Kondisi Operasi
Tc= 300.3932057 F
422.2573365 K
149.1073365 oC
P= 4 Atm
bar
t standar= 77 F
298.15 K
25 C
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13
FL
Kondisi Operasi
tc= 117.5 F
320.65 K
47.5 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0714372935316061 0.0002 1.5230946901539E-05 8.80348730908952E-06
0.0589949230055653 0.9961 0.058767649920498 0.0339677016540478
0.684022336486565 0.0036 0.00248930124798505 0.00143881612133536
1 0.0612721821153846 0.0354153212626923
T= 422.257336504689
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.648421332265263 0.0002 0.00013824811094205 0.138248110942051
0.899101642970962 0.9961 0.89563792789555 895.63792789555
0.903956174485785 0.0036 0.00328968677372344 3.28968677372344
0.899065862780216 899.065862780216
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.63352735413025 1 0.63352735413025 0.366178810687284
T= 320.65
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.00663604346522 1 1.00663604346522 1006.63604346522
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144
7.72989804E-05
0.6728974027842
0.0028332337881
0.6758
Cp mix (Btu/lb F)
0.000154664171
0.5884757702844
0.0037389959544
0.5924
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.0086315996993 0.7872443337914 0.0002 0.000167846177448052 0.167846177448052
55.919665132782 1.0429408715507 0.9961 1.03892302768643 1038.92302768643
0.2053934710096 1.0274529145287 0.0036 0.00373911740297734 3.73911740297734
56.133690203491 1.04282999126685 1042.82999126685
1.9281291094772
Cp mix (Btu/lb F)
0.9925679648032
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
62.849895820544 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.0104795718720469
64.8657521052816
0.23345392881914
65.1096856059728
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan
Tipe: Dou
Gambar:
Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger
Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft
Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 4.5000 in
Maka, aa= 0.2368 ft2
De = 0.8046 ft
D= 4.0260 in
ap= 0.0884 ft2
Shell (annulus)
jH= 300.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran
Pr= 11.3038
Pr^(1/3) = 2.2443
Pr= 5.2264
Pr^(1/3) = 1.7354
9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran
OD = 4.5000 in
ID = 4.0260 in
Hio = 2.5419 Btu/hr ft2 F
Pers. Umum
Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040
Maka,
Rd= 0.0040
1/Ud= 0.4312
Ud= 2.3194 Btu/hr ft2 F
A= 6,127.9565 ft2
D'e= D2-D1
D'e= 0.2901 ft
2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112
Rea= 107,123.4449
f= 0.0055
V= 1.2350 ft/s
6)
f= 0.0480
3) ΔPp
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 4.16901 psi
COOLER-01
Mendinginkan aliran 15 sebelum masuk ke EDC-01
Double-Pipe Heat Exchanger
35.2605 lb/Jam
Return bend Gland
80.6000 F
154.4000 F
Return Head
F
F
0.3355 ft
Sumber : Process Heat Transfer by Kern Hal. 112
0.5924 Btu/lb F
0.6758 lb/ft jam
0.0354 Btu/jam ft F
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
0.3750 ft
0.3355 ft
ft
20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112
Accepted!
Cooler
C-01
1 buah
Kontinyu
Mendinginkan aliran 15 sebelum masuk ke EDC-01
Gland
Gland
Tee
Kern Hal: 89
40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 26
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.0000 0.0000 0.0000
Asam Asetat 60.052 445.9260 26,778.7500 0.9967
Air 18.025 1.4871 26.8056 0.0033
Total 447.4132 26,805.5556 1.0000
Kondisi Operasi
Tc= 253.1291495 F
395.9995275 K
122.8495275 oC
P= 3 Atm
bar
t standar= 77 F
298.15 K
25 C
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13
FL
Kondisi Operasi
tc= 101.3 F
311.65 K
38.5 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.07321060004279 0.0000 0.00 0.00
0.060330484794228 0.9967 0.0601299552113548 0.0347551141121631
0.681932388070201 0.0033 0.00226664210960336 0.00131011913935074
1 0.0623965973209582 0.0360652332515138
T= 395.999527497491
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.683887091573007 0.0000 0.00 0.00
0.932794140505738 0.9967 0.929693671140373 929.693671140373
0.932122507656093 0.0033 0.00309823695739303 3.09823695739303
0.932791908097766 932.791908097766
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62354071050025 1 0.62354071050025 0.360406530669144
T= 311.65
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01503080894644 1 1.01503080894644 1015.03080894644
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144
0.00
0.8668373167711
0.0029569201987
0.87
Cp mix (Btu/lb F)
0.00
0.5679203971908
0.0033505004662
0.5713
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.00 0.7872443337914 0.0000 0.00 0.00
58.045954896519 1.0429408715507 0.9967 1.03947429078895 1039.47429078895
0.1934401924743 1.0274529145287 0.0033 0.0034151010898542 3.4151010898542
58.239395088993 1.04288939187881 1042.88939187881
2.2443889210733
