You are on page 1of 112

SYSTEM AIR CONDITIONER

INDOOR UNIT OUTDOOR UNIT


Model : NS100SSXEA RC100SHXEA
NS090SDXEA RC090SHXEA
NS090SSXEA RC090DHXEA
NS090SSXEX RC100DHXEA
NS100SSXEX RC100DHXGA
NS100SDXEA RC125DHXEB
NS125SDXEA RC125DHXGA
NS140SDXEA RC140DHXEB
RC140DHXGA

AIR CONDITIONER CONTENTS

1. Precautions

2. Product Specifications
NS090SDXEA, NS100SSXEA
NS090SSXEA, NS090SSXEX, NS100SSXEX 3. Disassembly and Reassembly

4. Troubleshooting
NS100SDXEA
NS125SDXEA 5. Exploded Views and Parts List
NS140SDXEA

6. PCB Diagram

7. Wiring Diagram

8. Schematic Diagram
RC090DHXEA RC125DHXEB
RC090SHXEA RC125DHXGA
RC100SHXEA RC140DHXEB 9. Reference Sheet
RC100DHXEA RC140DHXGA
RC100DHXGA

Refer to the service manual in the GSPN(see the rear cover) for the more information.

Downloaded from www.Manualslib.com manuals


NS100SSXEA_E_33623A(1)_co.indd 1 search engine 2011-04-08 �� 10:52:44

Contents
11. Precautions ......................................................................................................................................... 1-1
1-1 Precautions for the Service............................................................................................................... 1-1
1-2 Precautions related to static electricity and PL............................................................................. 1-1
1-3 Precautions related to product safety............................................................................................ 1-2
1-4 Other precautions. ............................................................................................................................. 1-2

12. Product Specifications ................................................................................................................ 2-1
2-1 The Feature of Product...................................................................................................................... 2-1
2-2 Product Specifications....................................................................................................................... 2-2
2-3 Specifications of optional items. ..................................................................................................... 2-6
2-3-1 Accessories................................................................................................................................ 2-6

13. Disassembly and Reassembly . .............................................................................................. 3-1


3-1 Indoor Unit . ........................................................................................................................................ 3-2
3-2 Outdoor Unit ...................................................................................................................................... 3-7

14. Troubleshooting ............................................................................................................................. 4-1


4-1 Indoor Display Error and Check Method ...................................................................................... 4-1
4-1-1 Wired Remocon Error Display(COM2) ................................................................................. 4-2
4-2 Outdoor LED Error Display and Check Method ........................................................................... 4-3
4-3 Setting Option Setup Method . ....................................................................................................... 4-4
4-3-1 Type A(Setting Option) .......................................................................................................... 4-4
4-3-2 Type B(Setting Option Setup Method) . .............................................................................. 4-6
4-3-3 Option code for each model ................................................................................................. 4-16
4-4 Items to be checked first .................................................................................................................. 4-17
4-5 Fault Diagnosis by Symptom .......................................................................................................... 4-18
4-5-1 No Power(completely dead) - Initial diagnosis . ................................................................ 4-18
4-5-2 The Outdoor unit Power Supply error . ............................................................................... 4-19
4-5-3 The Outdoor unit Fan error ................................................................................................... 4-20
4-5-4 Total current trip error . .......................................................................................................... 4-21
4-5-5 In case of heating at the cooling mode or cooling at the heating mode ..................... 4-22
4-5-6 Outdoor temperature sensor error ...................................................................................... 4-24
4-5-7 Discharge temperature sensor error ................................................................................... 4-25
4-5-8 Coil temperature sensor error . ............................................................................................. 4-26
4-5-9 Fan error . .................................................................................................................................. 4-27
4-5-10 DC-Link voltage sensor error .............................................................................................. 4-28
4-5-11 O.C.(Over Current) error . ..................................................................................................... 4-29

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 1 search engine 2011-04-08 �� 10:54:25

Contents
4-5-12 Communication error . ......................................................................................................... 4-30
4-5-13 Compressor start error ......................................................................................................... 4-31
4-5-14 Compressor lock error . ........................................................................................................ 4-32
4-5-15 DC Link Over voltage/ Low voltage error ......................................................................... 4-33
4-6 PCB Inspection Method .................................................................................................................... 4-34
4-6-1 Pre-inspection Notices............................................................................................................ 4-34
4-6-2 Inspection Procedure ............................................................................................................. 4-34
4-6-3 Indoor Detailed Inspection Procedure . .............................................................................. 4-34
4-6-4 Outdoor Detailed Inspection Procedure ............................................................................ 4-35
4-7 Main Part Inspection Method . ........................................................................................................ 4-36

15. Exploded Views and Parts List .............................................................................................. 5-1


5-1 Indoor Unit . ........................................................................................................................................ 5-1
5-2 Outdoor Unit ...................................................................................................................................... 5-7
5-3 Ass'y Control Out ............................................................................................................................... 5-11

16. PCB Diagram ...................................................................................................................................... 6-1


6-1 PCB Diagram . ..................................................................................................................................... 6-1
6-1-1 Indoor Unit ............................................................................................................................... 6-1
6-1-2 Outdoor Unit PCB . .................................................................................................................. 6-3

17. Wiring Diagram ............................................................................................................................... 7-1
6-1 Indoor Unit . ........................................................................................................................................ 7-1
6-1 Outdoor Unit ...................................................................................................................................... 7-2

18. Schematic Diagram ....................................................................................................................... 8-1


8-1 Indoor Unit . ........................................................................................................................................ 8-1
8-1-1 MAIN PCB . ................................................................................................................................ 8-1
8-1-2 Outdoor Unit PCB . .................................................................................................................. 8-2
1
9. Reference Sheet ............................................................................................................................... 9-1
9-1 Index for Model Name....................................................................................................................... 9-1
9-2 Refrigerating Cycle Diagram............................................................................................................ 9-3
9-3 Pressure Graph.................................................................................................................................... 9-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 2 search engine 2011-04-08 �� 10:54:25
1. Precautions

1-1 Precautions for the Service


 Use the standard parts when replacing the electric parts.
– Confirm the model name, rated voltage, rated current of the electric parts.

 When repairing the equipment, connection of the harness parts must be firm and solid.
– A loose connection may cause noise or other malfunction.

 When assembling and disassembling the equipment while it is laid down, lay it on soft cloth.
– Otherwise it may scratch the back of the exterior of the product.

 Remove dust or dirt completely from the housing block, wiring block and service parts during repair.
– This helps prevent the danger of fire caused by tracking or short circuit.

 Fasten the valve caps of service valves and charging valves of outdoor unit as much as possible using adjustable wrenches.

 Check the status of the components’ assembly after repair service.


– The status must be the same as before the repair service.

1-2 Precautions related to static electricity and PL


 The PCB power supply block is susceptible to static electricity. Therefore, care must be taken during repair or measuring
while the power is on.
– Wear insulation gloves for PCB repair or measuring.

 Check whether the installation location is at least two meters away from other electronic products such as TV, video, or
audio.
– Otherwise, the video quality might be degraded or noise might be generated.

 Do not let end users repair the products themselves.


– Unauthorized disassembly might cause electric shock or fire.

Samsung Electronics 1-1

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 1 search engine 2011-04-08 �� 10:54:26
1-3 Precautions related to product safety
 Do not pull the power cord and do not touch the power plug or aux power switch with wet hands.
– It might cause electric shock or fire.

 A damaged power line or power plug must be replaced to prevent danger.

 Do not bend the power cable with excessive force, and do not place a heavy weight on the case as it might damage the
cable.
– It might cause electric shock or fire.

 Do not use multiple electric outlets.


– This might cause electric shock or fire.

 Connect the ground terminal when necessary.


– You must connect the ground terminal if you determine that there is a danger of electric leakage due to moisture or water.

 Unplug the power cable or turn off the auxiliary power switch for electric part replacement and repair service.
– Otherwise it might cause electric shock.

 Instruct end users to separate the batteries from the remote controllers and store them separately when the product is not
used for long time.
– Otherwise leakage from the dry cell may cause problems with the remote controller.

1-4 Other precautions


 The pipes should have no leaks during installation, and the compressor must be stopped before removing connecting
pipes for pump down work. Operating the compressor while the service valve is open and coolant pipe is not properly
connected may cause explosion or injury due to abnormal high pressure created inside the coolant cycle as the air can be
absorbed through the pipe.

 Pump Down work procedure (When uninstalling the product)


– Turn on the air conditioner, select cooling operation, and run the compressor for more than three minutes.
– Release the high pressure and low pressure valve caps.
– Close the high pressure valve completely using an L-wrench
– After about two minutes, close the low pressure valve completely.
– Stop running the air conditioner.
– Separate the connecting pipe.

1-2 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 2 search engine 2011-04-08 �� 10:54:26
2. Product Specifications

2-1 The Feature of Product

 Built-in Cassette Type


After installed, the air conditioner can be harmonized with a room interior.

 High Performance & Energy Saving


With the advanced BLDC inverter technology, it makes a room cool with highly energy saving and arises the efficiency of
air conditioner.

 Long Piping(Length & Height)


It can give the benefit to the installers and aries the reliability of the air conditioner.

 Long Ambient Operation(In Low Temperature)


It can arise the reliability and the capacity of the air conditioner, especially operated in low temperature.

 Eco-friendly Product(Lead-Free, RoHS, WEEE)

Samsung Electronics 2-1

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 1 search engine 2011-04-08 �� 10:54:26
2-2 Product Specifications

NS090SSXEA NS100SSXEA
NS090SDXEA
ITEM NS090SSXEX NS100SSXEX
/RC090DHXEA
/RC090SHXEA /RC100SHXEA

Indoor Unit

Outdoor Unit
IMAGE

Remote Controller

Power Product 1Φ, 220~240V/50Hz 1Φ, 220~240V/50Hz 1Φ, 220~240V/50Hz


Indoor LxHxD mm 1150x480x320 1150x480x260 1150x480x260
Outdoor LxHxD mm 940x330x998 940x330x998 940x330x998
Indoor Product kg(Net) 39.0 34.0 34.0
Outdoor Product kg(Net) 72.0 72.0 72.0
Cooling(STD) W 9000 9000 10000
Capacity
Heating(STD) W 10000 9500 11200

Power Cooling(STD) W 2800 3200 3560


Consumption Heating(STD) W 2770 2780 3720

Operation Cooling(STD) A 13.0 14.0 16.0


current Heating(STD) A 12.5 13.0 15.0
In case of strongest air
Noise Indoor unit A 48/49 49/50 49/50
blow
(Cooling/
In case of strongest air
Heating) Outdoor unit A 58/60 59/62 59/62
blow
Refrigerant g 3000 2500 2500
Liquid mm 9.52 9.52 9.52
Connecting Pipe
Gas mm 15.88 15.88 15.88
Additional Refrigernat g/m 50 50 50
Standard m 5 5 5
Extension length(Total) m 50 50 50
Extension length(Elevation) m 30 30 30
011044-156299- 011044-156293- 011044-156293-
Product Option
275A64-350000 275A64-370000 276470-370000
Option Code
020000-100000- 020000-100000- 020000-100000-
Installation Option
200000-300000 200000-300000 200000-300000

2-2 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 2 search engine 2011-04-08 �� 10:54:26
Product Specifications (cont.)

ITEM NS100SDXEA/RC100DHXEA NS100SDXEA/RC100DHXGA

Indoor Unit

Outdoor Unit
IMAGE

Remote Controller

Power Product 1Φ, 220~240V/50Hz 3Φ, 380~415V/50Hz


Indoor LxHxD mm 1200x650x360 1200x650x360
Outdoor LxHxD mm 940x330x998 940x330x998
Indoor Product kg(Net) 55.0 55.0
Outdoor Product kg(Net) 72.0 81.0
Cooling(STD) Btu or W 10000 10000
Capacity
Heating(STD) Btu or W 11200 11200

Power Cooling(STD) W 3120 3120


Consumption Heating(STD) W 3100 3100

Operation Cooling(STD) A 13.8 5.0


current Heating(STD) A 13.5 5.0
In case of strongest air
Noise Indoor unit dB 49/50 49/50
blow
(Cooling/
In case of strongest air
Heating) Outdoor unit dB 59/63 59/63
blow
Refrigerant g 3000 3100
Liquid mm 9.52 9.52
Connecting Pipe
Gas mm 15.88 15.88
Additional Refrigernat g/m 50 50
Standard m 5 5
Extension length(Total) m 50 50
Extension length(Elevation) m 30 30
Product Option 011044-1560E8-276470-370000 011044-1560E8-276470-370000
Option Code
Installation Option 020000-100000-200000-300000 020000-100000-200000-300000

Samsung Electronics 2-3

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 3 search engine 2011-04-08 �� 10:54:27
Product Specifications (cont.)

ITEM NS125SDXEA/RC125DHXEB NS125SDXEA/RC125DHXGA

Indoor Unit

Outdoor Unit
IMAGE

Remote Controller

Power Product 1Φ, 220~240V/50Hz 3Φ, 380~415V/50Hz


Indoor unit Product LxHxD mm 1200x650x360 1200x650x360
Outdoor unit Product LxHxD mm 940x330x1210 940x330x1210
Indoor unit Product kg(Net) 55.0 55.0
Outdoor unit Product kg(Net) 88.0 91.0
Cooling(STD) Btu or W 12500 12500
Capacity
Heating(STD) Btu or W 14000 14000
Cooling(STD) W 3890 3890
Power consumption
Heating(STD) W 3880 3880
Cooling(STD) A 17.8 6.0
Operation current
Heating(STD) A 17.8 6.0
Indoor In case of strongest
dB 50/51 50/51
Noise unit air blow
(Cooling/Heating) Outdoor In case of strongest
dB 59/61 59/61
unit air blow
Refrigerant g 2900 2900
Liquid mm 9.52 9.52
Connecting Pipe
Gas mm 15.88 15.88
Additional Refrigerant(g/m) g/m 50 50
Standard m 5 5
Extension length(Total) m 75 75
Extension length(Elevation) m 30 30
Product
011044-1570F8-277D8C-370000 011044-1570F8-277D8C-370000
Option
Option Code
Installation
020000-100000-200000-300000 020000-100000-200000-300000
Option

2-4 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 4 search engine 2011-04-08 �� 10:54:29
Product Specifications (cont.)

