintenance hanging bracket for more convenient motor
maintenance and replacement
● Porous metal plate with high-quality sound-absorbing cotton
● Compression ring can be equipped in the fan section to timely monitor the inside, which can meet the fire safety requirements
air flow and air pressure of the unit and maintain the indoor and outdoor
● Better noise reduction effect if it is placed in the positive pres-
pressure difference
sure section of the unit
Accurate Motor ● High- and medium-efficiency or above filters installed after the
Protective mesh
Linked switch pressure maintenance
enclosure muffler section of high-grade clean places for enhanced safety
tapping hanging bracket
and reliability
● Optional side-drawing design for easier replacement and
cleaning.
Muffler section Perforated metal frame
10 11
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
● The coils of the whole series of units have been certified by the
R Air-Conditioning, Heating, and Refrigeration Institute (AHRI) to ensure
www.ahridirectory.org
the excellent heat exchange performance of the units
● All coils are subjected to pressure test before delivery to ensure no
leakage
● Coil equipped with a new corrugated hydrophilic aluminum foil,
cross-counterflow design, optimized heat transfer effect
● Coil header sealed with a heat-insulating seal ring to prevent cold
bridges and reduce air leakage from the unit
● Optional side-drawing design for easier cleaning
Optional aluminum foil material: anti-corrosion aluminum foil/copper
foil
Secondary flanging design
Optional coil header material: seamless steel header/copper header
● Proportional adjustment control, stable, reliable, and ● Clean steam humidification to prevent bacteria breeding
of fins does not damage the more precise
copper tube Other options: stainless steel frame ● Quality all-stainless steel seamless pipes to prevent rust;
● Support of multiple control signals such as DC 0-10 V or nozzles arranged evenly along the length of the nozzle
DC 0-5 V, and 4-20 mA pipe to make the steam evenly distributed throughout the
● Use of electric heating humidification to avoid frequent length of the pipe
water drainage of the humidifier with less energy used ● Heat-resistant non-metallic nozzles spray no condensed
● Stainless-steel fast-absorption steam spray rod to realize water, which can ensure 100% dry steam humidification
2 3
highly efficient anti-corrosion ● Sufficient humidification distance to make sure that
Electric heater Steam coil ● Low water level protection device to effectively monitor steam can be completely absorbed
the use of the humidifier ● Sealed installation of steam inlet to effectively prevent
cold bridge and air leakage
10
12 13
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
Discharge
air
14 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
13 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
One-to-one energy recovery system One-to-more energy recovery system Heat tube heat recovery principle Heat tube heat recovery device 12 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
11 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
● No cross-contamination, less dependent on space, easy to install, The heat tube is a high-efficiency and energy-saving component. It is
applicable to places with long air supply and discharge distance made of pure aluminum tube rolled into aluminum fin tube, cleaned 10 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
and pumped into high vacuum, and is charged with a certain amount
● Energy saving: It recovers the heat on the discharge side through of heat transfer working medium, which is usually R134a. When the
9 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
the circulation of the ethylene glycol medium inside the heat ex- air-conditioning system supplies heat, the working medium in the
changer, so as to realize the pre-cooling or pre-heating effect on 8 5 6 7 8 9 10 11 12 13 14 15 16 17 18
vacuum tube condenses on the fresh air side and evaporates on the
the fresh air side, and reduce energy consumption return air side, and circulates repeatedly to recover heat; it is quite the 7 5 6 7 8 9 10 11 12 13 14 15 16
● One-to-one or one-to-more energy recovery system as required contrary for cooling.
6 5 6 7 8 9 10 11 12 13 14
● Optional heat tube: Normal temperature sensible heat recovery
and low temperature sensible heat recovery 5 5 6 7 8 9 10 11 12
● Characteristics of heat tube: Large heat exchange capacity, 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
rapid thermal response, low resistance loss, no energy loss or
cross-contamination
14 15
DXE-B
Purification-type Modular Air Handling Unit
DXE-B
380V/3N~/50Hz
Unit air flow (m3/h) Cabinet size (panel thickness: 50 mm) Q1 Connecting places for remote
I> I> I> Symbol Description
building control
Model L 1 Q1 Circuit breaker
interlocking signal
Fire protection
signal
Local/remote feedback
units
Fault feedback signal for
DO3 H1
SF1
DXE0609 4388 4876 5364 5851 840 1221 OL1 K2 K1 KM1 TB1-2
TB1-2 Terminal block
AO5 K3
U V W 3 8
DXE0709 5295 5883 6471 7060 967 T3 H3 1221
23 25 27
21
F2 M HL3 HL2 HL1 Factory Wiring
K1 KM1 K2
DXE0714 9542 10602 11662 12722 967 1856 ~ 1 2 Field Wiring
M
HMI
DXE1313 17517 19463 21409 23356 1729 1729
DXE1315 1 2 18326
3 4 5 6 7 1 2 3 20362
4 5 6 7 8 9 10 11 22398
12 13 14 1 2 3 4 5 24434
1 2 3 4 5 6 7 8 1729 1983 N
Q1
N
Connecting places for
I> I> I>
DXE1316 21563 23959 26355 28751 1729 2110 remote building control
Symbol Description
2 Q1
Q1 Circuit breaker
L F1/4A 1 1 2 KM1 9
interlocking signal
Fire protection
remote control
Signal of starting/stopping
manual feedback
Signal of automatic/
for units
Fault feedback signal
OL1 SF1
SF1 Stop button
V1 W1 TB2 K3 K2 K1 KM1
DXE1722 40851 45390 49929 54468 2237 2872 U1
3
7 11 13
TB1-3
TB1-3 Terminal block
W2 V2 U2
U2
M 21 23 25 27
V2
DXE1821 41331 45923 50515 55108 2364 2745 ~ W2 HL1
Factory Wiring
K1 HL3 KM1 K2 HL2 KT1 KM3 KM2
1 2 Field Wiring
DXE1826 52109 57899 63689 69479 2364 3380 Fan Motor
KM3
16
14
16 17
DXE-B
Purification-type Modular Air Handling Unit
Connecting
楼宇远程控制接点 places for
380V/3N~/50Hz
remote building control
R S T N PE
远 自
signal
Fire protection interlocking
remote control
Signal of starting/stopping
feedback
Signal of automatic/manual
units
Operation feedback signal for
机组故障反馈信号
机组运行反馈信号
消 程 动
防 控 /
联 制 手
ON 动
锁
/ 反
信 OFF 馈
Q1 号 信 信
I> I> I>
N
号 号
1 2 20 21 22 23 24 25 26 27
L
TB2
Feedback signal Control signal
F1
Building
automation system
楼控系统 反馈信号 控制信号 21 22 24 26
9 - -
+
K3 K2 K1
1
KM1 0-20mA 0-10Vdc
23 25 27
K4
10 20
2 1 2
KM1 10 11 12 13 7 9 2 3
PE U1 V1 W1 +24V GND DCOM DI1 AO1 AGND AI1 AGND
Symbol Description
OL1
VFD Q1 符号 Circuit breaker 描述
F1 Q1 Fuse 断路器
U2 V2 W2 RO2C RO2B RO3C RO3A K1-4 F1 熔断器
Intermediate relay (220 VAC coil)
22 24 25 26
SW1 K1-4 中间继电器(220Vac线圈)
On/Off/Remote three-position switch
M U V W OL1
TB1-2VFD 变频器
Terminal block
~ 7 TB1-2
Cooling
冷却电机 fan M 8
端子排
~ M
~
工厂接线
Factory Wiring
18 21