www.vishay.com
Vishay Semiconductors
Single Phase Bridge Rectifier, 25 A, 35 A
FEATURES
• Universal, 3 way terminals:
push-on, wrap around, or solder
• High thermal conductivity package, electrically
insulated case
• Center hole fixing
• Excellent power/volume ratio
• UL E300359 approved
• Nickel plated terminals solderable using lead (Pb)-free
solder; solder alloy Sn/Ag/Cu (SAC305); solder
temperature 260 °C to 275 °C
D-34
• Designed and qualified for industrial level
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
PRIMARY CHARACTERISTICS
IO 25 A, 35 A DESCRIPTION
VRRM 200 V to 1200 V A range of extremely compact, encapsulated single phase
Package D-34 bridge rectifiers offering efficient and reliable operation.
Circuit configuration Single phase bridge They are intended for use in general purpose and
instrumentation applications.
ELECTRICAL SPECIFICATIONS
VOLTAGE RATINGS
VRRM, MAXIMUM VRSM, MAXIMUM
IRRM MAXIMUM
VOLTAGE REPETITIVE PEAK NON-REPETITIVE PEAK
TYPE NUMBER AT TJ MAXIMUM
CODE REVERSE VOLTAGE REVERSE VOLTAGE
V V
05 50 75
06 60 100
10 100 150
20 200 275
26MB..A,
40 400 500 2
36MB..A
60 600 725
80 800 900
100 1000 1100
120 1200 1300
FORWARD CONDUCTION
VALUES VALUES
PARAMETER SYMBOL TEST CONDITIONS UNITS
26MB..A 36MB..A
Resistive or inductive load 25 35
Maximum DC output current A
IO Capacitive load 20 28
at case temperature
65 60 °C
t = 10 ms No voltage 400 475
Maximum peak, one-cycle t = 8.3 ms reapplied 420 500
IFSM A
non-repetitive forward current t = 10 ms 100 % VRRM 335 400
t = 8.3 ms reapplied Initial 350 420
t = 10 ms No voltage TJ = TJ maximum 790 1130
t = 8.3 ms reapplied 725 1030
Maximum I2t for fusing I2t A2s
t = 10 ms 100 % VRRM 560 800
t = 8.3 ms reapplied 512 730
Maximum I2t for fusing I2t I2t for time tx = I2xx0.1 tx 10 ms, VRRM = 0 V 5.6 11.3 kA2s
Low level value of threshold voltage VF(TO)1 (16.7 % x x IF(AV) < I < x IF(AV)), TJ maximum 0.76 0.79
V
High level value of threshold voltage VF(TO)2 (I > x IF(AV)), TJ maximum 0.92 0.96
Low level forward slope resistance rt1 (16.7 % x x IF(AV) < I < x IF(AV)), TJ maximum 6.8 5.8
m
High level forward slope resistance rt2 (I > x IF(AV)), TJ maximum 5.0 4.5
TJ = 25 °C, tp = 400 μs, IFM = 40 Apk (26MB),
Maximum forward voltage drop VFM 1.11 1.14 V
IFM = 55 Apk (36MB)
Maximum DC reverse current IRRM TJ = 25 °C, per diode at VRRM 10 μA
RMS isolation voltage base plate VINS f = 50 Hz, t = 1 s 2700 V
150 1000
Instantaneous Forward Current (A)
26MB..A Series
Tj = 25 °C
130 Tj = 150 °C
100
110
180°
(Rect)
90
10
180°
70 (Sine)
26MB..A Series
50 1
0 5 10 15 20 25 30 0.5 1 1.5 2 2.5 3 3.5
Average Forward Current (A) Instantaneous Forward Voltage (V)
Rt
hS
TJ = 150 °C
(Sine)
A
40
=
1
2
K/
K/
W
W
-Δ
3K
R
30 180° /W
(Rect) 4K
/W
5K
20 /W
7 K/W
10 10 K
/W
0
0 5 10 15 20 25
0 25 50 75 100 125 150
Average Forward Current (A) Maximum Allowable Ambient Temperature (°C)
400 150
At Any Rated Load Condition And With
Rated VRRM Applied Following Surge 36MB..A Series
350 Initial TJ = 150 °C
at 60 Hz 0.0083 s 130
at 50 Hz 0.0100 s
300
110
250 180°
(Rect)
90
200
180°
(Sine)
150 70
26MB..A Series
100 50
1 10 100 0 5 10 15 20 25 30 35 40
Number of Equal Amplitude Half Cycle Current Pulses (N) Average Forward Current (A)
450 1000
Maximum Non Repetitive Surge Current
Instantaneous Forward Current (A)
250
10
150
36MB..A Series
26MB..A Series
50 1
0.01 0.1 1 0.5 1 1.5 2 2.5 3 3.5
Pulse Train Duration (s) Instantaneous Forward Voltage (V)
Fig. 5 - Maximum Non-Repetitive Surge Current Fig. 7 - Forward Voltage Drop Characteristics
0
0 5 10 15 20 25 30 35 25 50 75 100 125 15
0
Average Forward Current (A) Maximum Allowable Ambient Temperature (°C)
100 100
1 10 100 0.01 0.1 1
Number of Equal Amplitude Half Cycle Current Pulses (N) Pulse Train Duration (s)
Fig. 9 - Maximum Non-Repetitive Surge Current Fig. 10 - Maximum Non-Repetitive Surge Current
1 2 3 4 5
AC
(+)
AC
(-)
D-34
10.5 ± 0.15
(0.41 ± 0.006)
20.3 ± 0.15
(0.80 ± 0.006)
~
-
+ 1.0
21.5
- 0.5 9.5 ± 0.5 28.5 ± 0.15
+ 0.039 (0.37 ± 0.020) (1.12 ± 0.006)
(0.85 )
- 0.020
12.7 ± 0.1
(0.5 ± 0.004)
~
5.25 ± 0.15
(0.21 ± 0.006)
12.7 ± 0.1
(0.5 ± 0.004)
28.5 ± 0.15
(1.12 ± 0.006)
Not to scale
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.