Professional Documents
Culture Documents
1 ¯
d=h−covering ( usually 20 mm )− ( main diameter )
2
1
d=150−20− (12 )
2
d=124 mm
(
Rafters and Bracing - 0.24
kN
m2 )
(1 m )=0.24 kN /m
b. Wall
(
Exterior Wall (6’’ CHB) - 3.45
kN
m2 )
( 1 m) =3.45 kN /m
Interior Wall (CHB plastered) - 1.72 ( kN
m
2 )
( 1m )=1.72 kN /m
c. Floor Finishes
d. Ceiling
( kNm ) ( 1m )=1kN /m
Ceiling loads - 1 2
e. Weight of slab -
kN
Total Dead Load=10.424
m
Live load:
(
Basic Floor Area (Residential) - 1.9
kN
m2 )
( 1 m) =1.9 kN /m
(
Basic Floor Area (Balcony) - 2.9
kN
m2 )
( 1 m )=2.9 kN /m
kN
Total Live Load=4.8
m
Compute for Wu:
Wu=1.2 ( Dl ) +1.6 ( Ll )
Wu=1.2 10.424 ( kN
m ) (
+ 1.6 4.8
kN
m )
kN
Wu=20.1888
m
D. Check ACI Table 2 coefficients for dead load positive moment and live load positive moment in
Two-way slab if m=0.75 , case no . 4
Positive Moment:
C ¿ =0.052
+m
+ Mu Dl=0.043(Wu Dl )¿ + Mu ¿=0.052(Wu¿ ) ¿
+ Mu Dl =0.043(10.424 kN /m)¿ + Mu ¿=0.052(4.8 kN /m) ¿
kN kN
+ Mu Dl =4.034 (1.2) + Mu ¿=2.2464 (1.6)
m m
kN kN
+ Mu Dl=4.841 + Mu ¿=3.59424
m m
+ Mu=8.435 kN /m
To be safe in flexure:
1.4
ρ min =
fy
ρ min =0.00507
371.628
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
s= =304.321 mm , say 300 mm
3.286
Maximum spacing required by the code:
a. 3 ( h )=3 ( 150 )=450 mm okay !
b. 450 mm
Negative Moment:
Check ACI Table 13.4 for Two-way slab coefficients for m=0.75 case no .4
0.75 C s=0.076
0.75 C L =0.024
2
−Mu=C l w u L
kN
−Mu=( 0.024)(20.1888 )¿
m
kN
−Mu=7.752
m
To be safe in flexure:
1.4
ρ min =
fy
ρ min =0.00507
341
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
−s= =331.67 mm , say 300 m
3.015
1 ¯
d=h−covering ( usually 20 mm )− ( main diameter )
2
1
d=100−20− (12 )
2
d=74 mm
Dead load:
f. Roof
(
Rafters and Bracing - 0.24
kN
m
2 )
(1 m )=0.24 kN /m
g. Wall
(
Exterior Wall (6’’ CHB) - 3.45
kN
m
2 )
( 1 m) =3.45 kN /m
(kN
)
Interior Wall (CHB plastered) - 1.72 2 ( 1m )=1.72 kN /m
m
h. Floor Finishes
(
Ceramic 20 mm tiles - 1.1
kN
m
2 )
( 1m )=1.1 kN /m
i. Ceiling
( )
Ceiling loads - 1
kN
m2
( 1m )=1kN /m
j. Weight of slab -
kN
Total Dead Load=10.424
m
Live load:
(
Basic Floor Area (Residential) - 1.9
kN
m
2 )
( 1 m) =1.9 kN /m
(
Basic Floor Area (Balcony) - 2.9
kN
m
2)( 1 m )=2.9 kN /m
kN
Total Live Load=4.8
m
Compute for Wu:
Wu=1.2 ( D l ) +1.6 ( Ll )
(
Wu=1.2 10.424
kN
m ) (
+ 1.6 4.8
kN
m )
kN
Wu=20.1888
m
D. Check ACI Table 2 coefficients for dead load positive moment and live load positive moment in
Two-way slab if m=0.65 , case 4
Positive Moment:
Compute the moments using ACI coefficients
C s=0.050
C l=0.009
C Dl =0.050
+m
C ¿ =0.062
+m
+ Mu Dl =0.050(Wu Dl )¿ + Mu ¿=0.062(Wu¿ ) ¿
+ Mu Dl =0.050(10.424 kN /m)¿ + Mu ¿=0.062(4.8 kN /m) ¿
kN kN
+ Mu Dl =2.0848 (1.2) + Mu ¿=1.1904 (1.6)
m m
kN kN
+ Mu Dl =2.50176 + Mu ¿=1.90464
m m
+ Mu=4.4064 kN /m
To be safe in flexure:
2 '
Mu actual ≤ Mu allowable → ∅ b d f cw ( 1−0.59 w )
4.4064 ×106=(0.9)(1000)¿
w=0.0437
Compute the steel reinforcement:
Main Bar:
'
wf c
ρ=
fy
( 0.0437 )( 21 )
ρ=
276
ρ=0.003325
1.4
ρ min =
fy
ρ min =0.00507
327.82
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
s= =344.95 mm , say 300 mm
2.899
E. Negative Moment:
Check ACI Table 13.4 for Two-way slab coefficients for m=0.65 case no .4
0.65 C s=0.085
0.65 C L =0.015
0.65 C s=0.085
2
−Mu=C s wu s
kN
−Mu=(0.085)(20.1888 )¿
m
kN
−Mu=6.864
m
To be safe in flexure:
1.4
ρ min =
fy
ρ min =0.00507
ρ ≥ ρmin ( okay )
As= ρbd
