You are on page 1of 1

THARWANI REALTY

MAJESTIC TOWER B
INDENT NO:-234 R1 Indent Date: 22.06.2023

Deseription: For the below Quantity, following Material are required

1ST TYPICAL TO 2ND TYPICAL FLOOR COLUMN CONCRETE


QUANTITY
FOR COLUMN TOTAL CONCRETE QTY - M50 M3 121.56
FOR STAIRCASETOTAL CONCRETE QTY - M40 M3 7.17

SR. N0. MATERIAL CONSUMPTION UNIT


TOTAL QTY TOTAL
M50 |QTY M40
CEMENT (0.P.C.) BAGS 1094.00 59.00
i SAND BRASS 21.44 1.34
3 METAL-1(10MM) BRASS 12.15 0.78
4 METAL-2 (20 MM) BRASS 14.37 0.92
CHEMICAL ADMIXTURE LTR. 63.09 2.69

NOTE
)HT OF FLOOR COLUMN=3.1-0.600=2.5M (upto beam bottom)
2)Staircase Ist typ flr. To 2nd typ flr. first flight and midlanding qty is consider in this indent.
3)In Rl revision- Grade of Concrete of Column and Stairecase is different.
4)Previous Indent was calculated by Sandesh in which grade of concrete for column and stairecase
consider same

PREPARED BY: CHECKED BY: