You are on page 1of 293

ALIRAN 16

Komponen BM Kmol/Jam Kg/Jam Fraksi Mol


Metanol 32.042 0.0954 3.0582 0.0002
Asam Asetat 60.052 445.9260 26,778.7500 0.9961
Air 18.025 1.6291 29.3644 0.0036
Total 447.6506 26,811.1726 1.0000

Kondisi Operasi
Tc= 300.3932057 F
422.2573365 K
149.1073365 oC
P= 4 Atm
bar
t standar= 77 F
298.15 K
25 C

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Asam Asetat -3.8937 784.82 0.0067 -0.0000075606
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Asam Asetat -18.944 1.0971 -0.0028921 0.0000029275
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.14607500745874
Asam Asetat -1.2836 0.5893 592.71 -1.22918536133311
Air -0.2758 0.004612 -0.0000055391 0
Total

Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13

FL

Kondisi Operasi
tc= 117.5 F
320.65 K
47.5 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 16)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.824264014456025 0.14987734305265 0.0002 3.19549319539746E-05


-0.554010701569444 0.27924750302464 0.9961 0.278171725003815
-0.492360629138468 0.32183951927091 0.0036 0.00117124174787489
1.0000 0.2794

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
97.6630910606606 0.0002 0.0208224763376144 0.000649849458136647
149.058044592163 0.9961 148.483810744186 2.47258727010235
77.8119212175831 0.0036 0.283173958309545 0.0157100670352036
1.0000 148.7878 2.4889

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0714372935316061 0.0002 1.5230946901539E-05 8.80348730908952E-06
0.0589949230055653 0.9961 0.058767649920498 0.0339677016540478
0.684022336486565 0.0036 0.00248930124798505 0.00143881612133536
1 0.0612721821153846 0.0354153212626923
T= 422.257336504689
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.648421332265263 0.0002 0.00013824811094205 0.138248110942051
0.899101642970962 0.9961 0.89563792789555 895.63792789555
0.903956174485785 0.0036 0.00328968677372344 3.28968677372344
0.899065862780216 899.065862780216

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.0984997570231989 0.7970769365346 1 0.7970769365346

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.1724267461282 1 75.1724267461282 4.17045363362709

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.63352735413025 1 0.63352735413025 0.366178810687284
T= 320.65
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.00663604346522 1 1.00663604346522 1006.63604346522
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144

μ mix (lb/ft jam)

7.72989804E-05
0.6728974027842
0.0028332337881
0.6758

Cp mix (Btu/lb F)
0.000154664171
0.5884757702844
0.0037389959544
0.5924
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.0086315996993 0.7872443337914 0.0002 0.000167846177448052 0.167846177448052
55.919665132782 1.0429408715507 0.9961 1.03892302768643 1038.92302768643
0.2053934710096 1.0274529145287 0.0036 0.00373911740297734 3.73911740297734
56.133690203491 1.04282999126685 1042.82999126685

μ mix (lb/ft jam)

1.9281291094772

Cp mix (Btu/lb F)
0.9925679648032
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
62.849895820544 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.0104795718720469
64.8657521052816
0.23345392881914
65.1096856059728
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan
Tipe: Dou
Gambar:

Fluida Panas: Aliran 16 Shell (Annulus)


Flow Rate (W1): 26,811.1726 Kg/Jam
T1: 169.7029 oC
T2: 128.5118 oC

Fluida Dingin: Cooling water Tube (Inner Pipe)


Flow Rate (W2): 15.9941 Kg/Jam
t1: 27.0000 oC
t2: 68.0000 oC

1. Beban Panas Heater (Q)


Q= 2,745,652.5837 Kj/Jam
2,602,376.5253 Btu/Jam

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T) Fluida Dingin (t)
Suhu Tinggi 337.4651 154.4000
Suhu Rendah 263.3213 80.6000
Selisih

Dt= LMTD= 183.0987 F

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2= 300.3932
tc = tavg = (t1+t2)/2= 117.5000

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000 Btu/Jam ft2 F


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 94.7531 ft2

Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger

Menentukan Spesifikasi Shell (Annulus) dan Tube (Inner Pipe)

Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft

4. Menghitung flow area (a) both sides


Shell (annulus) (aa)

Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 4.5000 in
Maka, aa= 0.2368 ft2

Equivalent Diameter (DE)

De = 0.8046 ft

Tube (inner pipe) (ap) Sumber : Process Heat Tran

D= 4.0260 in
ap= 0.0884 ft2

5. Menghitung Mass Velocity (G)


Shell (annulus) (Ga)

Ga = 249,565.7828 lb/ft2 jam

Tube (inner pipe) (Gp)

Gp = 399.0560 lb/ft2 jam

6. Menghitung Reynold Number (Re)


Shell (annulus) (Rea)

Pada Tc, 300.3932 F


Nilai μ pada Tc = 0.6758 lb/ft jam
Maka, Nilai Rea = 297,112.8258

Tube (inner pipe) (Rep) Sumber : Process Heat Tran

Pada tc, 117.5000 F


Nilai μ pada tc = 1.9281 lb/ft jam
Maka, Nilai Rep = 69.4369

7. Menentukan nilai jH dari fig 14.

Shell (annulus)
jH= 300.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran

Pada Tc= 300.3932 F


Cp= 148.7878 kJ/Kmol.K
μ= 0.2794 cP
k (konduktivitas thermal)= 0.0613 W.m/K

Pr= 11.3038
Pr^(1/3) = 2.2443

Tube (inner pipe) (Prp) Sumber : Process Heat Tran


Pada tc= 117.5000 F
Cp= 75.1724 kJ/Kmol.K
μ= 0.7971 cP
k (konduktivitas thermal)= 0.6335 W.m/K

Pr= 5.2264
Pr^(1/3) = 1.7354

9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran

Ho = 29.6366 Btu/jam ft2 F

Tube (inner pipe) (hi) Sumber : Process Heat Tran

Hi = 2.8411 Btu/jam ft2 F

10. Konversi nilai hi menjadi hio pada inner pipe

OD = 4.5000 in
ID = 4.0260 in
Hio = 2.5419 Btu/hr ft2 F

11. Menghitung Clean Overall Coefficient (Uc)

Uc = 2.3411 Btu/hr ft2 F

12. Menghitung Design Overall Coefficient (Ud)

Sumber : Process Heat Transfer by


Sumber : Process Heat Transfer by

Pers. Umum

Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040

Maka,
Rd= 0.0040
1/Ud= 0.4312
Ud= 2.3194 Btu/hr ft2 F

13. Menghitung required surface area (A)

A= 6,127.9565 ft2

Next step 13.


Required length (L)= A/a" = 5,202.0005
dimana, A (surface area) dan a" (surface per pipe outside)
inner pippe

Panjang 1 hairpin= 40.0000 ft (20 @pipe)


Jumlah hairpin= 130.0500
131.0000 buah hairpin
Actual length (L)= 5,240.0000 ft
Actual surface= L x a"
6,172.7200 ft2
Ud actual= 2.3025 Btu/hr ft2 F
Rd actual= 0.0071 hr ft2 F/Btu

14. Menghitung Pressure Drop


Shell (annulus)
1)

D'e (Diameter equivalent)

D'e= D2-D1
D'e= 0.2901 ft

2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112

Rea= 107,123.4449

3) Friction factor (f)


Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0055

4) ΔFa (pressure drop, expressed in feet of liquid)

ρref = 65.1097 lbf/ft3


ρ= 56.1337 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.1599
Δfa= 9.4598 ft

5) V (pressure drop on velocity head of the shell side/annulus)

V= 1.2350 ft/s

6)

g'= 32.2000 Kern pp.112


ft= Jumlah hairpins x (V^2/2g')= 3.1024 ft
ΔPa = 4.1690 psi
Allowable Pressure drop = 10 psi (Kern pp.112)

Tube (inner pipe)


1) Friction factor (f) (turbulent flow, commercial pipes)
Rep= 69.4369

Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0480

2) ΔFp (pressure drop, expressed in feet of liquid)


Sumber : Process Heat Transfer by Kern Hal. 112

ρref = 64.1496 lbf/ft3


ρ= 62.8499 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0207
Δfp= 0.0001 ft

3) ΔPp

ΔPp= 6.30850894655E-05 psi


Allowable Pressure drop = 10 psi (Kern pp.112)

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 4.16901 psi
COOLER-01
Mendinginkan aliran 15 sebelum masuk ke EDC-01
Double-Pipe Heat Exchanger

59,107.9111 lb/Jam 1.0000 kg 1.0000


337.4651 F 2.2046 lb 35.3100
263.3213 F

35.2605 lb/Jam
Return bend Gland
80.6000 F
154.4000 F

Return Head

Sumber: Process Heat Transfer by Kern Hal: 89


Selisih
183.0651 T2-t2
182.7213 T1-t1
0.3439

F
F

Sumber: Process Heat Transfer by Kern Hal: 840 Tabel. 8


Tube (Inner Pipe ) Sumber : Process Heat Transfer by Kern Tabel 11. Hal. 8
Nominal Pipe Size, IPS 4.0000 in
Schedule. No. 40.0000
OD 4.5000 in
ID 4.0260 in
a" (surface per pipe) outside 1.1780 ft2/ft
a" (surface per pipe) inside 1.0550 ft2/ft

Sumber : Process Heat Transfer by Kern Hal. 111

0.6651 ft 0.4423 ft2


0.3750 ft 0.1406 ft2

mber : Process Heat Transfer by Kern Hal. 111

0.3355 ft
Sumber : Process Heat Transfer by Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 111

Sumber : Process Heat Transfer by Kern Hal. 112

mber : Process Heat Transfer by Kern Hal. 111

Sumber: Process Heat Transfer by Kern Hal: 834


mber : Process Heat Transfer by Kern Hal. 112

0.5924 Btu/lb F
0.6758 lb/ft jam
0.0354 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 111


0.9926 Btu/lb F
1.9281 lb/ft jam
0.3662 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 112

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

mber : Process Heat Transfer by Kern Hal. 111

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

Sumber : Process Heat Transfer by Kern Hal. 111

0.3750 ft
0.3355 ft

Sumber : Process Heat Transfer by Kern Hal. 112

rocess Heat Transfer by Kern Hal. 106


rocess Heat Transfer by Kern Hal. 106

Sumber : Process Heat Transfer by


Kern Hal. 107

Sumber : Process Heat Transfer by Kern Hal. 114

Sumber : Process Heat Transfer by Kern Hal. 103

ft

20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 112


Accepted!