Cp mix (Btu/lb F)
0.994118561952
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.37402779392 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.00
64.9001705316717
0.21322378540619
65.1133943170779
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan ali
Tipe: Dou
Gambar:
Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger
Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft
Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 4.5000 in
Maka, aa= 0.2368 ft2
De = 0.8046 ft
D= 4.0260 in
ap= 0.0884 ft2
Shell (annulus)
jH= 300.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran
Pr= 13.7775
Pr^(1/3) = 2.3973
Pr= 6.1908
Pr^(1/3) = 1.8362
9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran
OD = 4.5000 in
ID = 4.0260 in
Hio = 2.6471 Btu/hr ft2 F
Pers. Umum
Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040
Maka,
Rd= 0.0040
1/Ud= 0.4128
Ud= 2.4225 Btu/hr ft2 F
A= 11,906.4828 ft2
D'e= D2-D1
D'e= 0.2901 ft
2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112
Rea= 83,214.7469
f= 0.0058
V= 1.1901 ft/s
6)
f= 0.0337
3) ΔPp
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 7.62529 psi
COOLER-02
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Double-Pipe Heat Exchanger
103.0943 lb/Jam
Return bend Gland
80.6000 F
122.0000 F
Return Head
F
F
0.3355 ft
Sumber : Process Heat Transfer by Kern Hal. 112
0.5713 Btu/lb F
0.8698 lb/ft jam
0.0361 Btu/jam ft F
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
0.3750 ft
0.3355 ft
ft
20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112
Accepted!
Cooler
C-01
1 buah
Kontinyu
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Gland
Gland
Tee
Kern Hal: 89
40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 26
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.0000 0.0000 0.0000
Asam Asetat 60.052 445.9260 26,778.7500 0.9967
Air 18.025 1.4871 26.8056 0.0033
Total 447.4132 26,805.5556 1.0000
Kondisi Operasi
Tc= 163.1291495 F
345.9995275 K
72.8495275 oC
P= 3 Atm
bar
t standar= 77 F
298.15 K
25 C
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13
FL
Kondisi Operasi
tc= 101.3 F
311.65 K
38.5 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0769723862268872 0.0000 0.00 0.00
0.063154442485305 0.9967 0.0629445264859332 0.0363819363088694
0.656832736346336 0.0033 0.0021832145902056 0.00126189803313883
1 0.0651277410761388 0.0376438343420082
T= 345.999527497491
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.740841082497788 0.0000 0.00 0.00
0.991582650903198 0.9967 0.98828677724914 988.28677724914
0.982463515760517 0.0033 0.00326556300144891 3.26556300144891
0.991552340250589 991.552340250589
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62354071050025 1 0.62354071050025 0.360406530669144
T= 311.65
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01503080894644 1 1.01503080894644 1015.03080894644
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144
0.00
1.4785412443975
0.0045323395882
1.48
Cp mix (Btu/lb F)
0.00
0.5359598357486
0.0032965572486
0.5393
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.00 0.7872443337914 0.0000 0.00 0.00
61.704248913154 1.0429408715507 0.9967 1.03947429078895 1039.47429078895
0.2038872895212 1.0274529145287 0.0033 0.0034151010898542 3.4151010898542
61.908136202675 1.04288939187881 1042.88939187881
2.2443889210733
Cp mix (Btu/lb F)
0.994118561952
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.37402779392 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.00
64.9001705316717
0.21322378540619
65.1133943170779
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan ali
Tipe: Dou
Gambar:
Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger
Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft
Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 4.5000 in
Maka, aa= 0.2368 ft2
De = 0.8046 ft
D= 4.0260 in
ap= 0.0884 ft2
Shell (annulus)
jH= 300.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran
Pr= 21.2454
Pr^(1/3) = 2.7696
Pr= 6.1908
Pr^(1/3) = 1.8362
9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran
OD = 4.5000 in
ID = 4.0260 in
Hio = 2.6471 Btu/hr ft2 F
Pers. Umum
Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040
Maka,
Rd= 0.0040
1/Ud= 0.4075
Ud= 2.4540 Btu/hr ft2 F
A= 11,387.4810 ft2
D'e= D2-D1
D'e= 0.2901 ft
2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112
Rea= 48,803.8544
f= 0.0063
V= 1.1196 ft/s
6)
f= 0.0477
3) ΔPp
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 7.54426 psi
COOLER-02
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Double-Pipe Heat Exchanger
41.6340 lb/Jam
Return bend Gland
80.6000 F
122.0000 F
Return Head
F
F
0.3355 ft
Sumber : Process Heat Transfer by Kern Hal. 112
0.5393 Btu/lb F
1.4831 lb/ft jam
0.0376 Btu/jam ft F
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
0.3750 ft
0.3355 ft
ft
20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112
Accepted!