As=( 0.00526 )( 1000 ) ( 124 )
As=329.24 mm2
389.24
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
−s= =290 mm , say 300 mm
3.935
1 ¯
d=h−covering ( usually 20 mm )− ( main diameter )
2
1
d=80−20− ( 12 )
2
d=54 mm
Dead load:
a. Roof
(
Metal roofing and purlins - 0.140
kN
m
2 )
( 1 m )=0.140 kN /m
Rafters and Bracing - 0.24 ( kN
m
2 )
(1 m )=0.24 kN /m
b. Wall
kN
( )
Interior Wall (CHB plastered) - 1.72 2 ( 1m )=1.72 kN /m
m
c. Floor Finishes
d. Ceiling
( kNm ) ( 1m )=1kN /m
Ceiling loads - 1 2
e. Weight of slab -
kN
Total Dead Load=10.424
m
Live load:
(
Basic Floor Area (Residential) - 1.9
kN
m2 )
( 1 m) =1.9 kN /m
(
Basic Floor Area (Balcony) - 2.9
kN
m2 )
( 1 m )=2.9 kN /m
kN
Total Live Load=4.8
m
Compute for Wu:
Wu=1.2 ( Dl ) +1.6 ( Ll )
Wu=1.2 6.634 ( kN
m ) (
+1.6 4.8
kN
m )
kN
Wu=20.1888
m
D. Check ACI Table 2 coefficients for dead load positive moment and live load positive moment in
Two-way slab if m=0.80 , case no . 6
Positive Moment:
Compute the moments using ACI coefficients
C s=0.034
C l=0.020
C Dl =0.034
+m
C ¿ =0.051
+m
+ Mu Dl=0.034(Wu Dl ) ¿ + Mu ¿=0.051(Wu¿ ) ¿
+ Mu Dl =0.034(10.424 kN /m)¿ + Mu ¿=0.051(4.8 kN /m) ¿
kN kN
+ Mu Dl =1.42 (1.2) + Mu ¿=0.979 (1.6)
m m
kN kN
+ Mu Dl =1.7 + Mu ¿=1.567
m m
+ Mu=3.267 kN /m
To be safe in flexure:
2 '
Mu actual ≤ Mu allowable → ∅ b d f cw ( 1−0.59 w )
6
3.267 ×10 =( 0.9)(1000) ¿
w=0.0617
Compute the steel reinforcement:
'
wf c
ρ=
fy
( 0.0617 )( 21 )
ρ=
276
ρ=0.00469
1.4
ρ min =
fy
ρ min =0.00507
Negative Moment:
Check ACI Table 13.4 for Two-way slab coefficients for m=0.80 case no .6
0.80 C s=0.086
0.80 C L =0.061
2
−Mu=C l w u s
kN
−Mu=(0.086)( 20.1888 )¿
m
kN
−Mu=4.9261
m
To be safe in flexure:
1.4
ρ min =
fy
ρ min =0.00507
ρ ≥ ρmin ( okay )
As= ρbd
As=( 0.00721 ) ( 1000 ) ( 54 )
As=389.43 mm2
389.43
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
−s= =290.70 mm , say 300 mm
3.015
Dead load:
f. Roof
g. Wall
kN
( )
Interior Wall (CHB plastered) - 1.72 2 ( 1m )=1.72 kN /m
m
h. Floor Finishes
i. Ceiling
( kNm ) ( 1m )=1kN /m
Ceiling loads - 1 2
j. Weight of slab -
Live load:
(
Basic Floor Area (Residential) - 1.9
kN
m2 )
( 1 m) =1.9 kN /m
(
Basic Floor Area (Balcony) - 2.9
kN
m2 )
( 1 m )=2.9 kN /m
kN
Total Live Load=4.8
m
Compute for Wu:
Wu=1.2 ( Dl ) +1.6 ( Ll )
(
Wu=1.2 6.634
kN
m ) (
+1.6 4.8
kN
m )
kN
Wu=20.1888
m
D. Check ACI Table 2 coefficients for dead load positive moment and live load positive moment in
Two-way slab if m=0.60 , case no . 4
Positive Moment:
C s=0.053
C l=0.007
C Dl =0.053
+m
C ¿ =0.067
+m
+ Mu Dl=0.053(Wu Dl )¿ + Mu ¿=0.067(Wu ¿ )¿
+ Mu Dl =0.053(10.424 kN /m)¿ + Mu ¿=0.067(4.8 kN /m) ¿
kN kN
+ Mu Dl =3.453 (1.2) + Mu ¿=2.01 (1.6)
m m
kN kN
+ Mu Dl =4.144 + Mu ¿=3.216
m m
+ Mu=7.36 kN /m
To be safe in flexure:
2 '
Mu actual ≤ Mu allowable → ∅ b d f cw ( 1−0.59 w )
6
7.36 ×10 =(0.9)(1000)¿
w=0.0257
Compute the steel reinforcement:
'
wf c
ρ=
fy
( 0.0257 )( 21 )
ρ=
276
ρ=0.00196
1.4
ρ min =
fy
ρ min =0.00507
428.64
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
s= =349.65 mm , say 300 mm
2.86
Check ACI Table 13.4 for Two-way slab coefficients for m=0.65 case no .6
0.65 C s=0.089
2
−Mu=C l w u s
kN
−Mu=(0.089)(20.1888 )¿
m
kN
−Mu=4.9261
m
To be safe in flexure:
1.4
ρ min =
fy
ρ min =0.00507
ρ ≥ ρmin ( okay )
As= ρbd
As=( 0.00721 ) ( 1000 ) ( 54 )
As=389.43 mm2
389.43
N of 12mm ∅ bars=
π
¿¿
4
Compute for spacing:
1000
−s= =290.70 mm , say 300 mm
3.015
1
2
3
4
6
7