Accepted!
Cooler
C-01
1 buah
Kontinyu
Mendinginkan aliran 15 sebelum masuk ke EDC-01

Double Pipe Heat Exchanger


131.0000 buah
Stainlees Steel
0.0071 hr ft2 F/Btu
2.3411 Btu/hr ft2 F
2.3194 Btu/hr ft2 F
29.6366 Btu/hr ft2 F
2.5419 Btu/hr ft2 F
INNER PIPE SIDE
IPS 4.0000 in
SN 40.0000
OD 4.5000 in
ID 4.0260 in
a" 1.1780 ft2/ft
ΔPp 0.0001 psi
m^3 1.0000 cP 1.0000 mmHg
ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000 psi
2.7792 lbf/ft^2 144.0000 lbf/ft^2

Gland
Gland

Tee

Kern Hal: 89

40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 26
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.0000 0.0000 0.0000
Asam Asetat 60.052 445.9260 26,778.7500 0.9967
Air 18.025 1.4871 26.8056 0.0033
Total 447.4132 26,805.5556 1.0000

Kondisi Operasi
Tc= 253.1291495 F
395.9995275 K
122.8495275 oC
P= 3 Atm
bar
t standar= 77 F
298.15 K
25 C

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Asam Asetat -3.8937 784.82 0.0067 -0.0000075606
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Asam Asetat -18.944 1.0971 -0.0028921 0.0000029275
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.13542603360273
Asam Asetat -1.2836 0.5893 592.71 -1.21946318483423
Air -0.2758 0.004612 -0.0000055391 0
Total

Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13

FL

Kondisi Operasi
tc= 101.3 F
311.65 K
38.5 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 26)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.709761287416323 0.19509166382121 0.0000 0.00


-0.444252334411995 0.35954037378481 0.9967 0.358345314911555
-0.434437899666484 0.36775797581058 0.0033 0.00122237296350402
1.0000 0.359567687875059

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
92.3670470558569 0.0000 0.00 0.00
143.775180197326 0.9967 143.297292823956 2.38622015626383
76.3424975427973 0.0033 0.253751138250647 0.0140777330513535
1.0000 143.5510 2.4003

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.07321060004279 0.0000 0.00 0.00
0.060330484794228 0.9967 0.0601299552113548 0.0347551141121631
0.681932388070201 0.0033 0.00226664210960336 0.00131011913935074
1 0.0623965973209582 0.0360652332515138
T= 395.999527497491
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.683887091573007 0.0000 0.00 0.00
0.932794140505738 0.9967 0.929693671140373 929.693671140373
0.932122507656093 0.0033 0.00309823695739303 3.09823695739303
0.932791908097766 932.791908097766

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.0325377521232812 0.92781683384593 1 0.927816833845927

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2898616772476 1 75.2898616772476 4.17696874769751

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62354071050025 1 0.62354071050025 0.360406530669144
T= 311.65
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01503080894644 1 1.01503080894644 1015.03080894644
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144

μ mix (lb/ft jam)

0.00
0.8668373167711
0.0029569201987
0.87

Cp mix (Btu/lb F)
0.00
0.5679203971908
0.0033505004662
0.5713
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.00 0.7872443337914 0.0000 0.00 0.00
58.045954896519 1.0429408715507 0.9967 1.03947429078895 1039.47429078895
0.1934401924743 1.0274529145287 0.0033 0.0034151010898542 3.4151010898542
58.239395088993 1.04288939187881 1042.88939187881

μ mix (lb/ft jam)

2.2443889210733

Cp mix (Btu/lb F)
0.994118561952
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.37402779392 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.00
64.9001705316717
0.21322378540619
65.1133943170779
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan ali
Tipe: Dou
Gambar:

Fluida Panas: Aliran 26 Shell (Annulus)


Flow Rate (W1): 26,805.5556 Kg/Jam
T1: 157.8495 oC
T2: 87.8495 oC

Fluida Dingin: Cooling water Tube (Inner Pipe)


Flow Rate (W2): 46.7633 Kg/Jam
t1: 27.0000 oC
t2: 50.0000 oC

1. Beban Panas Heater (Q)


Q= 4,503,348.1250 Kj/Jam
4,268,350.4516 Btu/Jam

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T) Fluida Dingin (t)
Suhu Tinggi 316.1291 122.0000
Suhu Rendah 190.1291 80.6000
Selisih

Dt= LMTD= 147.9822 F

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2= 253.1291
tc = tavg = (t1+t2)/2= 101.3000

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000 Btu/Jam ft2 F


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 192.2912 ft2

Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger

Menentukan Spesifikasi Shell (Annulus) dan Tube (Inner Pipe)

Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft

4. Menghitung flow area (a) both sides


Shell (annulus) (aa)

Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 4.5000 in
Maka, aa= 0.2368 ft2

Equivalent Diameter (DE)

De = 0.8046 ft

Tube (inner pipe) (ap) Sumber : Process Heat Tran

D= 4.0260 in
ap= 0.0884 ft2

5. Menghitung Mass Velocity (G)


Shell (annulus) (Ga)

Ga = 249,513.4984 lb/ft2 jam

Tube (inner pipe) (Gp)

Gp = 1,166.7554 lb/ft2 jam

6. Menghitung Reynold Number (Re)


Shell (annulus) (Rea)

Pada Tc, 253.1291 F


Nilai μ pada Tc = 0.8698 lb/ft jam
Maka, Nilai Rea = 230,800.7237

Tube (inner pipe) (Rep) Sumber : Process Heat Tran

Pada tc, 101.3000 F


Nilai μ pada tc = 2.2444 lb/ft jam
Maka, Nilai Rep = 174.4111

7. Menentukan nilai jH dari fig 14.

Shell (annulus)
jH= 300.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran

Pada Tc= 253.1291 F


Cp= 2.4003 kJ/Kmol.K
μ= 0.3596 cP
k (konduktivitas thermal)= 0.0624 W.m/K

Pr= 13.7775
Pr^(1/3) = 2.3973

Tube (inner pipe) (Prp) Sumber : Process Heat Tran


Pada tc= 101.3000 F
Cp= 75.2899 kJ/Kmol.K
μ= 0.9278 cP
k (konduktivitas thermal)= 0.6235 W.m/K

Pr= 6.1908
Pr^(1/3) = 1.8362

9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran

Ho = 32.2384 Btu/jam ft2 F

Tube (inner pipe) (hi) Sumber : Process Heat Tran

Hi = 2.9587 Btu/jam ft2 F

10. Konversi nilai hi menjadi hio pada inner pipe

OD = 4.5000 in
ID = 4.0260 in
Hio = 2.6471 Btu/hr ft2 F

11. Menghitung Clean Overall Coefficient (Uc)

Uc = 2.4462 Btu/hr ft2 F

12. Menghitung Design Overall Coefficient (Ud)

Sumber : Process Heat Transfer by


Sumber : Process Heat Transfer by

Pers. Umum

Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040

Maka,
Rd= 0.0040
1/Ud= 0.4128
Ud= 2.4225 Btu/hr ft2 F

13. Menghitung required surface area (A)

A= 11,906.4828 ft2

Next step 13.


Required length (L)= A/a" = 10,107.3708
dimana, A (surface area) dan a" (surface per pipe outside)
inner pippe

Panjang 1 hairpin= 40.0000 ft (20 @pipe)


Jumlah hairpin= 252.6843
253.0000 buah hairpin
Actual length (L)= 10,120.0000 ft
Actual surface= L x a"
11,921.3600 ft2
Ud actual= 2.4195 Btu/hr ft2 F
Rd actual= 0.0045 hr ft2 F/Btu

14. Menghitung Pressure Drop


Shell (annulus)
1)

D'e (Diameter equivalent)

D'e= D2-D1
D'e= 0.2901 ft

2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112

Rea= 83,214.7469

3) Friction factor (f)


Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0058

4) ΔFa (pressure drop, expressed in feet of liquid)

ρref = 65.1134 lbf/ft3


ρ= 58.2394 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.1180
Δfa= 17.6639 ft

5) V (pressure drop on velocity head of the shell side/annulus)

V= 1.1901 ft/s

6)

g'= 32.2000 Kern pp.112


ft= Jumlah hairpins x (V^2/2g')= 5.5640 ft
ΔPa = 7.6253 psi
Allowable Pressure drop = 10 psi (Kern pp.112)

Tube (inner pipe)


1) Friction factor (f) (turbulent flow, commercial pipes)
Rep= 174.4111

Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0337

2) ΔFp (pressure drop, expressed in feet of liquid)


Sumber : Process Heat Transfer by Kern Hal. 112

ρref = 64.1496 lbf/ft3


ρ= 63.3740 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0122
Δfp= 0.0016 ft

3) ΔPp

ΔPp= 0.000725736804191 psi


Allowable Pressure drop = 10 psi (Kern pp.112)

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 7.62529 psi
COOLER-02
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Double-Pipe Heat Exchanger

59,095.5279 lb/Jam 1.0000 kg 1.0000


316.1291 F 2.2046 lb 35.3100
190.1291 F

103.0943 lb/Jam
Return bend Gland
80.6000 F
122.0000 F

Return Head

Sumber: Process Heat Transfer by Kern Hal: 89


Selisih
194.1291 T2-t2
109.5291 T1-t1
84.6000

F
F

Sumber: Process Heat Transfer by Kern Hal: 840 Tabel. 8


Tube (Inner Pipe ) Sumber : Process Heat Transfer by Kern Tabel 11. Hal. 8
Nominal Pipe Size, IPS 4.0000 in
Schedule. No. 40.0000
OD 4.5000 in
ID 4.0260 in
a" (surface per pipe) outside 1.1780 ft2/ft
a" (surface per pipe) inside 1.0550 ft2/ft

Sumber : Process Heat Transfer by Kern Hal. 111

0.6651 ft 0.4423 ft2


0.3750 ft 0.1406 ft2

mber : Process Heat Transfer by Kern Hal. 111

0.3355 ft
Sumber : Process Heat Transfer by Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 111

Sumber : Process Heat Transfer by Kern Hal. 112

mber : Process Heat Transfer by Kern Hal. 111

Sumber: Process Heat Transfer by Kern Hal: 834


mber : Process Heat Transfer by Kern Hal. 112

0.5713 Btu/lb F
0.8698 lb/ft jam
0.0361 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 111


0.9941 Btu/lb F
2.2444 lb/ft jam
0.3604 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 112

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

mber : Process Heat Transfer by Kern Hal. 111

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

Sumber : Process Heat Transfer by Kern Hal. 111

0.3750 ft
0.3355 ft

Sumber : Process Heat Transfer by Kern Hal. 112

rocess Heat Transfer by Kern Hal. 106


rocess Heat Transfer by Kern Hal. 106

Sumber : Process Heat Transfer by


Kern Hal. 107

Sumber : Process Heat Transfer by Kern Hal. 114

Sumber : Process Heat Transfer by Kern Hal. 103

ft

20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 112


Accepted!