Cooler
C-01
1 buah
Kontinyu
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Gland
Gland
Tee
Kern Hal: 89
40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 26
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 0.0000 0.0000 0.0000
Asam Asetat 60.052 445.9260 26,778.7500 0.9967
Air 18.025 1.4871 26.8056 0.0033
Total 447.4132 26,805.5556 1.0000
Kondisi Operasi
Tc= 111.8291495 F
317.4995275 K
44.3495275 oC
P= 3 Atm
bar
t standar= 77 F
298.15 K
25 C
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Asam Asetat 0.35182 0.26954 0.26843 592.71
Air 0.3471 0.274 0.28571 647.13
FL
Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0793894244457544 0.0000 0.00 0.00
0.0649625365306728 0.9967 0.0647466106948817 0.0374235409816416
0.630133583388733 0.0033 0.0020944705659546 0.00121060398712176
1 0.0668410812608363 0.0386341449687634
T= 317.499527497491
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.769210797365482 0.0000 0.00 0.00
1.02265715339289 0.9967 1.01925799270172 1019.25799270172
1.00958529383225 0.0033 0.00335571176889296 3.35571176889296
1.02261370447061 1022.61370447061
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144
0.00
2.1157336669771
0.0067458134097
2.12
Cp mix (Btu/lb F)
0.00
0.5195944490739
0.0033007127802
0.5229
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
0.00 0.7872443337914 0.0000 0.00 0.00
63.637954423965 1.0429408715507 0.9967 1.03947429078895 1039.47429078895
0.2095157792609 1.0274529145287 0.0033 0.0034151010898542 3.4151010898542
63.847470203226 1.04288939187881 1042.88939187881
2.1113847680567
Cp mix (Btu/lb F)
0.9934404275398
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.1708900629 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
0.00
64.9001705316717
0.21322378540619
65.1133943170779
ρ standar mix (lb/ft3)
64.1496090447448
COOL
Fungsi: Mendingink
Tipe:
Gambar:
Karena A > 200 ft2, maka digunakan Shell and Tube Heat Exchanger
Koreksi Nilai Ud
A= Nt x L x a"= 3,116.4588
UD= 134.8800
(Setelah dikoreksi, nilai UD yang digunakan tidak berbeda jauh)
Shell Side
ID= 35.0000
Baffle Space (B)= ID
2
B= 17.5000
Pass (n)= 4.0000
at'= 10.4215
Shell Side
Clearance (C')= Tube Pitch - Tube Diameter= 0.2500
Luas area laluan (as)= 1.0634
Gt= 5,670.5131
Gs= 26.1888
D= 0.6520
Pada Tc= 111.8291
μ pada Tc= 2.1225
Ret= 1,741.9130
D= 0.7300
Pada tc= 107.6000
μ pada tc= 2.1114
Res= 9.0547
tc= 107.6000
c (cp) pada tc= 0.9934
k pada tc= 0.3627
µ pada tc= 2.1114
Prp= 1.7949
ID= 0.6520
OD= 0.7500
hio= 5.6795
12. Menghitung clean overall coefficient (Uc)
Pers 6.7 Kern
Uc= 4.6850
Rd= -0.206034376189961
ΔPt= 0.0001
Kern 7.45
ΔPr= 8.3733
N + 1= 12.3429
Number of cross= 13.0000
dimana,
N (jumlah baffle)= 12.0000
N + 1 (crosses dalam shell)= 13.0000
Sehingga,
ΔPs=
0.0000007
(Kern, eq 7.44)
Accepted!