ITEM NS140SDXEA/RC140DHXEB NS140SDXEA/RC140DHXGA

Indoor Unit

Outdoor Unit
IMAGE

Remote Controller

Power Product 1Φ, 220~240V/50Hz 3Φ, 380~415V/50Hz


Indoor unit Product LxHxD mm 1200x650x360 1200x650x360
Outdoor unit Product LxHxD mm 940x330x1210 940x330x1210
Indoor unit Product kg(Net) 55.0 55.0
Outdoor unit Product kg(Net) 88.0 91.0
Cooling(STD) Btu or W 14000 14000
Capacity
Heating(STD) Btu or W 16000 16000
Cooling(STD) W 4650 4650
Power consumption
Heating(STD) W 4430 4430
Cooling(STD) A 21.3 7.2
Operation current
Heating(STD) A 20.3 6.9
Indoor In case of strongest
dB 50/51 50/51
Noise unit air blow
(Cooling/Heating) Outdoor In case of strongest
dB 60/62 60/62
unit air blow
Refrigerant g 3400 3400
Liquid mm 9.52 9.52
Connecting Pipe
Gas mm 15.88 15.88
Additional Refrigerant(g/m) g/m 50 50
Standard m 5 5
Extension length(Total) m 75 75
Extension length(Elevation) m 30 30
Product
011044-167208-278CA0-370000 011044-167208-278CA0-370000
Option
Option Code
Installation
020000-100000-200000-300000 020000-100000-200000-300000
Option

Samsung Electronics 2-5

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 5 search engine 2011-04-08 �� 10:54:31
2-3 Specifications of optional items

2-3-1 Accessories

Item Description Code No. Q’ty Remark

User’s manual DB98-28944A 1

Installation manual DB98-28943A 5

DB62-03439J 1
Insulation
DB62-03439H 1

Essential Offer
Insulation Drain In DB62-03440H 1

DB72-00143E 1
Insulation Install Inlet
DB72-00143G 1

Ass'y Holder Drain Pipe DB90-02064A 1

Ass'y Drain Hose Joint DB94-00758A 1

2-6 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 6 search engine 2011-04-08 �� 10:54:32
Product Specifications

Accessories (cont.)

■ Receiver & display unit & Wire kit

Item Descriptions Code-No. Q'TY Remark

DB93-00449A
Receiver & display unit 1
(MRK-B00)

STS 2S-2x10 Tapped Screw - 4

2S-4x12 Tapped Screw - 2

Concealed type
User’s manual DB98-05160A 1

Installation manual DB98-05186A 1

DB39-00223A
Wire kit 1
(MRW-10A)

DB93-01066A
Receiver & display unit 1
(MRK-A00)

M4x12 Tapped Screw - 7

Cable-tie - 2

Standard type

User’s manual DB98-04184A 1

Installation manual DB98-04189A 1

DB39-00223A
Wire kit 1
(MRW-10A)

Samsung Electronics 2-7

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 7 search engine 2011-04-08 �� 10:54:33
Product Specifications

Accessories (cont.)

■ Wireless Remote controller

Item Descriptions Code-No. Q'TY Remark

DB93-00251G
Wireless remote controller 1
(ARH-401)

Batteries for remote controller


DB47-90024A 2
(specification: "AAA" type)

Remote controller holder DB61-00204A 1

Optional

STS 2S-2x10 Tapped Screw 6002-000581 2

User’s manual DB98-05156A 1

Installation manual DB98-05184A 1

2-8 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 8 search engine 2011-04-08 �� 10:54:34
Product Specifications

Accessories (cont.)

■ Wireless Remote Controlle

Item Descriptions Code-No. Q'TY Remark

DB93-04858C
Wireless remote controller 1
(MR-BH01)

Batteries for remote controller


DB47-90024A 2
(specification: "AAA" type)

Remote controller holder DB61-03147A 1

Optional

STS 2S-2x10 Tapped Screw 6002-000581 2

User’s manual DB98-27999A 1

Installation manual DB98-27997A 1

Samsung Electronics 2-9

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 9 search engine 2011-04-08 �� 10:54:34
Product Specifications

Accessories (cont.)

■ Wireless remote controller

Item Descriptions Code-No. Q'TY Remark

DB97-14333C
Wired remote controller 1
(MWR-WH02)

Cable tie DB65-10088B 2

Cable clamp DB65-10074E 5

M4×16 Tapped Screw 6002-000474 7

Indoor unit power drawing cable DB39-00221A 1 Optional

Communication cable of thewired remote


DB39-00933A 1
controller

Wire joint DB39-90020A 1

User’s manual DB98-25179A 1

Installation manual DB98-25180A 1

2-10 Samsung Electronics

Downloaded from
2-12
www.Manualslib.com manuals search engine
Samsung Electronics
NS090SDXEA_E_SM_33623A(1)_1.indd 10 2011-04-08 �� 10:54:35
Product Specifications

Accessories (cont.)

■ Centralized controller

Item Descriptions Code-No. Q'TY Remark

DB93-03425C
Centralized controller 1
(MCM-A202)

Cable tie DB65-10088B 2

Cable clamp DB65-10074E 5

Optional

M4x16 Tapped Screw 6002-000474 7

User’s manual DB98-12721A 1

Installation manual DB98-25773A 1

Samsung Electronics 2-11

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 11 search engine 2011-04-08 �� 10:54:36
Product Specifications

Accessories (cont.)

■ Function controller

Item Descriptions Code-No. Q'TY Remark

DB97-01077A
Function controller 1
(MCM-A100)

Cable tie DB65-10088B 2

Cable clamp DB65-10074E 6


Optional

M4x16 Tapped Screw 6002-000474 7

User’s manual DB98-27317A 1

Installation manual DB98-27315A 1

■ Transmitter

Item Descriptions Code-No. Q'TY Remark

DB97-00647P
Transmitter 1
(MIM-B04A)

Transmitter power cable DB39-00378D 1 Optional

Transmitter communication cable DB39-00253D 1

2-12 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 12 search engine 2011-04-08 �� 10:54:36
Product Specifications

Accessories (cont.)

■ DMS(Date Management Server)

Item Descriptions Code-No. Q'TY Remark

DB93-03709B
DMS 1
(MIM-D00)

Cable tie DB65-10088B 2

Cable clamp DB65-10074D 2

M4x16 Tapped Screw 6002-000474 5 Optional

Bottom hook DB73-00320A 4

User’s manual DB98-27317A 1

Installation manual DB98-27315A 1

Samsung Electronics 2-13

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 13 search engine 2011-04-08 �� 10:54:36
3. Disassembly and Reassembly
 Necessary Tools

Item Remarks

+SCREW DRIVER

Adjustable Wrench
(8mm, 10mm, 13mm)

3-1 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 1 search engine 2011-04-08 �� 10:54:36
Operating Instructions and Installation
3-1 Indoor unit

No Parts Procedure Remark

1 Blower & Motor 1) After disassembling 16 places indicating


screws, detach Ass'y Cabi Bottom Blower.
(Use +Screw Driver)

2) Detach from Ass'y Control In the capacitor


connection wire between the Motor Fan and
housing connector.

3) After disassembling 2 places indicating screws,


detach the 2 Fan Case. (Use +Screw Driver)

Samsung Electronics 3-2

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 2 search engine 2011-04-08 �� 10:54:37
Disassembly and Reassembly

No Parts Procedure Remark

4) After disassembling 2 places indicating


screws, detach Fan Motor and Blower
from the set.

2 Control In 1) After disassembling 1 Indicating screw, detach


the Cover control. (Use +Screw Driver)

2) Detach the Motor-Fan and Sensor Connector


from the PCB.

3-3 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 3 search engine 2011-04-08 �� 10:54:38
Disassembly and Reassembly

No Parts Procedure Remark

3) Disassemble 4 indicating screws and detach


Control In from the set.

3 Drain Pan Work is possible when Disassembling the Ass'y


Cabi Bottom Blower.

1) Disassemble 7 indicating screws and detach


Ass'y Cabi Bottom Drain..

Samsung Electronics 3-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 4 search engine 2011-04-08 �� 10:54:39
Disassembly and Reassembly

No Parts Procedure Remark

1) Disassemble 4 indicating screws and detach


the Drain Pan. (Use +Screw Driver)
(2 screws each at left and right side).

4 Evap Work is possible when Disassembling the Ass'y


Drain Pan.

1) Disassemble 5 indicating screws to detach


Cover Pipe. (Use +Screw Driver)

3-5 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 5 search engine 2011-04-08 �� 10:54:40
Disassembly and Reassembly

No Parts Procedure Remark

2) Disassemble Sensor on the Evap.

3) Disassemble 4 indicating screws which are in


the near of Hanger Plate to detach the Evap.
(Use +Screw Driver)
(2 screws each at left and right side)

 needs 2 peoples..


It

Samsung Electronics 3-6

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 6 search engine 2011-04-08 �� 10:54:41
3-2 Outdoor Unit

 RC090DH*/RC090SH*/RC100DH*/RC100SH*
No Parts Procedure Remark

1 Cabi Front RH  must turn off the Power before


You
disassembly.

1) Unscrew and remove two mounting screw


in the Cabinet Front RH. (Use +Screw Driver)

2 Cabi Top 1) Unscrew and remove 9 screws


on each side of the Cabinet-Top.
(Use +Screw Driver)

3 Cabi Install Front 1) Unscrew and remove 1 screw


in the Cabinet-Install Front.
(Use +Screw Driver)

3-7 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 7 search engine 2011-04-08 �� 10:54:41
Disassembly and Reassembly

No Parts Procedure Remark

4 Guard Cond 1) Pull the sensor from Guard Cond.

2) Unscrew and remove 4 screws


in the Guard Cond.
(Use +Screw Driver)

5 Cabi Back RH 1) Pull the sensor from Cabi Back RH.

2) Unscrew and remove 4 screws


on each side of the Cabinet Back RH.
(Use +Screw Driver)

Samsung Electronics 3-8

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 8 search engine 2011-04-08 �� 10:54:42
Disassembly and Reassembly

No Parts Procedure Remark

6 Cabi Install Back 1) Unscrew and remove 1 screw


in the Cabinet-Install Back.
(Use +Screw Driver)

7 Cabi Front LF 1) Unscrew and remove 10 screws


in the Cabinet-Front LF.
(Use +Screw Driver)

3-9 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 9 search engine 2011-04-08 �� 10:54:42
Disassembly and Reassembly

No Parts Procedure Remark

8 Fan 1) Turn 2 mounting nuts as shown in the


picture and remove it. (Use Adjustable
Wrench)

Samsung Electronics 3-10

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 10 search engine 2011-04-08 �� 10:54:42
Disassembly and Reassembly

No Parts Procedure Remark

9 Motor 1) Separate the Fan Propeller.


2) Unscrew and remove the 8 Motor mounting
screws. (Use +Screw Driver)

3) Disconnect the Motor wire From


Ass'y Control Out.

10 Bracket Motor 1) Unscrew and remove 2 mounting screws


in Bracket Motor. (Use +Screw Driver)

3-11 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 11 search engine 2011-04-08 �� 10:54:43
Disassembly and Reassembly

No Parts Procedure Remark

11 Control Out 1) Disconnect 4 Connecters From


Ass'y Control Out.

2) Unscrew and remove 1 mounting screw


in Control Out. (Use +Screw Driver)
3) Separate Ass'y Control Out.

Samsung Electronics 3-12

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 12 search engine 2011-04-08 �� 10:54:44
Disassembly and Reassembly

No Parts Procedure Remark

12 Ass'y 4way Valve 1) Purge the Coolant first.


2) Unscrew and remove 2mounting screws
in muffler.
3) Unscrew and remove 2 mounting screws
in Service Valve. (Use +Screw Driver)

4) Separate the pipe from the Entrance/Exit


using a welder.


When removing the compressor,
Heat Exchanger, and Pipe, purge the
Coolant inside the Compressor
completely and remove the pipe
with a welding flame.

3-13 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 13 search engine 2011-04-08 �� 10:54:44
Disassembly and Reassembly

No Parts Procedure Remark

13 Ass;y EEV Valve 1) Unscrew and remove 2 mounting screws


in Service Valve. (Use +Screw Driver)

2) Separate the pipe from the Entrance/Exit


using a welder.

14 Compressor 1) Unscrew and remove 1 mounting nut


in Cover Terminal. (Use Adjustable Wrench)

2) Separate the Compressor Felt Sound.

Samsung Electronics 3-14

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 14 search engine 2011-04-08 �� 10:54:45
Disassembly and Reassembly

No Parts Procedure Remark

3) As shown in the picture, unscrew and


remove 3 mounting screws from the
bottom. (Use Adjustable Wrench)

15 Cond Out 1) Unscrew and remove 3 screws


on each side of the Assy Cond Out.
(Use +Screw Driver)

2) Separate the Compressor Felt Sound.

3-15 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 15 search engine 2011-04-08 �� 10:54:46
Disassembly and Reassembly

 RC125DH*/RC140DH*

No Parts Procedure Remark

1 Cabi Front RH  must turn off the Power before


You
disassembly.
1) Unscrew and remove 2 mounting screw
in the Cabinet Front RH.
(Use +Screw Driver)

2 Cabi Top 1) Unscrew and remove 9 screws


on each side of the Cabinet-Top.
(Use +Screw Driver)

3 Cabi Install Front 1) Unscrew and remove 1 screw


in the Cabinet-Install Front.
(Use +Screw Driver)

Samsung Electronics 3-16

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 16 search engine 2011-04-08 �� 10:54:47
Disassembly and Reassembly

No Parts Procedure Remark

4 Guard Cond 1) Pull the sensor from Guard Cond.

2) Unscrew and remove 4 screws


in the Guard Cond.
(Use +Screw Driver)

5 Cabi Back RH 1) Pull the sensor from Cabi Back RH.

2) Unscrew and remove 4 screws


on each side of the Cabinet Back RH.
(Use +Screw Driver)

3-17 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 17 search engine 2011-04-08 �� 10:54:48
Disassembly and Reassembly

No Parts Procedure Remark

6 Cabi Install Back 1) Unscrew and remove 1 screw


in the Cabinet-Install Back.
(Use +Screw Driver)

7 Cabi Front LF 1) Unscrew and remove 10 screws


in the Cabinet-Front LF.
(Use +Screw Driver)

Samsung Electronics 3-18

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 18 search engine 2011-04-08 �� 10:54:49
Disassembly and Reassembly

No Parts Procedure Remark

8 Fan 1) Turn 2 mounting nuts as shown in the


picture and remove it. (Use Adjustable
Wrench)

3-19 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 19 search engine 2011-04-08 �� 10:54:49
Disassembly and Reassembly

No Parts Procedure Remark

9 Motor 1) Separate the Fan Propeller.


2) Unscrew and remove the 8 Motor mounting
screws. (Use +Screw Driver)

3) Disconnect the Motor wire From


Ass'y Control Out.

10 Bracket Motor 1) Unscrew and remove 2 mounting screws


in Bracket Motor. (Use +Screw Driver)

Samsung Electronics 3-20

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 20 search engine 2011-04-08 �� 10:54:50
Disassembly and Reassembly

No Parts Procedure Remark

11 Control Out 1) Disconnect 4 Connecters From


Ass'y Control Out.

2) Unscrew and remove 1 mounting screw


in Control Out. (Use +Screw Driver)
3) Separate Ass'y Control Out.

3-21 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 21 search engine 2011-04-08 �� 10:54:51
Disassembly and Reassembly

No Parts Procedure Remark

12 Ass'y 4way Valve 1) Purge the Coolant first.


2) Unscrew and remove 2 mounting screws
in Service Valve. (Use +Screw Driver)

3) Separate the pipe from the Entrance/Exit


using a welder.


When removing the compressor,
Heat Exchanger, and Pipe, purge the
Coolant inside the Compressor
completely and remove the pipe
with a welding flame.

13 Ass;y EEV Valve 1) Unscrew and remove 2 mounting screws


in Service Valve. (Use +Screw Driver)

2) Separate the pipe from the Entrance/Exit


using a welder.

Samsung Electronics 3-22

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 22 search engine 2011-04-08 �� 10:54:52
Disassembly and Reassembly

No Parts Procedure Remark

14 Compressor 1) Unscrew and remove 1 mounting nut


in Cover Terminal. (Use Adjustable Wrench)

2) Separate the Compressor Felt Sound.

3) As shown in the picture, unscrew and


remove 3 mounting screws from the
bottom. (Use Adjustable Wrench)

3-23 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 23 search engine 2011-04-08 �� 10:54:53
Disassembly and Reassembly

No Parts Procedure Remark

15 Cond Out 1) Unscrew and remove 3 screws


on each side of the Assy Cond Out.
(Use +Screw Driver)

Samsung Electronics 3-24

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 24 search engine 2011-04-08 �� 10:54:54
4. Troubleshooting

4-1 Indoor Display Error and Check Method

■ Error detection and reoperation


▶ If error occurs during the operation, badness is indicated by LED flickering and all operation is stopped except LED.
▶ When reoperating by remote control and switch determine the error mode after normal operation.

■ Indoor unit LED lamp display at error detecting


LED Iamp display
Operation Defrost Timer Air flow Filter
Error type Remarks

Power reset ◑ X X X X
Error of temperature sensor in the indoor unit(Open/Short) X X ◑ X X
Error of heat exchanger sensor in the indoor unit ◑ X ◑ X X
Error of the outdoor temperature sensorError of the condensor
temperature sensor ◑ X X ◑ X
Error of the discharge temperature sensorPower reset

1. No communication for 2 minutes between indoor units


(Communication error for more than 2 minutes)
2. Indoor unit receiving the communication error from
outdoor unit
3. Outdoor unit tracking 3 minutes error X X ◑ ◑ X
4. When sending the communication error from the outdoor
unit, the mismatching of the communication numbers
and installed numbers after completion of tracking4.
(Communication error for more than 2 minutes)

1. Error of electronic expansion valve close


2. Error of electronic expansion valve open
3. 2'nd detection of high temperature cond
X X ◑ ◑ ◑
4. 2'nd detection of high temperature discharge
5. Error of reverse phase
6. Compressor down due to 6'th detection of freezing

Detection of the float switch X X X ◑ ◑

Error of setting option switches for optional accessories X X ◑ X ◑

EEPROM option error ◑ ◑ ◑ ◑ ◑

● : ON, ◑ : Flickering, X : OFF


※ If you turn off the air conditioner when the LED is flickering, the LED is also turned off.

4-1 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 1 search engine 2011-04-08 �� 10:54:54
Troubleshooting

4-1-1 Wired Remocon Error Display(COM2)


•If an error occurs, is displayed on the wired remote controller. If you would like to see an error code, press the Test button.

Display Explanation Remark


Indoor unit Communication Error

Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data


Communication Error
Indoor unit is not connected
Communication Error between Outdoor Main and Inverter Micom
(Occurred after 1 minute detection in Main and Inverter)
Indoor Temp. Sensor(Open/Short Error)
Indoor Unit Eva in Sensor(Open/Short Error) Indoor Sensor Error
Indoor Unit Eva in Sensor Separation
Outdoor Temp. Sensor Error(Open/Short Error)
COND Temp. Sensor Error(Open/Short Error)
Outdoor Sensor Error
Inverter Compressor Discharge Temp. sensor Error(Open/Short Error)
Power cable miss connection error
Indoor Float Switch 2nd Detection
Outdoor unit - indoor unit communication wire miss connection
(Connected to Power terminal)
Outdoor unit refrigerant Full leakage(Gas leak) Self Diagnosys Error

Outdoor Fan 1 Error


Outdoor Fan 2 Error
Discharge over temperature
[Inverter] Compressor starting error
Primary Current Over Trip error
[Inverter]IPM Over Current(O.C)
Outdoor UnitProtetion Control Error
[Inverter] Compressor Rotation error
[Inverter] Current Sensor error
[Inverter] DC LINK Sensor error
[Inverter] EEPROM Read/Write Error
[Inverter] Heatsink temperature over Error
Outdoor UnitProtetion Control Error
Outdoor unit Capacity Setup option error
Communication error between Indoor unit and wired remote control
Communication error between Master and Slave wired remote control
Wired remote control error
COM1/COM2 Cross-installed error
Error of setting option for wired remote control COM2

Samsung Electronics 4-2

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 2 search engine 2011-04-08 �� 10:54:56
4-2 Outdoor LED Error Display and Check Method

LED Display
No. Explanation Error Code
Yellow Green Red
1    Power off/ VDD NG -
2    IPM Over Current(O.C)
  
3 Abnormal Serial communication/Power Cable Miss Connection
  
4    Compressor Starting error
5    Normal Operation -
6    Compressor Lock error
7    DC-Link voltage under/over error
8    Outdoor temperature sensor error
9    Discharge over temperature
10    Discharge temperature sensor error
11    Current sensor error
12    Compressor Limit error
13    Coil temperature sensor error
14    1min. Time out Communication

15    Fan error

16    OTP error
17    Compressor rotation error

18    Operation condition secession

19    DC-Link voltage sensor error


20    I_Trip error
21    GAS Leak error
22    Power Cable miss connection
23    Power ON reset(1sec) -
24    Capacity miss match
25    Test Operation at Cooling Mode -
26    Test Operation at Heating Mode -
 Off  Blink  On

4-3 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 3 search engine 2011-04-08 �� 10:54:58
4-3 Setting Option Setup Method

4-3-1 Type A(Setting Option)

Option No. :

Step 1 : Enter the Option Setup mode.

1st Take out the batteries of remote control.

Press the temperature button simultaneously


2nd
and insert the battery again.

3rd Make sure the remocon display shown as .

Step 2 : Enter the Option Setup mode and select your option according to the following procedure.

1
The default value is .
Otherwise, push the button to .
Every time you push the button, the display panel reads or repeatedly.

2
1 Push the button to set the display panel to .
2 Every time you push the button, the display panel reads    . . .
3        repeatedly.

4
3
Push the button to set the display panel to .
Every time you push the button, the display panel reads    . . .
5
       repeatedly.
6

4
Push the button to set the display panel to .
Every time you push the button, the display panel reads    . . .
       repeatedly.

5
Push the button to set the display panel to .
Every time you push the button, the display panel reads    . . .
       repeatedly.

6
Push the button to set the display panel to .
Setting is not required if you must
a volue which has a default. Every time you push the button, the display panel reads    . . .
       repeatedly.

Samsung Electronics 4-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 4 search engine 2011-04-08 �� 10:55:05
Troubleshooting

7
Press button, then the default value is .

8
7 Push the button to set the display panel to .
8 Every time you push the button, the display panel reads    . . .
9        repeatedly.

9
10 Push the button to set the display panel to .
Every time you push the button, the display panel reads    . . .
11        repeatedly.
12
10
Push the button to set the display panel to .
Every time you push the button, the display panel reads    . . .
       repeatedly.

11
Push the button to set the display panel to .
Every time you push the button, the display panel reads    . . .
       repeatedly.

12
Push the button to set the display panel to .
Setting is not required if you must
a volue which has a default. Every time you push the button, the display panel reads    . . .
       repeatedly.

Step 3 : Upon completion of the selection, check you made right selections.
Press the Mode Selection key, to set the display part to and check the display part.

The display part shows .

Press the Mode Selection key, to set the display part to and check the display part.

The display part shows .

Step 4 : Pressing the ON/OFF button( ).


When pressing the operation ON/OFF key with the direction of remote control for unit, the sound ’’Ding’’ or
’’Diriring’’ is heard and the OPERATION ICON( ) lamp of the display is flickering at the same time, then the input
of option is completed. (If the diriring sound isn’t heard, try again pressing the ON/OFF button.)
Step 5 : Unit operation test-run.
First, Remove the battery from the remote control.
Second, Re-insert the battery into the remote control.
Third, Press ON/OFF button( ) withthe direction of remote control for set.

• Error Mode
1st If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry.
If the unit is not working properly or all lamps are continuously flickering after setting the option code, see
2nd
if the correct option code is set up for its model.

4-5 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 5 search engine 2011-04-08 �� 10:55:14
Troubleshooting

4-3-2 Type B(Setting Option Setup Method)

Operation method Applicable button Indicating state

■Step 1
Method)
① Remove the battery of remote controller.
② Push the Off Timer and Cancel button
simultaneously.
③ Insert the battery.

Result)
When the display of remote controller
is indicated as shown in the right,
then go to the step 2.

■Step 2
Method)
If the first digit of remote controller
shows "0", go to the step 3.
• If it shows 1, press the Mode button one
time to change it into 0 and
then go to step 3.

■Step 3
Method)
Input the second digit of option code
by pressing the High Temp button.
example) 021E311422852A311439421F

Result)
If 2 is displayed, go to the step 4
(whenver pressing the button, 1~9,
A,B,C,D,E,F are lit in order.)

Samsung Electronics 4-6

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 6 search engine 2011-04-08 �� 10:55:15
Troubleshooting

Operation method Applicable button Indicating state

■Step 4
Method)
Input the third digit of option code by
pressing the Low Temp button.
example) 021E311422852A311439421F

Result)
If 1 is displayed, go to the step 5.

■Step 5
Method)
Input the third digit of option code by
pressing the High Fan button.
example) 021E311422852A311439421F

Result)
If E is displayed, go to the step 6.

■Step 6
Method)
Input the third digit of option code by
pressing the On Timer button.
example) 021E311422852A311439421F

Result)
If 3 is displayed, go to the step 6.

4-7 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 7 search engine 2011-04-08 �� 10:55:16
Troubleshooting

Operation method Applicable button Indicating state

■Step 7
Method)
Input the sixth digit by pressing the Cancel
button.
example) 021E311422852A311439421F

Result)
If 1 is displayed, go to the step 8.

■Step 8
Method)
After completion up to step 7, pressing
Mode button.

① 1~7 steps are saved internally.


② If the first number is 1 at the time,
it is correct. So go to step 9.
• If wanting to see the screen of 2~7 steps,
press the mode button repeatedly
to make the first digit 0.

■Step 9
Method)
Input the eighth digit by pressing the
High Temp button.
example) 021E311422852A311439421F

Result)
If 4 is displayed, go to the step 10.

Samsung Electronics 4-8

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 8 search engine 2011-04-08 �� 10:55:17
Troubleshooting

Operation method Applicable button Indicating state

■Step 10
Method)
Input the ninth digit by pressing the
Low Temp button.
example) 021E311422852A311439421F

Result)
If 2 is displayed, go to the step 11.

■Step 11
Method)
Input the tenth digit by pressing the
High Fan button.
example) 021E311422852A311439421F

Result)
If 2 is displayed, go to the step 12.

■Step 12
Method)
Input the 11st digit by pressing the
On Timer button.
example) 021E311422852A311439421F

Result)
If 8 is displayed, go to the step 13.

4-9 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 9 search engine 2011-04-08 �� 10:55:18
Troubleshooting

Operation method Applicable button Indicating state

■Step 13
Method)
Input the 12th digit by pressing the Cancel
button.
example) 021E311422852A311439421F

Result)
If 5 is displayed, go to the step 14.

■Step 14
■Error
Method)
After completion up to step 13, pressing
① If the On/Off, Timer and Fan indicator
Mode button.
is flickering, the wrong option code
is input. Put off the power of
indoor unit and turn it on again
① Previous steps are saved internally.
and then input the option code again.
② If the first number is 2 at the time,
If the same error occurs, it is the
it is correct. So go to step 15.
EEPROM is defective or not inserted.
• If wanting to see previous screen, press
Replace the PCB.
the mode button repeatedly to
② If all of On/Off, Timer, Fan and Filter
make the first digit to with digit.
Sign indicator are flickering along with
the "Tiriring" sound, there is
option code already input which are
different from the current ones.
Check the option code and press
the button again if correct.
Option code will be input.
(Check the option code correctly.
At the time, if the same error
continues to occur, the
option code is out of input range.
Check the option code again and
repeat the step 1~14.

Samsung Electronics 4-10

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 10 search engine 2011-04-08 �� 10:55:18
Troubleshooting

Operation method Applicable button Indicating state

■Step 15
Method)
Input the 14th digit by pressing the
High Temp button.
example) 021E311422852A311439421F

Result)
If A is displayed, go to the step 16.

■Step 16
Method)
Input the 15th digit by pressing the Low
Temp button.
example) 021E311422852A311439421F

Result)
If 3 is displayed, go to the step 17.

■Step 17
Method)
Input the 16th digit by pressing the
High Fan button.
example) 021E311422852A311439421F

Result)
If 1 is displayed, go to the step 18.

4-11 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 11 search engine 2011-04-08 �� 10:55:19
Troubleshooting

Operation method Applicable button Indicating state

■Step 18
Method)
Input the 17th digit by pressing the On Timer
button.
example) 021E311422852A311439421F

Result)
If 1 is displayed, go to the step 19.

■Step 19
Method)
Input the 18th digit by pressing the
Cancel button.
example) 021E311422852A311439421F

Result)
If 4 is displayed, go to the step 20.

■Step 20
Method)
After completion up to step 20, pressing
Mode button.

① Previous steps are saved internally.


② If the first number is 3 at the time,
it is correct. So go to step 22.
• If wanting to see previous screen, press
the mode button repeatedly to
make the first digit to with digit.

Samsung Electronics 4-12

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 12 search engine 2011-04-08 �� 10:55:20
Troubleshooting

Operation method Applicable button Indicating state

■Step 21
Method)
Input the 20th digit by pressing the
High Temp button.
example) 021E311422852A311439421F

Result)
If 9 is displayed, go to the step 22.

