You are on page 1of 13

Solar Plant Proposal

10 KWp ON GRID

SUN INTERNATIONAL
(COMPLETE SOLAR ENERGY SOLUTION)
AUTHORISED EXIDE INTEGRATOR
REGD.OFFICE- 112/1,2nd floor,Oberoi Tower,Arya Nagar
KANPUR-208002
CORPORATE OFFICE- 28-H,LAJPAT NAGAR-4,NEW DELHI-110024
Mob: +91 9956101502, 9838702704
E Mail ID : marketing.sunintern@gmail.com, marketing@sungripsolar.com
Proposal For: - OFFER NO-SI/2022-2023/103
Mr.Vinay Seth DATED 05/05/2022
3A/86, Azad Nagar Kanpur-208002
KIND ATTN: Mr.Seth
Cell No: 9839035228
E MAIL ID : NA

Page 1
Sun International
112/1,2nd floor,Oberoi Tower,Arya Nagar, Kanpur 208002.
9956101502 , 9838702704
Email - marketing.sunintern@gmail.com,info.sunintern@gmail.com

Table of Contents

A. Project Proposal summary Page-3

B. Site Loactation and Other Data Page-4

C. Detailed Bill of Material & Installation Details Page-5

D. Scope of work & Price Schedule Page-6

E. Delivery, Validity & Warranty Clause Page-7

Page 2
Sun International
112/1,2nd floor,Oberoi Tower,Arya Nagar,Kanpur 208002.
9956101502 , 9838702704
Email - marketing.sunintern@gmail.com,info.sunintern@gmail.com

Subject: PROPOSAL FOR ON GRID 10 KWp SOLAR PLANT

Dear Sir
With reference to your query and our discussion we are pleased to submit herewith our comprehensive
proposal of the Technical & Commercial overview, for your kind perusal.

SYSTEM DISCRIPTION.
S. No. Decription Data
1 Proposed Location KANPUR
2 Co-Ordinates 26°44"N, 80°33" E
3 System Discription On Grid
4 Installation Type Roof Top Mounted
5 PV Array Capacity 10 KWp
6 Operation Mode On Grid
MAIN BILL OF MATERIALS.
S.No Item Description
1 Solar Panel EXIDE

2 Inverter GROWATT
3 Mounting Structure Panels shall be mounted on zinc plated frames GI/Aluminium
frames. The structure is designed in such a manner that it can
withstand storm & can be installed/replaced easily and in line
with site requirements. All fasteners, nut and bolts are made of
Stainless steel - SS 304 5.4.6 PCC
4 Electrical Accessories Cables will confirm to IS 694 and Interconnections, array to
junction boxes, junction boxes to PCU etc will be selected near to
PV Panel to keep voltage drop and losses to the minimum. The
bright annealed 99.97% pure copper conductors offer low
conductor resistance, Result in lower heating thereby increasing
cable life and efficiency. These wires are insulated with a special
grade PVC compound formulated and manufactured.
Temperature range: -15 deg C to +70 deg C
Sizes: Suitable Size
Color Codes: Red, Yellow, Black, Blue, Green

Page 3
SITE LOCATION.

KANPUR

Site Coordinates: NA

Average Radiation: 4.6 kWh/m2/d

No of Full Production day assumed in a year 310

Month Air-Temperature Daily Solar Radiation- Horizontal Wind speed

°C kWh/m2/d m/s

January 14.8 3.84 2.3


February 18.1 4.91 2.6
March 24 6.05 2.7
April 28.9 7.04 3
May 30.4 6.36 3.4
June 30.3 5.94 3.6
July 28.4 5.01 3
August 27.6 4.57 2.5
September 26.1 4.73 2.4
October 23.5 5.12 1.9
November 19.8 4.41 1.8
December 15.7 3.71 2.1

Page 4
Detailed Bill of Material.