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Bahan Konstruksi
Rd calculated
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Tube Side Transfer Coefficient (hio)
Shell Side Heat Transfer Coefficient (ho)
TUBE SIDE
Length 18.0000
OD 0.7500
BWG 18.0000
Pitch 1.0000
Passes 4.0000
Jumlah Tubes 882.00
ΔPT 8.3734
COOLER-02
Mendinginkan aliran 26 sebelum masuk ke tangki produk
Shell and Tube Heat Exchanger
Tube
Kg/Jam 59,095.5279 lb/Jam
o
C 136.1291 F
o
C 87.5291 F
Shell
Kg/Jam 27.8484 lb/Jam
o
C 80.6000 F
o
C 134.6000 F
Kj/Jam
Btu/Jam
dan tc)
111.8291 F
107.6000 F
Btu/Jam ft2 F
Hal: 89
ft2
Heat Exchanger
ft 216.0000 inch
inch
in
ft2/ft (outside)
(fig. 12.20 Coulson)
ft2
Btu/Jam ft2 F
inch 2.9167 ft
inch
des
ft2
Kern Hal. 138
in
ft2
ides
lb/ft2hr
lb/ft2hr
h sides
in 0.0543 ft
F
lb/ft jam
both sides
sides
F
Btu/lb F
Btu/ft F
lb/ft hr
F
Btu/lb F
Btu/ft F
lb/ft hr
Btu/hr ft2 F
Btu/hr ft2 F
ube sides
in 0.0543 ft
in 0.0625 ft
Btu/hr ft2 F
(Uc)
Btu/hr ft2 F
psi
lb/ft2 hr
Fig 2.7 Kern
psi
psi
ft2/in2 (Fig 2.9 Kern)
Baffle
Crosses
psi
SUMMARY
IDENTIFIKASI
Cooler
C-02
1 buah
Kontinyu
Mengkondensasikan top product KD-01
DATA DESAIN
Shell and Tube Heat Exchanger
Carbon Steel
0.2060 hr ft2 F/Btu
4.6850 Btu/hr ft2 F
134.8800 Btu/hr ft2 F
5.6795 Btu/hr ft2 F
o) 26.7553 Btu/hr ft2 F
SHELL SIDE
ft. ID 35.00 in.
in. Baffle Space 17.50 in.
in. Passes 4
in. (Triangular) ΔPS 6.58E-07 psi
tube
psi
1.0000 kg 1.0000 m^3 1.0000 cP 1.0000 mmHg
2.2046 lb 35.3100 ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000
2.7792 lbf/ft^2 144.0000
Kondisi Operasi
Tc= 198.3612912 F
365.5729396 K
92.42293958 oC
tw= F
K
C o
t standar= 77 F
298.15 K
25 oC
Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0754335216114102 0.0003 2.36681165894436E-05 1.36801713886984E-05
0.0258227537056607 0.9992 0.0258026004538769 0.0149139030623409
0.669957275750823 0.0005 0.00031265850010088 0.000180716613058308
0.0261389270705672 0.0151082998467879
T= 365.572939579367
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.719825899003632 0.0003 0.00022585347916651 0.225853479166509
0.807739852734979 0.9992 0.807109455806227 807.109455806227
0.96321334688876 0.0005 0.00044951648592499 0.449516485924988
0.807784825771319 807.784825771319
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi
2.7792 lbf/ft^2
0.0002
0.5463
0.0005
0.5470
Cp mix (Btu/lb F)
0.00020377279991271
0.508582745912729
0.00046441805281774
0.509250936765459
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
0.014101290857278 0.7872443337914 0.0003 0.000247006772036158
50.3923394582387 0.8933861085041 0.9992 0.892688869340954
0.0280658183197459 1.0274529145287 0.0005 0.000479496079538504
50.4345065674157 0.893415372192528
2.11138476805671
Cp mix (Btu/lb F)
0.993440427539805
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
63.1708900628998 1.0274529145287 1 1.02745291452869
1 psi
144 lbf/ft^2
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
0.247006772036158 0.0154220087689299
892.688869340954 55.7355389790163
0.479496079538504 0.0299376113551568
893.415372192528 55.7808985991404
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
1027.45291452869 64.1496090447448
COOL
Fungsi: Mendingink
Tipe:
Gambar:
Karena A > 200 ft2, maka digunakan Shell and Tube Heat Exchanger
Koreksi Nilai Ud
A= Nt x L x a"= 370.6144
UD= 146.3729
(Setelah dikoreksi, nilai UD yang digunakan tidak berbeda jauh)
Shell Side
ID= 15.2500
Baffle Space (B)= ID
2
B= 7.6250
Pass (n)= 6.0000
at'= 1.3943
Shell Side
Clearance (C')= Tube Pitch - Tube Diameter= 0.2500
Luas area laluan (as)= 0.2019
Gt= 84,702.3576
Gs= 448.7779
D= 0.6520
Pada Tc= 198.3613
μ pada Tc= 0.5470
Ret= 100,965.3049
D= 0.7300
Pada tc= 107.6000
μ pada tc= 2.1114
Res= 155.1626
tc= 107.6000
c (cp) pada tc= 0.9934
k pada tc= 0.3627
µ pada tc= 2.1114
Prp= 1.7949
ID= 0.6520
OD= 0.7500
hio= 19.1581
12. Menghitung clean overall coefficient (Uc)
Pers 6.7 Kern
Uc= 11.1641
Rd= -0.082741106891185
ΔPt= 0.0002
Kern 7.45
ΔPr= 0.0486
N + 1= 25.1803
Number of cross= 26.0000
dimana,
N (jumlah baffle)= 25.0000
N + 1 (crosses dalam shell)= 26.0000
Sehingga,
ΔPs=
3.11E-05
(Kern, eq 7.44)
Accepted!