■Step 22
Method)
Input the 21th digit by pressing the Low
Temp button.
example) 021E311422852A311439421F

Result)
If 4 is displayed, go to the step 23.

■Step 23
Method)
Input the 22th digit by pressing the
High Fan button.
example) 021E311422852A311439421F

Result)
If 2 is displayed, go to the step 24.

4-13 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 13 search engine 2011-04-08 �� 10:55:21
Troubleshooting

Operation method Applicable button Indicating state

■Step 24
Method)
Input the 23th digit by pressing the On Timer
button.
example) 021E311422852A311439421F

Result)
If 1 is displayed, go to the step 25.

■Step 25
Method)
Input the 24th digit by pressing the
Cancel button.
example) 021E311422852A311439421F

Result)
If F is displayed, go to the step 26.

■Error
■Step 26
① If the On/Off, Timer and Fan indicator
Method)
is flickering, the wrong option code
Turn the remote controller toward the indoor
is input. Put off the power of
unit and press the Power button, and if the
indoor unit and turn it on again
"Ting" or "Tiriring" sounds, the input of option
and then input the option code again.
is completed.
If the same error occurs, it is the
EEPROM is defective or not inserted.
Replace the PCB.
② If all of On/Off, Timer, Fan and Filter
• If error displays, solve the problem with
Sign indicator are flickering along with
reference to the right side.
the "Tiriring" sound, there is
option code already input which are
different from the current ones.
Check the option code and press
the button again if correct.
Option code will be input.
(Check the option code correctly.
At the time, if the same error
continues to occur, the
option code is out of input range.
Check the option code again and
repeat the step 1~26.

Samsung Electronics 4-14

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 14 search engine 2011-04-08 �� 10:55:21
Troubleshooting

Operation method Applicable button Indicating state


■Error
■Step 27
① If the On/Off, Timer and Fan indicator
Method)
is flickering, the wrong option code
If the steps 1 to 26 are completed, remove
is input. Put off the power of
the battery and insert it again to return to
indoor unit and turn it on again
the original display of remote controller.
and then input the option code again.
(Operation mode/SET TEMP. /fan speed
If the same error occurs, it is the
displays.)
EEPROM is defective or not inserted.
Replace the PCB.
② If all of On/Off, Timer, Fan and Filter
Sign indicator are flickering along with
• If error displays, solve the problem with
the "Tiriring" sound, there is
reference to the right side.
rear side option code already input which are
different from the current ones.
Check the option code and press
the button again if correct.
Option code will be input.
(Check the option code correctly.
At the time, if the same error
continues to occur, the
option code is out of input range.
Check the option code again and
repeat the step 1~26.

◆ If you are going to use up to SEG 24, please refer to following instruction.
SEG 17 : 0 1 : Using high ceiling kit for 4way.
SEG 18 :
Not in use Use
Change temperature display 0(Celsius) 1(Fahrenheit)
Sound Mute 0 2
Mixed operation control 0 4

◆ If you want to use multiple functions, add each of the ‘use’ value of the function you want to used and input the
final addition as option value.
(Use Fahrenheit + Sound mute + Mixed operation control : 1 + 2 + 4 = 7)
Ex) 044217-1d00e6-200000-300000When using Sound mute : 044217-1d00e6-200002-300000
When using high ceiling kit for 4way and mixed operation error preventing function : 044217-1d00e6-200014-300000

4-15 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 15 search engine 2011-04-08 �� 10:55:22
Troubleshooting

4-3-3 Option code for each model

Model SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12

Remocon
display

NS100SSXEA 0 1 1 0 4 4 1 5 6 2 9 9
NS090SDXEA 0 1 1 0 4 4 1 5 6 2 9 9
NS090SSXEA 0 1 1 0 4 4 1 5 6 2 9 3
NS090SSXEX 0 1 1 0 4 4 1 5 6 2 9 3
NS125SDXEA 0 1 1 0 4 4 1 5 7 0 F 8
NS140SDXEA 0 1 1 0 4 4 1 6 7 2 0 8
Model SEG13 SEG14 SEG15 SEG16 SEG17 SEG18 SEG19 SEG20 SEG21 SEG22 SEG23 SEG24

Remocon
display

NS100SSXEA 2 7 5 A 6 4 3 5 0 0 0 0
NS090SDXEA 2 7 5 A 6 4 3 5 0 0 0 0
NS090SSXEA 2 7 5 A 6 4 3 7 0 0 0 0
NS090SSXEX 2 7 5 A 6 4 3 7 0 0 1 0
NS100SDXEA 2 7 6 4 7 0 3 7 0 0 0 0
NS125SDXEA 2 7 7 D 8 C 3 7 0 0 0 0
NS140SDXEA 2 7 8 C A 0 3 7 0 0 0 0

Samsung Electronics 4-16

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 16 search engine 2011-04-08 �� 10:55:29
4-4 Iterms to be checked first

1. The input voltage should be rating voltage ±10% range.


The air conditioner may not operate properly if the voltage is out of this range.

2. Is the link cable linking the indoor unit and the outdoor unit linked properly?
The indoor unit and the outdoor unit shall be linked by 4 cables.
Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables.
Otherwise the air conditioner may not operate properly.

3. When a problem occurs due to the contents illustrated in the table below it is a symptom not related to the
malfunction of the air conditioner.

No Operation of air conditioner Explanation


1 In a COOL operation mode, the compressor does not In happens after a delay of 3 minutes when the
operate at a room temperature higher than the setting compressor is reoperated.
temperature that the INDOOR FAN should operate. The same phenomenon occurs when a power is
[In case of heat pump model] on.
In a HEAT operation mode, the compressor does not As a phenomenon that the compressor is
operate at a room temperature lower than the setting reoperated after a delay of 3 minutes, the
temperature that indoor fan should operate. indoor fan is adjusted automatically with
reference to a temperature of the air blew.
2 Compressor stops operation intermittently in Compressor operation is controlled automatically
DRY( ) mode. in DRY mode depending on the room temperature
and humidity.

3 [In case of heat pump model] When the unit is turned off while de-ice is
Compressor of the outdoor unit is operating although activated, the compressor continues operation
it is turned off in a HEAT mode. for up to 12 minutes(maximum) until the deice
is completed.

4 [In case of heat pump model] The compressor and indoor fan stop intermittently
The compressor and indoor fan stop intermittently if room temperature exceeds a setting
in HEAT mode. temperature in order to protect the compressor
from overheated air in a HEAT mode.

5 [In case of heat pump model] The compressor operates in a reverse cycle to
Indoor fan and outdoor fan stop operation remove exterior ice in a HEAT mode, and
intermittently in a HEAT mode. indoor fan and outdoor fan do not operate
intermittently for within 20% of the total heater
operation.

4-17 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 17 search engine 2011-04-08 �� 10:55:29
4-5 Fault Diagnosis by Symptom

4-5-1 No Power(completely dead) - Initial diagnosis


1. Checklist :
1) Is Power source voltage normal?
2) Is AC power linked correctly? ( miss-wiring, wire detaching etc. )
3) Is any LED on the MAIN PCB of Outdoor unit lit?
4) Is terminal voltage for indoor unit normal? (230Vac nominal)
5) Is Wired remote controller installed correctly?

2. Troubleshooting procedure

Turn off the breaker and turn it on after 30 seconds

Check outdoor unit terminal No


block voltage on each N-R,N-S,N-T Check AC power source. Reconnect wires correctly.
(230Vac nominal)

Yes

Check outdoor unit terminal No


block voltage on L-N for indoor unit Check Inner wiring of outdoor unit.
(230Vac nominal)

Yes

Check indoor unit terminal No Check cable and connection of wire between
block voltage on L-N indoor and outdoor unit.
(230Vac nominal)

Yes

Check indoor unit terminal No Check Indoor control PCB, Transformer,


block voltage on V1-V2 and FUSE on PCB and replace one which is broken.
(12Vdc nominal)

Yes

Check DC power voltage of remote No Check cable and connection of wire between
controller(V1,V2) remote controller and indoor unit.

Yes

Press the On/Off button on


No
the wired remote controller to operate the Replace wired remote controller.
air conditioner

Yes

No
Check DIP SW in the wired remote controller Set DIP SW correctly.

Yes

Is there any error display on the wired No


Check each item according to error code list.
remote controller
No

Check the setting temperature

Samsung Electronics 4-18

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 18 search engine 2011-04-08 �� 10:55:29
Troubleshooting

4-5-2 The Outdoor unit Power Supply error


1. Checklist :
1) Are the input power voltage and power connection correct?
2) Is there any Fuse Short of the indoor or outdoor unit?
3) Is any LED lit on both MAIN PCB and INVERTER PCB?
4) Are Reactor wires of the outdoor unit connected correctly?

2. Troubleshooting procedure

Check LEDs on both MAIN PCB and


INVERTER PCB after1 minutesfrom Is voltage on N-T of terminal Yes
power on Check and correct the power cable wiring
block over 300V?

No
MAIN PCB INVERTER PCB
Are wire and socket connected
correctly? Power line N and No Check and correct the wire or socket
T wire(Terminal block - connection
reactor - EMI PCB), CN9(EMI PCB),
CN80(MAIN PCB)
ALL OFF ALL OFF
Yes Check Fuses listed blow FUSE3(EMI PCB),
FUSE(MAIN PCB)

Yes Correct the cable wiringbetween indoor and


Is there miss connection of outdoor
power andcommunication wire
Error 202 display betweenindoor and outdoor?
Normal
(Table No. 14)
No
Check F1,F2 communication line wiring.
CN50(MAIN PCB)

Is there any power wire Yes


detachingespecially Check and correct the power cable wiring
Error 425 display phase R and S?
ALL OFF
(Table No. 22) No Check Fuses listed blow FUSE1(EMI PCB),
FUSE2(EMI PCB)

Are wire and socket connected No


correctly? CN31(MAIN PCB), Check and correct the wiring
CN10(INVERTER PCB)
Error 203 display Yes
ALL OFF
(Table No. 3)
Is the FUSE on INVERTER PCB Yes
blown? Replace the FUSE

No

Is R100 on INVERTER PCB Yes


Replace INVERTER PCB
open?(200ohm moninal)
Error 466 display Error 466 display
(Table No. 7) (Table No. 7) No

Check INVERTER PCB Also check each BLDC FAN motoshort or not,
by resistance betweenpin #1 and #3

No
Error 469 display Error 469 display Are wire and socket connected Check and correct the wiring
correctly? CN05,06,07 TAB
(Table No. 19) (Table No. 19) terminal(EMI PCB),
CN20(INVERTER PCB)
Yes
Check the M/C

4-19 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 19 search engine 2011-04-08 �� 10:55:29
Troubleshooting

4-5-3 The Outdoor unit Fan error


1. Checklist :
1) Are the input power voltage and power connection correct?
2) Is the motor wire connected to the outdoor PCB correctly?
3) Is there no obstacle at the surrounding of motor and propeller?
4) Does the driver in the motor case broken?

2. Troubleshooting procedure

Is the connection of FAN housing certainly to No


Check AC power source. Reconnect wires correctly
PCB socket?(CN40, CN41)
Yes

Take off each Fan motor housing after 1 minutes from


turning off the power

Is each resistance of FAN cable housing pin #1-#3 over No Exchange the FAN motor because of driver inside
1Mohm, pin #4-#3, #5-#3 and #6-#3 over 1Kohm on of the motor case broken
each FAN motor?
Yes # TEST operation #
press K900 button on the
Mount each Fan housing to PCB socket and turn MAIN PCB after power on.
on the power - once : cooling mode
- twice in a second : heating mode

No Follow the check procedure of outdoor unit power


Is the Pin voltage #1 - #3 of CN40 and 41over 250V?
supply error check
Yes

No
Is the Pin voltage #5 - #3 of CN40 and 41 15V? Exchange INVERTER PCB

Yes

Is the Pin voltage #5 - #3 of CN40 and 41within 1-6V No


Exchange INVERTER PCB
during the operation?
Yes

Is the Fan in rotation during TEST operation in No


Exchange the FAN motor not in rotation
cooling mode

Yes

Is the Pin voltage #6 - #3 of CN40 and 41changed Yes


high(4-5V) and low(0-1V) in case ofmaking manual Exchange INVERTER PCB
rotation slowly?

No

Is the Pin voltage #7 - #3 of CN40 and 41 low(0-1V) in No


Exchange the FAN motor
normal rotation?

Yes
Exchange the FAN motor

Samsung Electronics 4-20

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 20 search engine 2011-04-08 �� 10:55:29
Troubleshooting

4-5-4 Total current trip error


1. Checklist :
1) Is the input power voltage proper?
2) Is the refrigerant charged properly?
3) Does the compressor rotate normally?(Reverse rotation, Locking etc.)
4) Does the outdoor fan operate normally?(Fan propeller loss, Motor error ect.)
5) Is the installation condition of outdoor unit good?(Piping, Space etc.)
6) Is there no ventilation obstruction at the surrounding of outdoor unit?(Outdoor unit cover, Fan front obstruction etc.)
7) Is there no ventilation obstruction at the surrounding of indoor unit?(Overload condition in heating mode)

2. Troubleshooting procedure

No
Is the installation of outdoor unit good? Reinstall and remove the obstruction

Yes

Is the installation of indoor unit good? No Reinstall and remove the obstruction

Yes

Does the compressor rotate normally? No Exchange the compressor

Yes

Are the service valves full opened? No Open valve screw to the end

Yes

Is AC power voltage normal during No Check AC power source


thecompressor in operation?

Yes
Exchange INVERTER PCB

4-21 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 21 search engine 2011-04-08 �� 10:55:29
Troubleshooting

4-5-5 In case of heating at the cooling mode or cooling at the heating mode
1. Troubleshooting procedure

No
Is the Thermo off? Change the setting temperature of remote control

No

Is the unit in the defrosting Yes


Check Inner wiring of outdoor unit.
operation?
No

Yes
Is the compressorin 3 minutes off? After 3 minutes, coolingand heating start automatically

No

Is much frostin the indoor Yes Is the outdoor air sensor and No
outdoor heat exchanger Attach the sensor correctly
heat exchanger?
attachedcorrectly?

No Yes Over shortage of the


refrigerant

Does the 4-WAY valve Yes Is the 4-WAY valve No Connect the connecter
operate normally? connectorconnected correctly
correctly?

Yes

Check the resistance value of 4-WAY No


4-WAY valve coil error
valve coil

Yes

Dose thevoltage of
AC220V apply to the No
connector of Exchangethe outdoor PCB
4-WAY valve coil during
the operation?