Accepted!
Cooler
C-01
1 buah
Kontinyu
Mendinginkan aliran 26 sebelum masuk ke tangki produk

Double Pipe Heat Exchanger


253.0000 buah
Stainlees Steel
0.0045 hr ft2 F/Btu
2.4462 Btu/hr ft2 F
2.4225 Btu/hr ft2 F
32.2384 Btu/hr ft2 F
2.6471 Btu/hr ft2 F
INNER PIPE SIDE
IPS 4.0000 in
SN 40.0000
OD 4.5000 in
ID 4.0260 in
a" 1.1780 ft2/ft
ΔPp 0.0007 psi
m^3 1.0000 cP 1.0000 mmHg
ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000 psi
2.7792 lbf/ft^2 144.0000 lbf/ft^2

Gland
Gland

Tee

Kern Hal: 89

40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 26
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.0000 0.0000 0.0000
Asam Asetat 60.052 445.9260 26,778.7500 0.9967
Air 18.025 1.4871 26.8056 0.0033
Total 447.4132 26,805.5556 1.0000

Kondisi Operasi
Tc= 163.1291495 F
345.9995275 K
72.8495275 oC
P= 3 Atm
bar
t standar= 77 F
298.15 K
25 C

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Asam Asetat -3.8937 784.82 0.0067 -0.0000075606
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Asam Asetat -18.944 1.0971 -0.0028921 0.0000029275
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.11366504963506
Asam Asetat -1.2836 0.5893 592.71 -1.1995960943724
Air -0.2758 0.004612 -0.0000055391 0
Total

Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13

FL

Kondisi Operasi
tc= 101.3 F
311.65 K
38.5 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 26)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.498817654310404 0.31708985375522 0.0000 0.00


-0.212356489731914 0.61325840660286 0.9967 0.611220026621515
-0.248955061446885 0.56369598116117 0.0033 0.00187364183057772
1.0000 0.613093668452093

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
84.8388166807696 0.0000 0.00 0.00
135.684019000624 0.9967 135.233025446942 2.25193208297711
75.1133796846544 0.0033 0.249665732800385 0.0138510808765817
1.0000 135.4827 2.2658

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0769723862268872 0.0000 0.00 0.00
0.063154442485305 0.9967 0.0629445264859332 0.0363819363088694
0.656832736346336 0.0033 0.0021832145902056 0.00126189803313883
1 0.0651277410761388 0.0376438343420082
T= 345.999527497491
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.740841082497788 0.0000 0.00 0.00
0.991582650903198 0.9967 0.98828677724914 988.28677724914
0.982463515760517 0.0033 0.00326556300144891 3.26556300144891
0.991552340250589 991.552340250589

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.0325377521232812 0.92781683384593 1 0.927816833845927

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2898616772476 1 75.2898616772476 4.17696874769751

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62354071050025 1 0.62354071050025 0.360406530669144
T= 311.65
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01503080894644 1 1.01503080894644 1015.03080894644
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144

μ mix (lb/ft jam)

0.00
1.4785412443975
0.0045323395882
1.48

Cp mix (Btu/lb F)
0.00
0.5359598357486
0.0032965572486
0.5393
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.00 0.7872443337914 0.0000 0.00 0.00
61.704248913154 1.0429408715507 0.9967 1.03947429078895 1039.47429078895
0.2038872895212 1.0274529145287 0.0033 0.0034151010898542 3.4151010898542
61.908136202675 1.04288939187881 1042.88939187881

μ mix (lb/ft jam)

2.2443889210733

Cp mix (Btu/lb F)
0.994118561952
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.37402779392 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.00
64.9001705316717
0.21322378540619
65.1133943170779
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan ali
Tipe: Dou
Gambar:

Fluida Panas: Aliran 26 Shell (Annulus)


Flow Rate (W1): 26,805.5556 Kg/Jam
T1: 87.8495 oC
T2: 57.8495 oC

Fluida Dingin: Cooling water Tube (Inner Pipe)


Flow Rate (W2): 18.8851 Kg/Jam
t1: 27.0000 oC
t2: 50.0000 oC

1. Beban Panas Heater (Q)


Q= 1,818,650.4737 Kj/Jam
1,723,748.0548 Btu/Jam

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T) Fluida Dingin (t)
Suhu Tinggi 190.1291 122.0000
Suhu Rendah 136.1291 80.6000
Selisih

Dt= LMTD= 61.6838 F

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2= 163.1291
tc = tavg = (t1+t2)/2= 101.3000

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000 Btu/Jam ft2 F


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 186.2993 ft2

Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger

Menentukan Spesifikasi Shell (Annulus) dan Tube (Inner Pipe)

Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft

4. Menghitung flow area (a) both sides


Shell (annulus) (aa)

Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 4.5000 in
Maka, aa= 0.2368 ft2

Equivalent Diameter (DE)

De = 0.8046 ft

Tube (inner pipe) (ap) Sumber : Process Heat Tran

D= 4.0260 in
ap= 0.0884 ft2

5. Menghitung Mass Velocity (G)


Shell (annulus) (Ga)

Ga = 249,513.4984 lb/ft2 jam

Tube (inner pipe) (Gp)

Gp = 471.1873 lb/ft2 jam

6. Menghitung Reynold Number (Re)


Shell (annulus) (Rea)

Pada Tc, 163.1291 F


Nilai μ pada Tc = 1.4831 lb/ft jam
Maka, Nilai Rea = 135,360.2016

Tube (inner pipe) (Rep) Sumber : Process Heat Tran

Pada tc, 101.3000 F


Nilai μ pada tc = 2.2444 lb/ft jam
Maka, Nilai Rep = 70.4349

7. Menentukan nilai jH dari fig 14.

Shell (annulus)
jH= 300.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran

Pada Tc= 163.1291 F


Cp= 135.4827 kJ/Kmol.K
μ= 0.6131 cP
k (konduktivitas thermal)= 0.0651 W.m/K

Pr= 21.2454
Pr^(1/3) = 2.7696

Tube (inner pipe) (Prp) Sumber : Process Heat Tran


Pada tc= 101.3000 F
Cp= 75.2899 kJ/Kmol.K
μ= 0.9278 cP
k (konduktivitas thermal)= 0.6235 W.m/K

Pr= 6.1908
Pr^(1/3) = 1.8362

9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran

Ho = 38.8756 Btu/jam ft2 F

Tube (inner pipe) (hi) Sumber : Process Heat Tran

Hi = 2.9587 Btu/jam ft2 F

10. Konversi nilai hi menjadi hio pada inner pipe

OD = 4.5000 in
ID = 4.0260 in
Hio = 2.6471 Btu/hr ft2 F

11. Menghitung Clean Overall Coefficient (Uc)

Uc = 2.4783 Btu/hr ft2 F

12. Menghitung Design Overall Coefficient (Ud)

Sumber : Process Heat Transfer by


Sumber : Process Heat Transfer by

Pers. Umum

Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040

Maka,
Rd= 0.0040
1/Ud= 0.4075
Ud= 2.4540 Btu/hr ft2 F

13. Menghitung required surface area (A)

A= 11,387.4810 ft2

Next step 13.


Required length (L)= A/a" = 9,666.7920
dimana, A (surface area) dan a" (surface per pipe outside)
inner pippe

Panjang 1 hairpin= 40.0000 ft (20 @pipe)


Jumlah hairpin= 241.6698
242.0000 buah hairpin
Actual length (L)= 9,680.0000 ft
Actual surface= L x a"
11,403.0400 ft2
Ud actual= 2.4507 Btu/hr ft2 F
Rd actual= 0.0046 hr ft2 F/Btu

14. Menghitung Pressure Drop


Shell (annulus)
1)

D'e (Diameter equivalent)

D'e= D2-D1
D'e= 0.2901 ft

2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112

Rea= 48,803.8544

3) Friction factor (f)


Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0063

4) ΔFa (pressure drop, expressed in feet of liquid)

ρref = 65.1134 lbf/ft3


ρ= 61.9081 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0518
Δfa= 16.4286 ft

5) V (pressure drop on velocity head of the shell side/annulus)

V= 1.1196 ft/s

6)

g'= 32.2000 Kern pp.112


ft= Jumlah hairpins x (V^2/2g')= 4.7100 ft
ΔPa = 7.5443 psi
Allowable Pressure drop = 10 psi (Kern pp.112)

Tube (inner pipe)


1) Friction factor (f) (turbulent flow, commercial pipes)
Rep= 70.4349

Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0477

2) ΔFp (pressure drop, expressed in feet of liquid)


Sumber : Process Heat Transfer by Kern Hal. 112

ρref = 64.1496 lbf/ft3


ρ= 63.3740 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0122
Δfp= 0.0004 ft

3) ΔPp

ΔPp= 0.000160239949926 psi


Allowable Pressure drop = 10 psi (Kern pp.112)

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 7.54426 psi
COOLER-02
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Double-Pipe Heat Exchanger

59,095.5279 lb/Jam 1.0000 kg 1.0000


190.1291 F 2.2046 lb 35.3100
136.1291 F

41.6340 lb/Jam
Return bend Gland
80.6000 F
122.0000 F

Return Head

Sumber: Process Heat Transfer by Kern Hal: 89


Selisih
68.1291 T2-t2
55.5291 T1-t1
12.6000

F
F

Sumber: Process Heat Transfer by Kern Hal: 840 Tabel. 8


Tube (Inner Pipe ) Sumber : Process Heat Transfer by Kern Tabel 11. Hal. 8
Nominal Pipe Size, IPS 4.0000 in
Schedule. No. 40.0000
OD 4.5000 in
ID 4.0260 in
a" (surface per pipe) outside 1.1780 ft2/ft
a" (surface per pipe) inside 1.0550 ft2/ft

Sumber : Process Heat Transfer by Kern Hal. 111

0.6651 ft 0.4423 ft2


0.3750 ft 0.1406 ft2

mber : Process Heat Transfer by Kern Hal. 111

0.3355 ft
Sumber : Process Heat Transfer by Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 111

Sumber : Process Heat Transfer by Kern Hal. 112

mber : Process Heat Transfer by Kern Hal. 111

Sumber: Process Heat Transfer by Kern Hal: 834


mber : Process Heat Transfer by Kern Hal. 112

0.5393 Btu/lb F
1.4831 lb/ft jam
0.0376 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 111


0.9941 Btu/lb F
2.2444 lb/ft jam
0.3604 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 112

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

mber : Process Heat Transfer by Kern Hal. 111

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

Sumber : Process Heat Transfer by Kern Hal. 111

0.3750 ft
0.3355 ft

Sumber : Process Heat Transfer by Kern Hal. 112

rocess Heat Transfer by Kern Hal. 106


rocess Heat Transfer by Kern Hal. 106

Sumber : Process Heat Transfer by


Kern Hal. 107

Sumber : Process Heat Transfer by Kern Hal. 114

Sumber : Process Heat Transfer by Kern Hal. 103

ft

20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 112


Accepted!