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Bahan Konstruksi
Rd calculated
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Tube Side Transfer Coefficient (hio)
Shell Side Heat Transfer Coefficient (ho)
TUBE SIDE
Length 16.0000
OD 0.7500
BWG 18.0000
Pitch 1.0000
Passes 6.0000
Jumlah Tubes 118.00
ΔPT 0.0488
COOLER-03
Mendinginkan aliran 22 sebelum masuk ke tangki produk
Shell and Tube Heat Exchanger
Tube
Kg/Jam 118,097.6296 lb/Jam
o
C 238.8613 F
o
C 157.8613 F
Shell
Kg/Jam 90.5980 lb/Jam
o
C 80.6000 F
o
C 134.6000 F
Kj/Jam
Btu/Jam
dan tc)
198.3613 F
107.6000 F
Btu/Jam ft2 F
Hal: 89
ft2
Heat Exchanger
ft 192.0000 inch
inch
in
ft2/ft (outside)
(fig. 12.20 Coulson)
ft2
Btu/Jam ft2 F
inch 1.2708 ft
inch
des
ft2
Kern Hal. 138
in
ft2
ides
lb/ft2hr
lb/ft2hr
h sides
in 0.0543 ft
F
lb/ft jam
both sides
sides
F
Btu/lb F
Btu/ft F
lb/ft hr
F
Btu/lb F
Btu/ft F
lb/ft hr
Btu/hr ft2 F
Btu/hr ft2 F
ube sides
in 0.0543 ft
in 0.0625 ft
Btu/hr ft2 F
(Uc)
Btu/hr ft2 F
psi
lb/ft2 hr
Fig 2.7 Kern
psi
psi
ft2/in2 (Fig 2.9 Kern)
Baffle
Crosses
psi
SUMMARY
IDENTIFIKASI
Cooler
C-02
1 buah
Kontinyu
Mengkondensasikan top product KD-01
DATA DESAIN
Shell and Tube Heat Exchanger
Carbon Steel
0.0827 hr ft2 F/Btu
11.1641 Btu/hr ft2 F
146.3729 Btu/hr ft2 F
19.1581 Btu/hr ft2 F
o) 26.7553 Btu/hr ft2 F
SHELL SIDE
ft. ID 15.25 in.
in. Baffle Space 7.63 in.
in. Passes 6
in. (Triangular) ΔPS 3.11E-05 psi
tube
psi
1.0000 kg 1.0000 m^3 1.0000 cP 1.0000 mmHg
2.2046 lb 35.3100 ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000
2.7792 lbf/ft^2 144.0000
Kondisi Operasi
Tc= 121.8612912 F
323.0729396 K
49.92293958 oC
tw= F
K
C o
t standar= 77 F
298.15 K
25 oC
Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0788988975102024 0.0003 2.47554172887451E-05 1.43086311928947E-05
0.0279265360811524 0.9992 0.0279047409418923 0.0161289402644138
0.636062607293869 0.0005 0.00029684039261143 0.000171573746929404
0.0282263367517925 0.0163148226425361
T= 323.072939579367
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.763844371006759 0.0003 0.00023966477029018 0.239664770290183
0.863239080641245 0.9992 0.862565369590128 862.565369590129
1.00435991260924 0.0005 0.00046871893955615 0.468718939556152
0.863273753299975 863.273753299975
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi
2.7792 lbf/ft^2
0.0003
0.7974
0.0009
0.7985
Cp mix (Btu/lb F)
0.00019172382434394
0.475741213230005
0.00046307213833375
0.476396009192682
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
0.0149636067001342 0.7872443337914 0.0003 0.000247006772036158
53.8547610818011 0.8933861085041 0.9992 0.892688869340954
0.0292647344702773 1.0274529145287 0.0005 0.000479496079538504
53.8989894229715 0.893415372192528
2.11138476805671
Cp mix (Btu/lb F)