Yes

Go to the next page 4-WAY valve main body error

Samsung Electronics 4-22

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 22 search engine 2011-04-08 �� 10:55:30
Troubleshooting

4-5-5 In case of heating at the cooling mode or cooling at the heating mode(cont.)

Go to the next page

Does theEEV No Is much frostin the heat No


Connect the connector.
operatenormally? exchanger?

Yes

Check the resistance value of No


EEV coil error
EEV coil

Yes

Yes Is much frostin the heat No


Exchangethe out PCB
exchanger?

Yes

EEV main body error

Doesthe outdoor fan Yes The over shortage of refrigerant, Insufficient Capacity,
operate at the operation Load estimation error
of compressor?

No

Is theoutdoor fan No
Connect the connector
connectedcorrectly?

Yes

Check the resistance value of No


Outdoor fan error
outdoor fan

Yes

Is theoutdoor fan Yes


Check the motor wire
connectedcorrectly?

No

Outdoor PCB error

4-23 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 23 search engine 2011-04-08 �� 10:55:30
Troubleshooting

4-5-6 Outdoor temperature sensor error


1. Checklist :
1) Is the sensor connector connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull_up correct?

2. Troubleshooting procedure

Is the sensor connector connectedcorrectly in


Reconnect the sensor connector
accordance with a color?

Yes
No
Is the temperature sensor connectedcorrectly
without separation?
Change the position of sensor
Yes

Does the both terminal of sensorsatisfy the No


resistance value in accordance with temperature?
No
(Refer to the R/T TABLE)
Exchange the sensor
Yes

No
Is the resistance valueof sensor connection
pull_up 18K? No
Exchange the PCB

Yes
Exchange the PCB Normal operation

Exit

400.0

350.0

300.0

250.0

200.0

150.0

100.0

50.0

0.0
-50
-41
-32
-23
-14
-5
4
13
22
31
40
49
58
67
76
85
94
103

Samsung Electronics 4-24

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 24 search engine 2011-04-08 �� 10:55:30
Troubleshooting

4-5-7 Discharge temperature sensor error


1. Checklist :
1) Is the sensor connector connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull_up correct?

2. Troubleshooting procedure

Is the sensor connector connectedcorrectly in


Reconnect the sensor connector
accordance with a color?

Yes
No
Is the temperature sensor connectedcorrectly
without separation?
Change the position of sensor
Yes

Does the both terminal of sensorsatisfy the No


resistance value in accordance with temperature?
No
(Refer to the R/T TABLE)
Exchange the sensor
Yes

No
Is the resistance valueof sensor connection
pull_up 24K? No
Exchange the PCB

Yes
Exchange the PCB Normal operation

Exit

600.0

500.0

400.0

300.0

200.0

100.0

0.0
0
8
16
24
32
40
48
56
64
72
80
88
96
104
112
120
128
136
144
152
160

4-25 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 25 search engine 2011-04-08 �� 10:55:30
Troubleshooting

4-5-8 Coil temperature sensor error


1. Checklist :
1) Is the sensor connector connected correctly?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull_up correct?

2. Troubleshooting procedure

Is the sensor connector connectedcorrectly in


Reconnect the sensor connector
accordance with a color?

Yes
No
Is the temperature sensor connectedcorrectly
without separation?
Change the position of sensor
Yes

Does the both terminal of sensorsatisfy the No


resistance value in accordance with temperature?
No
(Refer to the R/T TABLE)
Exchange the sensor
Yes

No
Is the resistance valueof sensor connection
pull_up 18.2K? No
Exchange the PCB

Yes
Exchange the PCB Normal operation

Exit

400.0

350.0

300.0

250.0

200.0

150.0

100.0

50.0

0.0
-50
-41
-32
-23
-14
-5
4
13
22
31
40
49
58
67
76
85
94
103

Samsung Electronics 4-26

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 26 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-9 Fan error


1. Checklist :
1) Isn’t the fan locked?
2) Is the sensor placed correctly?
3) Does the both terminal of sensor satisfy the resistance value in accordance with temperature?
4) Is the resistance value of sensor connection pull_up correct?

2. Troubleshooting procedure

Isn't the Fan locked? Remove the Fan lock

Yes
No
Is the connector connected correctly? No
Connect the connector
Yes

No
Is the color of Fan wire matched correctly?
Exchange the Fan

Yes
Exchange the PCB Normal operation

Exit

4-27 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 27 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-10 DC-Link voltage sensor error


1. Checklist :
1) Is the connection of R, S, T power wire normal?
2) Are Relay RY21 and R200 on the INVERTER PCB mounted normally?

2. Troubleshooting procedure

Are connection of the wire from INVERTER PBA to No


Check and correct the wire connection
EMI PBA normal?
Yes

Exchange INVERTER PCB

Samsung Electronics 4-28

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 28 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-11 O.C.(Over Cirrent) error


1. Checklist :
1) Is the refrigerant charged properly?
2) Does the compressor rotate normally?(Reverse rotation, Locking etc.)
3) Is connection of compressor wire normal?
4) Is compressor motor normal?(Insulation, Coil resistance etc.)
5) Does a temporary cycle overload condition happened?

2. Troubleshooting procedure

No
Is the installation of outdoor unit good? Reinstall and remove the obstruction

Yes

Is the installation of indoor unit good? No Reinstall and remove the obstruction

Yes

Are the service valves full opened? No Open valve screw to the end

Yes

Does the compressor wire connected to No Correct the compressor wire connection
the compressor normally?

Yes

Is insuration resistance between each compressor No Exchange the compressor


terminal and body normal?

Yes

No Exchange the compressor


Does the compressor rotate normally?

Yes

Did AC power voltage interruption happen during Yes Check AC power source
the compressor in operation?

No
Exchange INVERTER PCB

4-29 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 29 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-12 Communication error


1. Checklist :
1) Is the communication cable between the indoor unit and outdoor unit connected correctly?
2) Isn’t the power cable and communication cable wiring error?

2. Troubleshooting procedure

Restart after power off

Is the communication erroroccurred again? No Terminate the service

Yes

Isn't the power cable andcommunication No Correct the wrong wiring


cable wiring error?

Yes

Is the connection of communication cable normal? No Correct the compressor wire connection

Yes

Is insuration resistance between each compressor No Correct the connection of communication cable
terminal and body normal?

Yes

Exchange the outdoor unit PCB

Samsung Electronics 4-30

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 30 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-13 Compressor start error


1. Checklist :
1) Is the connection of cable for the compressor and power?
2) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

Restart after power off

Is the restart error occurred again? No Terminate the service

Yes

Is the interphase resistance value of compressor No Exchange the compressor


(u v, v w, w u) normal?

Yes

Is the compressor body and interphase No Exchange the compressor


resistance insulated?

Yes

Is the connection cable for thecompressor and No Correct the cable connection
power terminal normal?

Yes

Exchange the PCB

4-31 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 31 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-14 Compressor lock error


1. Checklist :
1) Is the connection of cable for the compressor and power?
2) Is the interphase resistance of compressor normal?

2. Troubleshooting procedure

Restart after power off

Is the lock error occurred again? No Terminate the service

Yes

Is the interphase resistance value ofcompressor No Exchange the compressor


(u v, v w, w u) normal?

Yes

Is the compressor body and interphase No Exchange the compressor


resistance insulated?

Yes

Is the connection cable for the compressor and No Correct the cable connection
power terminal normal?

Yes

Exchange the outdoor unit PCB

Samsung Electronics 4-32

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 32 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-5-15 DC Link Over voltage/Low voltage error


1. Checklist :
1) Is the power voltage normal?(Lightning, Power interruption etc.)
2) Is AC Power cable connection normal?(Detaching the wire)

2. Troubleshooting procedure

Is the AC Power cable connection to the No Check and reconnecting the AC power cable wire
outdoor unit terminal block good?

Yes

No Check and reconnecting the reactor wireat


Is the connection of reactor terminal good?
the TAB terminal

Yes

Are the FUSEs on EMI PCB blown? Yes Replace the blown FUSE

No

Push the center bar of M/C and mesure


the resis-tance of each contact

No Exchange M/C
Is each contact resistance normal? (less than 0.1ohm)

Yes

Yes Exchange INVERTER PCB


Does the error reappear frequently

No

The cause of this error may be power source trouble


as like power interruption.Check the power source

4-33 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 33 search engine 2011-04-08 �� 10:55:31
4-6 PCB Inspection Method

4-6-1 Pre-inspection Notices


1. Turn off the breaker, AC power source, before disassembling the unit because of electrical hazard.
2. Confirm the complete discharge of capacitor C102, C702, C703, C704, C705, C706, C707 on the INVERTER PCB when you touch
the PCB. Especially dischargeing speed of C702-C707 is very slow because of little load in stand-by condition. To confirm
the voltae of 702-C707, measure the DC link voltage at the IGBT module pins near C701 at which applying voltage (450-510Vdc) is
marked. To confirm discharging of C102, measure the voltage of non mounted C103 solder hole or check if all LEDs are off.
3. Don’t touch the metal body of electrolytic capacitor for avoiding electrical shock before confirming discharge.
4. To discharging the capacitor use power resistor of about 1 Kohm 10W. Soldering tool(non electronic temperature control type)
can be used as a discharging resistor.
5. Don’t pull the lead wire but hold the whole housing to disconnect or connect a housing from or to the PCB.

4-6-2 Inspection Procedure


1. Check the connection of each housing to the connector first and the peeling of PCB copper pattern.
2. The PCB is composed of the 3 part in the indoor unit.
● INDOOR Main PCB part : Indoor unit control, MICOM and surrounding circuit, relay, fan motor driving circuit, sensor reading
circuit, buzzer driving circuit and DC power supplying circuit.
● Display PCB part : LED lamps, Switch,Remocon module.
● INDOOR EMI PCB part : Line filter, Noise Capacitor and Varistor
3. The PCB is composed of the 3 part in the outdoor unit.
● EMI PCB part : Line filter for electrical noise, Varistors for surge and Fuses.
● MAIN PCB part : Refrigeration cycle controller with MICOM
● INVERTER PCB part : Compressor driving inverter and BLDC fan controller

4-6-3 Indoor Detailed Inspection Procedure


No Procedure Inspection Method Cause
Open the electronic Turn off the power •Over current
component box and 1) Is the Fuse F701 on the EMI PCB blown? •Indoor fan motor short
1
check the PCB fuse 2) Is the Fuse F702 on the MAIM PCB blown? •PCB AC Part pattern short

Check the LEDs for Turn off the power •Communication ciucuit trouble
DC power and 1) Is RED LED blinking? •Communication wire
communication condition his led means micom is running normally connection trouble
2) Is GREEN LED blinking? •Wrong connection for
This means communication between power supply wire of
2 Indoor and Outdoor unit is on remote controller
3) Is YELLOW LED blinking?
This means communication between
Indoor and wired remote controller is on
It may take one minute to start
communication

Check the DIP and rotary 1) Is the setting of each switch proper? •Wrong setting of switch
3 switch on the PCB

Check the DC voltage 1) Is the voltage of CN32 pin #1-#2 12V? •SMPS on MAIN PBA trouble
4 2) Is the voltage of C109 V? •Load short

FAN operation checking 1) Is the FAN motor running? •Controller trouble inside of
Press the ON/OFF button. 2) Is the connection of CN73 normal? the fan motor
5 1. FAN Speed[HIGH] •Connector trouble of CN73
2. FAN mode

Samsung Electronics 4-34

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 34 search engine 2011-04-08 �� 10:55:31
Troubleshooting

4-6-4 Outdoor Detailed Inspection Procedure


No Procedure Inspection Method Cause
Turn OFF the powerand Wait until C702-C707 discharged •Installation mistake
check wire and socket 1) Is connection of housing to socket normal? •Miss assembling
connection on each part 2) Is connection of each wire to terminal
1 block normal?
3) Is the reactor wire connection normal?
4) Is there no miss-wiring of each cable?

FUSE check Is the fuses on each PCB normal? •Wire short


3 fuese on EMI PCB •Overload
2 1 fuse on MAIN PCB •BLDC FAN short error
1 fuse on INVERTER PCB

Turn on the powerand Is N-R,N-S,N-T around 230Vac? •Miss wiring of power cable
check voltage of Is R-S,S-T,T-R around 400Vac? •Wire detaching
3 terminal block Is L-N(to indoor unit) around 230Vac?
Is F1-F2 within 5Vdc?
Check LED display on 1) Is RED LED ON? •MAIN PCB power trouble
AIN P 2) Is GREEN LED Blinking once a second? •Bad communication between
4 3) Is LEDs displaying error code pattern? indoor and outdoor unit
•Error detection

Check LED display on 1) Is RED LED ON? •INVERTER PCB power trouble
INVERTER PCB 2) Is GREEN LED Blinking once a second? •NO communication between
5
3) Is LEDs displaying error code pattern? MAIN and INVERTER PCB
•Error detection
Check DC voltage of MAIN PCB •SMPS circuit trouble
SMPS output 1) Is voltage of CN51 pin#1-#2 12-14.5V?
2) Is voltage of C108 5V?

6 INVERTER PCB
3) Is voltage of CN51 pin#1-#2 5V?
4) Is voltage of C124 12V?
5) Is voltage of each ZD100,ZD101,ZD102,
ZD103 17-18V?