Accepted!
Cooler
C-01
1 buah
Kontinyu
Mendinginkan aliran 26 sebelum masuk ke tangki produk

Double Pipe Heat Exchanger


242.0000 buah
Stainlees Steel
0.0046 hr ft2 F/Btu
2.4783 Btu/hr ft2 F
2.4540 Btu/hr ft2 F
38.8756 Btu/hr ft2 F
2.6471 Btu/hr ft2 F
INNER PIPE SIDE
IPS 4.0000 in
SN 40.0000
OD 4.5000 in
ID 4.0260 in
a" 1.1780 ft2/ft
ΔPp 0.0002 psi
m^3 1.0000 cP 1.0000 mmHg
ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000 psi
2.7792 lbf/ft^2 144.0000 lbf/ft^2

Gland
Gland

Tee

Kern Hal: 89

40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 26
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.0000 0.0000 0.0000
Asam Asetat 60.052 445.9260 26,778.7500 0.9967
Air 18.025 1.4871 26.8056 0.0033
Total 447.4132 26,805.5556 1.0000

Kondisi Operasi
Tc= 111.8291495 F
317.4995275 K
44.3495275 oC
P= 3 Atm
bar
t standar= 77 F
298.15 K
25 C

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Asam Asetat -3.8937 784.82 0.0067 -0.0000075606
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Asam Asetat -18.944 1.0971 -0.0028921 0.0000029275
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.10023734657481
Asam Asetat -1.2836 0.5893 592.71 -1.18733702595026
Air -0.2758 0.004612 -0.0000055391 0
Total

Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13

FL

Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 26)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.366738935030879 0.42979470917355 0.0000 0.00


-0.0567289366542306 0.87754836892303 0.9967 0.874631528308016
-0.0762431792581861 0.8389900700848 0.0033 0.00278867854887325
1.0000 0.877420206856889

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
81.7056275967038 0.0000 0.00 0.00
131.540944672281 0.9967 131.10372208314 2.18316995409212
75.2080651393892 0.0033 0.249980453207603 0.0138685410933483
1.0000 131.3537 2.1970

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0793894244457544 0.0000 0.00 0.00
0.0649625365306728 0.9967 0.0647466106948817 0.0374235409816416
0.630133583388733 0.0033 0.0020944705659546 0.00121060398712176
1 0.0668410812608363 0.0386341449687634
T= 317.499527497491
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.769210797365482 0.0000 0.00 0.00
1.02265715339289 0.9967 1.01925799270172 1019.25799270172
1.00958529383225 0.0033 0.00335571176889296 3.35571176889296
1.02261370447061 1022.61370447061

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.059068484217204 0.87283371974234 1 0.872833719742336

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2385029680882 1 75.2385029680882 4.17411944344456

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144

μ mix (lb/ft jam)

0.00
2.1157336669771
0.0067458134097
2.12

Cp mix (Btu/lb F)
0.00
0.5195944490739
0.0033007127802
0.5229
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.00 0.7872443337914 0.0000 0.00 0.00
63.637954423965 1.0429408715507 0.9967 1.03947429078895 1039.47429078895
0.2095157792609 1.0274529145287 0.0033 0.0034151010898542 3.4151010898542
63.847470203226 1.04288939187881 1042.88939187881

μ mix (lb/ft jam)

2.1113847680567

Cp mix (Btu/lb F)
0.9934404275398
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.1708900629 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.00
64.9001705316717
0.21322378540619
65.1133943170779
ρ standar mix (lb/ft3)
64.1496090447448
COOL
Fungsi: Mendingink
Tipe:
Gambar:

Fluida Panas: Aliran 26


Flow Rate (W1): 26,805.5556
T1: 57.8495
T2: 30.8495

Fluida Dingin: Cooling Water


Flow Rate (W2): 12.6319
t1: 27.0000
t2: 57.0000

1. Beban Panas Heater (Q)


Q= 1,586,698.0562
1,503,899.5824

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T)
Suhu Tinggi 136.1291
Suhu Rendah 87.5291
Selisih

Dt= LMTD= 3.5777

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2=
tc = tavg = (t1+t2)/2=

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 2,802.3200

Karena A > 200 ft2, maka digunakan Shell and Tube Heat Exchanger

4. Menentukan Spesifikasi Shell and Tube


Tube Side
Panjang tube (L)= 18.0000
Outside Diameter (OD)= 0.7500
BWG= 18.0000
Inside Diameter (ID)= 0.6520
Tube surface area (a")= 0.1963
Number of passes (n)= 4.0000
Jumlah tube (Nt)= 793.0945
882.0000

Tube pitch (PT)= 1.0000

Koreksi Nilai Ud
A= Nt x L x a"= 3,116.4588
UD= 134.8800
(Setelah dikoreksi, nilai UD yang digunakan tidak berbeda jauh)

Shell Side
ID= 35.0000
Baffle Space (B)= ID
2
B= 17.5000
Pass (n)= 4.0000

5. Menghitung Flow Area on Both Sides


Tube Side
Flow area per tube (at')= 0.3340

at'= 10.4215
Shell Side
Clearance (C')= Tube Pitch - Tube Diameter= 0.2500
Luas area laluan (as)= 1.0634

6. Menghitung mass velocity (G) both sides


Tube Side (Gt)

Gt= 5,670.5131

Shell Side (Gs)

Gs= 26.1888

7. Menghitung Reynold Number (Re) both sides


Tube Side (Ret)

D= 0.6520
Pada Tc= 111.8291
μ pada Tc= 2.1225
Ret= 1,741.9130

Shell Side (Res)

D= 0.7300
Pada tc= 107.6000
μ pada tc= 2.1114
Res= 9.0547

8. Menghitung nilai Heat Transfer Factor (jH) both sides


Tube Side (Fig. 24, Kern)
jH= 3.0000

Shell Side (Fig. 28, Kern)


jH= 2.5000

9. Menghitung Prandtl Number (Pr) both sides


Tube Side (Prt)
Tc= 111.8291
c (cp) pada Tc= 0.5229
k pada Tc= 0.0386
µ pada Tc= 2.1225
Prt= 3.0626

Shell Side (Prs)

tc= 107.6000
c (cp) pada tc= 0.9934
k pada tc= 0.3627
µ pada tc= 2.1114
Prp= 1.7949

10. Menghitung nilai h (h) both sides


Tube Side (hi)
Untuk non-viscous fluid, maka φ = (µ/µw)0.14 = 1

(Persamaan 6.15a, Kern)


hi= 6.5331

Shell Side (ho)


Untuk non-viscous fluid, maka φ = (µ/µw)0.14 = 1

(Persamaan 6.15a, Kern)


ho= 26.7553

11. Menghitung nilai koreksi hi (hio) pada tube sides

ID= 0.6520
OD= 0.7500
hio= 5.6795
12. Menghitung clean overall coefficient (Uc)
Pers 6.7 Kern

Uc= 4.6850

13. Menghitung dirt factor (Rd)


Pers 6.11 Kern

Rd= -0.206034376189961

14. Menghitung Pressure Drop


Tube Side
Tube Pressure Drop (ΔPt)
Ret= 1,741.9130
f= 0.0001
s (spgr)= 0.0047

ΔPt= 0.0001

Kern 7.45

Return Loss Pressure Drop (ΔPr)


Gt= 5,670.5131
0.0500
=

ΔPr= 8.3733

ΔPT (total)= 8.3734


Accepted!
Shell Side
Ret= 9.0547
f= 0.0015
s (spgr)= 0.0187

N + 1= 12.3429
Number of cross= 13.0000
dimana,
N (jumlah baffle)= 12.0000
N + 1 (crosses dalam shell)= 13.0000

Sehingga,
ΔPs=
0.0000007

(Kern, eq 7.44)
Accepted!

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Bahan Konstruksi
Rd calculated
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Tube Side Transfer Coefficient (hio)
Shell Side Heat Transfer Coefficient (ho)
TUBE SIDE
Length 18.0000
OD 0.7500
BWG 18.0000
Pitch 1.0000
Passes 4.0000
Jumlah Tubes 882.00
ΔPT 8.3734
COOLER-02
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Shell and Tube Heat Exchanger

Tube
Kg/Jam 59,095.5279 lb/Jam
o
C 136.1291 F
o
C 87.5291 F

Shell
Kg/Jam 27.8484 lb/Jam
o
C 80.6000 F
o
C 134.6000 F

Kj/Jam
Btu/Jam

ence) Sumber: Process Heat Trans


Fluida Dingin (t) Selisih
134.6000 1.5291 T2-t2
80.6000 6.9291 T1-t1
-5.4000

dan tc)
111.8291 F
107.6000 F

Sumber: Process Heat Transfer by Kern H


a (A)
uku Kern

Btu/Jam ft2 F
Hal: 89

ft2

Heat Exchanger

ube Table 10, Kern

ft 216.0000 inch
inch

in
ft2/ft (outside)
(fig. 12.20 Coulson)

dari kern tabel 9

Tube pitch triangular arrangement, tabel 9 kern)

ft2
Btu/Jam ft2 F

inch 2.9167 ft

inch

des

in2 Table 10, Kern

ft2
Kern Hal. 138
in
ft2

ides

lb/ft2hr

lb/ft2hr

h sides

in 0.0543 ft
F
lb/ft jam

in (dari grafik) 0.0608 ft


F
lb/ft jam

both sides

sides
F
Btu/lb F
Btu/ft F
lb/ft hr

F
Btu/lb F
Btu/ft F
lb/ft hr

Btu/hr ft2 F

Btu/hr ft2 F

ube sides

in 0.0543 ft
in 0.0625 ft
Btu/hr ft2 F
(Uc)

Btu/hr ft2 F

Btu/hr ft2 F ρ ref (kg/m3)=

ft2/in2 (Fig 2.6 Kern)

psi

lb/ft2 hr
Fig 2.7 Kern

psi

psi
ft2/in2 (Fig 2.9 Kern)

12 adalah faktor konversi ft ke in

Baffle
Crosses

psi

SUMMARY
IDENTIFIKASI
Cooler
C-02
1 buah
Kontinyu
Mengkondensasikan top product KD-01
DATA DESAIN
Shell and Tube Heat Exchanger
Carbon Steel
0.2060 hr ft2 F/Btu
4.6850 Btu/hr ft2 F
134.8800 Btu/hr ft2 F
5.6795 Btu/hr ft2 F
o) 26.7553 Btu/hr ft2 F
SHELL SIDE
ft. ID 35.00 in.
in. Baffle Space 17.50 in.
in. Passes 4
in. (Triangular) ΔPS 6.58E-07 psi

tube
psi
1.0000 kg 1.0000 m^3 1.0000 cP 1.0000 mmHg
2.2046 lb 35.3100 ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000
2.7792 lbf/ft^2 144.0000

Sumber: Process Heat Transfer by Kern Hal: 89

rocess Heat Transfer by Kern Hal: 840 Tabel. 8


Kern Hal. 128
(Felder, pp. 44)
1000
psi
lbf/ft^2
ALIRAN 22
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.1909 6.1160 0.0003
Etil Asetat 88.107 607.8688 53,557.5000 0.9992
Air 18.025 0.2839 5.1174 0.0005
Total 608.3436 53,568.7334 1.0000

Kondisi Operasi
Tc= 198.3612912 F
365.5729396 K
92.42293958 oC
tw= F
K
C o

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Etil Asetat -3.6861 5.52E+02 0.008 -1.04E-05
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol.