0.993440427539805
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3)
ρ Fraksi
63.1708900628998 1.0274529145287 1 1.02745291452869
1 psi
144 lbf/ft^2
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
0.247006772036158 0.0154220087689299
892.688869340954 55.7355389790163
0.479496079538504 0.0299376113551568
893.415372192528 55.7808985991404
ρ standra mix (kg/m3) ρ standar mix (lb/ft3)
1027.45291452869 64.1496090447448
COOL
Fungsi: Mendingink
Tipe:
Gambar:
Karena A > 200 ft2, maka digunakan Shell and Tube Heat Exchanger
Koreksi Nilai Ud
A= Nt x L x a"= 2,713.6512
UD= 127.2260
(Setelah dikoreksi, nilai UD yang digunakan tidak berbeda jauh)
Shell Side
ID= 35.0000
Baffle Space (B)= ID
2
B= 17.5000
Pass (n)= 6.0000
at'= 10.2089
Shell Side
Clearance (C')= Tube Pitch - Tube Diameter= 0.2500
Luas area laluan (as)= 1.0634
Gt= 11,568.1461
Gs= 72.8866
D= 0.6520
Pada Tc= 121.8613
μ pada Tc= 0.7985
Ret= 9,445.3070
D= 0.7300
Pada tc= 107.6000
μ pada tc= 2.1114
Res= 25.2002
tc= 107.6000
c (cp) pada tc= 0.9934
k pada tc= 0.3627
µ pada tc= 2.1114
Prp= 1.7949
ID= 0.6520
OD= 0.7500
hio= 22.3726
12. Menghitung clean overall coefficient (Uc)
Pers 6.7 Kern
Uc= 12.1842
Rd= -0.074213161449348
ΔPt= 0.0000
Kern 7.45
ΔPr= 0.0455
N + 1= 10.9714
Number of cross= 11.0000
dimana,
N (jumlah baffle)= 10.0000
N + 1 (crosses dalam shell)= 11.0000
Sehingga,
ΔPs=
0.0000
(Kern, eq 7.44)
Accepted!
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Bahan Konstruksi
Rd calculated
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Tube Side Transfer Coefficient (hio)
Shell Side Heat Transfer Coefficient (ho)
TUBE SIDE
Length 16.0000
OD 0.7500
BWG 18.0000
Pitch 1.0000
Passes 6.0000
Jumlah Tubes 864.00
ΔPT 0.0455
COOLER-03
Mendinginkan aliran 22 sebelum masuk ke tangki produk
Shell and Tube Heat Exchanger
Tube
Kg/Jam 118,097.6296 lb/Jam
o
C 157.8613 F
o
C 85.8613 F
Shell
Kg/Jam 77.5053 lb/Jam
o
C 80.6000 F
o
C 134.6000 F
Kj/Jam
Btu/Jam
dan tc)
121.8613 F
107.6000 F
Btu/Jam ft2 F
Hal: 89
ft2
Heat Exchanger
ft 192.0000 inch
inch
in
ft2/ft (outside)
(fig. 12.20 Coulson)
ft2
Btu/Jam ft2 F
inch 2.9167 ft
inch
des
ft2
Kern Hal. 138
in
ft2
ides
lb/ft2hr
lb/ft2hr
h sides
in 0.0543 ft
F
lb/ft jam
both sides
sides
F
Btu/lb F
Btu/ft F
lb/ft hr
F
Btu/lb F
Btu/ft F
lb/ft hr
Btu/hr ft2 F
Btu/hr ft2 F
ube sides
in 0.0543 ft
in 0.0625 ft
Btu/hr ft2 F
(Uc)
Btu/hr ft2 F
psi
lb/ft2 hr
Fig 2.7 Kern
psi
psi
ft2/in2 (Fig 2.9 Kern)
Baffle
Crosses
psi
SUMMARY
IDENTIFIKASI
Cooler
C-02
1 buah
Kontinyu
Mengkondensasikan top product KD-01
DATA DESAIN
Shell and Tube Heat Exchanger
Carbon Steel
0.0742 hr ft2 F/Btu
12.1842 Btu/hr ft2 F
127.2260 Btu/hr ft2 F
22.3726 Btu/hr ft2 F
o) 26.7553 Btu/hr ft2 F
SHELL SIDE
ft. ID 35.00 in.
in. Baffle Space 17.50 in.