Check INVERTER PCB 1) Is resistance of R100 200ohm? •Resister


To check this, touch one probe to •Wire connection between
CN10 pin#1(N) and the other to D101 EMI PCB and INVERTER PCB
7 upper side pin of '~' marking pins
2) Is DC Link voltage 450-510V?
Check IGBT module pins marking voltage
near C70
Check BLDC fan 1) See 12-2-3 The Outdoor unit Fan error
8 (Fault Diagnosis)

4-35 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 35 search engine 2011-04-08 �� 10:55:31
4-7 Main Part Inspection Method

Part Breakdown Inspection Method


Indoor Unit Temperature Sensor Measure sensor resistance with a multimeter

Normal At the normal temperature 37kΩ~8.3kΩ(-7˚C~+30˚C)

Abnormal ∞,0Ω...Open or Short


Indoor Unit BLDC FAN Motor Measure terminal resistance with a multimeter

At the normal temperature(10˚C~30˚C)


Wire Pin number Resistance Remark
RED - BLACK 1-3 Over 1MΩ +300V motor power
Normal WHITE - BLACK 4-3 1KΩ ~ 2KΩ +15V control power
YELLOW - BLACK 5-3 200KΩ ~ 300KΩ control
BLUE - BLACK 6-3 10KΩ ~ 50KΩ pulse

Abnormal ∞,0Ω...Open or Short


Outdoor Unit
Measure terminal resistance with a multimeter
Outdoor Temperature Sensor
& At the normal temperature 37kΩ~8.3kΩ(-7˚C~+30˚C)
Normal
Cond Temperature Senso see 12-2-6 and 12-2-8

Abnormal ∞,0Ω...Open or Short

Outdoor Unit Discharge


Measure terminal resistance with a multimeter
Temperature Sensorr
At the normal temperature 563kΩ~157kΩ(0˚C~+30˚C)
Normal
see 12-2-7

Abnormal ∞,0Ω...Open or Short

Outdoor Unit BLDC FAN MOTOR


Measure terminal resistance with a multimeter

At the normal temperature(10˚C~30˚C)


Wire Pin number Resistance Remark
RED - BLACK 1-3 Over 1MΩ +300V motor power
Normal WHITE - BLACK 4-3 1KΩ ~ 2KΩ +15V control power
YELLOW - BLACK 5-3 200KΩ ~ 300KΩ control
BLUE - BLACK 6-3 10KΩ ~ 50KΩ pulse
ORANGE - BLACK 7-3 10KΩ ~ 50KΩ reverse

Abnormal ∞,0Ω...Open or Short


Outdoor Unit 4way Valve Solenoid
Measure sensor resistance with a multimeter

Normal At the normal temperature(10˚C~30˚C) 1.6KΩ±15%

Abnormal ∞,0Ω...Open or Short

Samsung Electronics 4-36

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_1.indd 36 search engine 2011-04-08 �� 10:55:31
5. Exploded Views and Parts List

5-1 Indoor Unit

■ NS090SDXEA

13
9

6 10

14

18
20
23 5
26
21
24 3
23

8
19 22
11
15
4
12
1

15-3
15-2 16
15-6
17

15-5
15-1 15-4
7 15-7 15-8

5-1 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 1 search engine 2011-04-08 �� 11:02:08
Exploded Views and Parts List

▒ Parts List

No. Code No. Description Specification Q'TY SA/SNA

1 DB90-02402A ASS'Y CABINET FRONT ASS'Y 1 SA


2 DB90-02403A ASS'Y CABINET-TOP ASS'Y 1 SA
3 DB90-02404A ASS'Y COVER-PIPE ASS'Y 1 SA
4 DB90-02405A ASS'Y CABINET-BOTTOM BLOWER ASS'Y 1 SA
5 DB90-02406A ASS'Y CABINET-SIDE RH ASS'Y 1 SA
6 DB90-02407A ASS'Y CABINET-SIDE LF ASS'Y 1 SA
7 DB90-02408A ASS'Y-BRACKET OUTLET PART ASS'Y 1 SNA
8 DB90-02409A ASS'Y CABINET-BOTTOM DRAIN ASS'Y 1 SA
9 DB61-01282A HOLDER-SIDE CABI SGCC-M,T3.0,45.2,65 4 SNA
10 DB61-02374A BRACKET-FILTER SGCC-M,T1.0,50,250 4 SA
11 DB61-02378A HOLDER-PIPE SGCC-M,T1.0 1 SNA
12 DB63-01297A COVER-HOLDER SGCC-M,T0.8 1 SNA
13 DB63-01299B FILTER-PRE ASS'Y 1 SA
14 DB96-06727B ASS'Y EVAP-UNIT ASS'Y 1 SNA
15 DB93-05008A ASS'Y CONTROL IN ASS'Y 1 SNA
15-1 DB90-01992A ASS'Y CASE-CONTROL ASS'Y 1 SA
15-2 DB00-00000A CASE PCB ABS V0,T2.5 1 SA
15-3 DB26-00080A TRANS POWER AC 230V, 50HZ,DC 17V,DC 0.6A,VDE,ICE 1 SNA
15-4 3502-001035 SSR DC 12V,-,10A,1ms 1 SNA
15-5 2301-001381 C-FILM,LEAD-OTHER 8000nF,+10-5%,450V,BK,58x30x44mm 1 SA
15-6 DB65-00105L TERMINAL BLOCK DAF-S6P 1 SA
15-7 DB65-00105M TERMINAL BLOCK DAF-S6P 1 SA
15-8 DB61-00250A HOLDER-WIRE CLAMP ABS,BLK,ISI,SAMLINE 2 SNA
16 DB93-03213H ASS'Y PCB MAIN-IN ASS'Y 1 SNA
17 DB63-01296A COVER-CONTROL SGCC-M,T0.8 1 SA
18 DB91-00346A ASS'Y DRAIN PAN ASS'Y 1 SA
19 DB61-02331A BRACKET MOTOR SGCC-M,T2.0 1 SA
20 DB31-00355B MOTOR FAN YSK140-200-4,DC42GTVA,0.71/1.4A,50HZ 1 SNA
21 DB61-02332A CASE BLOWER-UPPER ABS,T2.0 2 SA
22 DB61-02333A CASE BLOWER-BOTTOM ABS,T2.0 2 SA
23 DB67-00583B BLOWER-D ABS 2 SA
24 DB97-03751A ASS'Y-BAND MOTOR ASS'Y 1 SNA
25 DB32-00142B THERMISTOR-IN 10Kohm,103AT,-20~+100 1 SA
26 DB95-01987B ASS'Y THERMISTORIN ASS’Y 1 SA

Samsung Electronics 5-2

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 2 search engine 2011-04-08 �� 11:02:09
Exploded Views and Parts List

■ NS140SDXEA/NS100SDXEA/S125SDXEA

15

11

16 9
6
10

17-9 4
17-6
17-10
14 22
17-8

21 8
13

17-1
7
12
17-3 17-4 18

17-5

17-2
2

17-7
3

17
18-3
18-2 20
18-6
19

18-5
18-1
18-4

18-7 18-8

5-3 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 3 search engine 2011-04-08 �� 11:02:09
Exploded Views and Parts List

▒ Parts List

No. Code No. Description Specification Q'TY SA/SNA

1 DB90-02006A ASS'Y CABINET TOP ASS'Y,SGCC-M T1.0 - SA


2 DB90-02007A ASS'Y CABI BOTTOM DRAIN ASS'Y,SGCC-M T1.0 1 SA
3 DB90-02008A ASS'Y CABI BOTTOM BLOWER ASS'Y,SGCC-M T1.0 1 SA
4 DB90-02009A ASS'Y CABI SIDE RH ASS'Y,SGCC-M T1.0 1 SA
5 DB61-01282A HOLDER SIDE CABI ASS'Y,SGCC-M T3.0 4 SNA
6 DB90-02010A ASS'Y CABI SIDE LF ASS'Y,SGCC-M T1.0 1 SA
7 DB90-02011A ASS'Y COVER PIPE ASS'Y,SGCC-M T1.0 1 SA
8 DB91-00317A ASS'Y DRAIN PAN ASS'Y,ABS/GF10 T3.0 1 SA
9 DB61-02374A BRACKET FILTER ASS'Y,SGCC-M T1.0 4 SNA
10 DB61-02380A BRACKET EVAP RH ASS'Y,SGCC-M T1.5 1 SA
11 DB61-02379A BRACKET EVAP LF ASS'Y,SGCC-M T1.5 1 SA
12 DB63-01297A COVER HOLDER ASS'Y,SGCC-M T1.0 1 SNA
13 DB61-02378A HOLDER PIPE ASS'Y,SGCC-M T1.0 1 SNA
14 DB73-00270A RUBBER COVER WIRE NBR 2 SNA
15 DB63-01299A FILTER PRE ASS'Y 1 SA
16 DB96-06728C ASS'Y EVAP UNIT 3R16C WAVE 1.5,OD7.0 1 SA
17 DB94-00742A ASS'Y BLOWER ASS'Y 1 SA
17-1 DB90-02028A ASS'Y CABI FRONT ASS'Y,SGCC-M T1.5 1 SNA
17-2 DB90-02013A ASS'Y BRACKET OUTLET PART ASS'Y,SGCC-M T1.0 1 SA
17-3 DB61-02372A BASE MOTOR ASS’Y,SGCC-M T2.5 1 SNA
17-4 DB61-02375A BRACKET MOTOR ASS'Y,SGCC-M T2.5 1 SNA
17-5 DB72-00710A BAND MOTOR ASS'Y,SGCC-M T1.6 4 SA
17-6 DB61-00540B BRACKET MOTOR GUIDE ASS'Y,SGCC-M T1.6 1 SNA
17-7 DB61-02382A CASE FAN LOW ASS'Y,ABS/GF10 T3.0 2 SA
17-8 DB61-02381A CASE FAN UP ASS'Y,ABS/GF10 T3.0 2 SA
17-9 DB67-00594A BLOWER ASS'Y,ABS/GF10 OD230 2 SA
17-10 DB31-00321B MOTOR FAN OSM4524SAC (S334) 1 SA
18 DB93-05008A ASS'Y CONTROL IN ASS'Y 1 SA
18-1 DB90-01992A ASS'Y CASE CONTROL ASS'Y,SGCC-M T1.0 1 SNA
18-2 DB61-02287A CASE PCB ABS V0 1 SA
18-3 DB26-00080A TRANS POWER DC17V 1 SNA
18-4 3502-001035 SSR OMRON G3NA-210BPL 1 SNA
18-5 2301-001381 C-FILM,LEAD-OTHER 8uF 450VAC 1 SA
18-6 DB65-00105M TERMINAL BLOCK 6P 250V,20A 1 SNA
18-7 DB65-00105L TERMINAL BLOCK 6P 250V,20A 1 SNA
18-8 DB61-00250A HOLDER-WIRE CLAMP NYLON 2 SNA
19 DB63-01296A COVER CONTROL ASS'Y,SGCC-M T0.8 1 SA
20 DB00-00000A ASS'Y PCB MAIN DH140EAV 1 SA
21 DB32-00142B THERMISTOR-ASS'Y 103AT,103FW 1 SA
22 DB95-01987B ASS'Y THERMISTOR IN ASS'Y 1 SA

Samsung Electronics 5-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 4 search engine 2011-04-08 �� 11:02:09
Exploded Views and Parts List

■ NS090SSXEA/NS090SSXEX/NS100SSXEA/NS100SSXEX

12

6
9
5
13

7
10
14-7 11
14-4
14-8 15
8
14-6
10

2
2

14-3
14-1

15-3
15-2
14-2 16 11
15-6
14-5
3
15-5
15-4
15-1 15-7
15-8
17

14

5-5 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 5 search engine 2011-04-08 �� 11:02:11
Exploded Views and Parts List

▒ Parts List
Q'TY
No. Code No. Description Specification NS090SSXEA SA/SNA
NS090SSXEX NS100SSXEX
NS100SSXEA

1 DB90-02927B ASS'Y CABINET-TOP MA0 PJT,SSEC 1 1 1 SNA


2 DB90-02405C ASS'Y CABINET-BOTTOM BLOWERMA1,SSEC 1 1 1 SA
3 DB90-02409D ASS'Y CABINET-BOTTOM DRAIN MA1,SSEC 1 1 1 SA
4 DB90-02929A ASS'Y CABINET-SIDE RH MA0 PJT,SSEC 1 1 1 SA
5 DB61-01282A HOLDER-SIDE CABI ADC6000TG,SGCC-M,T3.0 4 4 4 SA
6 DB90-02930A ASS'Y CABINET-SIDE LF MA0 PJT,SSEC 1 1 1 SA
7 DB90-02928B ASS'Y COVER-PIPE MA0 PJT,SSEC 1 1 1 SA
8 DB94-02001B ASS'Y DRAIN PANDH42BTA,SSEC 1 - - SA
DB94-02001A ASS'Y DRAIN PANDH42BTA,SSEC - 1 1 SA
9 DB61-02643A BRACKET-FILTER SGCC-M,T0.8 4 4 4 SA
10 DB95-01710A ASS'Y THERMISTOR IN ASS'Y 1 1 1 SA
11 DB63-01657B COVER-CONTROLMAO DUCT,SGCC-M,T0.8 1 1 1 SA
12 DB63-01299D FILTER-PR EASS'Y,T4.5,178,985,NATURE 1 1 1 SA
13 DB96-07024C ASS'Y EVAP-UNIT DH094EAMC,220-240V, 50HZ, 9.4KW 1 - - SA
DB96-07024G ASS'Y EVAP-UNIT DH094EAMC,220-240V, 50HZ, 9.4KW - 1 - SA
DB96-07024A ASS'Y EVAP-UNIT DH094EAMC,220-240V, 50HZ, 9.4KW - - 1 SA
14 DB94-01274A ASS'Y FAN IN PART SH094EAMC, 220-240V, 50HZ, 9.4KW 1 1 1 SNA
14-1 DB90-02926A ASS'Y CABI FRONT MA0 PJT,SSEC 1 1 1 SA
14-2 DB90-03030B ASS'Y-BRACKET OUTLET PART DH90EAMC,SSEC,GLOBAL PJT 1 1 1 SA
14-3 DB61-03058A BRACKET MOTOR SGCC-M,T2.5 1 1 1 SA
14-4 DB97-03751B ASS'Y-BAND MOTORSLIM DUCT 3,SSEC 1 1 1 SA
14-5 DB61-03059A CASE BLOWER-UP ABS+10%GF 2 2 2 SA
14-6 DB61-03060A CASE BLOWER-LOW ABS+10%GF 2 2 2 SA
14-7 DB67-00583B BLOWER-D EH140EZMC,ABS 2 2 2 SA
14-8 DB31-00355B MOTOR FAN YSK140-200-4 1 1 1 SA
15 DB93-12487A ASS'Y CONTROL IN ASS'Y 1 1 1 SA
16 DB93-12406A ASS'Y MAIN PCB ASS'Y 1 1 1 SA
17 DB95-01983B ASS'Y THERMISTOR IN ASS'Y 1 1 1 SA

Samsung Electronics 5-6

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 6 search engine 2011-04-08 �� 11:02:11
5-2 Outdoor Unit

■ RC090DHXEA/RC090SHXEA/RC100SHXEA/RC100DHXEA/RC100DHXGA

16

8
21 9

1
22
11

13
5
15

14
18 23

23-1

23-2 23-3

10
12
7 19

3
20
7-1
4
6
17

5-7 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 7 search engine 2011-04-08 �� 11:03:07
Exploded Views and Parts List