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Etil Asetat 62.832 0.8410 -2.6998E-03 3.6631E-06
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.12243561678754
Etil Asetat -1.6938 1.0862 523.3 -1.58799744698806
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Etil Asetat 0.3065 0.2586 0.278 523.3
Air 0.3471 0.274 0.28571 647.13

Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol.


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 22)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.5823 0.2616 0.0003 0.0001


-0.6459 0.2260 0.9992 0.2258
-0.3362 0.4611 0.0005 0.0002
0.2261

A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
87.4358537844028 0.0003 0.0274339834235415 0.000856188234927331
188.423104358362 0.9992 188.276050395516 2.13690229375096
75.3675291130302 0.0005 0.0351728378236968 0.00195133635637708
188.338657216763 2.13970981834227

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0754335216114102 0.0003 2.36681165894436E-05 1.36801713886984E-05
0.0258227537056607 0.9992 0.0258026004538769 0.0149139030623409
0.669957275750823 0.0005 0.00031265850010088 0.000180716613058308
0.0261389270705672 0.0151082998467879
T= 365.572939579367
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.719825899003632 0.0003 0.00022585347916651 0.225853479166509
0.807739852734979 0.9992 0.807109455806227 807.109455806227
0.96321334688876 0.0005 0.00044951648592499 0.449516485924988
0.807784825771319 807.784825771319

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.059068484217204 0.872833719742336 1 0.872833719742336

A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2385029680882 1 75.2385029680882 4.17411944344456

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi
2.7792 lbf/ft^2

μ mix (lb/ft jam)

0.0002
0.5463
0.0005
0.5470

Cp mix (Btu/lb F)
0.00020377279991271
0.508582745912729
0.00046441805281774
0.509250936765459
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
0.014101290857278 0.7872443337914 0.0003 0.000247006772036158
50.3923394582387 0.8933861085041 0.9992 0.892688869340954
0.0280658183197459 1.0274529145287 0.0005 0.000479496079538504
50.4345065674157 0.893415372192528

μ mix (lb/ft jam)

2.11138476805671

Cp mix (Btu/lb F)
0.993440427539805
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
63.1708900628998 1.0274529145287 1 1.02745291452869
1 psi
144 lbf/ft^2
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
0.247006772036158 0.0154220087689299
892.688869340954 55.7355389790163
0.479496079538504 0.0299376113551568
893.415372192528 55.7808985991404
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
1027.45291452869 64.1496090447448
COOL
Fungsi: Mendingink
Tipe:
Gambar:

Fluida Panas: Aliran 22


Flow Rate (W1): 53,568.7334
T1: 114.9229
T2: 69.9229

Fluida Dingin: Cooling Water


Flow Rate (W2): 41.0950
t1: 27.0000
t2: 57.0000

1. Beban Panas Heater (Q)


Q= 5,161,941.5683
4,892,576.5925

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T)
Suhu Tinggi 238.8613
Suhu Rendah 157.8613
Selisih

Dt= LMTD= 90.1892

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2=
tc = tavg = (t1+t2)/2=

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 361.6528

Karena A > 200 ft2, maka digunakan Shell and Tube Heat Exchanger

4. Menentukan Spesifikasi Shell and Tube


Tube Side
Panjang tube (L)= 16.0000
Outside Diameter (OD)= 0.7500
BWG= 18.0000
Inside Diameter (ID)= 0.6520
Tube surface area (a")= 0.1963
Number of passes (n)= 6.0000
Jumlah tube (Nt)= 115.1467
118.0000

Tube pitch (PT)= 1.0000

Koreksi Nilai Ud
A= Nt x L x a"= 370.6144
UD= 146.3729
(Setelah dikoreksi, nilai UD yang digunakan tidak berbeda jauh)

Shell Side
ID= 15.2500
Baffle Space (B)= ID
2
B= 7.6250
Pass (n)= 6.0000

5. Menghitung Flow Area on Both Sides


Tube Side
Flow area per tube (at')= 0.3340

at'= 1.3943
Shell Side
Clearance (C')= Tube Pitch - Tube Diameter= 0.2500
Luas area laluan (as)= 0.2019

6. Menghitung mass velocity (G) both sides


Tube Side (Gt)

Gt= 84,702.3576

Shell Side (Gs)

Gs= 448.7779

7. Menghitung Reynold Number (Re) both sides


Tube Side (Ret)

D= 0.6520
Pada Tc= 198.3613
μ pada Tc= 0.5470
Ret= 100,965.3049

Shell Side (Res)

D= 0.7300
Pada tc= 107.6000
μ pada tc= 2.1114
Res= 155.1626

8. Menghitung nilai Heat Transfer Factor (jH) both sides


Tube Side (Fig. 24, Kern)
jH= 30.0000

Shell Side (Fig. 28, Kern)


jH= 2.5000

9. Menghitung Prandtl Number (Pr) both sides


Tube Side (Prt)
Tc= 198.3613
c (cp) pada Tc= 0.5093
k pada Tc= 0.0151
µ pada Tc= 0.5470
Prt= 2.6418

Shell Side (Prs)

tc= 107.6000
c (cp) pada tc= 0.9934
k pada tc= 0.3627
µ pada tc= 2.1114
Prp= 1.7949

10. Menghitung nilai h (h) both sides


Tube Side (hi)
Untuk non-viscous fluid, maka φ = (µ/µw)0.14 = 1

(Persamaan 6.15a, Kern)


hi= 22.0377

Shell Side (ho)


Untuk non-viscous fluid, maka φ = (µ/µw)0.14 = 1

(Persamaan 6.15a, Kern)


ho= 26.7553

11. Menghitung nilai koreksi hi (hio) pada tube sides

ID= 0.6520
OD= 0.7500
hio= 19.1581
12. Menghitung clean overall coefficient (Uc)
Pers 6.7 Kern

Uc= 11.1641

13. Menghitung dirt factor (Rd)


Pers 6.11 Kern

Rd= -0.082741106891185

14. Menghitung Pressure Drop


Tube Side
Tube Pressure Drop (ΔPt)
Ret= 100,965.3049
f= 0.0003
s (spgr)= 0.8078

ΔPt= 0.0002

Kern 7.45

Return Loss Pressure Drop (ΔPr)


Gt= 84,702.3576
0.0500
=

ΔPr= 0.0486

ΔPT (total)= 0.0488


Accepted!
Shell Side
Ret= 155.1626
f= 0.0150
s (spgr)= 1.0118

N + 1= 25.1803
Number of cross= 26.0000
dimana,
N (jumlah baffle)= 25.0000
N + 1 (crosses dalam shell)= 26.0000

Sehingga,
ΔPs=
3.11E-05

(Kern, eq 7.44)
Accepted!

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Bahan Konstruksi
Rd calculated
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Tube Side Transfer Coefficient (hio)
Shell Side Heat Transfer Coefficient (ho)
TUBE SIDE
Length 16.0000
OD 0.7500
BWG 18.0000
Pitch 1.0000
Passes 6.0000
Jumlah Tubes 118.00
ΔPT 0.0488
COOLER-03
Mendinginkan aliran 22 sebelum masuk ke tangki produk
Shell and Tube Heat Exchanger

Tube
Kg/Jam 118,097.6296 lb/Jam
o
C 238.8613 F
o
C 157.8613 F

Shell
Kg/Jam 90.5980 lb/Jam
o
C 80.6000 F
o
C 134.6000 F

Kj/Jam
Btu/Jam

ence) Sumber: Process Heat Trans


Fluida Dingin (t) Selisih
134.6000 104.2613 T2-t2
80.6000 77.2613 T1-t1
27.0000

dan tc)
198.3613 F
107.6000 F

Sumber: Process Heat Transfer by Kern H


a (A)
uku Kern

Btu/Jam ft2 F
Hal: 89

ft2

Heat Exchanger

ube Table 10, Kern

ft 192.0000 inch
inch

in
ft2/ft (outside)
(fig. 12.20 Coulson)

dari kern tabel 9

Tube pitch triangular arrangement, tabel 9 kern)

ft2
Btu/Jam ft2 F

inch 1.2708 ft

inch

des

in2 Table 10, Kern

ft2
Kern Hal. 138
in
ft2

ides

lb/ft2hr

lb/ft2hr

h sides

in 0.0543 ft
F
lb/ft jam

in (dari grafik) 0.0608 ft


F
lb/ft jam

both sides

sides
F
Btu/lb F
Btu/ft F
lb/ft hr

F
Btu/lb F
Btu/ft F
lb/ft hr

Btu/hr ft2 F

Btu/hr ft2 F

ube sides

in 0.0543 ft
in 0.0625 ft
Btu/hr ft2 F
(Uc)

Btu/hr ft2 F

Btu/hr ft2 F ρ ref (kg/m3)=

ft2/in2 (Fig 2.6 Kern)

psi

lb/ft2 hr
Fig 2.7 Kern

psi

psi
ft2/in2 (Fig 2.9 Kern)

12 adalah faktor konversi ft ke in

Baffle
Crosses

psi

SUMMARY
IDENTIFIKASI
Cooler
C-02
1 buah
Kontinyu
Mengkondensasikan top product KD-01
DATA DESAIN
Shell and Tube Heat Exchanger
Carbon Steel
0.0827 hr ft2 F/Btu
11.1641 Btu/hr ft2 F
146.3729 Btu/hr ft2 F
19.1581 Btu/hr ft2 F
o) 26.7553 Btu/hr ft2 F
SHELL SIDE
ft. ID 15.25 in.
in. Baffle Space 7.63 in.
in. Passes 6
in. (Triangular) ΔPS 3.11E-05 psi

tube
psi
1.0000 kg 1.0000 m^3 1.0000 cP 1.0000 mmHg
2.2046 lb 35.3100 ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000
2.7792 lbf/ft^2 144.0000

Sumber: Process Heat Transfer by Kern Hal: 89

rocess Heat Transfer by Kern Hal: 840 Tabel. 8


Kern Hal. 128
(Felder, pp. 44)
1000
psi
lbf/ft^2
ALIRAN 22
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.1909 6.1160 0.0003
Etil Asetat 88.107 607.8688 53,557.5000 0.9992
Air 18.025 0.2839 5.1174 0.0005
Total 608.3436 53,568.7334 1.0000

Kondisi Operasi
Tc= 121.8612912 F
323.0729396 K
49.92293958 oC
tw= F
K
C o

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Etil Asetat -3.6861 5.52E+02 0.008 -1.04E-05
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol.