in. Passes 6
in. (Triangular) ΔPS 4.32E-06 psi
tube
psi
1.0000 kg 1.0000 m^3 1.0000 cP 1.0000 mmHg
2.2046 lb 35.3100 ft^3 2.4191 lb/ft hr 0.0193 psi 1.0000
2.7792 lbf/ft^2 144.0000
Kondisi Operasi
Tc= 184.0706279 F
357.6336822 K
84.48368219 oC
P= 4 Atm
bar
t standar= 77 F
298.15 K
25 oC
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Air 0.3471 0.274 0.28571 647.13
FL
Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0760467086947813 0.9999 0.0760388067636892 0.0439504303094124
0.665145401395263 0.0001 6.91145378705617E-05 3.99482028891846E-05
1.0000 0.0761 0.0440
T= 357.63368218563
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.728520894815173 0.9999 0.728445194998459 728.445194998459
0.971087184467231 0.0001 0.0001009046170141 0.100904617014098
0.728546099615473 728.546099615473
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144
0.683552437088
0.0001249897327
0.6837
Cp mix (Btu/lb F)
0.6411959588553
0.0001032172014
0.6413
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
45.480891444169 0.7872443337914 0.9999 0.787162532085797 787.162532085797
0.0063000373455 1.0274529145287 0.0001 0.000106761518943755 0.106761518943755
45.487191481514 0.787269293604741 787.269293604741
2.1113847680567
Cp mix (Btu/lb F)
0.9934404275398
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.1708900629 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
49.1469418928447
0.0066657163597678
49.1536076092045
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan
Tipe: Dou
Gambar:
Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger
Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft
Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 6.6250 in
Maka, aa= 0.1080 ft2
De = 0.2491 ft
D= 6.0650 in
ap= 0.2005 ft2
Shell (annulus)
jH= 50.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran
Pr= 9.9668
Pr^(1/3) = 2.1520
Pr= 5.7829
Pr^(1/3) = 1.7949
9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran
OD = 6.6250 in
ID = 6.0650 in
Hio = 1.7689 Btu/hr ft2 F
Pers. Umum
Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040
Maka,
Rd= 0.0040
1/Ud= 0.6220
Ud= 1.6078 Btu/hr ft2 F
A= 1,034.3205 ft2
D'e= D2-D1
D'e= 0.1130 ft
2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112
Rea= 4,183.1031
f= 0.0115
V= 0.1546 ft/s
6)
f= 0.1748
3) ΔPp
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 0.07728 psi
COOLER-04
Mendinginkan aliran 14 sebelum masuk ke MP-01
Double-Pipe Heat Exchanger
2.3466 lb/Jam
Return bend Gland
80.6000 F
134.6000 F
Return Head
F
F
0.505416666666667 ft
Sumber : Process Heat Transfer by Kern Hal. 112
0.6413 Btu/lb F
0.6837 lb/ft jam
0.0440 Btu/jam ft F
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
0.5521 ft
0.5054 ft
ft
20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112
Accepted!
Cooler
C-04
1 buah
Kontinyu
Mendinginkan aliran 14 sebelum masuk ke MP-01
Gland
Gland
Tee
Kern Hal: 89
40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844
ALIRAN 14
Komponen BM Kmol/Jam Kg/Jam Fraksi Mol
Metanol 32.042 38.6807 1,239.4081 0.9999
Air 18.025 0.0040 0.0725 0.0001
Total 38.6848 1,239.4805 1.0000
Kondisi Operasi
Tc= 116.5706279 F
320.1336822 K
46.98368219 oC
P= 4 Atm
bar
t standar= 77 F
298.15 K
25 oC
Densitas Liquid
Densitas Liquid (g/cm3) ; T = K
Komponen ρ = A(B-(1-T/Tc)^n)
A B n Tc
Metanol 0.27197 0.27192 0.2331 512.58
Air 0.3471 0.274 0.28571 647.13
FL
Kondisi Operasi
tc= 107.6 F
315.15 K
42 oC
tw= F
K
Co
t standar= 77 F
298.15 K
25 oC
1 kg 1 m^3
2.2046 lb 35.31 ft^3