S. No Components Description Qty Make


1 PV Modules 330 or 390 Wp APSR EXIDE
2 String Inverter 10 KWp,On Grid Inverter. 1 Nos GROWATT

3 Mounting Structure Custome made G.I. or Aluminium NA 60-80 micron GI Coated


4 Cables/ Electrial Accessories AC Cables (As per IS) APSR Finolex / Grandley/National Or
5 Cables/ Electrial DC Cables (As per IS) APSR Polycab/Trinity /Siechem
6 ACDB/DCDB AC/DC Combiner box APSR Any standard make
7 Earthing Chemical Earthing Compound with APSR JMV/ any standard make
Rod
8 Lighting Arrestor Lightning arrestor-Copper Cladded APSR JMV/ any standard make
Aluminium
9 Installation and Commissioning As per site requirment APSR As per IEC standard.
**APSR = As Per Site Requirement.
Installation Detail.

Structural Anchoring Details:

Panels shall be mounted on zinc plated frames inclined. The structure is designed in such a manner that module can be
replaced easily and in line with site requirements and it is easy to install and service in future.

Inverter Installation

Based on the initial site visit, the inverters could possibly be installed in shed. This space provides ample accessibility and good
air circulation. The inverter is available in IP32 housing and hence it needs to be kept in well ventilated shed having protection
from direct sun-light and rains. Actual installation location and methods will be determined during full design phase.

Electrical

A detailed electrical design with single-line diagram and specifications will be prepared during full design phase after receiving
the technically & commercially clear P.O. along with requisite advance.

Page 5
Scope of Work

1 To conduct a detailed site visit with specialists to take accurate measurements, photographs, and other site-
specific information for full design
2 Prepare full system design to include , structural, electrical and mechanical components, with construction
drawings and specifications.
3 Procure equipment and materials and deliver to site
4 Perform complete system installation
5 Test all electrical components in accordance with manufacturer instructions
6 Commission the system to full operability

Client Scope

Site-specific considerations will require assistance and cooperation from the client, as outlined below

1 Provide access to work site for delivery of equipment and materials prior to and during project implementation.
2 Provide a suitable and secure space for storage of equipment and materials
3 Facilitate access of work crew to the work site 7 days a week
4 Facilitate interfacing with the client’s resident engineering staff for consultation as needed
5 All the Statutory clearances, if any, required for the Project work and goods transfer to site.
6 Any type of Civil Work such as room construction,Fondation,fencing or water point arrangements.
7 fortnightly cleaning of solar module after completing installation & commissioning.
8 Water Point should be provided near to installation site.
Price Schedule 10 KWp
SOLAR PLANT
S. No. Product Description Amount (Rs.)
10 KW ONGRID SOLAR POWER PLANT
1 Monocrystalline Modules & Grid Tie Inverter
Installation along with GI/alluminium Sructure, 398,000.00
Lighting arrestor,DC & AC Cable ,Earthings.
Gst Extra @ 13.8% AT ACTUALS

2 Net Metering Expenses are excluded of above prices.

3 D.G.Synchronising panel cost has not been taken in above cost

Other Terms & Conditions:


1 40% of the amount payable as advance along with Formal PO for a specific Solar System size.
2 55% against PI before dispatch of material from respective manufacturer.
3 5 % Balance amount on successful commissioning of the project.

Page 6
Delivery
Dispatch will be effected in 1-2 weeks from the date of acceptance of your Purchase order. (P.O) and receipt of advance.
System installation will be completed in 1-3 weeks time from date of receipt of materials at site, provided site is ready for
installation

Validity
This offer is valid for 10 days from the date thereof.

Warranty
Manufacturing Warranty for the System: 1 Years After installation and commissioning against any manufacturing
defect. However, for the solar panels & Inverters, the performance warranty is as under

Solar Panel
Performance Warranty
A 90% efficiency upto 10 years
B 80% efficiency upto 25 years
INVERTER - 5 years on site warranty.

For SUN INTERNATIONAL

Devesh Pratap Singh


9956101502/9838702704

This confidential document is copy right and the property of SUN INTERNATIONAL.It must not be copied (in whole or part) or
to be used for manufacture or disclosed without prior consent of the company.

Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13

You might also like