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Etil Asetat 62.832 0.8410 -2.6998E-03 3.6631E-06
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.1029290653404
Etil Asetat -1.6938 1.0862 523.3 -1.55398292946675
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Etil Asetat 0.3065 0.2586 0.278 523.3
Air 0.3471 0.274 0.28571 647.13

Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol.


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 22)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.3941 0.4036 0.0003 0.0001


-0.4816 0.3299 0.9992 0.3296
-0.1150 0.7673 0.0005 0.0004
0.3301

A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
82.2658189881309 0.0003 0.0258118268051617 0.000805562287159408
176.255755800636 0.9992 176.118197790151 1.99891266063027
75.1491089882296 0.0005 0.0350709045943943 0.00194568125350315
176.179080521551 2.00166390417093

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0788988975102024 0.0003 2.47554172887451E-05 1.43086311928947E-05
0.0279265360811524 0.9992 0.0279047409418923 0.0161289402644138
0.636062607293869 0.0005 0.00029684039261143 0.000171573746929404
0.0282263367517925 0.0163148226425361
T= 323.072939579367
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.763844371006759 0.0003 0.00023966477029018 0.239664770290183
0.863239080641245 0.9992 0.862565369590128 862.565369590129
1.00435991260924 0.0005 0.00046871893955615 0.468718939556152
0.863273753299975 863.273753299975

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.059068484217204 0.872833719742336 1 0.872833719742336

A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2385029680882 1 75.2385029680882 4.17411944344456

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi
2.7792 lbf/ft^2

μ mix (lb/ft jam)

0.0003
0.7974
0.0009
0.7985

Cp mix (Btu/lb F)
0.00019172382434394
0.475741213230005
0.00046307213833375
0.476396009192682
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
0.0149636067001342 0.7872443337914 0.0003 0.000247006772036158
53.8547610818011 0.8933861085041 0.9992 0.892688869340954
0.0292647344702773 1.0274529145287 0.0005 0.000479496079538504
53.8989894229715 0.893415372192528

μ mix (lb/ft jam)

2.11138476805671

Cp mix (Btu/lb F)
0.993440427539805
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
63.1708900628998 1.0274529145287 1 1.02745291452869
1 psi
144 lbf/ft^2
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
0.247006772036158 0.0154220087689299
892.688869340954 55.7355389790163
0.479496079538504 0.0299376113551568
893.415372192528 55.7808985991404
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
1027.45291452869 64.1496090447448
COOL
Fungsi: Mendingink
Tipe:
Gambar:

Fluida Panas: Aliran 22


Flow Rate (W1): 53,568.7334
T1: 69.9229
T2: 29.9229

Fluida Dingin: Cooling Water


Flow Rate (W2): 35.1562
t1: 27.0000
t2: 57.0000

1. Beban Panas Heater (Q)


Q= 4,415,966.9678
4,185,529.0948

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T)
Suhu Tinggi 157.8613
Suhu Rendah 85.8613
Selisih

Dt= LMTD= 12.1233

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2=
tc = tavg = (t1+t2)/2=

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 2,301.6463

Karena A > 200 ft2, maka digunakan Shell and Tube Heat Exchanger

4. Menentukan Spesifikasi Shell and Tube


Tube Side
Panjang tube (L)= 16.0000
Outside Diameter (OD)= 0.7500
BWG= 18.0000
Inside Diameter (ID)= 0.6520
Tube surface area (a")= 0.1963
Number of passes (n)= 6.0000
Jumlah tube (Nt)= 732.8217
864.0000

Tube pitch (PT)= 1.0000

Koreksi Nilai Ud
A= Nt x L x a"= 2,713.6512
UD= 127.2260
(Setelah dikoreksi, nilai UD yang digunakan tidak berbeda jauh)

Shell Side
ID= 35.0000
Baffle Space (B)= ID
2
B= 17.5000
Pass (n)= 6.0000

5. Menghitung Flow Area on Both Sides


Tube Side
Flow area per tube (at')= 0.3340

at'= 10.2089
Shell Side
Clearance (C')= Tube Pitch - Tube Diameter= 0.2500
Luas area laluan (as)= 1.0634

6. Menghitung mass velocity (G) both sides


Tube Side (Gt)

Gt= 11,568.1461

Shell Side (Gs)

Gs= 72.8866

7. Menghitung Reynold Number (Re) both sides


Tube Side (Ret)

D= 0.6520
Pada Tc= 121.8613
μ pada Tc= 0.7985
Ret= 9,445.3070

Shell Side (Res)

D= 0.7300
Pada tc= 107.6000
μ pada tc= 2.1114
Res= 25.2002

8. Menghitung nilai Heat Transfer Factor (jH) both sides


Tube Side (Fig. 24, Kern)
jH= 30.0000

Shell Side (Fig. 28, Kern)


jH= 2.5000

9. Menghitung Prandtl Number (Pr) both sides


Tube Side (Prt)
Tc= 121.8613
c (cp) pada Tc= 0.4764
k pada Tc= 0.0163
µ pada Tc= 0.7985
Prt= 2.8569

Shell Side (Prs)

tc= 107.6000
c (cp) pada tc= 0.9934
k pada tc= 0.3627
µ pada tc= 2.1114
Prp= 1.7949

10. Menghitung nilai h (h) both sides


Tube Side (hi)
Untuk non-viscous fluid, maka φ = (µ/µw)0.14 = 1

(Persamaan 6.15a, Kern)


hi= 25.7354

Shell Side (ho)


Untuk non-viscous fluid, maka φ = (µ/µw)0.14 = 1

(Persamaan 6.15a, Kern)


ho= 26.7553

11. Menghitung nilai koreksi hi (hio) pada tube sides

ID= 0.6520
OD= 0.7500
hio= 22.3726
12. Menghitung clean overall coefficient (Uc)
Pers 6.7 Kern

Uc= 12.1842

13. Menghitung dirt factor (Rd)


Pers 6.11 Kern

Rd= -0.074213161449348

14. Menghitung Pressure Drop


Tube Side
Tube Pressure Drop (ΔPt)
Ret= 9,445.3070
f= 0.0003
s (spgr)= 0.8633

ΔPt= 0.0000

Kern 7.45

Return Loss Pressure Drop (ΔPr)


Gt= 11,568.1461
0.0500
=

ΔPr= 0.0455

ΔPT (total)= 0.0455


Accepted!
Shell Side
Ret= 25.2002
f= 0.0015
s (spgr)= 0.0187

N + 1= 10.9714
Number of cross= 11.0000
dimana,
N (jumlah baffle)= 10.0000
N + 1 (crosses dalam shell)= 11.0000

Sehingga,
ΔPs=
0.0000

(Kern, eq 7.44)
Accepted!

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Bahan Konstruksi
Rd calculated
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Tube Side Transfer Coefficient (hio)
Shell Side Heat Transfer Coefficient (ho)
TUBE SIDE
Length 16.0000
OD 0.7500
BWG 18.0000
Pitch 1.0000
Passes 6.0000
Jumlah Tubes 864.00
ΔPT 0.0455
COOLER-03
Mendinginkan aliran 22 sebelum masuk ke tangki produk
Shell and Tube Heat Exchanger

Tube
Kg/Jam 118,097.6296 lb/Jam
o
C 157.8613 F
o
C 85.8613 F

Shell
Kg/Jam 77.5053 lb/Jam
o
C 80.6000 F
o
C 134.6000 F

Kj/Jam
Btu/Jam

ence) Sumber: Process Heat Trans


Fluida Dingin (t) Selisih
134.6000 23.2613 T2-t2
80.6000 5.2613 T1-t1
18.0000

dan tc)
121.8613 F
107.6000 F

Sumber: Process Heat Transfer by Kern H


a (A)
uku Kern

Btu/Jam ft2 F
Hal: 89

ft2

Heat Exchanger

ube Table 10, Kern

ft 192.0000 inch
inch

in
ft2/ft (outside)
(fig. 12.20 Coulson)

dari kern tabel 9

Tube pitch triangular arrangement, tabel 9 kern)

ft2
Btu/Jam ft2 F

inch 2.9167 ft

inch

des

in2 Table 10, Kern

ft2
Kern Hal. 138
in
ft2

ides

lb/ft2hr

lb/ft2hr

h sides

in 0.0543 ft
F
lb/ft jam

in (dari grafik) 0.0608 ft


F
lb/ft jam

both sides

sides
F
Btu/lb F
Btu/ft F
lb/ft hr

F
Btu/lb F
Btu/ft F
lb/ft hr

Btu/hr ft2 F

Btu/hr ft2 F

ube sides

in 0.0543 ft
in 0.0625 ft
Btu/hr ft2 F
(Uc)

Btu/hr ft2 F

Btu/hr ft2 F ρ ref (kg/m3)=

ft2/in2 (Fig 2.6 Kern)

psi

lb/ft2 hr
Fig 2.7 Kern

psi

psi
ft2/in2 (Fig 2.9 Kern)

12 adalah faktor konversi ft ke in

Baffle
Crosses

psi

SUMMARY
IDENTIFIKASI
Cooler
C-02
1 buah
Kontinyu
Mengkondensasikan top product KD-01
DATA DESAIN
Shell and Tube Heat Exchanger
Carbon Steel
0.0742 hr ft2 F/Btu
12.1842 Btu/hr ft2 F
127.2260 Btu/hr ft2 F
22.3726 Btu/hr ft2 F
o) 26.7553 Btu/hr ft2 F
SHELL SIDE
ft. ID 35.00 in.
in. Baffle Space 17.50 in.
in. Passes 6
in. (Triangular) ΔPS 4.32E-06 psi

tube
psi
1.0000 kg 1.0000 m^3 1.0000 cP 1.0000 mmHg
2.2046 lb 35.3100 ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000
2.7792 lbf/ft^2 144.0000

Sumber: Process Heat Transfer by Kern Hal: 89

rocess Heat Transfer by Kern Hal: 840 Tabel. 8


Kern Hal. 128
(Felder, pp. 44)
1000
psi
lbf/ft^2
ALIRAN 14
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 38.6807 1,239.4081 0.9999
Air 18.025 0.0040 0.0725 0.0001
Total 38.6848 1,239.4805 1.0000

Kondisi Operasi
Tc= 184.0706279 F
357.6336822 K
84.48368219 oC
P= 4 Atm
bar
t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.11891957749036
Air -0.2758 0.004612 -0.0000055391 0
Total

Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Air 0.3471 0.274 0.28571 647.13

FL

Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 14)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.548818902905423 0.28260581714019 0.9999 0.282576451875978


-0.303414344694332 0.49726243844381 0.0001 5.1670001117559E-05
1.0000 0.2826

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
86.3333443909846 0.9999 86.3243735867245 2.6941006674591
75.2311291766309 0.0001 0.00781718510812275 0.000433685720284202
1.0000 86.3322 2.6945