■ Parts List
Q'TY
RC100SHXEA
No. Code No. Description Specification RC090DHXEA SA/SNA
RC100DHXGA
RC090SHXEA
RC100DHXEA
1 DB63-02730A GUARD-COND MSWR-6B, TOUCH GRAY 1 1 SA
2 DB64-02525A CABI INSTALL BACK EGI, T0.7 1 1 SA
3 DB64-02526A CABI INSTALL FRONT EGI, T0.7 1 1 SA
4 DB90-05873A ASS'Y BASE OUT ASS'Y 1 1 SA
5 DB90-05903A ASS'Y CABI BACK RH ASS'Y 1 1 SA
6 DB90-05904A ASS'Y CABI FRONT RH ASS'Y 1 1 SA
7 DB90-05971A ASS'Y CABI FRONT LF ASS'Y 1 1 SA
7-1 DB63-02743A GUARD FAN PP, MT72TG 1 1 SA
8 DB90-05902A ASS'Y CABINET TOP ASS'Y 1 1 SA
9 DB94-02720A ASS'Y PARTITION ASS'Y 1 1 SA
10 DB93-08235E ASS'Y CONNECTOR WIRE COMP ASS'Y, 1Ø 1 - SNA
DB93-08235D ASS'Y CONNECTOR WIRE COMP ASS'Y, 3Ø - 1 SNA
11 DB93-11292A ASS'Y CONTROL OUT ASS'Y, 1Ø 1 - SNA
DB93-11349A ASS'Y CONTROL OUT ASS'Y, 3Ø - 1 SNA
12 DB95-04522A ASS'Y THERMISTOR OUT ASS'Y 1 1 SA
13 DB31-00579A MOTOR FAN DAO335130ZRC, CLASS E 1 1 SA
14 DB60-00405A FASTENER WASHER M8 1 1 SNA
15 DB67-01061A FAN PROPELLER PP+MICA+GF, 520PI 1 1 SA
16 DB90-05918A ASS'Y BRACKET MOTOR ASS'Y 1 1 SA
17 DB60-30028A SCREW HEX HWH,WP,M8,ZPC(WHT),SWRCH18A 3 3 SNA
18 DB63-02953A CLOTH COMP TOP FELT, BLACK,1Ø 1 - SNA
DB63-02987A CLOTH COMP TOP FELT, BLACK,3Ø - 1 SNA
19 DB63-02954A CLOTH COMP SIDE FELT, BLACK,1Ø 1 - SNA
DB63-02954B CLOTH COMP SIDE FELT, BLACK,3Ø - 1 SNA
20 UG8T300FUBJUSG COMPRESSOR ASS'Y, 1Ø 1 - -
UG5T450FUFJXSG COMPRESSOR ASS'Y, 3Ø - 1 -
21 DB90-02316E ASS'Y HOLDER PLATE COND ASS'Y 2 2 SA
22 DB96-15469A ASS'Y COND OUT ASS'Y 1 1 SA
23 DB96-15476A ASS'Y VALVE ASS'Y, 1Ø 1 - SA
DB96-15476B ASS'Y VALVE ASS'Y, 3Ø - 1 SA
23-1 DB90-05874B ASS'Y BRACKET VALVE ASS'Y 1 1 SA
23-2 DB96-14880A ASS'Y VALVE 4WAY RC100DHXEA, R410A, 1Ø 1 - SA
DB96-14886A ASS'Y VALVE 4WAY RC100DHXGA, R410A, 3Ø - 1 SA
23-3 DB96-14885A ASS'Y TUBE EEV RC100DHXEA, R410A 1 1 SA

Samsung Electronics 5-8

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 8 search engine 2011-04-08 �� 11:03:08
Exploded Views and Parts List

■ RC125DHXEB/RC125DHXGA/RC140DHXEB/RC140DHXGA

1
22
21
9 11

16
5

13

15

14
7

18
23
19 23-1
7-1 23-2
20
17 23-3

4 10

12

2
6

5-9 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 9 search engine 2011-04-08 �� 11:04:29
Exploded Views and Parts List

■ Parts List
Q'TY

No. Code No. Description Specification RC125DHXEB RC125DHXGA SA/SNA


RC140DHXEB RC140DHXGA

1 DB63-02706A GUARD COND MSWR-6B, TOUCH GRAY 1 1 SA


2 DB64-02525A CABINET-INSTALL BACK EGI, T0.7 1 1 SA
3 DB64-02526A CABINET-INSTALL FRONT EGI, T0.7 1 1 SA
4 DB90-05873A ASS'Y BASE OUT ASS'Y 1 1 SA
5 DB90-05876A ASS'Y CABI BACK-RH ASS'Y 1 1 SA
6 DB90-05877A ASS'Y CABI FRONT RH ASS'Y 1 1 SA
7 DB90-05878A ASS'Y CABI FRONT-LF ASS'Y 1 1 SA
7-1 DB63-02696A GUARD FAN PP, MT72TG 2 2 SA
8 DB90-05902A ASS'Y CABINET-TOP ASS'Y 1 1 SA
9 DB94-02697A ASS'Y PARTITION ASS'Y 1 1 SA
10 DB93-08235G ASS'Y CONNECTOR WIRE-COMP ASS'Y, 1Ø 1 - SNA
DB93-08235F ASS'Y CONNECTOR WIRE-COMP ASS'Y, 3Ø - 1 SNA
11 DB93-11292A ASS'Y CONTROL OUT ASS'Y, 1Ø 1 - SNA
DB93-11349A ASS'Y CONTROL OUT ASS'Y, 3Ø - 1 SNA
12 DB95-04522B ASS'Y THERMISTOR OUT-MANU ASS'Y 1 1 SA
13 DB31-00579A MOTOR FAN DAO335130ZRC, CLASS E 2 2 SA
14 DB60-00405A FASTENER-WASHER M8 2 2 SNA
15 DB67-01057A FAN-PROPELLER PP+MICA+GF, 480PI 2 2 SA
16 DB90-05875A ASS'Y BRACKET MOTOR ASS'Y 1 1 SA
17 DB60-30028A SCREW-HEX HWH,WP,M8,ZPC(WHT),SWRCH18A 3 3 SNA
18 DB63-02832A CLOTH-COMP TOP FELT, BLACK 1 1 SNA
19 DB63-02834A CLOTH-COMP SOUND FELT, BLACK 1 1 SNA
20 UG5T450FUEJXSG COMPRESSOR ASS'Y, 1Ø 1 - -
UG5T450FUFJXSG COMPRESSOR ASS'Y, 3Ø - 1 -
21 DB90-02316E ASS'Y HOLDER-PLATE COND ASS'Y 2 2 SA
22 DB96-14661A ASS'Y COND OUT ASS'Y 1 1 SA
23 DB96-14898A ASS'Y-VALVE ASS'Y 1 1 SA
23-1 DB90-05874A ASS'Y BRACKET-VALVE RC100PHXEA,ManU 1 1 SA
23-2 DB96-14488A ASS'Y-VALVE 4WAY RC100PHXEA,R410A 1 1 SA
23-3 DB96-14510A ASS'Y TUBE-EEV RC100PHXEA,R410A 1 1 SA

Samsung Electronics 5-10

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 10 search engine 2011-04-08 �� 11:04:30
5-3 ASS'Y CONTROL OUT

■ RC125DHXEB/RC125DHXGA/RC140DHXEB/RC140DHXGA

11

1
12
7

12-3 8
12-4
8-1

4 8-2

8-3
5
8-4

12-1
3 8-5

12-2

10
2
13
6

5-11 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 11 search engine 2011-04-08 �� 11:04:32
Exploded Views and Parts List

■ Parts List
Q'TY

No. Code No. Description Specification RC125DHXEB RC125DHXGA SA/SNA


RC140DHXEB RC140DHXGA

1 DB59-00016A AC REACTOR-1PHASE 30A 30A, 1Ø 1 - SA


DB59-00015A AC REACTOR-3PHASE 20A 20A, 3Ø - 1 SA
2 DB61-04504A CASE-INV ABS, BLACK, 1Ø 1 - SNA
DB61-04657A CASE-INV ABS, BLACK, 3Ø - 1 SNA
3 DB62-09441A HEAT SINK AL, 1Ø 1 - SA
DB62-09441C HEAT SINK AL, 3Ø - 1 SA
4 0205-000178 GREASE-SILICON YG1111,TOSHIBA(NTR) 7g 7g SNA
5 6001-001054 SCREW-MACHINE TH,M4,L10 4 4 SNA
6 6002-000635 SCREW-TAPPING PH,M4,L8 2 2 SNA
7 6002-001149 SCREW-TAPPING TH,M4,L12 8 8 SNA
8 DB90-06115A ASS'Y CASE-PCB ASS'Y, 1Ø 1 - SA
DB90-06115B ASS'Y CASE-PCB ASS'Y, 3Ø - 1 SA
8-1 DB61-04502A CASE-EMI ABS, BLACK 1 1 SNA
8-2 DB61-04503A CASE-MAIN ABS, BLACK 1 1 SNA
8-3 DB93-10809A ASS'Y CONNECTOR WIRE ASS'Y 1 1 SA
8-4 DB93-11109A ASS'Y PCB MAIN-OUT Inverter Platform #4, #5, #6 MAIN 1 1 SA
8-5 DB93-11110A ASS'Y PCB SUB-EMI Inverter Platform #4, #5 EMI, 1Ø 1 - SA
DB93-11111A ASS'Y PCB SUB-EMI Inverter Platform #6 EMI, 3Ø - 1 SA
9 DB91-00306A ASS'Y-SCREW MACHINE M3, L16 2 2 SA
10 DB91-00307A ASS'Y-SCREW MACHINE M4, L16 2 2 SA
11 DB93-10807A ASS'Y CONNECTOR WIRE ASS'Y, MAIN TO INVERTER 1 1 SA
12 DB93-10966A ASS'Y CONTROL OUT-PLATE ASS'Y, 1Ø 1 - SA
DB93-10966B ASS'Y CONTROL OUT-PLATE ASS'Y, 3Ø - 1 SA
12-1 DB65-00296A TERMINAL BLOCK-POWER 4P, 1Ø 1 - SNA
DB65-00185C TERMINAL BLOCK-POWER 6P, 3Ø - 1 SNA
12-2 DB65-00297A TERMINAL BLOCK-COMM 2P 1 1 SA
12-3 DB90-05889A ASS'Y CASE CONTROL OUT ASS'Y 1 1 SA
12-4 DB93-10808A ASS'Y CONNECTOR WIRE ASS'Y, TERMIANL TO MAIN 1 1 SA
13 DB93-11112A ASS'Y PCB MAIN-INVERTER Inverter Platform #4, 1Ø 1 - SA
DB93-11114A ASS'Y PCB MAIN-INVERTER Inverter Platform #6, 3Ø - 1 SA
14 DB93-10864A ASS'Y CONNECTOR WIRE RST AWG #14 - 1 SA
15 DB93-11241A ASS'Y CONNECTOR WIRE REATOR AWG #12 - 1 SA

Samsung Electronics 5-12

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 12 search engine 2011-04-08 �� 11:04:32
6. PCB Diagram

6-1 PCB Diagram

6-1-1 Indoor Unit

1 2 3 4 9 5 6 7 8 10

19 18 15 20 17 16 21 14 22 23 24 25 11 12 13

1 Floating S/W : SMW250-02(BLK) 13 Wired Remote Controller Communication : YW396-02(BLU)


Indoor Pipe In Temperature Sensor : SMW250-04(WHT) 14 Option Load Connector : SMW250-05(YEL)
2
Indoor Room Temperature Sensor : SMW250-04(WHT) 15 Heater : YW39607AV(WHT)
Indoor Pipe Out : SMW250-02(WHT) 16 Indoor Address S/W
3
Temperature Sensor : SMW250-02(WHT) 17 Indoor Option S/W
Heater Discharge : SMW250-02(YEL) 18 Indoor Fan(TAP) : YW396-09AV(WHT)
4
Temperature Sensor : SMW250-02(YEL) 19 Ventilator : YW396-03AV(BLK)
6-1
5 Wired Remote Controller Power : YW396-02(WHT) 20 Drain Pump : YW396-03AV(YEL) Samsung Electronics
6 External Control(S/W Part) : SMW250-02(RED) 21 Hot Coil : YW396-03AV(RED)
7 EEV : SMW250-05(BLU) : SMW250-05(BLU) 22 Indoor Fan(SSR) : YW396-03AV(RED)
8 Display : SMW200-11(WHT) : SMW200-11(WHT) Power : YW396-03AV(WHT)
23
Downloaded from www.Manualslib.com
9 Externalmanuals
NS090SDXEA_E_SM_33623A(1)_2.indd 1 search engine
Control(Display Part) : SMW250-04(RED) Transformer Out : YW396-03AV(WHT) 2011-04-08 �� 11:04:33
PCB Diagram

1 Floating S/W : SMW250-02(BLK) 13 Wired Remote Controller Communication : YW396-02(BLU)


Indoor Pipe In Temperature Sensor : SMW250-04(WHT) 14 Option Load Connector : SMW250-05(YEL)
2
Indoor Room Temperature Sensor : SMW250-04(WHT) 15 Heater : YW39607AV(WHT)
Indoor Pipe Out : SMW250-02(WHT) 16 Indoor Address S/W
3
Temperature Sensor : SMW250-02(WHT) 17 Indoor Option S/W
Heater Discharge : SMW250-02(YEL) 18 Indoor Fan(TAP) : YW396-09AV(WHT)
4
Temperature Sensor : SMW250-02(YEL) 19 Ventilator : YW396-03AV(BLK)
5 Wired Remote Controller Power : YW396-02(WHT) 20 Drain Pump : YW396-03AV(YEL)
6 External Control(S/W Part) : SMW250-02(RED) 21 Hot Coil : YW396-03AV(RED)
7 EEV : SMW250-05(BLU) : SMW250-05(BLU) 22 Indoor Fan(SSR) : YW396-03AV(RED)
8 Display : SMW200-11(WHT) : SMW200-11(WHT) Power : YW396-03AV(WHT)
23
9 External Control(Display Part) : SMW250-04(RED) Transformer Out : YW396-03AV(WHT)
10 HALL IC : SMW250-03(BLU) 24 Main Power In : YW396-03AV(BLU)
11 MICOM Download : SMW200-10(WHT) Power : YW396-03AV(BLU)
25
12 Indoor/Outdoor Communication : YW396-02(RED) Transformer In : SMW250-03(RED)

Samsung Electronics

Samsung Electronics 6-2

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 2 search engine 2011-04-08 �� 11:04:33
PCB Diagram

6-1-2 Outdoor Unit PCB

■ Main PCB

1 5 2 6 3 16 4 7 9 11 13
15 8 10 12 14

6-3 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 3 search engine 2011-04-08 �� 11:04:44
PCB Diagram

① CN11-AC POWER ② CN74-AC LOAD1 ③ CN75-4WAY V/V ④ CN71-AC LOAD2(Option)


#1-#3 : 220~240Vac #1-#3 : 220~240Vac #1-#3 : 220~240Vac #1-#3 : 220~240Vac

⑤ CN37-Micom Download ⑥ CN35-AS-PRO ⑦ CN43-Sensor ⑧ CN81-EEV 1


#1 : RXD_INV #1 : DC 5V #1-#2 : Outdoor Temp. #1~#4 : Motor signal
#2 : TXD_INV #2 : MODE #3-#4 : Cond. Temp. #5 : DC 12V
#3, #8 : N.C #3 : Reset #5-#6 : Discharge Temp.
#4 ~ #7 : Data signal #4~#6 : GRID_3/1/2 #7-#8 : OLP Temp.
#9 : GND #7 : GND
#10 : DC 5V

⑨ CN82-EEV 2(Option) ⑩ CN83-EEV 3(Option) ⑪ CN39-COMM-INV ⑫ CN44-TEMP OPTION(Option)


#1~#4 : Motor signal #1~#4 : Motor signal #1 : TXD #1 : Temp. signal
#5 : DC 12V #5 : DC 12V #2 : RXD #2 : GND
#3 : GND
#4 : DC 5V
#5 : DC 12V
#6 : INV. SMPS signal

⑬ CN42-High Pressure(Option) ⑭ CN12-DC12V ⑮ CN31-Comm. ⑯ CN33-Sub Comm.