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.0791564482240664 0.9999 0.0791482231633097 0.045747672988393
0.632978696694845 0.0001 6.57721304427652E-05 3.80162913959183E-05
1.0000 0.0792 0.0458
T= 320.13368218563
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
0.766684649895601 0.9999 0.766604984524452 766.604984524452
1.00712018016849 0.0001 0.00010464876655007 0.104648766550064
0.766709633291002 766.709633291002
k liq (W.m/K) Fraksi Mol k liq mix (W.m/K) k liq mix (btu/jam ft F)
0.62753103292025 1 0.62753103292025 0.362712937027904
T= 315.15
ρ mix (g/cm3) ρ mix (kg/m3)
ρ Fraksi
1.01177725125691 1 1.01177725125691 1011.77725125691
1 cP 1 mmHg
2.4191 lb/ft hr 0.0193 psi 1
2.7792 lbf/ft^2 144
1.0088302730234
0.0002020119131
1.0090
Cp mix (Btu/lb F)
0.6087709199865
0.0001031441126
0.6089
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
47.863419679485 0.7872443337914 0.9999 0.787162532085797 787.162532085797
0.0065338054584 1.0274529145287 0.0001 0.000106761518943755 0.106761518943755
47.869953484943 0.787269293604741 787.269293604741
2.1113847680567
Cp mix (Btu/lb F)
0.9934404275398
T= 298.15
ρ mix (lb/ft3) ρ standar mix (g/cm3) ρ standra mix (kg/m3)
ρ Fraksi
63.1708900629 1.0274529145287 1 1.02745291452869 1027.45291452869
psi
lbf/ft^2
ρ standar mix (lb/ft3)
49.1469418928447
0.0066657163597678
49.1536076092045
ρ standar mix (lb/ft3)
64.1496090447448
COOLER
Fungsi: Mendinginkan
Tipe: Dou
Gambar:
Karena A < 200 ft2, maka digunakan Double Pipe Heat Exchanger
Shell (annulus)
Nominal Pipe Size, IPS 8.0000 in
Schedule. No. 40.0000
OD 8.6250 in
ID 7.9810 in
a" (surface per pipe) outside 2.2580 ft2/ft
a" (surface per pipe) inside 2.0900 ft2/ft
Dimana,
D2 (ID annulus)= 7.9810 in
D1 (OD inner pipe)= 6.6250 in
Maka, aa= 0.1080 ft2
De = 0.2491 ft
D= 6.0650 in
ap= 0.2005 ft2
Shell (annulus)
jH= 50.0000
Tube (inner pipe)
jH= 1.5000
8. Menghitung Prandtl Number (Pr)
Shell (annulus) (Pra) Sumber : Process Heat Tran
Pr= 13.4185
Pr^(1/3) = 2.3763
Pr= 5.7829
Pr^(1/3) = 1.7949
9. Menghitung Nilai h
Shell (annulus) (ho) Sumber : Process Heat Tran
OD = 6.6250 in
ID = 6.0650 in
Hio = 1.7689 Btu/hr ft2 F
Pers. Umum
Asumsi:
Rda (process fluida annulus pipe)= 0.0040 (source: Table 12, Kern)
Rdi (Saturated Steam annulus)= 0.0000 (source: Table 12, Kern)
Total Rd= 0.0040
Maka,
Rd= 0.0040
1/Ud= 0.6151
Ud= 1.6257 Btu/hr ft2 F
A= 7,924.5341 ft2
D'e= D2-D1
D'e= 0.1130 ft
2) Reynold Number
Sumber : Process Heat Transfer by Kern Hal. 112
Rea= 2,834.2930
f= 0.0129
V= 0.1469 ft/s
6)
f= 0.1887
3) ΔPp
SUMMARY
IDENTIFIKASI
Nama Alat
Kode Alat
Jumlah
Operasi
Fungsi
DATA DESAIN
Tipe
Number of Hairpins
Bahan Konstruksi
Rd actual
Overall Clean Coefficient (Uc)
Overall Design Coefficient (Ud)
Annulus Heat Transfer Coefficient (ho)
Inner Pipe Heat Transfer Coefficient (hio)
ANNULUS SIDE
IPS 8.0000 in
SN 40.0000
OD 8.6250 in
ID 7.9810 in
a" 2.2580 ft2/ft
ΔPa 0.28169 psi
COOLER-04
Mendinginkan aliran 14 sebelum masuk ke MP-01
Double-Pipe Heat Exchanger
1.9487 lb/Jam
Return bend Gland
80.6000 F
134.6000 F
Return Head
F
F
0.505416666666667 ft
Sumber : Process Heat Transfer by Kern Hal. 112
0.6089 Btu/lb F
1.0090 lb/ft jam
0.0458 Btu/jam ft F
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
Asumsi (μ/μw)^0,14 = 1
(Karena viskositas fluida < 1 cP)
0.5521 ft
0.5054 ft
ft
20.0000
Sumber : Process Heat Transfer by
Kern Hal. 112
Accepted!
Cooler
C-04
1 buah
Kontinyu
Mendinginkan aliran 14 sebelum masuk ke MP-01
Gland
Gland
Tee
Kern Hal: 89
40 Tabel. 8
nsfer by Kern Tabel 11. Hal. 844