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0760467086947813 0.9999 0.0760388067636892 0.0439504303094124
0.665145401395263 0.0001 6.91145378705617E-05 3.99482028891846E-05
1.0000 0.0761 0.0440
T= 357.63368218563
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.728520894815173 0.9999 0.728445194998459 728.445194998459
0.971087184467231 0.0001 0.0001009046170141 0.100904617014098
0.728546099615473 728.546099615473

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.059068484217204 0.87283371974234 1 0.872833719742336

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2385029680882 1 75.2385029680882 4.17411944344456

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144

μ mix (lb/ft jam)

0.683552437088
0.0001249897327
0.6837

Cp mix (Btu/lb F)
0.6411959588553
0.0001032172014
0.6413
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
45.480891444169 0.7872443337914 0.9999 0.787162532085797 787.162532085797
0.0063000373455 1.0274529145287 0.0001 0.000106761518943755 0.106761518943755
45.487191481514 0.787269293604741 787.269293604741

μ mix (lb/ft jam)

2.1113847680567

Cp mix (Btu/lb F)
0.9934404275398
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.1708900629 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
49.1469418928447
0.0066657163597678
49.1536076092045
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan
Tipe: Dou
Gambar:

Fluida Panas: Aliran 16 Shell (Annulus)


Flow Rate (W1): 1,239.4805 Kg/Jam
T1: 104.4837 oC
T2: 64.4837 oC

Fluida Dingin: Cooling water Tube (Inner Pipe)


Flow Rate (W2): 1.0644 Kg/Jam
t1: 27.0000 oC
t2: 57.0000 oC

1. Beban Panas Heater (Q)


Q= 133,700.3967 Kj/Jam
126,723.5249 Btu/Jam

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T) Fluida Dingin (t)
Suhu Tinggi 220.0706 134.6000
Suhu Rendah 148.0706 80.6000
Selisih

Dt= LMTD= 76.2018 F

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2= 184.0706
tc = tavg = (t1+t2)/2= 107.6000

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000 Btu/Jam ft2 F


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 11.0867 ft2

Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger

Menentukan Spesifikasi Shell (Annulus) dan Tube (Inner Pipe)

Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft

4. Menghitung flow area (a) both sides


Shell (annulus) (aa)

Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 6.6250 in
Maka, aa= 0.1080 ft2

Equivalent Diameter (DE)

De = 0.2491 ft

Tube (inner pipe) (ap) Sumber : Process Heat Tran

D= 6.0650 in
ap= 0.2005 ft2

5. Menghitung Mass Velocity (G)


Shell (annulus) (Ga)

Ga = 25,308.7890 lb/ft2 jam

Tube (inner pipe) (Gp)

Gp = 11.7023 lb/ft2 jam

6. Menghitung Reynold Number (Re)


Shell (annulus) (Rea)

Pada Tc, 184.0706 F


Nilai μ pada Tc = 0.6837 lb/ft jam
Maka, Nilai Rea = 9,222.4006

Tube (inner pipe) (Rep) Sumber : Process Heat Tran

Pada tc, 107.6000 F


Nilai μ pada tc = 2.1114 lb/ft jam
Maka, Nilai Rep = 2.8012

7. Menentukan nilai jH dari fig 14.

Shell (annulus)
jH= 50.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran

Pada Tc= 184.0706 F


Cp= 86.3322 kJ/Kmol.K
μ= 0.2826 cP
k (konduktivitas thermal)= 0.0761 W.m/K

Pr= 9.9668
Pr^(1/3) = 2.1520

Tube (inner pipe) (Prp) Sumber : Process Heat Tran


Pada tc= 107.6000 F
Cp= 75.2385 kJ/Kmol.K
μ= 0.8728 cP
k (konduktivitas thermal)= 0.6275 W.m/K

Pr= 5.7829
Pr^(1/3) = 1.7949

9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran

Ho = 19.0001 Btu/jam ft2 F

Tube (inner pipe) (hi) Sumber : Process Heat Tran

Hi = 1.9322 Btu/jam ft2 F

10. Konversi nilai hi menjadi hio pada inner pipe

OD = 6.6250 in
ID = 6.0650 in
Hio = 1.7689 Btu/hr ft2 F

11. Menghitung Clean Overall Coefficient (Uc)

Uc = 1.6182 Btu/hr ft2 F

12. Menghitung Design Overall Coefficient (Ud)

Sumber : Process Heat Transfer by


Sumber : Process Heat Transfer by

Pers. Umum

Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040

Maka,
Rd= 0.0040
1/Ud= 0.6220
Ud= 1.6078 Btu/hr ft2 F

13. Menghitung required surface area (A)

A= 1,034.3205 ft2

Next step 13.


Required length (L)= A/a" = 596.4939
dimana, A (surface area) dan a" (surface per pipe outside)
inner pippe

Panjang 1 hairpin= 40.0000 ft (20 @pipe)


Jumlah hairpin= 14.9123
15.0000 buah hairpin
Actual length (L)= 600.0000 ft
Actual surface= L x a"
1,040.4000 ft2
Ud actual= 1.5984 Btu/hr ft2 F
Rd actual= 0.0077 hr ft2 F/Btu

14. Menghitung Pressure Drop


Shell (annulus)
1)

D'e (Diameter equivalent)

D'e= D2-D1
D'e= 0.1130 ft

2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112

Rea= 4,183.1031

3) Friction factor (f)


Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0115

4) ΔFa (pressure drop, expressed in feet of liquid)

ρref = 49.1536 lbf/ft3


ρ= 45.4872 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0806
Δfa= 0.0901 ft

5) V (pressure drop on velocity head of the shell side/annulus)

V= 0.1546 ft/s

6)

g'= 32.2000 Kern pp.112


ft= Jumlah hairpins x (V^2/2g')= 0.0056 ft
ΔPa = 0.0773 psi
Allowable Pressure drop = 10 psi (Kern pp.112)

Tube (inner pipe)


1) Friction factor (f) (turbulent flow, commercial pipes)
Rep= 2.8012

Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.1748

2) ΔFp (pressure drop, expressed in feet of liquid)


Sumber : Process Heat Transfer by Kern Hal. 112

ρref = 64.1496 lbf/ft3


ρ= 63.1709 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0155
Δfp= 0.0000 ft

3) ΔPp

ΔPp= 1.49456924899E-08 psi


Allowable Pressure drop = 10 psi (Kern pp.112)

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 0.07728 psi
COOLER-04
Mendinginkan aliran 14 sebelum masuk ke MP-01
Double-Pipe Heat Exchanger

2,732.5588 lb/Jam 1.0000 kg 1.0000


220.0706 F 2.2046 lb 35.3100
148.0706 F

2.3466 lb/Jam
Return bend Gland
80.6000 F
134.6000 F

Return Head

Sumber: Process Heat Transfer by Kern Hal: 89


Selisih
85.4706 T2-t2
67.4706 T1-t1
18.0000

F
F

Sumber: Process Heat Transfer by Kern Hal: 840 Tabel. 8


Tube (Inner Pipe ) Sumber : Process Heat Transfer by Kern Tabel 11. Hal. 8
Nominal Pipe Size, IPS 6.0000 in
Schedule. No. 40.0000
OD 6.6250 in
ID 6.0650 in
a" (surface per pipe) outside 1.7340 ft2/ft
a" (surface per pipe) inside 1.5900 ft2/ft

Sumber : Process Heat Transfer by Kern Hal. 111

0.6651 ft 0.4423 ft2


0.5521 ft 0.3048 ft2

mber : Process Heat Transfer by Kern Hal. 111

0.505416666666667 ft
Sumber : Process Heat Transfer by Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 111

Sumber : Process Heat Transfer by Kern Hal. 112

mber : Process Heat Transfer by Kern Hal. 111

Sumber: Process Heat Transfer by Kern Hal: 834


mber : Process Heat Transfer by Kern Hal. 112

0.6413 Btu/lb F
0.6837 lb/ft jam
0.0440 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 111


0.9934 Btu/lb F
2.1114 lb/ft jam
0.3627 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 112

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

mber : Process Heat Transfer by Kern Hal. 111

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

Sumber : Process Heat Transfer by Kern Hal. 111

0.5521 ft
0.5054 ft

Sumber : Process Heat Transfer by Kern Hal. 112

rocess Heat Transfer by Kern Hal. 106


rocess Heat Transfer by Kern Hal. 106

Sumber : Process Heat Transfer by


Kern Hal. 107

Sumber : Process Heat Transfer by Kern Hal. 114

Sumber : Process Heat Transfer by Kern Hal. 103

ft

20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 112


Accepted!

Accepted!
Cooler
C-04
1 buah
Kontinyu
Mendinginkan aliran 14 sebelum masuk ke MP-01

Double Pipe Heat Exchanger


15.0000 buah
Stainlees Steel
0.0077 hr ft2 F/Btu
1.6182 Btu/hr ft2 F
1.6078 Btu/hr ft2 F
19.0001 Btu/hr ft2 F
1.7689 Btu/hr ft2 F
INNER PIPE SIDE
IPS 6.0000 in
SN 40.0000
OD 6.6250 in
ID 6.0650 in
a" 1.7340 ft2/ft
ΔPp 0.0000 psi
m^3 1.0000 cP 1.0000 mmHg
ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000 psi
2.7792 lbf/ft^2 144.0000 lbf/ft^2

Gland
Gland

Tee

Kern Hal: 89

40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 14
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 38.6807 1,239.4081 0.9999
Air 18.025 0.0040 0.0725 0.0001
Total 38.6848 1,239.4805 1.0000

Kondisi Operasi
Tc= 116.5706279 F
320.1336822 K
46.98368219 oC
P= 4 Atm
bar
t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Metanol -9.0562 1254.2 0.0224 -0.000023538
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Metanol 40.152 0.31046 -0.0010291 0.0000014598
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Metanol -1.1793 0.6191 512.18 -1.10151370096507
Air -0.2758 0.004612 -0.0000055391 0
Total

Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Air 0.3471 0.274 0.28571 647.13

FL

Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co

t standar= 77 F
298.15 K
25 oC

Viskositas Liquid (cP) ; T = K


Komponen log 10 Vis = A + B/T + CT + DT2
A B C D
Air -10.2158 1792.5 0.01773 -0.0000112631
Total

HEAT CAPACITY (FASE LIQUID), Cp liq =A+B*T+C*(T^2)+D*(T^3), Cp (J/mol. K)


Komponen
A B C D
Air 92.053 -0.039953 -0.00021103 0.00000053469
Total

Konduktivitas Termal Liquid


Konduktivitas Termal (W.m/K) ; T = K
Komponen log10 k liq = A + B (1-T/C)2/7
A B C Log 10 k liq
Air -0.2758 0.004612 -0.0000055391 0
Total
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Air 0.3471 0.274 0.28571 647.13
FLUIDA PANAS (Aliran 14)

1 kg 1 m^3
2.2046 lb 35.31 ft^3

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.379772632859635 0.41708768514978 0.9999 0.417044346020398