#1 : High Pressure temp. signal #1 : DC 12V #1 : COM1 #1 : DC 12V
#3 : GND #2 : GND #2 : COM2 #2 : GND
#4 : DC 5V #3 : DC 5V
#4 : COM1
#5 : COM2

Samsung Electronics 6-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 4 search engine 2011-04-08 �� 11:04:45
PCB Diagram

Outdoor Unit PCB (cont.)

■ Inverter PCB : 1Phase I


- RC090DHXEA/RC100SHXEA/RC100DHXEA/RC125DHXEB/RC140DHXEB

2 1 3 4 5 8
6 7

① Reactor-A1/B1 ② Reactor-A2/B2 ③ CN50(2PIN/RED)-Communication ④ CN22-Downloader


#Reactor-A2 : WHT #Reactor-A2 : BLK #1 : RXD, #2 : TXD #1 : RXD_ATARO, #2 : TXD_ATARO
#Reactor-B2 : WHT #Reactor-B2 : BLK #3 : GND, #4 : DC 5V #3, #8 : N.C, #4~#7 : DATA signal
#5 : DC 12V, #6 : INV. SMPS signal #9 : GND, #10 : DC 5V

⑤ CN21-DAC/ENCODER ⑥ CN91-FAN2 ⑦ CN90-FAN1 ⑧ CN71-COMP.


For S/W engineer debugging #1 : DC 360V #1 : DC 360V #1 : COMP. U-phase(RED)
#2 : N.C #2 : N.C #2 : COMP. V-phase(BLU)
#3 : GND #3 : GND #3 : COMP. U-phase(YEL)
#4 : DC 15V #4 : DC 15V
#5 : FAN RPM #5 : FAN RPM
#6 : FAN RPM feedback #6 : FAN RPM feedback

6-5 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 5 search engine 2011-04-08 �� 11:04:46
PCB Diagram

Outdoor Unit PCB (cont.)

■ Inverter PCB : 3Phase


- RC100DHXGA/RC125DHXGA/RC140DHXGA

1 2 6 7 3 4 5
9 8

① RST-AC POWER 3phase ② CN100-AC POWER ③ CN31-MAIN COMM ④ CN22-Downloader


#R : AC 380~400V : WHT #1-#3 : AC 220~240V #1 : RXD , #2 : TXD #1 : RXD_ATARO, #2 : TXD_ATARO
#S : AC 380~400V : BRN #3 : GND, #4 : DC 5V #3, #8 : N.C, #4~#7 : DATA signal
#T : AC 380~400V : BLK #5 : DC 12V, #6 : INV. SMPS signal #9 : GND, #10 : DC 5V

⑤ CN21-DAC/ENCODER ⑥ CN91-FAN2 ⑦ CN90-FAN1 ⑧ CN800-COMP.


For S/W engineer debugging #1 : DC 360V , #2 : N.C #1 : DC 360V, #2 : N.C #1 : COMP. U-phase(RED)
#3 : GND, #4 : DC 15V #3 : GND, #4 : DC 15V #2 : COMP. V-phase(BLU)
#5 : FAN RPM, #6 : FAN RPM feedback #5 : FAN RPM, #6 : FAN RPM feedback #3 : COMP. U-phase(YEL)

⑨ CN600-REACTOR
#1-#2 : DCL Reactor

Samsung Electronics 6-6

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 6 search engine 2011-04-08 �� 11:04:59
PCB Diagram

Outdoor Unit PCB (cont.)

■ EMI PCB : 1Phase


- RC***XE*

2 3 1

① L1-AC POWER L phase ② N1-AC POWER N phase ③ CN01-AC POWER


L1 : BRN N1 : SKY-BLU #1-#3 : AC 220~240V

6-7 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 7 search engine 2011-04-08 �� 11:05:08
PCB Diagram

Outdoor Unit PCB (cont.)

■ EMI PCB : 3Phase


- RC***XGA

1 2

① RST-AC POWER 3phase ② CN100-AC POWER


#R : AC 380~400V : WHT #1-#3 : AC 220~240V
#S : AC 380~400V : BRN
#T : AC 380~400V : BLK

Samsung Electronics 6-8

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 8 search engine 2011-04-08 �� 11:05:17
7. Wiring Diagram

7-1 Indoor Unit

This Document can not be used without Samsung’s authorization.

7-1 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 1 search engine 2011-04-08 �� 11:05:18
Wiring Diagram

7-2 Outdoor Unit

 Outdoor Unit : RC***XE*

This Document can not be used without Samsung’s authorization.

Samsung Electronics 7-2

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 2 search engine 2011-04-08 �� 11:05:20
Outdoor Unit (cont.)

 Outdoor Unit : RC***XGA

This Document can not be used without Samsung’s authorization.

7-3 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 3 search engine 2011-04-08 �� 11:05:23
MEMO

Samsung Electronics 7-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 4 search engine 2011-04-08 �� 11:05:23
8. Schematic Diagram

8-1 Indoor Unit

8-1-1 MAIN PCB

This Document can not be used without Samsung’s authorization.

Samsung Electronics 8-1

NS090SDXEA_E_SM_33623A(1)_2.indd 1-2 2011-04-08 �� 11:09:12

Downloaded from www.Manualslib.com manuals search engine


Schematic Diagram Schematic Diagram

8-1-2 Outdoor Unit PCB


■ MAIN PCB

This Document can not be used without Samsung’s authorization.

Samsung Electronics 8-7

NS090SDXEA_E_SM_33623A(1)_2.indd 3-4 2011-04-08 �� 11:09:34

Downloaded from www.Manualslib.com manuals search engine


Schematic Diagram Schematic Diagram

outdoor unit pcb (cont.)


■ Inverter PCB : 1Phase I
- RC***HXE*

This Document can not be used without Samsung’s authorization.

Samsung Electronics 8-8

NS090SDXEA_E_SM_33623A(1)_2.indd 5-6 2011-04-08 �� 11:09:38

Downloaded from www.Manualslib.com manuals search engine


Schematic Diagram Schematic Diagram

outdoor unit pcb (cont.)


■ EMI PCB : 1Phase
- RC***XE*

This Document can not be used without Samsung’s authorization.

Samsung Electronics 8-10

NS090SDXEA_E_SM_33623A(1)_2.indd 7-8 2011-04-08 �� 11:09:38

Downloaded from www.Manualslib.com manuals search engine


Schematic Diagram Schematic Diagram

outdoor unit pcb (cont.)


▒ EMI PCB : 3Phase

- RC***XGA

This Document can not be used without Samsung’s authorization.

Samsung Electronics 8-11

NS090SDXEA_E_SM_33623A(1)_2.indd 9-10 2011-04-08 �� 11:09:38

Downloaded from www.Manualslib.com manuals search engine


9. Reference Sheet

9-1 Index for Model Name

9-1-1 Indoor Unit

Model Code

NS
H 100
H HH HH XH EH AH /H SER
H

Buyer Name

Product Type Mode Rating Voltage


N S Single C C/O A 115V, 60Hz
H H/P B 220V, 60Hz
T Tender C 208~230V, 60Hz
Capacity (3 DIGIT) V Value D 200~220V, 50Hz
KW / BTU / Liter When grade E 220~240V, 50Hz
classification is necessary F 208~230V, 60Hz, 3Phase
Z H/P (Flagship)
G 380~415V, 50Hz, 3Phase
Chassis Category P H/P (Premium)
M 127V, 50Hz
1 1 WAY D H/P (Deluxe)
H 380V, 60Hz, 3Phase
2 2 WAY S H/P (Standard)
CST J 460V, 60Hz, 3Phase
M MINI 4 WAY CP H/P (Premium)
4 4 WAY
High Static Version
H
Pressure Refrigerant Change point
Middle Static 1~9
S R R-22 (Korean market)
Pressure
Duct X R410A Change point
Low Static A~Z
L (export/foreign market)
Pressure(Slim)
The Z version is a
E Air handler Z high-efficiency EEV Mode
G CCD (Slim) indoor unit.
C Ceiling
J Console Conv
F Floor type
P FAC & Mid/Large Size
B Mont Blanc
V Vivace
Q Neo Forte (EEV)
N Neo-Forte
RAC
Korean market
W
use
R Crystal
A Max

※ "/" can be removed from the buyer card if there are not enough digits.

9-1 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 1 search engine 2011-04-08 �� 11:06:05
Reference Sheet

Index for Model Name (cont.)

9-1-2 Outdoor Unit

Model Code

RC
H 140
H VH H HH XH GH AH /H SER
H


Buyer Name

Product Type Separator Rating Voltage


N C Single (CAC) 1 Universal A 115V, 60Hz
1 1 WAY B 220V, 60Hz
2 2 WAY C 208~230V, 60Hz
CST
Capacity (3 DIGIT) M MINI 4 WAY D 200~220V, 50Hz
HP / KW / BTU / TON 4 4 WAY E 220~240V, 50Hz
High Static F 208~230V, 60Hz, 3Phase
H
Pressure G 380~415V, 50Hz, 3Phase
Chassis Category Middle Static
S Duct M 127V, 50Hz
Pressure
P Inverter RPM H 380V, 60Hz, 3Phase
Low Static
D Inverter DLX L
Pressure(Slim) J 460V, 60Hz, 3Phase
S Inverter STD C Ceiling
F Constant rate (value) J Console Conv
X Constant rate (tender) F Floor type Version
Z Flagship P FAC & Mid/Large Size Change point
1~9
T Tower (Top Discharge) (Korean market)
Change point
U Ice box A~Z
(export/foreign market)
Mode
C C/O
H H/P
T Tropical C/O
Q TROPICAL H/P

Refrigerant
R R-22
X R410A


※ MCD: Dummy mock-up model
※ “/” can be removed from the buyer card if there are not enough digits.

Samsung Electronics 9-2

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 2 search engine 2011-04-08 �� 11:06:05
9-2 Refrigerating Cycle Diagram

Indoor Unit Outdoor Unit

Electronic expansion valve

3-way valve

Liquid pipe

Heat exchanger Heat exchanger


Evaporator Fan Evaporator Fan

4-way valve
Gas pipe

3-way valve Aux accumulator

Compressor
Oil separator
Cooling
Heating
Leak check points

▒ CONDENSER
High temperature and high pressure gas state coolant discharged from the compressor is converted to a liquid state as it is cooled
down by the heat emission in the outdoor condenser unit, and sent to the evaporator.

▒ COMPRESSOR
Low temperature and low pressure coolant is compressed and sent to the cycling system

▒ EVAPORATOR
Liquid coolant sucked in through the capillary tubes cools down the room by absorbing the surrounding heat as it evaporates
(converting from liquid to gas). (Absorbing heat required for evaporation)

▒ SERVICE VALVE
You can open the valve by turning the need valve counterclockwise using hex wrench, and it is used for vacuum, gas purging, coolant
injection, coolant purging, and indoor-outdoor unit connection.

▒ ACCUMULATOR
Accumulator prevents the flow of liquid-state coolant into the compressor. (Liquid-state coolant flowing into the compressor will
overload the compressor.)

9-3 Samsung Electronics

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 3 search engine 2011-04-08 �� 11:06:06
9-3 Pressure Graph

Cooling ▒ Cooling
10.0
Indoor (°C)
9.5
Outdoor(°C) 32/23 27/19 21/15
9.0
Pressure(kgf/cm²G)

8.5 50 10.0 9.1 8.0


8.0 35 9.0 8.3 7.2
7.5
7.0
20 6.8 6.3 6.4
6.5 7 7.6 7.1 6.5
6.0
-5 7.7 7.2 6.5
5.5
5.0
-10 0 10 20 30 40 50 60
Outdoor Temp.(°C)

Waiting Mode ▒ Waiting Mode


Indoor (°C)
Outdoor(°C) 32/23 27/19 21/15

50 18.5 16.7 15.9


Pressure(kgf/cm²G)

35 15.7 14.7 13.4


20 15.2 14.3 13.6
7 9.1 9.1 9.1
-5 5.6 5.6 5.6
-20 3.0 3.0 3.0

Outdoor Temp.(°C)

Heating ▒ Heating
Indoor (°C)
Outdoor(°C) 28/18 27/19 20/15

20 33.6 33.3 30.1


Pressure(kgf/cm²G)

7 27.9 27 23.5
-5 24.2 23.9 19.9
-20 22.5 22.2 17.9

Outdoor Temp.(°C)

Samsung Electronics 9-4

Downloaded from www.Manualslib.com manuals


NS090SDXEA_E_SM_33623A(1)_2.indd 4 search engine 2011-04-08 �� 11:06:06
GSPN(Global Service Partner Network)
Area Web Site
North America http://service.samsungportal.com
Latin America http://latin.samsungportal.com
CIS http://cis.samsungportal.com
Europe http://europe.samsungportal.com
China http://china.samsungportal.com
Asia http://asia.samsungportal.com
Mideast & Africa http://mea.samsungportal.com

This Service Manual is a property of Samsung Electronics Co., Ltd. © Samsung Electronics Co., Ltd. Apr. 2011.
Any unauthorized use of Manual can be punished under applicable Printed in Korea.
International and/or domestic law. Code No. DB98-33623A(1)

Downloaded from www.Manualslib.com manuals


NS100SSXEA_E_33623A(1)_co.indd 2 search engine 2011-04-08 �� 10:52:44

You might also like