-0.0949117024715991 0.80368950575711 0.0001 8.35105056207314E-05
1.0000 0.4171

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
81.9674995835066 0.9999 81.9589824294494 2.55786100834684
75.1778575135081 0.0001 0.00781164970733579 0.000433378624540127
1.0000 81.9668 2.5583

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0791564482240664 0.9999 0.0791482231633097 0.045747672988393
0.632978696694845 0.0001 6.57721304427652E-05 3.80162913959183E-05
1.0000 0.0792 0.0458
T= 320.13368218563
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.766684649895601 0.9999 0.766604984524452 766.604984524452
1.00712018016849 0.0001 0.00010464876655007 0.104648766550064
0.766709633291002 766.709633291002

FLUIDA DINGIN (Cooling Water

Log 10 Vis μ (cP) Fraksi Mol μ mix (cP)

-0.059068484217204 0.87283371974234 1 0.872833719742336

B*T+C*(T^2)+D*(T^3), Cp (J/mol. K), T (K)


Cp (kJ/kmol.K) Fraksi Mol Cp mix (kJ/kmol.K) Cp mix (kJ/kg.K)
75.2385029680882 1 75.2385029680882 4.17411944344456

k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144

μ mix (lb/ft jam)

1.0088302730234
0.0002020119131
1.0090

Cp mix (Btu/lb F)
0.6087709199865
0.0001031441126
0.6089
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
47.863419679485 0.7872443337914 0.9999 0.787162532085797 787.162532085797
0.0065338054584 1.0274529145287 0.0001 0.000106761518943755 0.106761518943755
47.869953484943 0.787269293604741 787.269293604741

μ mix (lb/ft jam)

2.1113847680567

Cp mix (Btu/lb F)
0.9934404275398
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.1708900629 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
49.1469418928447
0.0066657163597678
49.1536076092045
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan
Tipe: Dou
Gambar:

Fluida Panas: Aliran 16 Shell (Annulus)


Flow Rate (W1): 1,239.4805 Kg/Jam
T1: 64.4837 oC
T2: 29.4837 oC

Fluida Dingin: Cooling water Tube (Inner Pipe)


Flow Rate (W2): 0.8839 Kg/Jam
t1: 27.0000 oC
t2: 57.0000 oC

1. Beban Panas Heater (Q)


Q= 111,031.8235 Kj/Jam
105,237.8632 Btu/Jam

2. LMTD (Log Mean Temperature Difference)


Komponen Fluida Panas (T) Fluida Dingin (t)
Suhu Tinggi 148.0706 134.6000
Suhu Rendah 85.0706 80.6000
Selisih

Dt= LMTD= 8.1689 F

3. Menghitung Caloric Temperature (Tc dan tc)


Tc = Tavg = (T1+T2)/2= 116.5706
tc = tavg = (t1+t2)/2= 107.6000

Trial awal menghitung nilai surface area (A)


Menentukan nilai Ud berdasarkan Tabel 8, buku Kern

Asumsi Ud awal= 150.0000 Btu/Jam ft2 F


Sumber: Process Heat Transfer by Kern Hal: 89
Maka,
A= 85.8854 ft2

Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger

Menentukan Spesifikasi Shell (Annulus) dan Tube (Inner Pipe)

Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft

4. Menghitung flow area (a) both sides


Shell (annulus) (aa)

Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 6.6250 in
Maka, aa= 0.1080 ft2

Equivalent Diameter (DE)

De = 0.2491 ft

Tube (inner pipe) (ap) Sumber : Process Heat Tran

D= 6.0650 in
ap= 0.2005 ft2

5. Menghitung Mass Velocity (G)


Shell (annulus) (Ga)

Ga = 25,308.7890 lb/ft2 jam

Tube (inner pipe) (Gp)

Gp = 9.7182 lb/ft2 jam

6. Menghitung Reynold Number (Re)


Shell (annulus) (Rea)

Pada Tc, 116.5706 F


Nilai μ pada Tc = 1.0090 lb/ft jam
Maka, Nilai Rea = 6,248.7070

Tube (inner pipe) (Rep) Sumber : Process Heat Tran

Pada tc, 107.6000 F


Nilai μ pada tc = 2.1114 lb/ft jam
Maka, Nilai Rep = 2.3263

7. Menentukan nilai jH dari fig 14.

Shell (annulus)
jH= 50.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran

Pada Tc= 116.5706 F


Cp= 81.9668 kJ/Kmol.K
μ= 0.4171 cP
k (konduktivitas thermal)= 0.0792 W.m/K

Pr= 13.4185
Pr^(1/3) = 2.3763

Tube (inner pipe) (Prp) Sumber : Process Heat Tran


Pada tc= 107.6000 F
Cp= 75.2385 kJ/Kmol.K
μ= 0.8728 cP
k (konduktivitas thermal)= 0.6275 W.m/K

Pr= 5.7829
Pr^(1/3) = 1.7949

9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran

Ho = 21.8362 Btu/jam ft2 F

Tube (inner pipe) (hi) Sumber : Process Heat Tran

Hi = 1.9322 Btu/jam ft2 F

10. Konversi nilai hi menjadi hio pada inner pipe

OD = 6.6250 in
ID = 6.0650 in
Hio = 1.7689 Btu/hr ft2 F

11. Menghitung Clean Overall Coefficient (Uc)

Uc = 1.6363 Btu/hr ft2 F

12. Menghitung Design Overall Coefficient (Ud)

Sumber : Process Heat Transfer by


Sumber : Process Heat Transfer by

Pers. Umum

Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040

Maka,
Rd= 0.0040
1/Ud= 0.6151
Ud= 1.6257 Btu/hr ft2 F

13. Menghitung required surface area (A)

A= 7,924.5341 ft2

Next step 13.


Required length (L)= A/a" = 4,570.0889
dimana, A (surface area) dan a" (surface per pipe outside)
inner pippe

Panjang 1 hairpin= 40.0000 ft (20 @pipe)


Jumlah hairpin= 114.2522
115.0000 buah hairpin
Actual length (L)= 4,600.0000 ft
Actual surface= L x a"
7,976.4000 ft2
Ud actual= 1.6151 Btu/hr ft2 F
Rd actual= 0.0080 hr ft2 F/Btu

14. Menghitung Pressure Drop


Shell (annulus)
1)

D'e (Diameter equivalent)

D'e= D2-D1
D'e= 0.1130 ft

2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112

Rea= 2,834.2930

3) Friction factor (f)


Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.0129

4) ΔFa (pressure drop, expressed in feet of liquid)

ρref = 49.1536 lbf/ft3


ρ= 47.8700 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0268
Δfa= 0.7005 ft

5) V (pressure drop on velocity head of the shell side/annulus)

V= 0.1469 ft/s

6)

g'= 32.2000 Kern pp.112


ft= Jumlah hairpins x (V^2/2g')= 0.0385 ft
ΔPa = 0.2817 psi
Allowable Pressure drop = 10 psi (Kern pp.112)

Tube (inner pipe)


1) Friction factor (f) (turbulent flow, commercial pipes)
Rep= 2.3263

Sumber : Process Heat Transfer by Kern Hal. 53

f= 0.1887

2) ΔFp (pressure drop, expressed in feet of liquid)


Sumber : Process Heat Transfer by Kern Hal. 112

ρref = 64.1496 lbf/ft3


ρ= 63.1709 lbf/ft3
g = 4,18*(10^8) (sesuai Kern pp. 115)
s (spesific gravity)= ρ/ρref = 1.0155
Δfp= 0.0000 ft

3) ΔPp

ΔPp= 8.53073959322E-08 psi


Allowable Pressure drop = 10 psi (Kern pp.112)

SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 0.28169 psi
COOLER-04
Mendinginkan aliran 14 sebelum masuk ke MP-01
Double-Pipe Heat Exchanger

2,732.5588 lb/Jam 1.0000 kg 1.0000


148.0706 F 2.2046 lb 35.3100
85.0706 F

1.9487 lb/Jam
Return bend Gland
80.6000 F
134.6000 F

Return Head

Sumber: Process Heat Transfer by Kern Hal: 89


Selisih
13.4706 T2-t2
4.4706 T1-t1
9.0000

F
F

Sumber: Process Heat Transfer by Kern Hal: 840 Tabel. 8


Tube (Inner Pipe ) Sumber : Process Heat Transfer by Kern Tabel 11. Hal. 8
Nominal Pipe Size, IPS 6.0000 in
Schedule. No. 40.0000
OD 6.6250 in
ID 6.0650 in
a" (surface per pipe) outside 1.7340 ft2/ft
a" (surface per pipe) inside 1.5900 ft2/ft

Sumber : Process Heat Transfer by Kern Hal. 111

0.6651 ft 0.4423 ft2


0.5521 ft 0.3048 ft2

mber : Process Heat Transfer by Kern Hal. 111

0.505416666666667 ft
Sumber : Process Heat Transfer by Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 111

Sumber : Process Heat Transfer by Kern Hal. 112

mber : Process Heat Transfer by Kern Hal. 111

Sumber: Process Heat Transfer by Kern Hal: 834


mber : Process Heat Transfer by Kern Hal. 112

0.6089 Btu/lb F
1.0090 lb/ft jam
0.0458 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 111


0.9934 Btu/lb F
2.1114 lb/ft jam
0.3627 Btu/jam ft F

mber : Process Heat Transfer by Kern Hal. 112

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

mber : Process Heat Transfer by Kern Hal. 111

Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)

Sumber : Process Heat Transfer by Kern Hal. 111

0.5521 ft
0.5054 ft

Sumber : Process Heat Transfer by Kern Hal. 112

rocess Heat Transfer by Kern Hal. 106


rocess Heat Transfer by Kern Hal. 106

Sumber : Process Heat Transfer by


Kern Hal. 107

Sumber : Process Heat Transfer by Kern Hal. 114

Sumber : Process Heat Transfer by Kern Hal. 103

ft

20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112

Sumber : Process Heat Transfer by Kern Hal. 112


Accepted!

Accepted!
Cooler
C-04
1 buah
Kontinyu
Mendinginkan aliran 14 sebelum masuk ke MP-01

Double Pipe Heat Exchanger


115.0000 buah
Stainlees Steel
0.0080 hr ft2 F/Btu
1.6363 Btu/hr ft2 F
1.6257 Btu/hr ft2 F
21.8362 Btu/hr ft2 F
1.7689 Btu/hr ft2 F
INNER PIPE SIDE
IPS 6.0000 in
SN 40.0000
OD 6.6250 in
ID 6.0650 in
a" 1.7340 ft2/ft
ΔPp 0.0000 psi
m^3 1.0000 cP 1.0000 mmHg
ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000 psi
2.7792 lbf/ft^2 144.0000 lbf/ft^2

Gland
Gland

Tee

Kern Hal: 89

40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844

You might also like